How To Wire Viessmann 050-w Opentherm or 240v switching

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 ม.ค. 2025

ความคิดเห็น • 84

  • @AllenHart999
    @AllenHart999  3 ปีที่แล้ว +1

    Candlelighters children's Cancer Charity. www.justgiving.com/fundraising/cchleeds
    How to operate EPH control th-cam.com/video/hmAnfVEUE5s/w-d-xo.html
    How to wire opentherm th-cam.com/video/b3ulvuZVegk/w-d-xo.html
    How to wire EPH controls th-cam.com/video/peqIxSuD-Jo/w-d-xo.html

  • @GlenS123
    @GlenS123 3 ปีที่แล้ว +6

    Don't understand manufactuers today. You are a seasoned proffesional that was having a hard time following wiring directions. How are apprentices going to follow it? Great series so far.

    • @AllenHart999
      @AllenHart999  3 ปีที่แล้ว +1

      Viessmann boiler instructions are not the easiest to understand. Thanks.

  • @sudhiradhikari19
    @sudhiradhikari19 3 ปีที่แล้ว +1

    Thanks for the video Allen, now I will be watching your previous videos like you said because it still hasn't gone to my head, I think will understand after watching them few more times.

  • @waynenixon729
    @waynenixon729 3 ปีที่แล้ว +1

    Just been reading your story on the Yorkshire Post. Good luck with your goal of raising £1M for candlelighters. I'm sure you'll get lots of support from the people on this channel. Take Care.

    • @AllenHart999
      @AllenHart999  3 ปีที่แล้ว +1

      Might take me a long time but I will keep plodding away. Thanks.

  • @IanHasler-cq5mf
    @IanHasler-cq5mf ปีที่แล้ว +5

    For OpenTherm, check where the OT connections go to for X12 on the board (p26 of the Installation and service instructions) are connected on the 4-way terminal block. The Terminal block is not numbered in the instructions (unhelpful from Viessmann!) and the labeling on the black plastic should be ignored. Buzz them out with a multi-meter back to X12 on the board. I found the OT terminal on the block are 3 for OT- & 4 form OT+, unlike Alan's connection in the video which shows connections 1 & 2.
    Having changed to connections 3 & 4 .... the F95 error (no OpenTherm connection) has gone away!!!!! 👍👍
    Also remember to change the "Operating Mode" (C.7) to 14 - OpenTherm, via the Commissioning, (p32 of the Installation and service instructions). 👍👍

    • @AlanClark-qf3gr
      @AlanClark-qf3gr ปีที่แล้ว

      Same issue with my boiler, didn't work on OT terminals 1 and 2
      , works on 3 and 4

    • @kevinmcindoe8856
      @kevinmcindoe8856 8 หลายเดือนก่อน

      Absolutely correct with this board markings, the black plastic is marked up incorrectly and Veissmann know about it? I’ve just had this problem too but only just read the comments. Wired a Salus OT thermostat up to terminals 1 & 2 but also wired in the external temp sensor to terminals 3 & 4. Boiler wouldn’t work correctly when set to OpenTherm control on commissioning, showing a red triangle fault error 95, no connection to OpenTherm? Thought the thermostat was at fault, the service guy on help desk knew of this issue and said the chock block markings are upside down so swap them around. 1 & 2 for external thermostat and 3 & 4 for OpenTherm connections. All worked spot on after that! What about Quality Control or at least a memo with the boiler. 😮

    • @es3t
      @es3t 10 วันที่ผ่านมา

      Today I tried to install Netatmo Modular Thermostat with Relay that has OpenTherm. Also connected the same way like Allen did but got 95 error. So I study the documentation schema and saw that it might be upside down and O.T is on the right side as in the docs are on the left. So I switched that but still I have 95 code. :/ for God Sake I don't know what is wrong with that damn thing. Doesn't matter where I connect black or grey yes? Maybe I should flip those cables. I'm totally confused. But let me get this clear are we talking about the same Boiler? 050-W B0HA-25 ? I even checked all 6 variations , 1&2 at the beginning, 3&4, 2&4, 1&3, 1&4, 2&3. Nothing. I removed also the link on 96 port. I don't know maybe I should consider this to Viessmann and report that the motherboard opentherm is damaged ?

  • @BerkayÖzdemir-f4b
    @BerkayÖzdemir-f4b 2 หลายเดือนก่อน

    Simple and very useful-great video! Thank you, Allen.

  • @gavinderbyshire5535
    @gavinderbyshire5535 ปีที่แล้ว

    Great, first one installed today. Couldn’t even get the cover off..😂 it helped a lot as we used existing controls.

  • @normanboyes4983
    @normanboyes4983 3 ปีที่แล้ว +4

    Well explained Alan. I also thought that the casing seal looked to have been fitted rather ‘skew wif’ on a brand new boiler (top edge)

    • @AllenHart999
      @AllenHart999  3 ปีที่แล้ว +2

      Hi Norman. Well spotted, Yes it wasn’t on very well. Thanks.

    • @normanboyes4983
      @normanboyes4983 3 ปีที่แล้ว +1

      @@AllenHart999 Not bad for a non plumber or a gas safe bod eh? Just a time served Marine Engineer.😉

    • @AllenHart999
      @AllenHart999  3 ปีที่แล้ว +1

      @@normanboyes4983 You clearly have an idea of what to look out for. Thanks.

    • @SalimKhan-gk1fh
      @SalimKhan-gk1fh 3 ปีที่แล้ว

      @@AllenHart999 I think you should ring viessmann and get a new seal kit sent down to you

  • @vulcancontinental
    @vulcancontinental 3 ปีที่แล้ว +1

    Good video. You can do multiple zones with EPH controls over OpenTherm, DHW too. Be interested to see the BeSMART connected to see what info the Viessmann can provide. The OpenTherm connections look like an afterthought stuck onto the back of the controls tray and the wiring and controls box a bit fiddly.

  • @giuseppepelella2650
    @giuseppepelella2650 10 หลายเดือนก่อน +1

    Dear Allen, How do you connect the Viessman Vitodens 100W 32 Kw to the Honeywell Evohome wifi thermostat?

  • @paulg2726
    @paulg2726 3 ปีที่แล้ว +1

    Great video Allen , please keep them coming 👍🏾👍🏾

  • @chengambj
    @chengambj 3 ปีที่แล้ว +3

    You didn't mention how to wire outdoor weather compensate into the boiler connection block. Or is outdoor weather compensate control dead in the water nowadays?

    • @AllenHart999
      @AllenHart999  3 ปีที่แล้ว +2

      Weather comp is wired in 3 and 4, I will do an updated video at some point Thanks.

  • @christophechris2165
    @christophechris2165 8 หลายเดือนก่อน

    Please add a video of the 100-w system boiler s plan plus wiring 😊

  • @mattkaramccarthy677
    @mattkaramccarthy677 3 ปีที่แล้ว +1

    This boiler also works with the ViCare wireless thermostat and the ViCare app. No wiring needed.

    • @DannyDL1ght
      @DannyDL1ght 3 ปีที่แล้ว +3

      It’s true but the vicare thermostat does not have a display, you are forced to use your phone. What happens if you break your phone diplay or lose internet connection ?how will you control that thermostat 😅

  • @coltmanneil
    @coltmanneil ปีที่แล้ว

    Would love to know hot wire the 050 to a standard hive receiver 😢

  • @mirceanichitov3615
    @mirceanichitov3615 3 หลายเดือนก่อน

    So I don't have to remove the 96 connector, or at least remove the loop when connecting the thermostat?

  • @christopherclifford6402
    @christopherclifford6402 2 ปีที่แล้ว

    Hi Allen are you able to do a video on the previous Viessman 050 connecting to Google Nest and Opentherm?

  • @paulycc5449
    @paulycc5449 2 ปีที่แล้ว

    Hi Allen
    Can you remove the fly lead altogether if your wiring a hive in to work as on/off??

  • @retrocarclub
    @retrocarclub 2 ปีที่แล้ว

    I've just checked the wiring diagram on my brand new 100-w heat only and it doesn't look like it has the wires (only 3&4 for the outside sensor). Have Viessmann discontinued it or something?

  • @dimik96
    @dimik96 7 หลายเดือนก่อน

    Hallo, wie aktiviert man Warmwasser beim Wok-Typ Vitodens 050-w?

  • @EugenioAlbarracin
    @EugenioAlbarracin ปีที่แล้ว +1

    I bought a smart thermostat and only the two red and white cables come, the common blue cable is not connected to the boiler, so the smart thermostat does not work, what can I do, where do I install the blue cable in the boiler?

    • @AllenHart999
      @AllenHart999  ปีที่แล้ว +1

      Not really sure what you are asking?

  • @coltmanneil
    @coltmanneil ปีที่แล้ว

    We tried to connect the vitodens 050 to hive and we had to use terminals x12 terminals 3/4 on drawing boiler OTS , on hive receiver 1/3 , setting on boiler c7 13 in menu all good .

    • @coltmanneil
      @coltmanneil ปีที่แล้ว

      Oh and we had to remove link x96

  • @vladimirstafasani4630
    @vladimirstafasani4630 3 ปีที่แล้ว

    As always great video Allen👍
    I found challenging as well taking the casing off. Didn’t help that Viessmann sent the wrong instructions with the boiler( older viessmann). I’m still not sure how to take the casing off. On Saturday I’m going to commission the boiler so hopefully I can take the casing off.
    Do you just push both the two catches up to remove the casing?
    Thank you

  • @danemilic3966
    @danemilic3966 3 ปีที่แล้ว

    Hello Alan, is it possible to adjust the temperature of the boiler with the mobile phone.

  • @adlangoubid8198
    @adlangoubid8198 2 ปีที่แล้ว

    When connecting the nest system to open therm do you remove that 230 link that your normally remove for standard stat wiring or do i leave it in

    • @sinner_8779
      @sinner_8779 2 ปีที่แล้ว

      I removed the link on mine, but i have anoder problem, the pump its working non stop. The burner stops but the pump no .

  • @daron8982
    @daron8982 2 ปีที่แล้ว

    where in the boiler do you connect the wires

  • @darnamous-plomberieetchauf1209
    @darnamous-plomberieetchauf1209 7 หลายเดือนก่อน

    Hello sir I have a some boiler in Algeria and I have three errors 18 , 95, 49 and CL
    and the sensor of exhaust is not installed .
    How to start this boiler please help me 😊

  • @harryblack6002
    @harryblack6002 3 ปีที่แล้ว +1

    Another great video Allen. As always 💪🏼
    But that case seal looked pretty loose when you took it off, this is a brand new boiler ? Don’t know if it’s the angle of the camera mate. Just at the top of it

    • @AllenHart999
      @AllenHart999  3 ปีที่แล้ว

      The case seal definitely needs attention. Thanks.

  • @ThePommiecouple
    @ThePommiecouple 2 ปีที่แล้ว

    As long as you have changed the settings to opentherm C7 :14 on commission app

  • @Droneguy-be1fy
    @Droneguy-be1fy 2 ปีที่แล้ว

    Thanks for the video. I have this boiler. It won’t let me adjust the DHW or the Heating loop temperature directly on the boiler, I press the up and down arrows but nothing happens. I wired it up for opentherm on my nest gen 3 is this why? Does it do automatically with opentherm instead and blocks out the manual adjustment? Thanks in advance

    • @kevinmcindoe8856
      @kevinmcindoe8856 8 หลายเดือนก่อน

      OpenTherm will override the boiler front key settings, so do it on stat controller

  • @es3t
    @es3t 10 วันที่ผ่านมา

    Hi Allen, I have netamto relay opentherm but after doing exactly how you did and connecting this relay my Boiler shows issue. After checking the error code it shows 95 which is lack of opentherm communication. I can't understand what's the problem.

    • @WillTunna
      @WillTunna 4 วันที่ผ่านมา

      Pretty sure you need to go into commission mode on the boiler and change it to Opentherm mode instead of the normal switch on/off mode. It’s in the manual

    • @es3t
      @es3t 4 วันที่ผ่านมา

      @@WillTunnabut did you read my comment ? It says I did what Allen did, which is connecting to opentherm and of course I changed c7 to 14 and that’s why I can see error related with it which is 95

  • @vinp2007
    @vinp2007 3 ปีที่แล้ว +1

    Hi do you have any idea why the 200-W does not support opentherm. Or does it?

    • @AllenHart999
      @AllenHart999  3 ปีที่แล้ว +1

      you can definitely use opentherm on the 200. Thanks.

    • @vinp2007
      @vinp2007 3 ปีที่แล้ว

      @@AllenHart999 I am guessing this is not native opentherm as there are people who are saying it does not support opentherm, i am looking through various articles and blogs and there is just not much pointing to say it does, so is it through the KM BUS or something else? There are people saying that it invalidates the warranty. I am trying to find a system boiler that supports opentherm natively or if through another controller then that's fine providing it works well, but want to make sure i don't invalidate the warranty, this is for an extension i will be doing this year, so basically will be stripping the old one out and put a new one with ufh and radiators and try and get the best setup for condensing. Appreciate your input.

  • @petersteele46
    @petersteele46 2 ปีที่แล้ว

    Hi can I use a Google Nest on a Viessmann Vitodens 050w 30kw Combi Boiler?
    Like your vids nice and clear and easy to understand even to me

  • @madonion48
    @madonion48 3 ปีที่แล้ว

    Why there's a loop on the on/off thermostat connection ? I now have an on/off thermostat linked there and I want to wire an opentherm one. I have to make the loop too ?

    • @turnah
      @turnah 2 ปีที่แล้ว

      did you work this out? I'm wanting to do the same myself

    • @madonion48
      @madonion48 2 ปีที่แล้ว

      @@turnah i didn’t use the loop, I removed it.

    • @alexsindrilaru6901
      @alexsindrilaru6901 2 ปีที่แล้ว

      @@madonion48 is the boiler functioning normal on open therm without the loop? I have the same situation now and I'm still not sure if the loop is really necessary or not. Thanks

    • @madonion48
      @madonion48 2 ปีที่แล้ว

      @@alexsindrilaru6901 yes, it works very well without the loop.

  • @alexj5760
    @alexj5760 3 ปีที่แล้ว

    Great video 👍🏻👍🏻👍🏻

  • @SheikhtarigjameelSheikh
    @SheikhtarigjameelSheikh 3 ปีที่แล้ว +1

    Very nice۔
    Thanks and regards۔

  • @sinner_8779
    @sinner_8779 2 ปีที่แล้ว

    Conected to opentherm but now the pump its working non stop. Any ideea why? Please help!

    • @puddle_puddle
      @puddle_puddle ปีที่แล้ว

      Did you ever solve this? (Hope so, it's been a year).

  • @MrKlawUK
    @MrKlawUK 2 ปีที่แล้ว

    Hi - just had a 050-w installed with a nest 3rd gen. Neat complaining it can’t detect opentherm and the boiler complaining about F95. Any thoughts? The boiler is just doing it’s own thing right now so I’m having to manually set flow temp

    • @AllenHart999
      @AllenHart999  2 ปีที่แล้ว +1

      You need the installer back. It may need setting up correctly

    • @sinner_8779
      @sinner_8779 2 ปีที่แล้ว +1

      C7:14 on settings

    • @MrKlawUK
      @MrKlawUK 2 ปีที่แล้ว

      @@sinner_8779 yep it’s on. boiler looks to be firing in continuous mode

    • @MrKlawUK
      @MrKlawUK 2 ปีที่แล้ว

      @@AllenHart999 he wasn’t too sure either. Wiring looked good to OT1/2, set with C7-14, nest set to opentherm but reported issue not detecting opentherm. Will need to wait until tomorrow

    • @AurelMariusSandu
      @AurelMariusSandu ปีที่แล้ว

      Hi, did you solved it? I have same problem. OT on 1 and 2, removed jumper, set C7-14. F95 error appears.

  • @vipergas5542
    @vipergas5542 3 ปีที่แล้ว +1

    👍👍👍👍👍

  • @peadarohora2866
    @peadarohora2866 2 ปีที่แล้ว

    Thanks Alan excellent video

  • @keithbrueton
    @keithbrueton 3 ปีที่แล้ว +1

    That earth was hard to see

  • @2stepzahead
    @2stepzahead ปีที่แล้ว

    I came here on how to open it. Bloody difficult

  • @rosstaylor4924
    @rosstaylor4924 3 ปีที่แล้ว

    Thanks 🙏 for the video 👍

  • @kevincranfield5235
    @kevincranfield5235 3 ปีที่แล้ว +1

    Vogue is better. 😂

    • @AllenHart999
      @AllenHart999  3 ปีที่แล้ว

      I am still going to try and bring the vogue back to life. Thanks.