Distance between Columns | Maximum and Minimum distance between columns | RCC Column Distance

แชร์
ฝัง
  • เผยแพร่เมื่อ 17 ต.ค. 2024
  • Hi All!!, This video explains about distance between columns,factors needs to consider to fix the distance between columns,Maximum and Minimum distance between columns without thumb rule.
    Please refer the below links for other column related videos
    1.Column Orientation for buildings
    • Column Orientation | C...
    2.Major and Minor axis of the column
    • Major and minor axis o...
    3.Axial load,uni-axial,bi-axial bending
    www.youtube.co....
    4.Design & detailing of column axial load with uni-axial bending
    www.youtube.co....
    5.Slenderness ratio & minimum eccentricity in column as per IS codes
    www.youtube.co....
    6.Practical provisions of column as per IS codes
    www.youtube.co....

ความคิดเห็น • 86

  • @japet319
    @japet319 4 ปีที่แล้ว +4

    This are simple yet very important things to consider...they never mentioned this when I was in college. I am so much lucky I found your youtube channel...by the way, I subscribed and thanks so very much.

  • @mohdyusuf6819
    @mohdyusuf6819 4 ปีที่แล้ว +1

    mam realy ur explanation is very good

  • @riazm.i8110
    @riazm.i8110 4 ปีที่แล้ว +2

    hi mam,
    is it compulsary to put 4 columns around the lift?
    cant we support it by only beams, if not able to provide columns?

    • @AbdulRaheem-kk8kv
      @AbdulRaheem-kk8kv 4 ปีที่แล้ว +1

      Columns are necessary because it bears gravity loads and lift weights. So shear walls are provided. As lift is dynamic loading equipment

    • @charlesrongo3615
      @charlesrongo3615 ปีที่แล้ว +1

      lift it self is the best on carring loads gravity than columns sometimes no need to put colmns , shear wall can handle gravity loads too.

  • @raghuprasath7631
    @raghuprasath7631 3 ปีที่แล้ว

    What is the distance between two columns for room size 11*8 pareller another room is same. I asking column size.

  • @narendrarbhagyaa1012
    @narendrarbhagyaa1012 3 ปีที่แล้ว

    mam can we provide 6"x15" column if load is 40t can you plz explain column design

  • @franciscruz869
    @franciscruz869 4 ปีที่แล้ว +2

    MAM ITS VERY HELPFUL THANKS ALOT MAM WE HOPE FOR ALOT OF CONTENT .
    CAN U DISCUSS ABOUT THE RADIAL PLANNING OF COLUMNS AND FRAMMING
    AND COLUMN ARRANGEMENT FOR AUDITORIUMS.

  • @shahameednet
    @shahameednet 4 ปีที่แล้ว +1

    Excellent

  • @BNuwan123
    @BNuwan123 4 ปีที่แล้ว +1

    do i need to follow these limtation while i can use etabs software for structure modeling.....?

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว +1

      Distance between columns will not change with software.It depends on the building plan and framing of the structure.

  • @rajudeb8706
    @rajudeb8706 4 ปีที่แล้ว

    for residential building G+2 storey if we don't have the soil data..than what should be the dimensions for structural member like column and beam..

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว +1

      It is not advisable to design the structure without knowing the nature of soil.Foundation is very important for any structure.

  • @silarshamohammad2059
    @silarshamohammad2059 4 ปีที่แล้ว +1

    good topic madam .....glad to know from you thank you.

  • @jonahnewmai1428
    @jonahnewmai1428 4 ปีที่แล้ว

    Mam, is 15'x15' column to column safe? What will d depth of d beam n column of 15'x15' and 12x13'? Will they b same ?

  • @kabirmuhd9615
    @kabirmuhd9615 3 ปีที่แล้ว

    Good one, it's really helpful

  • @edwindacara3581
    @edwindacara3581 ปีที่แล้ว +1

    Nice

  • @yedukondalugeedimalla
    @yedukondalugeedimalla 4 ปีที่แล้ว

    Mam which software you are using. For that photos

  • @sanjeevreddy1756
    @sanjeevreddy1756 4 ปีที่แล้ว

    Mam what are the checks we need to verify for slab,beam,colums,footing whether our design is corect or not in staadpro?

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 ปีที่แล้ว +1

    many you tube channels are made by quakes .but this is really from a structural engineer .

  • @sheetalharapanahalli4954
    @sheetalharapanahalli4954 2 ปีที่แล้ว

    Pls make video on manual calculation of pu for column design

  • @poojaprasad6094
    @poojaprasad6094 4 ปีที่แล้ว

    what will be the coloums dimension for 9m span area

  • @rameshreddykakani6736
    @rameshreddykakani6736 4 ปีที่แล้ว

    It's nice & informative and if you have prepared any video on fixing of orientation of columns for a large spans ( upto 10 mtr ) building .Pl share.

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว

      Thank you.
      Please refer the below link for column orientation
      th-cam.com/video/xFrHDJLoSr4/w-d-xo.html

  • @johncadengineering9746
    @johncadengineering9746 4 ปีที่แล้ว

    which software do you use

  • @billapativenubabu8623
    @billapativenubabu8623 4 ปีที่แล้ว

    On What Basis we will decide Tributary Area?. Can you pls tell me.

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว

      We provide columns with grids.The column load varies with position, grid size and intended use. Generally, the internal column carries 100% grid area, side column carries 50% of grid area and corner column carries 25% of grid area.

  • @EvergreenConsultancy
    @EvergreenConsultancy 4 ปีที่แล้ว

    Mam, Not related to this topic- Except for column C2 and C7, rest all column Orientation is not correct?

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว

      It is not like that.Orientation will not be same for all structure.

    • @EvergreenConsultancy
      @EvergreenConsultancy 4 ปีที่แล้ว

      @@CivilEngineeringMastery yup, but what I meant was, won't these column fail in EQ?

  • @engineerdude8480
    @engineerdude8480 4 ปีที่แล้ว

    Hello, please can you confirm it by using a software?

  • @Sanjayasuresha
    @Sanjayasuresha 4 ปีที่แล้ว

    columns around lift, doesn't they prefer shear wall in 3 sides other than the door opening?

    • @oscardavis2438
      @oscardavis2438 3 ปีที่แล้ว

      i guess Im asking the wrong place but does anyone know of a method to log back into an Instagram account..?
      I was dumb forgot my password. I would love any tricks you can offer me!

    • @korbynavi7940
      @korbynavi7940 3 ปีที่แล้ว

      @Oscar Davis Instablaster =)

    • @oscardavis2438
      @oscardavis2438 3 ปีที่แล้ว

      @Korbyn Avi thanks for your reply. I found the site thru google and I'm waiting for the hacking stuff now.
      I see it takes a while so I will reply here later when my account password hopefully is recovered.

    • @oscardavis2438
      @oscardavis2438 3 ปีที่แล้ว

      @Korbyn Avi it worked and I finally got access to my account again. Im so happy!
      Thanks so much you saved my account !

    • @korbynavi7940
      @korbynavi7940 3 ปีที่แล้ว

      @Oscar Davis you are welcome :D

  • @madhukarchauria
    @madhukarchauria 4 ปีที่แล้ว

    Ma'am if our column to column distance is 15'5''X11' and it column size is 9x15 so ma'am plz tell me what should be the depth of beam is provided including in slab in this requirement.?

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว +1

      Is it a residential building?

    • @madhukarchauria
      @madhukarchauria 4 ปีที่แล้ว

      Yes ma'am ...

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว +1

      Approximately consider 15' or 18 ' beam depth for 15' column to column distance.But do the analysis and cross verify the beam depth.

    • @madhukarchauria
      @madhukarchauria 4 ปีที่แล้ว

      Ma'am as per your suggestion the beam depth is 15 inches so. it is included the slab thickness or not?

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว +1

      Beam depth 15" to 18"

  • @Dr.Earthworm
    @Dr.Earthworm 4 ปีที่แล้ว

    I would say this is not completely correct based on the stability and earthquake loads as there should be one more column between the beams B5 and B2, which is an axial loaded column because of the gravity point of view. there would be too much deflection if there is no axial column in the middle.

  • @ajinleo614
    @ajinleo614 3 ปีที่แล้ว

    Thank you

  • @saifeetarwala7725
    @saifeetarwala7725 4 ปีที่แล้ว

    Please make a video on Limit State and Working stress method, explain the difference and which is used where?

  • @ar.avadheshsingh2616
    @ar.avadheshsingh2616 4 ปีที่แล้ว +1

    What is the minimum size of column and one minimum dimension of column

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว +1

      Minimum size 9"X 9"
      If it is a rectangular column 9"X 12" , 9"X 15" ,9" X 18" .....
      Size of the column depends on loads coming on the structure , type of the structure etc.

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 ปีที่แล้ว

    madam can you explain the design of beam under a. A simply supported beam supporting a sunshade of more than 1m .
    how to check whether the beam is stable . how to design. the slab.beam .what care to be taken so that the beam is stable
    b. a beam supported by columns and supporting a cantelever sunshade slab of more than 1m .
    how to find the effecr of sunshade on beam
    beam on column ,column on footing

  • @easywayoflandsurveyingwith5125
    @easywayoflandsurveyingwith5125 2 ปีที่แล้ว

    How i calculate proper beam and column size

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 ปีที่แล้ว

      Please refer to the below link
      Column size
      th-cam.com/video/NV5k1RjrPiM/w-d-xo.html
      Beam size
      th-cam.com/video/CdPXPj9KWFk/w-d-xo.html

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 ปีที่แล้ว

      I have created a course, structural design of buildings using Etabs software which includes structural analysis and design of a five-sorey RCC building(Real project) and is now available on udemy.
      Kindly use the below link to avail the full course.
      www.udemy.com/course/structural-design-of-buildings-using-etabs-software/?referralCode=14883FDBBD95A1ADAC02

  • @narendrarbhagyaa1012
    @narendrarbhagyaa1012 3 ปีที่แล้ว

    mam how to join i am not able to join

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 ปีที่แล้ว

    Madam
    How many videos are published by you.

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว

      th-cam.com/users/CivilEngineeringMasteryplaylists?view_as=subscriber
      please check my platlist

  • @renurayal2693
    @renurayal2693 2 ปีที่แล้ว

    So should be the size of B2 and B5

  • @johnnyoptimist007
    @johnnyoptimist007 4 ปีที่แล้ว

    Hi, it was informative but can you please put another video on coloumn and beam size based on the distance.

  • @shyeestanaj9785
    @shyeestanaj9785 4 ปีที่แล้ว

    good information.

  • @Roundtheclock0
    @Roundtheclock0 3 ปีที่แล้ว +1

    Jaher Understand 😂😂😂🔥

  • @aslahaslu4320
    @aslahaslu4320 4 ปีที่แล้ว

    👌

  • @athikahammad1048
    @athikahammad1048 4 ปีที่แล้ว

    Pless give moree information

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 ปีที่แล้ว

    madam please give a reference code for your videos . so that we can record it and also refer to others in a sequence .at least give a serial number for your videos.

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว +1

      please refer play list in you tube channel.The same you can refer to others.

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 ปีที่แล้ว

      Playlist link
      th-cam.com/channels/zx4R_ldeFp5vT25KyAyyQg.htmlplaylists?view_as=subscriber

  • @dinnabharath2201
    @dinnabharath2201 4 ปีที่แล้ว

    Minimum size of beam

  • @BNuwan123
    @BNuwan123 4 ปีที่แล้ว

    etabs is designed to do this

  • @abdurahman6890
    @abdurahman6890 3 ปีที่แล้ว

  • @civilengineerkhokan2521
    @civilengineerkhokan2521 2 ปีที่แล้ว +1

    Nice

  • @ashokkurusamy861
    @ashokkurusamy861 4 ปีที่แล้ว +2

    Nice

  • @dhanishvlog6595
    @dhanishvlog6595 4 ปีที่แล้ว +1

    Nice