How to charge mini split yourself, DIY 410a refrigerant, save money!

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ส.ค. 2019
  • New 470a refrigerant that replaces 410a refrigerant, with Do-It-Yourself kit included..... ebay.us/tVSqEv
    Thermometer I use at the very end...... amzn.to/2Kv7mca
    New 470a refrigerant that replaces 410a refrigerant, with Do-It-Yourself kit included..... ebay.us/tVSqEv
    1 ton, cool only with Wifi & Alexa..... amzn.to/3zlsaxz
    3/4 ton heat pump............... amzn.to/2Js0uLQ
    3/4 ton heat pump w/16 ft kit..... amzn.to/43Mdgwo
    1 TON, 17 seer....... amzn.to/2JrDGvE
    Senville 3/4 ton... amzn.to/2UiJhc5
    The affordable HVAC gauges..... amzn.to/31nTA1Y
    Senville Mini Split 3/4 ton... amzn.to/2UiJhc5
    Adapter for mini split (5/16 to 1/4)... amzn.to/2Ys9qLN
    2 stage vacuum pump..... amzn.to/2JWdeM4
    Mini split Air cond, 110v under $400….. ebay.us/jyUE9P
    Mini split Heat pump, 110v under 385.... ebay.us/ez2AWh
    Pad for outdoor... amzn.to/2EMd9Iy
    Refrigerant line protector kit... amzn.to/2Um1DZI
    Power cord.............. amzn.to/2XrPgQI
    Discount one year of Amazon Prime... amzn.to/2qz0RPa
    Kit to add outside plug..... amzn.to/2Y73aVE
    Nylog blue sealer on flare ends.... amzn.to/33iYLkS
    Or, use this gasket kit for flare connection... amzn.to/36LzxPa
    Alternate tankless water heater models CHEAP!... ebay.us/B1ssST
    Remember....... the proper way to charge a variable speed mini split is to completely evacuate the system, then weigh in the proper amount of refrigerant.
    2 stage vacuum pump..... amzn.to/2JWdeM4
    scale to weigh refrigerant.... amzn.to/3YOGKIS
    REMEMBER TO PURGE THE LINES! I started to film right after purging the lines, but just reminding you to get the air out of the lines! Purging........ On the yellow hose, 1-connect to tank, and gauges. Slowly open the valve on the REFRIGERANT tank as to slowly release some refrigerant 2-On the gauges, slowly unscrew yellow hose at manifold until you hear air out, should just take a second. Quickly tighten. On the blue (suction) hose, 1-Fully tighten hose on the HVAC unit, and on the gauges. 2-Slowly loosen connection on manifold, the remnants of air in the line will bleed out at the connection to the gauges, (you will hear the sound of air coming out) at the manifold connection, and you can quickly tighten immediately after. It is a split second thing! For best results, use a scale and weigh the refrigerant! That means that if it is not working properly the refrigerant must be removed and weighed, then recharged to the amount listed on the out door units tag. If you have low refrigerant, YOU HAVE A LEAK!
    How I get work and contractor leads…. bit.ly/2Vmps4a
    Program to edit your TH-cam videos….
    bit.ly/2ZtdTuJ
    How I make my TH-cam thumbnails… bit.ly/2BC12M6
    Best, dirt cheap cell plan..…. bit.ly/2LnPzqB
    Discounted cellular phones..... amzn.to/2ytIhsj
    100% straight forward FREE website builder… bit.ly/2Ypp7zZ
    25% OFF new Vanity Phone numbers when you select 2…… bit.ly/2X7bUhl
    Best foam mattress money can buy… bit.ly/2UZEpIK
    Most affordable internet VPN protection… bit.ly/2TPRhkF
    (use promo code HALFOFF4LIFE and get 50% off for life!)
    Dirt cheap eyewear... bit.ly/2TSp1hm
    AND bit.ly/2GrAGAQ
    Dirt cheap electronics… bit.ly/2N7uYVb
    AND bit.ly/2N7ZEp9
    Cellular related…
    Military drop tested cases… bit.ly/2V2XaLJ
    Cheap wireless chargers… bit.ly/2DFYL2Q
    Cases that charge phones… bit.ly/2Ne4gKJ
    Clearance phone cases… bit.ly/2BzXgTO
    Ghostek cases… bit.ly/2GwqE1p
    Save On printer ink.... • Save Money on Ink cart...
    Best in-ear sound… bit.ly/2SI1ZgC
    SUBSCRIBE to our channel… / savegreenhere
    Follow on Twitter… / savegreenhere1
    How to charge mini split yourself, get 410a refrigerant, save money!
    When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network. This video and description contains Amazon affiliate links, which means that if you click on one of the product links, as an Amazon Associate, I’ll receive a small commission. This helps support the channel and allows us to continue to make videos like this. Thank you for the support!

ความคิดเห็น • 656

  • @LongTrout
    @LongTrout 2 ปีที่แล้ว +1

    Save money... love this video.... best thing to ever happen for many split companies and HV AC contractors. Keep up the good work.

  • @barryl8491
    @barryl8491 ปีที่แล้ว +3

    What a simple, straight forward video. Spent 30 min searching around and countless videos to just confuse me untill i came upon this one. Thx!

  • @carpetgeniepsl
    @carpetgeniepsl 2 ปีที่แล้ว +1

    Thankyou. After looking at many videos, your was the best for my family. Saved 300

  • @Henryse
    @Henryse ปีที่แล้ว +1

    Sweet! our system is revived, because of your video. Thank you!

  • @DEtchells
    @DEtchells 3 ปีที่แล้ว +76

    IMPORTANT NOTE: You need to purge a little refrigerant through the hose connected to the refrigerant tank *before* connecting to your gauges. You do *not* want to get any air into the system! If you don’t purge the hose, you’ll inject all the air in it into the system.

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว +9

      Yes Dave, that is mentioned on the video description, but thanks for the reminder for everyone.

    • @williamwintemberg
      @williamwintemberg 27 วันที่ผ่านมา

      True

  • @prenticelennon3087
    @prenticelennon3087 2 ปีที่แล้ว +1

    Thank you Thank You THANK YOU!!! We are having heat wave in LA and my house was so hot and now it's cooling down!! My dogs thank you too!

  • @SaveGreenHere
    @SaveGreenHere  4 ปีที่แล้ว +2

    MAKE SURE YOU WEAR GLOVES....amzn.to/3fxiF1u AND SAFETY GLASSES..... amzn.to/3fuqFjv Remember to purge the yellow line, BEFORE you open the blue valve. So after attaching refrigerant jug, open the valve on the jug. Then press the schrader valve ( the pin that shows on th center of the manifold) with a small screwdriver for a split second, and allow just enough refrigerant out till you hear a split second pssst! We did this just before we started the filming, but did not catch in on the video.

  • @djchiesa3567
    @djchiesa3567 2 ปีที่แล้ว +1

    I am grateful for these videos. I'm a widow in N.Ca. and the contractors are constantly trying to gouge me. For a single ductless minisplit (21-24seer 18-21 btu) unit I've been quoted 6000-10,000. Costco has a mrcool 21seer/18but for $1,500 now I need to get a friend to help me install. I already had the electrician (his bid for a lot of work was 3.8K where most bids are at 7-10K for electrical work) install the 240/40amp circuit & outlet.

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว +1

      Even electrical seems high.

  • @SaveGreenHere
    @SaveGreenHere  ปีที่แล้ว

    New 470a refrigerant that replaces 410a refrigerant, with Do-It-Yourself kit included..... ebay.us/tVSqEv

    • @rigneynathan
      @rigneynathan ปีที่แล้ว

      Can you combine the two? Mines leaked out a bit. Need to add more but they don't even sell 410a anymore.
      Also you have an AUX like me. Mine stopped heating/cooling after a few months. I can't really tell why it's not keep refrigerated as there's not many indicators on the lines.

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว

      Yes you can combine.

  • @eddiename8727
    @eddiename8727 2 ปีที่แล้ว

    This video is very helpful, thank you for taking the time to help people like me.

  • @themongooser7199
    @themongooser7199 4 ปีที่แล้ว +8

    Thank you for the video. My 410a was delivered today and I just got done recharging my 24k BTU Mr Cool. PSI was at 75 and wouldn’t get my garage below 80. It was basically blowing warm air. Turned the AC to 73 and went outside to recharge it. Took about 5 min, As soon as I walked into the garage I could feel the cold air again.. Since I installed the split system myself I had all the tools already. $75 for a bottle of 410a is way better than $500 for a service tech to do it.

    • @SaveGreenHere
      @SaveGreenHere  4 ปีที่แล้ว +3

      AWESOME! Glad you got it, and glad you are cooling now!

    • @doddgarger6806
      @doddgarger6806 4 ปีที่แล้ว +4

      Fix the leak!

  • @Freedom_Aint_Comfort
    @Freedom_Aint_Comfort ปีที่แล้ว +6

    Thank you so much for your video I tried it on my Senville two air handler mini split. Aura model 18000btu. It worked like a charm but only after the third try. I must stress to everyone please bleed the lines. Make sure the air conditioner is running when you’re hitting this psi Mark. Again bleed the lines, bleed the lines on the gauges. If you ever have trouble DM me. I can explain to you in detail what I did. I don’t make TH-cam videos much at all. My leaks were s result of loose connections. All my refrigerant leaked out so I charged it from empty. Lord bless.

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว +1

      Great share, yes, very important, it was done prior, but also ensure you fix the loose connections BEFORE adding!

    • @dannyluong9246
      @dannyluong9246 ปีที่แล้ว

      Please show me how to charge it from empty (for multi-zone). Thank you

    • @patrickpham1704
      @patrickpham1704 ปีที่แล้ว

      Paper wadder: Please show me how to bleed the line. Thank you

  • @PhiNguyen-pc9qg
    @PhiNguyen-pc9qg 3 หลายเดือนก่อน

    Thanks for the video. Do you know if the procedure differs when you have more than one zone?

  • @donatasnuobara8107
    @donatasnuobara8107 2 ปีที่แล้ว

    Can agree with many, that video is really great! Would you be so kind and comment how you add refrigerant to air to water heat pump? Unit on and on heating ? What psi I should look for to check if it has the right amount of refrigerant? It's R410a. THANK YOU!

  • @stevecha3612
    @stevecha3612 2 ปีที่แล้ว +3

    Any recommendations if the unit has 5 line sets (5 units inside the building that are controlled by the one outdoor unit). Would you have all the indoor units running and is there a specific port to use for filling since there are 5 line sets?

  • @owenz3831
    @owenz3831 3 ปีที่แล้ว +2

    Thanks for the tutorial! The AC guy told me that the freon is 1-2 lbs lower than normal two weeks ago. I followed your instruction and made sure all the hoses were securely connected. However, the gauge shows a low side pressure of 0 (the AC is running fine). But it stayed at 210 psi when I release the refrigerant into the unit (is it the tank's pressure?) Do I need to open the service value to get the pressure readings?

  • @SaveGreenHere
    @SaveGreenHere  3 ปีที่แล้ว +2

    Remember, the unit needs to be running in cooling mode! Link to refrigerant, in case you missed it! ebay.us/YKjza2

  • @lardo5150
    @lardo5150 2 ปีที่แล้ว

    YES THank you! Getting ready to do this. Did you do anything with the valves? Did you turn them off or you just hook it up and ahve it running to add the juice? Talking about the valves you turn to release the refrigerant into the system.

  • @infonator1
    @infonator1 2 ปีที่แล้ว +1

    Hello, Can you hook up directly the yellow line on to the 410a refigerant tank or do you need the on /off valve adapter? Thanks.

  • @sierrasurvivor1798
    @sierrasurvivor1798 ปีที่แล้ว +3

    One other question. When beginning to add the refrigerant, should both high and low pressure valves on the outside unit of the minisplit be wide open?

  • @jimc8665
    @jimc8665 3 ปีที่แล้ว

    Great videos, thank you. Question: I have fujitsu flex dual zone with an AOU18RLXFZH outdoor unit, are the ideal low side pressures the same 117-120 with both evaporators running indoors? Just had a big snow storm up here in CT so it will be a while before I can run it in AC, but the system has had that water running sound along with gassing sounds after cycling off. Fwiw, its been doing that since I sucked it down, released the precharge and started using it last summer. No leaks according to nitrogen test or electronic leak detector since then.

  • @Captfuntastic
    @Captfuntastic 4 ปีที่แล้ว +2

    Thank you for posting this. I have 2 mini splits that need recharge every 2 years that costs me close to $500 each time I call a service tech. I got everything for less than $200 and should last me 10 years

    • @SaveGreenHere
      @SaveGreenHere  4 ปีที่แล้ว +2

      Glad to help. However, you may have a really small, slow leak if you need recharge every two years, and should try to find out where the source is. It may be at the ends. Try this, it works extremely well, and use it when you have to add refrigerant again, and you may never have to add refrigerant, as it's a closed loop system.... amzn.to/3edDJsX

    • @Captfuntastic
      @Captfuntastic 4 ปีที่แล้ว

      SaveGreenHere techs have checked everything and even new line sets and pressure test. They told me (2 different companies) that the flare fittings are what leaks and are a poor design. I loved these ductless units in the beginning but I would never do this again and cannot recommend them anymore.

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว +1

      @@Captfuntastic You need to use this. Otherwise, you are asking for it...... amzn.to/33zQLz6

    • @Captfuntastic
      @Captfuntastic 3 ปีที่แล้ว

      SaveGreenHere tried that already

    • @cengeb
      @cengeb 3 ปีที่แล้ว

      @@Captfuntastic Flares made right don't leak, mini splits are great, a good flare tool matters too

  • @upbeatgroove
    @upbeatgroove 2 ปีที่แล้ว

    Great video and thanks for the help.
    When adding refrigerant from a 410a
    tank do you keep the two valves open that you open with Allan wrench when releasing the precharged refrigerant from the outside unit upon installation or do you close them.
    Thanks again.

  • @ethanpn2003
    @ethanpn2003 8 วันที่ผ่านมา

    Thank you. Does it do the same to multi zones ?

  • @AlphaEntInc
    @AlphaEntInc ปีที่แล้ว

    Thank you for the refrigerant link. I will have all the supplies I need to get this done. QUESTION:
    When beginning to add the refrigerant, should both high and low pressure valves on the outside unit of the mini split be wide open? What about when doing a back pressure test with Nitrogen. Are they open or closed? I don't want to mess up the compressor or anything by accidentally shooting nitrogen in there if its not supposed to be. Thank you for all your help.
    Watched the ads for your channels ad revenue. Will be watching more of your mini split electrical wiring videos tomorrow.

    • @bkhoavo
      @bkhoavo 10 หลายเดือนก่อน

      You're not ready for this bro.

  • @jamesjuhcomery9291
    @jamesjuhcomery9291 4 ปีที่แล้ว +3

    How to bleed the refrigerant line before you add it back to the condenser?

  • @winefarmer1
    @winefarmer1 2 ปีที่แล้ว

    Is the procedure the same for a multi-head system?

  • @Commsprepper
    @Commsprepper 3 ปีที่แล้ว +2

    You have an awesome channel.

  • @diysolaradventures7894
    @diysolaradventures7894 ปีที่แล้ว +1

    What if you think your mini split is empty of freon and your compressor is barely running at all do I perform a pressure test and do I need to pull a vaccum before I add fresh refrigerant
    12,000 btu Senville low presser no refrigerant

  • @marcoendara719
    @marcoendara719 ปีที่แล้ว

    I connected the hoses to charge my Mitsubishi mini split and it looks like it has 150 psi. Does this mean it is overcharged and I need to remove some of the 410a to get to the 120 psi?
    The unit is running in cooling mode and the temp outside is 75 and 90% humidity.
    What is the best way to get it to the sweet spot 117-120 psi?
    Thanks

  • @richardday2893
    @richardday2893 3 ปีที่แล้ว +2

    Hi buddy
    What's the sweet spot for R32 please?

  • @WorkingTimbersCo
    @WorkingTimbersCo 3 ปีที่แล้ว

    When disconnecting the blue line will I lose refrigerant?

  • @stacktier8257
    @stacktier8257 3 ปีที่แล้ว +2

    Brilliant, thank you.

  • @rj2764
    @rj2764 ปีที่แล้ว +1

    It is 6 degrees outside and I put my pump in cooling mode but the outdoor unit will not come on because it is too cold any suggestions?

  • @garylespron7-WS
    @garylespron7-WS ปีที่แล้ว +1

    Nice! 👌Thanks for sharing ✌😎

  • @alvaroalcantartejeda2836
    @alvaroalcantartejeda2836 ปีที่แล้ว

    How to test mini split went it doesn't even turn on , how many psi when ist of should be reading.

  • @elkhunter307
    @elkhunter307 ปีที่แล้ว

    Is this static or dynamic, static pressure should be 120? Dynamic meaning the system is operating.

  • @davidbyer4558
    @davidbyer4558 4 ปีที่แล้ว

    Please bare with me as Im not a HVAC tech. Here goes. I just purchased a LG 22000 btu 1 zone mini split system. The unit comes pre-charged for a 25 foot line set, but I need a 35 foot line set to reach my living room,so I purchased one.. I believe after watching your 2 videos I would do this.....1) Install the system with the 35 foot line set. 2) Vacuum out the line set down to -30psi , wait a while and check for pressure leaks. If there are no leaks, my next step 3) would be to release the R410A which came pre-charged in the unit into the system. 4) Then I would check the pressure in the line set with the vacuum gauge to see what the psi is and then add as much R410A..... which I would have to purchase separately, to get it to between 117psi and 120psi.. Im pretty sure there is no need to purge the system. Does this procedure sound correct....thanks PS the manual says to add 0.38 oz/ft. So that should be about 3.80 lbs.

    • @SaveGreenHere
      @SaveGreenHere  4 ปีที่แล้ว

      Yes, sounds like you should be fine. It will be very critical, to use the sealer, amzn.to/367xEf2 to ensure no leaks at the connections. Hope you have your refrigerant already. Ebay seems to still have it, but there's an industry push to eliminate sales on the web. You can get 11 pounds for $107 delivered to your door, and that's not bad considering retail market prices.... rover.ebay.com/rover/1/711-53200-19255-0/1?ff3=4&pub=5575339965&toolid=10001&campid=5338199104&customid=&mpre=https%3A%2F%2Fwww.ebay.com%2Fitm%2FR410a-R-410a-R-410a-Refrigerant-11lb-tank-New-Factory-Sealed%2F202661144956%3Fhash%3Ditem2f2f8ba97c%253Ag%253Au0YAAOSwz4Zc%257Er2V%253Asc%253AFedExHomeDelivery%252133990%2521US%2521-1%26LH_BIN%3D1

  • @balfome
    @balfome 3 หลายเดือนก่อน

    How do you add EasySeal Ultimate LS? Can you do a video on it?

  • @ahmedlz9495
    @ahmedlz9495 3 ปีที่แล้ว

    what is the mathematical relation between the PSI and the temperature cuz the right PSI must be read in 25 C° so how can i calculate the right psi in any given temperature ?

  • @mlwee6796
    @mlwee6796 3 ปีที่แล้ว +1

    Thsnks for showing how to open and close the valve. Can you make a video to show where the blue and yellow hose are connected.

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว

      Hey Mo! You are welcome! The other videos we uploaded cover that...... th-cam.com/video/RndlC9g5HzQ/w-d-xo.html and th-cam.com/video/b_aysEpNLes/w-d-xo.html

  • @georges2569
    @georges2569 4 ปีที่แล้ว +7

    On the yellow hose at the gauges don’t remove that hose just slightly open it up till you see the Freon coming out then just simply tighten it up and then proceed on what he’s describing you need to get the contaminated air out of your hoses first

    • @SaveGreenHere
      @SaveGreenHere  4 ปีที่แล้ว

      Correct. A split second is enough until you see refrigerant come out, so you can purge it.

  • @CasaDelGato
    @CasaDelGato 2 ปีที่แล้ว +1

    Failed recharge. sigh.
    I recently installed a new Senville 18K btu unit. Did a 1.5 hr vacuum test, no problem.
    Finished setup and started the system running. (note: It's winter!)
    It started heating just fine. Then I got a call and had to leave for six hours.
    Came back - and it wasn't heating anymore.
    Turned it off, and checked the Freon pressure. it was 0. Apparently the system developed a nasty leak somewhere.
    Since I had shortened the lineset (I only need about 20'), I assumed my flaring job wasn't good enough.
    Due to shipping snafus, I had a spare lineset (25'), so I just replaced my shortened one with a factory built one (and looped it).
    Since I had to wait for the Freon to arrive, I did a VERY LONG (4 day) vacuum test. It held vacuum.
    It's 36 deg F outside.
    Since there was no freon and I didn't want to run the compressor when empty, I did a slow fill to 100psi.
    Then powered up the system, and was able to fill it to 115psi. Wouldn't go higher. (freon too cold??)
    Yes, it's in Cooling mode - as I do have an alternate heat source in the house.
    Let it run for 15 minutes - no cooling, blower running inside, the fan on the outside unit is NOT running, but I can hear the compressor running.
    Pressure hasn't changed.
    Tried flipping it to Heat mode, and waited 15 minutes. No heating inside, inside blower running, outside fan and compressor running.
    No heat. Pressure hasn't changed.
    Gave up and shut it all down.
    Any suggestions?

    • @CHS10901
      @CHS10901 2 ปีที่แล้ว

      Did you open the valves from the compressor to the lines? Towards the beginning of the video, he said don't try and add refrigerant to these ports. Ask me why I know? Been there, done that. Once you have the lines all connected, take the caps off and open the valves on both the high and low, you should hear a hissing sound as the preloaded refrigerant goes from the compressor to the lines. Open the valves all the way until the stop and then see if you get the heating and cooling desired. This is somewhat off the top of my head recalling from a couple of years ago, but I think there was also set of a master valves on top of the individual ports on my unit as well, so you might want to check that as well.

  • @dew117
    @dew117 2 ปีที่แล้ว

    Thank you for for sharing .
    The best practice for mini split is to start from zero ... Pull the vacuum and add refrigerant by weight.
    Anyway, I also top up my 9000 BTU gree inverter..
    During topping up, I keep monitoring
    psi on the gauge,
    current from the clamp meter ,
    temperature on suction line ,
    temperature from supply vs return air on evap unit.
    I turn my ac to turbo mode or max cool... run for a while ...and adding refrigerant...
    My sweet spot
    Gauge psi.. 125-130
    Current getting close to RLA (it is ok for mini split to ramp up to RLA on turbo mode... We are not gonna keep using turbo mode all the time in real life, right?... The current will go down when on normal operation.
    Super-Heat keeps fluctuating in the range of 5 +-3, which is normal
    Delta T or return air temp minus supply air temp on the evap indoor unit is between 15-20 degreeF

  • @ShannonRawls
    @ShannonRawls 7 หลายเดือนก่อน +1

    Thanks for giving us the game!

  • @turnerfam540
    @turnerfam540 2 ปีที่แล้ว +2

    Just found your channel, and absolutely love the content!! I have an LG24k three zone unit. Would I be able to use this same process and shoot for the 117-120 psi? Thanks so much! Subscribed!!

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว

      There have been some variations with some manufacturers and models, so look at the manual. It's there on the ones we have installed.

  • @dhuff9844
    @dhuff9844 2 ปีที่แล้ว +1

    Thank you!!

  • @wasimedoo7994
    @wasimedoo7994 ปีที่แล้ว +1

    Very good information what size of AC you put the Freon in and what was the in temp

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว +1

      That was a 9000 BTU system and the temp was around 100 degrees in the Summer.

  • @ericboisselle1145
    @ericboisselle1145 ปีที่แล้ว +2

    thank you help me a lot!

  • @janvanderlinde3039
    @janvanderlinde3039 2 ปีที่แล้ว

    to the < is open to the > is close🤣

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว +1

      All valves closed except the blue one. Best practice is to vacuum out the lines, done before video). Weight the refrigerant on a scale, according to what the label on your unit says, Example, 1.5 pounds. Slowly, open the blue valve, and let the unit run on cool, and open the blue valve and allow some refrigerant, and let the unit stabilize for 15 minutes. Adding refrigerant is a step that requires patience, and the proper tools. Unfortunately not many have either, lol.

  • @dangerdoberman
    @dangerdoberman 11 วันที่ผ่านมา +1

    Whoa. That's really great.

  • @ricardoresendiz5460
    @ricardoresendiz5460 2 ปีที่แล้ว

    muy buen video carnal gracias por allí darle a la gente gracias

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว

      A la orden Ricardo y gracias por suscribir

  • @nickaltvater5592
    @nickaltvater5592 3 ปีที่แล้ว

    Had to believe our getting more than a 50° drop in temps.
    It's 88°outside. I'm getting 45° out of my vents. What I find odd is that my evaporator coils are at 60°.

  • @patmac
    @patmac 2 ปีที่แล้ว

    Great Vid Thanks. Any other suggestions for sourcing 410A. The like above is dead. Tx

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว

      You have to click the second link in the video description where a bunch of related links are at. Here it is anyway....... ebay.us/YKjza2

  • @lifegreats
    @lifegreats 3 ปีที่แล้ว +1

    Hello, great video and would be easy to do here in the summer however it is winter right now. Can this process be used while the unit is running in heat mode? If so, what pressure should I look for when in heating mode. According to your video, the sweet spot is 117-120psi when running in cool mode.

  • @jjhydrama
    @jjhydrama หลายเดือนก่อน +1

    i did not know you can add as liquid to the gas side .

  • @johnjames9821
    @johnjames9821 ปีที่แล้ว

    Is this 470a compatible with the r410a that is already in my machine or do I need to do a complete purge and change over? thanks

  • @ADEHMMO
    @ADEHMMO 2 ปีที่แล้ว

    Hi,
    Should the AC be off when doing this ? And thanks for the amazing video. It's crystal clear.

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว +1

      Needs to be on, and in cooling mode.

  • @abujabi
    @abujabi 2 ปีที่แล้ว +1

    Do you need to have your unit running while you're charging this to get the right pressure readings?

  • @fishycomics
    @fishycomics 4 ปีที่แล้ว +1

    Thank you. a great Reference to doing things: I have the gauges adapter and 410A thanks to a friend. i have fujitsu AOU24RML1 4lb. Design pressure High side 450, low side 240 It has two 9KBTU units to one machine? I should add to 240 psi if I am LOW. I'll look for one with the same machine to help on. appreciate some advice

    • @robertberin4872
      @robertberin4872 2 ปีที่แล้ว

      If you have removed all the refrigerant from the system than you should put back the specificfication weight of 410a.

    • @dannyluong9246
      @dannyluong9246 ปีที่แล้ว

      @@robertberin4872 what port do we have to use to fill up refrigerant? (for multi-zone unit).
      Thanks.

  • @jeremymoore450
    @jeremymoore450 ปีที่แล้ว

    Hi I have a ductless split pioneer a/c system and I believe it needs more refrigerant also. Where do you get it? can you use the stuff that works in automobiles or no? R-410A? the link for the small bottle doesn't work that you posted above?
    Thanks,
    Jeremy

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว

      Look at the side of your unit indoors, the label will tell you how much refrigerant you need. If you need 2 pounds or less, this is a good option...... ebay.us/UMOOEg but if for some reason you need more, like 5 pounds, try this one.... ebay.us/xWoD5Y and for 25 pounds, try this...... ebay.us/PQCoux

  • @deanroadifer6013
    @deanroadifer6013 ปีที่แล้ว +3

    If you go to the support section from the manufacturer of you mini split they will send you a chart showing the proper PSI needed according to the temperature outside and the temperature inside. This will be more accurate.

  • @newpass9434211
    @newpass9434211 8 หลายเดือนก่อน

    question, when your releasing the freon in increments..the 2 valves on the condenser..should they be open or close?..if you can please clarify.i appreciated. am just confused, because when your doing a vacuum to your system to make sure there ar no leaks, your suppose to have the valves closed, and then after open the 2nd valve for 5 seconds and close it again, and then remove the vacuum, and then you open both valves again..so for charging the unit, do they have to be open or close...thanks

    • @SaveGreenHere
      @SaveGreenHere  8 หลายเดือนก่อน

      When we did this, there was no refrigerant on the system, and it was vacuumed. We did another video on the vacuum process here on our TH-cam channel. Always best to use a scale as well. In this video, the tube of refrigerant was within an ounce of the total refrigerant the mini split label indicated for the system.

  • @mgladden2
    @mgladden2 2 ปีที่แล้ว

    Great vid! Hey No one has a video on removing part of the charge on a minisplit that has shorter lines than the built in charge was designed for. Can you please do one? I feel like it's just release the full charge into the lines, start the system, and slowly recover via the suction side of your manifold into a recovery tank while monitoring the scale until you reach the weight that matches the pre-charged weight minus the final weight your line length requires. Is that correct?

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว

      Yes, you can use a scale if there is some, you can recover it and use a scale. In this case, there was ZERO refrigerant on this system.

  • @ericboisselle1145
    @ericboisselle1145 ปีที่แล้ว

    Thanks!

  • @spiderstone
    @spiderstone ปีที่แล้ว

    If I'm just checking does it need to be running to check how much is in there?....I went to check it and it really came out...should I check it when not running..thanks subscribed

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว +2

      Yes, it needs to be running, and on COOLING mode.

  • @thomasrogers7614
    @thomasrogers7614 2 ปีที่แล้ว

    Brilliant 👏

  • @leevogel9487
    @leevogel9487 2 ปีที่แล้ว

    When I removed that adapter I lost a bunch of freon and oil on my new mini split, should I add a little more oil? And do I add freon if needed with the outside unit on or off? Sorry for the questions I do not want to mess this up.

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว

      ALWAYS add wit unit running in cooling mode. You will always lose a bit when removing the fitting. Nothing major.

  • @Apollo_Music
    @Apollo_Music ปีที่แล้ว +2

    My two pounder ran out during the fill. It read zero and got it up to 105. It's working but I might have a leak

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว

      Get this.... amzn.to/3VoUy9N and see the video on how to use it here.... th-cam.com/video/hQjOhWkGmM4/w-d-xo.html

  • @paxlepham
    @paxlepham 3 ปีที่แล้ว +2

    Thank you for your refrigerant. I have ordered a 5 lb tank. My question is do we need to turn the A/C on while we charging.

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว +3

      Yes you do

    • @paxlepham
      @paxlepham 3 ปีที่แล้ว +1

      @@SaveGreenHere thank you so much. And another question, i have a problem with my liquid line that was leaked and lose all the refrigerant inside the hole. After that my inside unit has some noise. Hence i need to fix my liquid line and cleaning the liquid line of the insides unit. Could i pump down like the way you show on the other video and fix the liquid line?

  • @williamwintemberg
    @williamwintemberg 27 วันที่ผ่านมา +2

    For the occasional DIYer: A Safety Note: Wear gloves, a long sleeve shirt and a faceshield when connecting and disconnecting the lines. This stuff gets cold and can cause frostbite or loss of an eye.

    • @SaveGreenHere
      @SaveGreenHere  27 วันที่ผ่านมา +1

      Yes! Gloves: amzn.to/3Rfg5SL Faceshield: amzn.to/3VATnaC

  • @ABcustomflooring
    @ABcustomflooring 2 ปีที่แล้ว

    Can you tell me why side panel on mr cool says design pressure low 340psi and hi 550?
    Is it going to be 340psi rather than 120?

    • @SuperCano1997
      @SuperCano1997 2 ปีที่แล้ว

      340 and 550 is the high side..the suction line ( vapor) is 120..

  • @vegasromaniac
    @vegasromaniac 3 ปีที่แล้ว

    Great to know

  • @mytubeyear2009
    @mytubeyear2009 2 ปีที่แล้ว

    Great video, Thank You! What fan speed do you run the inside unit at while checking and adding refrigerant?

  • @HSQ786
    @HSQ786 ปีที่แล้ว

    have a blessed day...i need help..i have Mitsubishi aircon 1.5hp inverter, now very low cooling, i wanted to fill up gas, i checked with gas gauge pressure is in 140psi, but in this video showing should be max 120psi...i m confuse now.... please guide me, thanks

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว

      Depends on the size of your unit. The side of your unit should have a label that tells you how much refrigerant goes into that particular system.

  • @daviigs
    @daviigs 3 ปีที่แล้ว

    What would be the sweet spot if I have 1 condenser and 5 air handlers?

    • @glenmoore8494
      @glenmoore8494 3 ปีที่แล้ว

      its f5 different lines so each line would be 117-120

  • @crennie6928
    @crennie6928 4 ปีที่แล้ว +3

    Thanks for the informative video. Just have a question about any possible air in the system or line when you attach the canister to the unit. Is there anything or any way to bleed out the slight amount of air that is in the line/hose before the refrigerant is added? Thanks!

    • @SaveGreenHere
      @SaveGreenHere  4 ปีที่แล้ว +1

      Put ball valves on, like these.... amzn.to/2Q0jO81

    • @crennie6928
      @crennie6928 4 ปีที่แล้ว

      @@SaveGreenHere I have not seen those, but that seems like a great way to do it. Thanks!

  • @taiwanluthiers
    @taiwanluthiers 10 หลายเดือนก่อน

    I found pressure to be really unreliable on a mini split, especially if it's something with an electronic expansion valve, as they will adjust both the subcooling and superheat on the fly for optimal condition...
    Mine doesn't have electronic expansion valves, just capillary tubes, but I did it by pressure and feels like I might have overcharged it, as the compressor started becoming harder and harder to start, and dropping the charge (recovering refrigerants) fixed it. When this is done, the AC is cooling better but also the compressor hard start problem disappeared. However on the R22 system the pressure is reading to around 40 psi (which corresponds to a saturation temperature of about -10C), and it would never go above that, but any attempt to try and go over that either resulted in weakening the compressor or even seizing it up. I think saturation temperature adjusts itself based on various operating conditions as well as fan speed (you really want a ton of airflow over the evaporator to get accurate reading). If you look inside a mini split condenser there's a capillary tube leading from the condenser coil before it comes out to the valves. I do not know why this exists but there is likely a reason for it. This does not exist in standard AC units with a TXV. I know some even do it by current draw, but again, it seems unreliable. Weight seems to be the most accurate way to do it.
    It feels like a mini split needs to be completely recovered and then have the charge weighted out.

    • @SaveGreenHere
      @SaveGreenHere  9 หลายเดือนก่อน +1

      Great points! Yes recovering completely and weighing is key, and mentioned in the video description.

  • @jonmax-np9ze
    @jonmax-np9ze 11 หลายเดือนก่อน

    I have a dual zone Mr Cool, was wanting to know do I add freon to both zones or does one zone recharge whole system.

    • @SuperOpinion8ed
      @SuperOpinion8ed 7 หลายเดือนก่อน

      Probably too late for you personally, but I have a trizone and the manufacturer said it’s three separate systems.

  • @jimc4731
    @jimc4731 ปีที่แล้ว +3

    Where can I buy a new port that you fill the unit through? It is that brass fitting attached to the AC unit. Mine has an extremely small leak under that large cap next to where you are filling in the video
    I found the leak with an infrared detector, very small but it does leak!
    Thanks if you can help!
    JIM

  • @andrewhicks211
    @andrewhicks211 2 ปีที่แล้ว

    Does the unit have to be running ? And how do you hook up the hoses with out loosing freon

  • @Thekingmaker
    @Thekingmaker 3 ปีที่แล้ว

    I really appreciate your videos, I have several mini splits that I have to charge and if you could help me clarify a few things I would be most thankful. I have several Idea air mini split ac/heat pumps to move, one 3 ton still blowing nice and cold and heats, one 2 ton that cools and heats but not like it used to, and a 1 ton that no longer heats or cools. I've watched your video on how to check the pressure and the other on recharging, these units have quick connect fittings so I dont think I can use the nylon sealant. My question is could you suggest a procedure on moving them, i.e am I to just close the line valves, disconnect the quick connect hoses, transport and reconnect everything, reopen the valves , puge air from hoses then follow your 2 videos , or am I missing some steps? Thank you in advance.....

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว +2

      You need to pump it down into the compressor. Then you can transport. Once transported to new location, make sure you use nylog at the connections if they are flared, or if welded, verify no leaks by following these steps with vacuum pump. On that video description, there is info on the pump you can use and other materials..... th-cam.com/video/b_aysEpNLes/w-d-xo.html

    • @Thekingmaker
      @Thekingmaker 3 ปีที่แล้ว

      @@SaveGreenHere thank you so much

  • @danielduran4537
    @danielduran4537 8 หลายเดือนก่อน

    Thanks for sharing

  • @ltgengr
    @ltgengr ปีที่แล้ว +2

    Is the sweet spot of 117-120 the same on all model/size split systems?

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว +1

      Depends on size of the unit, and the outdoor temps.

  • @jlatacela3239
    @jlatacela3239 ปีที่แล้ว

    Hey guys. God bless all.
    I hope someone can help me.
    I have a blue ridge mini split multi zone, last year works fine, but now is not cooling, there's not errors displayed in the indoor unit and not freezing pipes into the outside unit, i still think must be something with refrigerant load. Any idea how to fine a refrigerat load using the gauge.? I know for a single zone is about 117 to 125 psi. Is the same for a 4 zone minisplit?
    Thanks for any help.
    God bless America

  • @sarahmacisaac1
    @sarahmacisaac1 ปีที่แล้ว

    I bought the small tank and have a auto manifold but I can’t yellow hose is to big. What connect should I buy? It’s different from the one that hooks up to the mini split.

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว

      From what you mentioned, you need to have an adapter...... amzn.to/3AytMVa

  • @billyhsat
    @billyhsat ปีที่แล้ว +4

    You didn't talk about purging the system that I could find. How do you do that?

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว +2

      th-cam.com/video/RndlC9g5HzQ/w-d-xo.html

  • @peternguyen2776
    @peternguyen2776 3 ปีที่แล้ว

    Top informative video

  • @alfredoandroid357
    @alfredoandroid357 3 ปีที่แล้ว +1

    Thank you
    Thank you
    Thank you
    Following your steps i was able to fill my system
    I have 2 zones
    I hook up the gauge to the 1/4 inch pipe like you said and
    I was scare at first because when I hook up the gauge it was at 50 but when put it on cool and turn on the system it will drop too zero
    It didn't exactly match your video but I knew I didn't have a leak because I pressure test the system and ran a vacuum before
    So I just said fuk it and follow your video it was on cool and the system was running the gauge was at zero but as I put gas in the gauge will go up little by little until the gauge read 115-117 sweet spot
    Also I went to each unit and the air went from just cool air too actually cold air
    I think in your video the system probably had more gas then my system or maybe because my system is 2 zones that why its started at 0 when I ran it
    Thank you, I really appreciate the help, gonna check to see if you have a donate page like with PayPal want to send you $50 tip for your help bro

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว

      You are welcome! On your question, my Paypal is savegreenhere@gmail.com Thanks, much appreciated!

    • @alfredoandroid357
      @alfredoandroid357 3 ปีที่แล้ว

      Gonna send it tonight or tomorrow, thanks

  • @jamesmason45
    @jamesmason45 3 ปีที่แล้ว

    I would appreciate a response to Raimundo Vazquez's issue as I encountered a very similar issue.

  • @v2v589
    @v2v589 ปีที่แล้ว

    Can you please share the video on how to add 410A for traditional AC.

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว

      Similar process, just add on the suction line, the thicker one!

  • @alessandriaj7265
    @alessandriaj7265 4 ปีที่แล้ว

    How long can you store the refrigerant, if you buy it now and may need it when the AC is needed which would be in a few months from now here in Illinois.....we have 2 mini splits Gree brand, the one is good, no problems the newer model seems to be low on refrigerant at the start up of each summer which will be the third this coming year, we checked for leaks, tighten up the fittings and it's all good, just never did find where it's loosing it. It heats fine in the winter though. Luckily we have a friend that an AC guy and he comes by to fill it for about $100 each time, but this would be nice to have handy instead.

    • @SaveGreenHere
      @SaveGreenHere  4 ปีที่แล้ว

      No, refrigerant will not go bad. As long as you have a fully sealed cylinder and there are no leaks on the cylinder you refrigerant will last indefinitely. ... Other than that your cylinder is a sealed unit and will not deplete or leak any refrigerant over its lifetime. If "your friend" is charging you $100 "each time" he comes, he's probably adding a pound, two, or three pounds. Get 25 pounds for $110 and do it yourself MANY TIMES OVER with this jug....... ebay.to/38U1yn8 If you need gauges, the link on the description has the best priced one.

  • @zu1502
    @zu1502 18 วันที่ผ่านมา

    Do you do this when the system is on and running? Also do we vaccume the system when it's on or off? I vacuumed the system when it was of with both valves open that releases the freon then I closed it back up

    • @SaveGreenHere
      @SaveGreenHere  14 วันที่ผ่านมา +1

      Yes, up and running, and only in cooling mode!

  • @lyonnnnnnnn8
    @lyonnnnnnnn8 3 ปีที่แล้ว

    Can I use this 410a refrigerant for a senville split unit? Thanks

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว

      Yes, absolutely. The label on your Senville should read "410a" under refrigerant type, so just verify that.

  • @marilynmiller2132
    @marilynmiller2132 2 ปีที่แล้ว

    Gauges on Amazon have arrival date of late July 2022. Are there other gauges that you recommend?

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว

      These are literally next day...... amzn.to/3GOvOC1

  • @anonymoose1269
    @anonymoose1269 2 ปีที่แล้ว

    Is such a large tank of refrigerant needed? How much does the unit acutally take from the 25lb tank link you provided?

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว

      How many BTU is your system? All depends on size, and if you will need some again in the future, if you did not properly seal the leak.

  • @shanefrank3281
    @shanefrank3281 ปีที่แล้ว +4

    I thought with inverter systems the fan speeds, compressor speed and metering device are constantly changing so you weren't able to tell the state of charge by just looking at the pressure (or the superheat and subcooling) like you can with a single speed system.

    • @spazzman90
      @spazzman90 11 หลายเดือนก่อน

      You are correct. I'm not sure he mentioned this being an inverter system. That being said, I'm installing a couple of inverter systems. I forgot I wanted to check pressure running at full speed. I will do that when I'm finished installing the second system.

  • @nickwolfenbarger7002
    @nickwolfenbarger7002 2 ปีที่แล้ว

    Does compressor have to be on when you are checking those pressures?

  • @Seriousgreeen
    @Seriousgreeen 2 ปีที่แล้ว

    if I make a mistake can it cause an explosion? concerned about bodily harm. , must the unit be on or off when you do this?

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว

      Must be on. Done properly if you get the amount of refrigerant based on the label, and use a scale to get the right weighted amount. Use one like this..... amzn.to/3tevpmF

  • @hangsu5724
    @hangsu5724 4 ปีที่แล้ว +1

    Thanks a lot for your video. It is really helpful. I have a R410A refrigerant FUJITSU minisplit with model AOU24RLXFZ. In the label, it said design pressure high side:450psi low side:240 psi. It looks the lower sider PSI is pretty much higher than your normal 120 psi. Currently, my low side pressure is 125 PSI and AC is not cool enough. Does it mean I need to add more refrigerant to achieve 240 PSI on lower side?

    • @AlekseySmolenchuk
      @AlekseySmolenchuk 4 ปีที่แล้ว

      Same question, I'm seeing Hi 550 PSIG and Lo 340 PSIG on a Senville 09CD

    • @jimcroft1387
      @jimcroft1387 4 ปีที่แล้ว +1

      @@AlekseySmolenchuk Those are test pressures.