VFD PID Control Parameter And Wiring|PID Parameter Configured For Variable frequency Drive In Hindi|

แชร์
ฝัง
  • เผยแพร่เมื่อ 3 ธ.ค. 2024

ความคิดเห็น • 44

  • @khalipili2200
    @khalipili2200 4 ปีที่แล้ว +2

    Sir aapki all video very helpful hai

    • @jollyscaria1922
      @jollyscaria1922 4 หลายเดือนก่อน

      Verible ffreekance divered .vfd coroler builder mangement systom conrorld motor any trebels any way sound and any trobles solsed temp ahu conrolstopex motor ahu bely moter may be bering any porobles solve building mangent officeway ver fast vfe seting conrold solve after aychecking reparying sny way

  • @ashishvitekar3474
    @ashishvitekar3474 4 ปีที่แล้ว +1

    Very good video's and very informative keep it up and make videos on setting parameter

  • @mrityunjaykumar5407
    @mrityunjaykumar5407 3 ปีที่แล้ว +1

    Mujhe ACS560 drive ko PID and manual both mode me chalana hai.Maine 'ABB Standard Macro ' select kiya hai.One selector sw for selection of EXT1/EXT2.In EXT1 drive start from start pushbutton and stop from stop pushbutton.Frequency ref is from Potentiometer.Now in EXT2 ,i am selecting PIDSET1 ,Parameter 40.can i use same pot for setpoint in EXT2.Pot is connected to AI1 for process feedback i am selecting AI2.Ek aur clear karna hai.hamara pressure transmitter range (0 to 10 bar hai at 4 to 20 ma ) to scaling vfd me kitna set karen.
    target pressure set point 2.5 bar .

  • @mohanbhai8160
    @mohanbhai8160 3 ปีที่แล้ว

    Bhai ak manual leke sare fanda ak mehi clar kardo jisse idia aa jave 1h 2h 3h jitnebhi time ka hoga vidio with out skipp karke pura dekhung and like bhi karunga👍

  • @lakhdeepsharma1985
    @lakhdeepsharma1985 4 ปีที่แล้ว +2

    sir please make a video to be use abb acs 550 drive by controlling PID mode .also set parameter in video plz.

    • @niceelectronics9505
      @niceelectronics9505  4 ปีที่แล้ว

      Sorry abhi mere pas abb ki acs550 vfd nahi he magar Jab mere pas koi abb ki acs550 vfd ayegi to me pid par video banaunga...

  • @enginnergadungan
    @enginnergadungan 3 ปีที่แล้ว +1

    Good

  • @deeppatel2756
    @deeppatel2756 4 ปีที่แล้ว +1

    Ty for your videos, bhai ek bat batao ki Boiler me FD fan and ID fan and Booster fan auto me chalta he. To boiler ka pura wiring kese hota he?
    Konsi vfd kahase reference leti he?

    • @niceelectronics9505
      @niceelectronics9505  4 ปีที่แล้ว

      Sorry muje boiler ka pura working malum nahi he..Isliye me apko nahi bata paunga...Magar me apko vfd ko programm karva sakta hu apke function ke hisab se..

    • @deeppatel2756
      @deeppatel2756 4 ปีที่แล้ว +1

      @@niceelectronics9505 booster fan chalu hota he uske bad id fan chalu hota he aur uske bad hi fr fan chalu hota he. But id fan and fd fan ka reference kaha se lete he?

    • @niceelectronics9505
      @niceelectronics9505  4 ปีที่แล้ว +1

      Kya a tino motor same speed pe gumti he..?

    • @deeppatel2756
      @deeppatel2756 4 ปีที่แล้ว

      @@niceelectronics9505 thanks for quick response. Id fan and fd fan pid controller pe chalta he. 4-20 mA pe. Yokogawa PID controller UT35A ka configuration pe video banao. Wo thoda difficult he.

  • @khalipili2200
    @khalipili2200 4 ปีที่แล้ว +1

    Sir vfd programming kr
    Ke batao jab he clearly Ho payega thanks pid video ke liye ek video aur banana pid pr please vfd ke satth

    • @niceelectronics9505
      @niceelectronics9505  4 ปีที่แล้ว +1

      Thanx For your comment I will make a Practical Video on PID Setting in upcoming days Thanx

  • @babu-di7oi
    @babu-di7oi 2 ปีที่แล้ว

    👍👍👌

  • @wajidyoutuber4555
    @wajidyoutuber4555 10 หลายเดือนก่อน

    Nice video

  • @imkallam
    @imkallam 4 ปีที่แล้ว +1

    Wow...

  • @Brijesh8080
    @Brijesh8080 2 ปีที่แล้ว

    Hi, I have a question that if error value is minus that of set value then vfd will run in reverse or Will not start. In my case vfd speed is increasing after start command and unbalancing the system.
    How to solve the issue in ALTIVER 320 drive?

  • @JitenderKumar-sp4mi
    @JitenderKumar-sp4mi 3 ปีที่แล้ว

    Delta vfd ke sath video banao

  • @elseif7620
    @elseif7620 3 ปีที่แล้ว +1

    Sir mere pa fuji ka 10hp ka vfd lga hai us pe 7.5hp ka motar run ho rha hai jo Pulveriser pe lga hai mai chahta hu Pulveriser ke hopper se utna he gehu( Wheat ) nikle jitna motar full current load hai

    • @niceelectronics9505
      @niceelectronics9505  3 ปีที่แล้ว +1

      Please add current monitor with relay operating meter like multispan cc12

  • @kps-kindergarden7535
    @kps-kindergarden7535 ปีที่แล้ว

    Parameters set for pid control of l&t nx2000+ vfd

  • @pravingupta9012
    @pravingupta9012 3 ปีที่แล้ว +1

    Sir, we are installing a new drive in PID control mode & analog input is coming from potentiometer 0-10 V dc. When potentiometer is moving then frequency increasing also but potentiometer release means not moving still VFD frequency increased at maximum frequency. Sir, what is the problem what should we do to resolve the problem.

    • @niceelectronics9505
      @niceelectronics9505  3 ปีที่แล้ว

      Try to reduce intergral term if you set in vfd.

    • @matlesterdivinagracia6528
      @matlesterdivinagracia6528 3 ปีที่แล้ว

      Sir where should I connect the pid sensor terminals? on digital input or analog input?
      hope you can help me.

  • @puneetkejriwal3381
    @puneetkejriwal3381 3 ปีที่แล้ว

    This is a general explanation of what PID control means and does. where is the explanation regarding setting PID in a VFD of any particular model and the wiring as the title suggests?

  • @sonaramdewasi156
    @sonaramdewasi156 4 ปีที่แล้ว +1

    Kya sir 3hp moter ko 2hp(3.2kva)vfd se cala sakte hai ,

    • @niceelectronics9505
      @niceelectronics9505  4 ปีที่แล้ว

      Ha Chala sakte ho magar apki motor par light load hona Chahiye...

  • @khalipili2200
    @khalipili2200 4 ปีที่แล้ว +1

    Sir vfd ko syns kaise karte hai ek drive ko
    AVI. Gnd ko dusre Drive ke AFM gnd mein dete hai enternal dono Drive syncs hoti hai programming kaise hogi bataye

    • @niceelectronics9505
      @niceelectronics9505  4 ปีที่แล้ว +1

      Apko jis drive mese AFM as Output terminal use karna he usme apko AFM Terminal ko Output frequency ke liye programm karna padega..
      Badme is drive mese AFM and GND ko another VFD ki AVI and Gnd Ke terminal me dena he usase apki dono VFD Synchronize ho jayegi.. Thanx

    • @khalipili2200
      @khalipili2200 4 ปีที่แล้ว +1

      @@niceelectronics9505 sir is pr koi video bana Dena please

  • @gyanendrasahoo4731
    @gyanendrasahoo4731 4 ปีที่แล้ว

    Dimensions Ka konsa konsa model pe pid ha

  • @vishals11
    @vishals11 3 ปีที่แล้ว

    when to use independent mode and when to use dependent mode

  • @VISHALKUMAR-jb1km
    @VISHALKUMAR-jb1km 2 ปีที่แล้ว

    plc program me pid kaise use karte hi

  • @UmeshSharma-lx8ei
    @UmeshSharma-lx8ei 2 ปีที่แล้ว

    Auto mode 4 20 m A vfd control motor sped btaye

  • @mansureee9449
    @mansureee9449 ปีที่แล้ว

    🎉🎉🎉

  • @ManojKumar-xm3oi
    @ManojKumar-xm3oi 4 ปีที่แล้ว +1

    Sir ji apka WhatsApp no mil sakta hai kaya