@@niceelectronics9505 how to connect vfd to other circuit.... Means how to control rpm, acc, dec, externally. Like arduino or any other microcontroller where we have PWM signal/Digital signal.(without potentiometer)
Ha transistor output ko bhi relay ki Tarah programming kar sakte he magar usme transistor ki voltage and current rating kam hoti he so transistor output se ap jyada amp and voltage Nahi le sakte..
er4 Option communications error Problem A communications error occurred between the option card and the inverter. Possible Causes What to Check and Suggested Measures (1) There was a problem with the connection between the option card and the inverter. Check whether the connector on the option card is properly engaged with that of the inverter. Reload the option card into the inverter. (2) Strong electrical noise. Check whether appropriate noise control measures have been implemented (e.g. correct grounding and routing of signal wires, communications cables, and main circuit wires). Implement noise control measures.
Thanx Sandeep Patel for your review about Video. I Speak Multispeed instead of multi frequency in this video it's my mistake. But Multispeed and Multi frequency ka meaning same hi hota he so don't make any confusion in mind. Any other queries please share I would try to solve it... Thanx again. Have a nice day.
Are Bhai Hame to FVR - Micro Ki multi speed or reverse forward setting Nahi ho pa rahi hai Please Yaar espe ek video Banaye eska model no - FVR3_7S1S -4 E Hai eski koi bhi video you tube par Nahi hai Please Yaar espe ek video Bana de eski book me bhi samjha dena Bhai kese Karni
(Enable circuit failure) (1) Poor connection of interface PCB Check that the interface printed circuit board (PCB) is firmly connected to the inverter unit. Restarting the inverter releases the alarm. (2) Enable circuit logic error Check that the logic states of the output of safety switches match with each other (EN1/EN2 = High/High or Low/Low). Restarting the inverter releases the alarm.
Thanx Manish Jha For Your Comment. Yes it is possible . But one Command need to give to vfd. Tell me which fuji model vfd you use ? Because for your application you need to run vfd in PLC Mode but in every vfd this parameter is not available. Thanx
Very nice video.
excellent and clear
Please make video on rpm meter connection & analog output parameter settings on fremic mini fuji drive
When we use x1 connections in E01 -1 which speed motor will take potential meter speed or multi step speed
Thank you the video, Sir can the similar setting be done on the danfoss vlt micro drive?
Do you have any video about using rotary encoder with vfd
Sorry Praveen Sharma there is no video about rotary encoder with vfd but I will try to make it's in few days.. Thanx For Your Comment..
@@niceelectronics9505 looking forward to it eagerly
Sir, ye settings push battan se cantrol kar sakte hai kya?
Matlab Please explain.
External PCB se kaise control kr sakte hai..... Digitally (pwm signal)
Please explain about your question in detail..
@@niceelectronics9505 how to connect vfd to other circuit....
Means how to control rpm, acc, dec, externally.
Like arduino or any other microcontroller where we have PWM signal/Digital signal.(without potentiometer)
you can do this with RS485 communication only...no other pcb require .
Sir, vfd me transistor output terminal ka kya use hai
Ha transistor output ko bhi relay ki Tarah programming kar sakte he magar usme transistor ki voltage and current rating kam hoti he so transistor output se ap jyada amp and voltage Nahi le sakte..
Sir ji.
Fusi frenic drive me Er 4 a raha he kya check kru.
er4 Option communications error Problem A communications error occurred between the option card and the inverter. Possible Causes What to Check and Suggested Measures (1) There was a problem with the connection between the option card and the inverter. Check whether the connector on the option card is properly engaged with that of the inverter. Reload the option card into the inverter. (2) Strong electrical noise. Check whether appropriate noise control measures have been implemented (e.g. correct grounding and routing of signal wires, communications cables, and main circuit wires). Implement noise control measures.
Sir make a vedio on fan speed controling
Without pressed Run key
Drive goes to run mode ?
Multi speed x1 x2 x3 x4 multi fqwency setting
Thanx Sandeep Patel for your review about Video. I Speak Multispeed instead of multi frequency in this video it's my mistake. But Multispeed and Multi frequency ka meaning same hi hota he so don't make any confusion in mind. Any other queries please share I would try to solve it...
Thanx again.
Have a nice day.
Are Bhai Hame to FVR - Micro Ki multi speed or reverse forward setting Nahi ho pa rahi hai Please Yaar espe ek video Banaye eska model no - FVR3_7S1S -4 E Hai eski koi bhi video you tube par Nahi hai Please Yaar espe ek video Bana de eski book me bhi samjha dena Bhai kese Karni
Drive k frequecy 120 say oper nahi jati ye q. F03, F04, F15, C06, in sab may 150 set ha.
Fuji frn75g11s invirter fault 2 how to reset
Keypad Panel communication error
Do you have English version?
Sorry no English version available..
Forward और reverse ऑफ होने के बाद भी हमें कुछ holding frequency चाहिए तो कहाँ पर क्या करें?
Push batton ki programing kaise kare
Sir you give me fuji drive parameters lt CT ,hoist drive
Sorry it require practical site view and connection to set parameter.
Thaks sir
Sir
Motar 7.5Hp
Nani chal raha hai
Raun command mang raha hai
Thanx Harishchandar Verma For your Comment. Drive ka model konsa he? Drive ka HP Bhi bata dena ? Thanx I am waiting For your Reply.
fuji inverter ecf Alam resat
(Enable circuit failure)
(1) Poor connection of interface PCB
Check that the interface printed circuit board (PCB) is firmly connected to
the inverter unit.
Restarting the inverter releases the alarm.
(2) Enable circuit logic error
Check that the logic states of the output of safety switches match with
each other (EN1/EN2 = High/High or Low/Low).
Restarting the inverter releases the alarm.
Sir video
Zoom kar ke
Thanx Harishchadar Verma For Your Review For Video. I will try to improve video quality in upcoming Video.
Thanx again.
Multi speed ki parameter setting kaise karte hai
No sir i want to diffrent speed more than 5 speed without any wire use for speed
Thanx Manish Jha For Your Comment.
Yes it is possible . But one Command need to give to vfd. Tell me which fuji model vfd you use ?
Because for your application you need to run vfd in PLC Mode but in every vfd this parameter is not available.
Thanx