E5: Column Rebar Cutting List with Splicing (Lapping Length, Lapping Zone)

แชร์
ฝัง
  • เผยแพร่เมื่อ 31 ก.ค. 2021
  • Sa Episode na ito, gagawa tayo ng rebar cutting list para sa column ng 4 storey building.
    E discuss natin dito ang Lapping Zone, Lapping length, Staggered lapping.
    Ito ung link para sa mga plano from DPWH na pwedeng e download at pag aralan ng mga estudyante ng Civil Engineering at sa mga Civil Engineer na kaka graduate lang at nag hahanap ng work.
    www.dpwh.gov.p...

ความคิดเห็น • 33

  • @htcYofi
    @htcYofi 2 หลายเดือนก่อน

    As an American, thankyou so much for this, and speaking taglish very much appreciated po ❤

  • @kimalejandrino2968
    @kimalejandrino2968 2 ปีที่แล้ว +1

    Thank you, Sir. This is very helpful po!

  • @gnidnoeled786
    @gnidnoeled786 ปีที่แล้ว +2

    Ang ibig sabihin ng 50% ay ang pagkakaroon ng splice sa isang location alternately. Then yung remaining 50% ay sa ibang location, naka-offset sa unang 50%.

    • @nicekachoi
      @nicekachoi หลายเดือนก่อน

      Kailangan po ba tlga nasa ibang floor level ang other 50%?

  • @justjey1148
    @justjey1148 6 หลายเดือนก่อน

    Thank you sir. Big help

  • @michaeljamesomboy951
    @michaeljamesomboy951 ปีที่แล้ว +1

    Sir thank you po nang marami sa video. Nadagdagan at naclarify po yong knowledge ko about sa rebar. Ask ko lng po if no need naba 90 deg hook sa top end nang bakal? Kasi ini insist nang qc na dapat meron talga, kaso sa cutting list na hindi naman naka indicate. Thanks po nang marami.

  • @giselleanndemana5210
    @giselleanndemana5210 ปีที่แล้ว

    thank you Sir!!!!

  • @marjunnapuli9661
    @marjunnapuli9661 3 ปีที่แล้ว +1

    When you say H/2 parang hinati mu yung column.
    I suggest when you say half of the lapping zone I would prepare to say, Lapping zone = Height minus 1/4H sa taas at 1/4H sa baba para yung matira lapping area gitna tlaga.🙂

  • @PtPt-zl1qe
    @PtPt-zl1qe 2 หลายเดือนก่อน

    Goldf pitch fa ibs unit pungpond.bottom lock.or pinhing wall.fame.Hbra.vibrobreak to top.20×40cm.fame strand sinkzink alumlonndon.pipe lg fame.steel .in hight 2.40m.fame spacer in locklock.bar 2C chaneel.soilid.fillet.pic

  • @felen4261
    @felen4261 7 หลายเดือนก่อน

    Subscribed :)

  • @shawarmarice2364
    @shawarmarice2364 ปีที่แล้ว

    @ 21:19 sir ang ginamit nyu po kasing lap length is nag exceed sa minimum require ment ng plano ang sabi po doon "less than 40 bar diameter" so dapat less than 1m ang lap length kaya kung sakaling .9m ang gamiting lap length pasok po sha sa .6m na istance between adjacent bars

    • @shawarmarice2364
      @shawarmarice2364 ปีที่แล้ว

      and acceptable din if yung nasa table under compression ang gagamitin

    • @angsanlaton9348
      @angsanlaton9348 9 หลายเดือนก่อน

      parang mali yata yong "shall be less than 40d". Kasi ibig bang sabihin nun pwedeng 1mm splice db less than 40d yon? Sa tingin ko na typo lang yong nag autoCad dun "shall NOT be less than 40d" ang alam ko kasi sa ibang mga youtuber sabi nila ang lap splice is 40d to 60d hindi 0 to 40d.

    • @marklawrenceranollo5677
      @marklawrenceranollo5677 หลายเดือนก่อน

      ​@@angsanlaton9348 Pagkaka intindi ko is "shall be less than 40D" but no less than the value indicated in the table under compression. So ung sabi mo na pwede mag 1mm kasi pasok naman sa less than 40D pero di siya pasok sa length indicated sa table under compression.

  • @arvinhinyerotv4651
    @arvinhinyerotv4651 ปีที่แล้ว

    Parequest po cutting list sa stairs

  • @anthonybenitez673
    @anthonybenitez673 4 หลายเดือนก่อน

    engr paano mo po nagawa yung elevations? mano mano mo po ba yang drinawing sa cad?

  • @kejtejada8867
    @kejtejada8867 2 ปีที่แล้ว +1

    Hi po, sample estimate din po for round columns, formworks, at trusses. Sana manotice 👋 (done subscribing 😅)

  • @marjunnapuli9661
    @marjunnapuli9661 3 ปีที่แล้ว +1

    Please include quantity in excel po.. slamat

  • @shawarmarice2364
    @shawarmarice2364 ปีที่แล้ว

    what do you mean po by "splice length shall be less than 40 bar diameter"?

    • @shawarmarice2364
      @shawarmarice2364 ปีที่แล้ว

      multiply pala 40 by the diameter size in meter (unit) ahahaha

  • @ginengineerkamote3815
    @ginengineerkamote3815 2 ปีที่แล้ว +1

    Hello po engineer. May I know po saan ka nakadownload ng ganyan. Newly grad po thanks

  • @norjihads.4144
    @norjihads.4144 ปีที่แล้ว

    Sir much better siguro kung medyo lakasan ang audio 😅😅

  • @jhaysoncarlchui6824
    @jhaysoncarlchui6824 2 ปีที่แล้ว

    Hindi mabasa 🤦🏻‍♂️💔

  • @jasonmahinil8276
    @jasonmahinil8276 3 ปีที่แล้ว +1

    Boss mejo pakilakasan sguro ung audio? 😀

  • @pogi6479
    @pogi6479 3 ปีที่แล้ว

    engineer po ba kayo sir?