XSY-AT1 VFD Variable Frequency Drive Remote Panel Programming

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ก.พ. 2023
  • I've made a panel so I can control my VFD remotely, simple set up for run/stop, forward/reverse and variable speed.
    I have used a couple of toggle switches and a 10kohm potentiometer.
    My VFD is manufactured by XinShuangYuan Co LTD in China.
  • ยานยนต์และพาหนะ

ความคิดเห็น • 13

  • @user-ef7gw5pg2l
    @user-ef7gw5pg2l 7 หลายเดือนก่อน

    Thank you for making the addition of controls to the VFD so easy to understand. I have looked at a number of videos and most talk about alot of BS and not the practical part of adding the VFD to an existing machine.

    • @bodganeering
      @bodganeering  7 หลายเดือนก่อน

      Glad it was helpful!

  • @lucapalermo29
    @lucapalermo29 ปีที่แล้ว

    Great 👍 please can you show ke how connect Star and stop in the panel ?🙏

  • @lucapalermo29
    @lucapalermo29 ปีที่แล้ว

    I bought an start & stop button all in one but before i connect potenciometer and reverse direction 3 button 1-0-2
    But if i want use specific button i must to connect a bridge from this one reverse control to start & stop to activate?

    • @bodganeering
      @bodganeering  ปีที่แล้ว +1

      The manufacturers instructions aren't very clear and show the wiring connections the wrong way round. You will need a wire from the COM to both switches, either from the VFD or bridged from the switches.
      Then run a separate wire from each switch, START/STOP to X4 and Forward/Reverse to X6.
      X4 will need to be programmed as I show at around 1:30.
      X6 is already programmed by the manufacturer so you shouldn't need to change anything on the VFD.
      If you look at the picture at 2:11 you can see the wires I have connected. RED/BROWN from COM to switches. WHITE for START/STOP and Green for FORWARD/REVERSE.
      BLACK, BLUE and YELLOW are for the potentiometer.
      Hope this helps.

  • @user-xx2wk6jp5d
    @user-xx2wk6jp5d 11 หลายเดือนก่อน

    Hi can you please help i have a cross cut saw and need to put in a two way switch so that i can have it running continuously or on the hand button stop&start also i need to put in an emergency stop

    • @bodganeering
      @bodganeering  11 หลายเดือนก่อน

      Sorry, but it wrong be wrong to give out 'how to' advice on wiring machines up especially safety circuits, I would recommend you consult a qualified electrician to assist you in this.
      As I state on my channel information and in my videos this is how I do things and professional advice should always be sought.

  • @sarkistatuljan2950
    @sarkistatuljan2950 5 หลายเดือนก่อน

    One question - can you program the XSY-AT1 VFD Variable Frequency Drive
    so that it runs at high speed for about 2-3 minutes at the beginning, but closer to fixed low speed?

    • @bodganeering
      @bodganeering  5 หลายเดือนก่อน

      I don’t think this unit has that flexibility as there’s no timer on the system.

  • @HVACOOL
    @HVACOOL ปีที่แล้ว

    What fault FC002?
    Please

    • @bodganeering
      @bodganeering  ปีที่แล้ว

      Looks like under voltage. Your supply voltage is too low.

    • @HVACOOL
      @HVACOOL ปีที่แล้ว

      @@bodganeering cant change display coz setting unfungction?

    • @bodganeering
      @bodganeering  ปีที่แล้ว

      I would suggest contacting the manufacturer.