E6: Beam Rebar Cutting List with Splicing (Lapping Length, Lapping Zone)

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 ส.ค. 2021
  • Sa Episode na ito, gagawa tayo ng rebar cutting list para sa suspended slab ng 4 storey building.
    E discuss natin dito ang Lapping Zone, Lapping length, Staggered lapping.
    Ito ung link para sa mga plano from DPWH na pwedeng e download at pag aralan ng mga estudyante ng Civil Engineering at sa mga Civil Engineer na kaka graduate lang at nag hahanap ng work.
    www.dpwh.gov.ph/dpwh/node/12515

ความคิดเห็น • 54

  • @jeffreygalanza2813
    @jeffreygalanza2813 2 ปีที่แล้ว

    Very informative.

  • @MarvinAsica-ci1xc
    @MarvinAsica-ci1xc 11 หลายเดือนก่อน

    I'm very satisfied sir thank you sa learning's 😊

  • @hyacinthvlog8380
    @hyacinthvlog8380 2 ปีที่แล้ว

    Ok ka po,salamat po sa pagtuturo mo malaking bagay po ito sa aming hindi pa marunong,,,

  • @jhanromanopis7695
    @jhanromanopis7695 ปีที่แล้ว +1

    Mechanical Engineer ako pero naiintindhan ko yung pag turo. Galing magturo, thank you sir. 👌👏👏

    • @harrytv8302
      @harrytv8302 10 หลายเดือนก่อน

      What is the 1st law of thermodynamics?

  • @julsvlogtv1991
    @julsvlogtv1991 2 ปีที่แล้ว

    thanks for sharring.. sir new subscriber. nyopo 🙏🏾🙏🏾

  • @avachar11
    @avachar11 2 ปีที่แล้ว

    Thank you sir. Helpful po. Gawa po kayo playlist sir. Thank you.

  • @hydrogenperoxide9995
    @hydrogenperoxide9995 2 ปีที่แล้ว +2

    I have to say that this video is worth the effort. For the first 15 minutes, marami na kaagad akong knowledge na napulot. Keep it up sir!

  • @brianmars465
    @brianmars465 4 หลายเดือนก่อน

    Salamat sir

  • @solsticebeat
    @solsticebeat 2 ปีที่แล้ว +3

    regarding sa tanong nyo kung pwede ba magsplice sa
    bandang column, pwede daw po kasi under compression
    naman aang bottom bars sa support. pero d ko pa po
    ginagawa yun. iniisip ko paano na yung lap length nun kung sakali… kasi may provision na bawal mag splice a distance of twice the beam depth from the face of the support.

  • @franciscotanjusay3249
    @franciscotanjusay3249 6 หลายเดือนก่อน

    salamat bro. bilang foreman ang ginagawa ko sa bottom bar L/5 mula sa mukha ng bega kc kong sa loob ng poste ka kapal nga bakal dahil may ibang bega ang dadaan at sa top bar naman po ay L/2 diyan ako ng dudugtong at madalas kupo gawin sa mga gusali na ginagawa namin. salamat po

  • @digifilesonlineshop3977
    @digifilesonlineshop3977 2 ปีที่แล้ว +1

    Thank you sir!

    • @pinoycivilengineerkonstruc3515
      @pinoycivilengineerkonstruc3515  2 ปีที่แล้ว

      Maraming salamat Sir!

    • @pinoycivilengineerkonstruc3515
      @pinoycivilengineerkonstruc3515  2 ปีที่แล้ว +1

      Hope you can watch it po.
      Salamat po.
      EP8: Three Storey Slab Rebar Cutting List with Splicing (Lapping Length, Lapping Zone)
      th-cam.com/video/-z42qsQBG0Q/w-d-xo.html

    • @vhalallauigan397
      @vhalallauigan397 2 ปีที่แล้ว

      Pa help po sir 2 story haws 5m x7m may asinta na sir tapus poste pero walang second beam sa grown floor sir pa help po tnxsir

  • @reymacadangdang9916
    @reymacadangdang9916 ปีที่แล้ว +1

    In addition, to beam lapping zone, L/4 both top bar & bottom bar.😊

  • @reymacadangdang9916
    @reymacadangdang9916 ปีที่แล้ว +1

    Pwede Sir sa column ang splice, but note, the development length from the face of the column

  • @gnidnoeled786
    @gnidnoeled786 ปีที่แล้ว +5

    Hindi pwedeng maglap-joint sa column zone. Ang splicing zone sa bottom bar ay tama sa L/4 pero iiwasan ang 2H from face of support.

  • @jeromebalberde2186
    @jeromebalberde2186 2 ปีที่แล้ว

    galing sir more video pa po. sana slab naman po one way two way

    • @pinoycivilengineerkonstruc3515
      @pinoycivilengineerkonstruc3515  2 ปีที่แล้ว +1

      Hope you can watch it po.
      Salamat po.
      EP8: Three Storey Slab Rebar Cutting List with Splicing (Lapping Length, Lapping Zone)
      th-cam.com/video/-z42qsQBG0Q/w-d-xo.html

  • @engr_ry
    @engr_ry 3 หลายเดือนก่อน

    question sir, for bottom bars po, since may provision po tayo na 2d or 2h away from column is an area prohibited mag-splice due to lateral forces, meaning liliit ang splicing area, sa instances na ganito, paano ang gagawin the moment na yung splice length ay greater than sa remaining splice area? i-e-extend ba to midspan yung splicing area to compensate and satisfy the splicing length and splicing area?

  • @pong3753
    @pong3753 2 ปีที่แล้ว +7

    Dba sir Sa structural code naten or sa NSCP bawal mag splice sa may 2d or 2h kasi sa lateral movement pag nag earthquake?

    • @thomcayabyab8627
      @thomcayabyab8627 2 ปีที่แล้ว

      Yung inexplain ni engineer at Sa end support Yan ang dulo Ng mga extra rebars. ..Pero Yung pagdating Sa splicing Ng mga horizontal rebars at 2d or 2h ang di pwede magslice po...

    • @HanzotheSalamander.
      @HanzotheSalamander. ปีที่แล้ว

      tama bawal yun

  • @oirgubatana8780
    @oirgubatana8780 2 ปีที่แล้ว

    Sir paano nmn ang lap splice dun sa Web bar ilang dia. at saan ang location.

  • @constructionworksideas
    @constructionworksideas 2 ปีที่แล้ว

    Engr.ok lang po ba taasan ang height ng 2nd floor,kahit hindi po umabot ang poste ng 3 meters,,,hangang 2.70m. lang kasi,kc malalim foundation..pero ang Lapping nman ay 1.20

  • @josephmiranda4201
    @josephmiranda4201 ปีที่แล้ว

    Hi sir, pwd magsuggest ng topc ng construction joint po sir. Thankyou

  • @johncane8684
    @johncane8684 ปีที่แล้ว

    Sketch up ba gamit mo dito lods?

  • @sandyapolinario4233
    @sandyapolinario4233 2 ปีที่แล้ว

    Pano po naging 4.020 m at 4.520 yung sa end support na clear distance??

  • @mohammadmustapha299
    @mohammadmustapha299 2 ปีที่แล้ว

    kapag sa top bars kung L/3 pag top bars kailangan ung splicing mo Hinde papasok sa L/3 pag sa bottom bar nman kung L/4 na dapat splicing mo papasok sa L/4 ganun lang un

  • @jpmcreations470
    @jpmcreations470 2 ปีที่แล้ว

    Price list po ng mga materials meron po ba kayo?

  • @entertainmentvibes3165
    @entertainmentvibes3165 2 ปีที่แล้ว +2

    Bakit nag splice sa bottom bar malapit sa support? Di naman yun extra bar?

    • @maberikinstink9407
      @maberikinstink9407 ปีที่แล้ว

      lapping inside L/4 but after 2D from the face of the Column, if lapping is extended into the tension zone use lapping length for tension bars

  • @samuelmatias7170
    @samuelmatias7170 2 ปีที่แล้ว +1

    Sir saan ba dapat ang dugtungan ng rebars sa slab...hndi b pwedeng mag splice sa mismong beam..thanks

    • @pinoycivilengineerkonstruc3515
      @pinoycivilengineerkonstruc3515  2 ปีที่แล้ว

      Hello sir, Ang mga bakal natin sa slab ay Katulad din po ng bakal sa mga beams natin kung Saan May required lapping zone kung Saan dun tayo dapat mag dugtong ng mga bakal,
      May ginawa akong video ng lapping zone sa slab po, check po ninyo ung link
      th-cam.com/video/-z42qsQBG0Q/w-d-xo.html
      Ung mga lapping zone at lapping length ay makikita natin sa mga structural plans, if ever na Wala kayo makita na details dun, pwede kayo mag request sa structural ng details

  • @roycallangan7804
    @roycallangan7804 2 ปีที่แล้ว

    sir,sorry po masyadong maliliit yung letra o numero po ba iyon di q mabasa .thank

  • @artvee0074
    @artvee0074 5 หลายเดือนก่อน

    Pwede mag pagawa ng cutting list?

  • @reynaldcrisostomo791
    @reynaldcrisostomo791 2 ปีที่แล้ว

    Pwede po pasend sa email ung structural notes po sir?

  • @maryjanealvero8442
    @maryjanealvero8442 ปีที่แล้ว

    Good day sir. Sir may na encounter po ako yung extra bottom bars po ng girder is hindi po sa midspan nasa both left and right po katulad po ng Top bars. May ganon po ba talaga?

    • @TheAaronvila
      @TheAaronvila ปีที่แล้ว +1

      Yes possible po yun pag masyado maraming bakal ang required sa top bars ng support, may provision kasi sa code na dapat yung dami ng reinforcement sa bottom bars is least 1/2 ng reinforcement ng top bars.

    • @maryjanealvero8442
      @maryjanealvero8442 ปีที่แล้ว

      @@TheAaronvila thankyou so much po sir.

  • @romelynbonghanoy900
    @romelynbonghanoy900 6 หลายเดือนก่อน

    Kalabad pero laban

  • @marvinvillahermosa9235
    @marvinvillahermosa9235 ปีที่แล้ว

    Babbag tabbo aparo astray

  • @hyacinthvlog8380
    @hyacinthvlog8380 2 ปีที่แล้ว

    Malinaw po ikaw mag turo salamat po,,,

  • @maberikinstink9407
    @maberikinstink9407 ปีที่แล้ว

    Bawal po mag splice sa support dahil nasa zone 4 po tayo except Palawan area, when we design a structure we shall treat it as an SMRF

  • @eduardomarquez489
    @eduardomarquez489 2 ปีที่แล้ว +3

    di ako naniniwala sa mga engr ng dpwh tungkol sa plano at construction notes. galing din yan sa private na kinopya lang nila para sa building permit. di sila may gawa nyan. mas bilib pa rin ako sa mga engr sa private engineering company

  • @mohammadmustapha299
    @mohammadmustapha299 2 ปีที่แล้ว

    Ang gulo Ng pag bar cutt mo

  • @Roger-jp5ro
    @Roger-jp5ro 3 หลายเดือนก่อน

    magulo at nakakalito sa splicing ng bottom bars sa beam ,may mga engineers na nagvlog (tatlo yata engineers na pinanood ko ang vlog nila) na pwedeng magsplice within the column.at eto nanaman vlog nag iisplice within 2d na sa sabi ng ibang engineer na no splice at this point. ano ba talaga mga engineers .contradicting each other