POURING AND LAPPING OF COLUMN: SAAN PWEDENG MAGPUTOL NG BUHOS AT MAGDUGTONG NG REBARS SA POSTE?

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ก.ย. 2024
  • MGA DAPAT TANDAAN SA PAGBUHOS NG CEMENTO AT DUGTUNGAN NG BAKAL SA POSTE. MGA KAILANGANG MALAMAN SA PAGGAWA NG POSTE.
    This video is NOT sponsored. Some product links are affiliate links which means if you buy something we'll receive a small commission.
    BUILDMATE: invol.co/cl5y7rd
    Buildmate Online Depot
    Welcome ka dito Ka-BUILDMATE! 👋
    🚧Your One Stop Hardware Shop is always here
    with the most complete home & living needs.
    Be updated with our Special offers because every day
    is Guaranteed LOWEST PRICE with us 🎉
    ✨DAILY VOUCHERS GIVEAWAY with just one click
    in our ✅FEED Section & Chat button.
    plus our Special 🚛 FREE SHIPPING deals
    What are you waiting for?
    Follow us and Get a Voucher now!
    Home improvement design (Art Design PH): invol.co/cl5lx7p
    Online Shopping Platform (LAZADA PH):invol.co/cl5lx98
    Shop Online Specialized in hard to find items (Galleon PH): invol.co/cl5lxab
    The Ultimate online shopping Experience (Ubuy PH): invol.co/cl5lxdb

ความคิดเห็น • 279

  • @oslekcom1
    @oslekcom1 3 ปีที่แล้ว +6

    Kung ang column ay subjected to seismic dapat sa gitna ang lap splice mo to develop plastic hinging at mid ht . Kung Meron kang shear wall ibang case naman yon

  • @jualyal2622
    @jualyal2622 3 หลายเดือนก่อน

    Engineer linalagyan pa ba ng epoxy cold joint ng column or diresto buhos na lang din ng semento?

  • @chesteryodong8718
    @chesteryodong8718 2 ปีที่แล้ว +1

    Splacing ng 16 mm poste grade 40 salamat po idol

  • @danilodanting6052
    @danilodanting6052 3 ปีที่แล้ว +1

    ayos very informative as a structural engineers, as a kasador wala ka bang mga patakaran sa arrangements ng mga stirrup joints between slabs or slab and gilid ng structure. Kritical sa arrangement ng SLABS, edge slabs sa gilid ng mga stairs, most commonly errors as very experienced KASADOR, may shortcut drawing ka how to figure out base sa structural engrs.etc diy and kasador

  • @LandoAlvarez-i9t
    @LandoAlvarez-i9t 5 หลายเดือนก่อน

    Salamat po enjeneer dagdag kaalaman po sa akin bilang construction worker

  • @davesantos9473
    @davesantos9473 2 ปีที่แล้ว

    Salamat boss wala ako ke idea idea now lng ako natuto mabuhay kayo

  • @cezexploresvlogs
    @cezexploresvlogs 3 ปีที่แล้ว +1

    Thank u, timing ito need ko ito ngayon.

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      sundan nio lang po ung plano para di po kayo maligaw.

  • @mahirapipilit4452
    @mahirapipilit4452 3 ปีที่แล้ว +1

    clear height po ng column ang pinag-uusapan diyan. 3.2m - depth of beam pa ito.

  • @romanhonorio5222
    @romanhonorio5222 2 ปีที่แล้ว

    Engr. Ano ba ang purposed ng eccentric footing? Maraming salamat po sir.

  • @ezraconztruct1182
    @ezraconztruct1182 3 ปีที่แล้ว +1

    thanks sa information sir, irequest ko po sana madiscuss nyu dugtungan tulad ng beam kung saan walang nakaprotrude na rebar, anu ang mga suggestions at pwede gawin. thanks in advance

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      sure po, isama q po sa list ng gagawin qng video, salamat po sa pagtangkilik. have a nice day

  • @marjorycurambao9641
    @marjorycurambao9641 ปีที่แล้ว

    Halimbawa mataas ung tambak, hindi aabot sa 2nd floor ganun din po ba? Salamat

  • @august1070
    @august1070 3 ปีที่แล้ว +2

    Hello sir! Thank you for sharing us your knowledge. Sir please pasagot po. Paano kung hindi nasunod yung tamang hinto ng buhos. Sa mismong papatungan ng beam na kasi hininto yung buhos doon sa bahay na pinapagawa ko. Ano po kaya pwede gawin doon? Please answer sir. Thank you and God bless!

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      Need po mawala ung cold joint, pag magbubuhos po pakalinisin ung termination joint saka mag grout cement. Thanks for watching

  • @maurineagustin8572
    @maurineagustin8572 3 ปีที่แล้ว +1

    Sir, ano po ang dapat gawin pag nkalimutan mglagay ng abang sa ppste. Kailangan ksi para sa pipe chase. Thanks!

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      need po na i site visit and be careful po sa chipping of structural parts

  • @leoalmario4204
    @leoalmario4204 ปีที่แล้ว

    Kung ang kontrata ay labor lumpsum, sinu ang gagastus sa pagpapatayo ng temporary barracks

    • @GabsRomano
      @GabsRomano  ปีที่แล้ว

      Kasama sa contract ang temporary facilities

  • @butchfloreylasin7253
    @butchfloreylasin7253 2 ปีที่แล้ว

    Sir ppaano gumawa ng loft house ang size po 3x5

  • @watchme7192
    @watchme7192 3 ปีที่แล้ว +1

    Magandang araw Sir Gab ang development length po ba sir ay kahit sa saang direction like pag ang rebar ay nasa lower portion ng FTB ang bend ng dev length at pataas or pwede rin pababa ang direction ng bend. Salamat po

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว +1

      Ung rebar sa ibabaw pababa cya, ung rebar sa ilalim pataas. From compression is upward, from tension is downward sa support.

  • @joannenderez6885
    @joannenderez6885 2 ปีที่แล้ว

    new subcriber po sir gabs,thanks po sa pagtuturo

    • @joannenderez6885
      @joannenderez6885 2 ปีที่แล้ว

      salamat po uli sir,"GOD"bless po sayo and to your family

  • @juliusgabayan7671
    @juliusgabayan7671 ปีที่แล้ว

    Hello sir di po bs yung splicing zone sa poste ay nasa midle third?

  • @litosocorro5573
    @litosocorro5573 ปีที่แล้ว

    ser magandang araw itanong kung makakasama ba sa biga yung may krak nagahibla ng buhok hindi puba ito maka epekto sa stractural napang 3floor .salamat

    • @GabsRomano
      @GabsRomano  ปีที่แล้ว

      Need po ng actual inspection especially kung sa structural ang concern.

  • @mdccastro1643
    @mdccastro1643 2 ปีที่แล้ว

    good pm ser makakabili po ba ng steel deck khit kunti lng po. at san po owd makabili thank u po

  • @jaybesantiago4556
    @jaybesantiago4556 2 ปีที่แล้ว

    sir gabs magandang gabi po..tanong ko lang po kung if nabuhusan na yung slab tapos abang lang muna po yung bakal sa mga poste gano po ba ang minimum na haba na bakal na kailangan iabang pag tapos magbuhos ng slab..6 pcs na 12mm po ang bawat poste

  • @raypgtv4590
    @raypgtv4590 4 หลายเดือนก่อน

    Okey po,pero parang dko nakita ang sagot kung bakit po ganyan.
    Okey jn ang dapat ang putol peru bakit kailangan putulin jan.
    Okey para daw matibay peru paanu naging matibay eh may putol na po.
    Yan po mga d ko pa nagegetz boss😊😊

  • @armandosalise
    @armandosalise 3 ปีที่แล้ว

    Sir good day... Saan ba pueding magputol ng buhos sa footing tiebeam at slab?

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว +1

      commonly sa normal construction poste poste po, thanks for watching

  • @franciabalais2066
    @franciabalais2066 2 ปีที่แล้ว

    Sir Gabs.paano po kung extension ng bahay ang eeslab.tapos yong mga beam n dudugtungan n finish n sya.ang plano sna ewwelding nlang pwedi po b yon.or masensil at eweelding.

    • @GabsRomano
      @GabsRomano  2 ปีที่แล้ว

      Mas ok kung masinsil ng dahan dahan at sakto lang na maikawit ang idudugtong kahit di na naka welding. Thanks for watching

  • @maximofabella1175
    @maximofabella1175 ปีที่แล้ว

    Mgkano po b tamang kontrata Ng 48sqm. floor area , 2 storey , 4 bedrooms . Sna po mtulungan nu ako salamat po. Maximo Ng taytay rizal

  • @arviegalvez8172
    @arviegalvez8172 3 ปีที่แล้ว +2

    Great topic sir!!! Thank you!

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      ur welcome po and thanks

  • @carminadagatay1307
    @carminadagatay1307 2 ปีที่แล้ว

    Hi sir. Good morning.. any suggestion po kapag nag chipping sa column para malagyan ng footing tie beam. Ano po kayang pwede gawin if ever na nabuhusan na yung column at footing tie beam

    • @GabsRomano
      @GabsRomano  2 ปีที่แล้ว

      Need po ng actual visit ng professional para makita conditions, wag po basta mag chipping baka mag crack lalo na kung malaki concrete cover.

  • @madyangue5067
    @madyangue5067 3 ปีที่แล้ว

    Thanks po may messages ako sa inyo sa fb

  • @pongoni7586
    @pongoni7586 2 ปีที่แล้ว +1

    pwede po ba ung buhos ng column hanggang sa ilalim ng beam???

  • @tonyooynot9582
    @tonyooynot9582 ปีที่แล้ว

    sir paano kung 6m ang haba ng bakal ko nabili tapos ang lalim ng footing ko ay almost 2.6m- kasi po may fill na 1.10 above sa natural grade line. basi sa Gen Note.. No Foundation shall rest on Fill. so need kong hanapin un natural grade as reference ko sa lalim na hukay ko na 1.5M for 2 storey. lumalabas na xacto lang ang 6m na bakal sa floor finish ng second floor. ang tanong ko pwedi ba akong magsplice sa ground floor within splice zoone

  • @jonathancayasa7091
    @jonathancayasa7091 3 ปีที่แล้ว

    Thanks for sharing your knowledge sir, more videos po..

  • @obetmixtv1858
    @obetmixtv1858 2 ปีที่แล้ว

    Boss tanong lng po s ratio ng palitada... 1 is to 3 three nh.. Isa sako semento (25 kgs) by tatlo timba which is lagyan ng pintura (16kgs).. Tama po b ako sir....

    • @GabsRomano
      @GabsRomano  2 ปีที่แล้ว

      Ung isang sako ng cemento katumbas ng dalawang timba ng pintura. May video po aq tungkol sa ratio.

  • @the_explorer5356
    @the_explorer5356 2 ปีที่แล้ว

    Sir ask kolang po pwdi pobang gawing iton nasa video balak kopo kasi mag pagawa ng 2nd floor short pa kso sa budget pwdi koba lagyan ng abang na bakal, option-2 gayahan ang nasa video, option-3 over size ko ang beam halimbawa 15x11 buhusan ko ng buo ang 15x11 pro mag aadd ako ng bakal na nakaabang same ng nasa video, option-4 buhusan ng buo ang beam at ipatatong nalang ang slab...ano po ma ipapayo ninyo sir tnx

    • @the_explorer5356
      @the_explorer5356 2 ปีที่แล้ว

      th-cam.com/video/pbtjTA_VIWk/w-d-xo.html

  • @sirnellyt2557
    @sirnellyt2557 3 ปีที่แล้ว

    Hello po sana mapansin ung buhos po kasi namin ginawa nung mason ko ay naputol kumbaga putol ung buhos nila nasa kalahati matibay pa po ba un pag dinugtungan ng panibagong buhos 3rd floor pa naman

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      may mga nakikita po aqng gumagawa ng ganyan especially pag tinitipid ung formworks , kailangan po free from dirt saka di ma stop ng matagal ung kasunod na pouring of concrete, pero bottom line mas ok parin po pag monolithic.

    • @anabelizamanga5800
      @anabelizamanga5800 3 ปีที่แล้ว

      Same problem... m buhos on column is naputol s kalahati ng poste... any suggestion po pra mas maging matibay ang poste slamat po ng marami

  • @almalynrivera9613
    @almalynrivera9613 7 หลายเดือนก่อน

    Sir gab? oki lang po ba na di puno ang buhos ng viga? kasi di pa nman kami cgurado kung kailan kmi mgapapa.second floor

  • @jaynorhnuruddin1651
    @jaynorhnuruddin1651 3 ปีที่แล้ว +5

    Sir, puwede po bang gawa kayo ng topic about sa 6meters ang layo ng poste. ano pong sukat ng column at beam at foundation depth para po sa apat o limang palapag na residential/apartment building.
    Salamat po in advance

  • @imeldagaluna508
    @imeldagaluna508 6 หลายเดือนก่อน

    Good Afternoon po Sir Gab, tanong ko lang po kung pwede ako sa inyo mag pagawa ng Plano ng bahay ,, 2nd flr. semi commercial ung baba, residential n po ung 2nd flr. may sukat n 120 square meter
    maraming Salamat po.

    • @GabsRomano
      @GabsRomano  6 หลายเดือนก่อน

      You can reach me through my messenger gabs romano.

  • @7badman
    @7badman 2 หลายเดือนก่อน

    Sir, paano po ba malaman ang height ng column? From flooring to tuktok ng beam po ba, o yung clear space po between flooring at beam?thank you po

    • @GabsRomano
      @GabsRomano  2 หลายเดือนก่อน

      Usually may mga height na naka indicate na Finnish floor to floor Meron ding top of beam. Kinoconsider din ang ceiling height kc may gusto high ceiling at iba mababa kc tilid daw sa electric consumption pag nag Aircon, ung iba kinoconsider ang mga ilalagay sa ceiling tulad ng piping atbp.

  • @cynthiacaneta7013
    @cynthiacaneta7013 2 หลายเดือนก่อน

    Kung ang size ng nakal sa poste sa baba ay 16mm, sa 2nd floor po ba kailangan ireduce sa 12mm? O ano pk dapat ng bakal na dapat gamiton? Salamat po sa magiging sagot nyo.

    • @GabsRomano
      @GabsRomano  2 หลายเดือนก่อน

      Ung designer po magsasabi kung pwede pero safer kung 16mm parin

  • @the_explorer5356
    @the_explorer5356 2 ปีที่แล้ว

    Ito ang video idol th-cam.com/video/pbtjTA_VIWk/w-d-xo.html

  • @AlbertoPascua-m9p
    @AlbertoPascua-m9p ปีที่แล้ว

    Sir yong bend mo sa vertical bar sa footing hindi naisama yata dapat 3.2 + 1.5 + .30 = 5.0 m pls, correct me if I 'm wrong.

    • @GabsRomano
      @GabsRomano  ปีที่แล้ว

      You are right, thank you po

  • @diosdadoomamalin2822
    @diosdadoomamalin2822 3 ปีที่แล้ว +2

    Sir pwed malaman kung anong exact measurement ng foundation ng bahay kung ito ay two story house pero itatayo sa isang slope area .

  • @ismaelgabriel1829
    @ismaelgabriel1829 8 หลายเดือนก่อน

    idol normal ba na mag vibrate Ang slab

  • @aerso2128
    @aerso2128 3 ปีที่แล้ว +2

    Hello po sir sana mapansin po ninyo. Nais ko po sana mag padagdag ng palapag sa bahay namin. 22sqm lng po sya. Tanong q po. Ung bakal po ng poste ay putol sa 3rd floor nakalitaw lang sa sahig ay 1inch pwede parin po b ito madugtungan? Para poste pa 4rth floor anu po ang gagawin? Weldingan po b sya? Salamat po

  • @gwynxo4209
    @gwynxo4209 ปีที่แล้ว

    Sir Gabs ask ko lng po, bakit kadalasan makita ko sa const. site after mag buhos ng slab level yong column sa slab. Base sa sabi mo dapat lampas sa L/4 ang paghinto sa buhos sa column?

    • @GabsRomano
      @GabsRomano  ปีที่แล้ว

      Para po maiwasan ang cold joint at the beam termination kc mataas ang shear stress sa joint

  • @loreto4505
    @loreto4505 ปีที่แล้ว

    Sir ask lng po,nag pagawa po aq nang bahay bali po dalawang.palapag pero roof deck po yong pinakabubong tas ang lalim po nang column 1mtr lng po,ang tnong kpo kakayanin po ba nang posti ksi puro buhos at isa pa po matubig po yong area o location po nang pinatayuan ko ang gamit ko po pla n bakal sa column is 12mm at 10mm yon lng sana maipaliwag nio po salmat

    • @GabsRomano
      @GabsRomano  ปีที่แล้ว

      Maganda po ipa as built nio or analyse structurally para cgurado

  • @thomasbenafin9530
    @thomasbenafin9530 2 ปีที่แล้ว +1

    Sir gab puid bang bang sa ilalim ng biga mismo ang putol ng buhos?maraming salamat po

  • @ericboysinelgache7892
    @ericboysinelgache7892 3 ปีที่แล้ว +1

    Ask ko lang po
    Pakisuyo.gawa kayo ng video na
    4floor
    Size ng poste biga .tie beam at footing.at size po ng bakal.thanks po sa response

  • @miniiemouse7590
    @miniiemouse7590 3 ปีที่แล้ว +1

    hi sir.. pwd po ba kayo gomawa ng video ilan po standard sukat po ng stirrup and hoop pra po sa beam at poste.. mapa 1st floor po or 2nd floor. at ano standard mga bakal dapat po gamiten pra po dito.. salamat po advance

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      ok po pero meanwhile please watch my other videos, baka makatulong po. thanks for watching

  • @ramisesumali1119
    @ramisesumali1119 3 ปีที่แล้ว +3

    thanks bro. npaka galing mo teacher.

  • @sharynjavero9666
    @sharynjavero9666 2 ปีที่แล้ว +1

    Ask po footing to footing tie beam ok lang ba na putol Ang pag buhos Ng cemento

  • @ernestoacerojr.1653
    @ernestoacerojr.1653 3 ปีที่แล้ว +1

    Sir ask ko lng.professor PO b kau?kci mlinaw PO pliwanag nyo

  • @armandosalise
    @armandosalise 3 ปีที่แล้ว +2

    Sir good day... Ang epoxy grouting in beam and column connection okay ba sa footing ang dugtungan para sa mag second floor

  • @kimokeno145
    @kimokeno145 3 ปีที่แล้ว +3

    Sir, request po ng stairs naman sa sunod. Salamat po.

  • @MDF4072
    @MDF4072 3 ปีที่แล้ว +1

    pwede nyo din po ba idiscuss ang difference ng precast house (camella ,lumina, or bria) vs traditional CHB,beam and post made house.

  • @markchristianconcepcion4922
    @markchristianconcepcion4922 2 ปีที่แล้ว +1

    Sir, question saan po bah, nag uumpisa ang sukat na Lenght/4 nang column..
    Nasa total height po ba ng column or nasa ilalim ng slab? Nasa 800mm kasi yung slab sir. Thanks in advance

    • @GabsRomano
      @GabsRomano  2 ปีที่แล้ว

      unsupported length or clear distance of column. Thanks for watching

  • @cezexploresvlogs
    @cezexploresvlogs 4 หลายเดือนก่อน

    Dami p namng bara bara bye kung trumabaho

    • @GabsRomano
      @GabsRomano  4 หลายเดือนก่อน

      True po, may mangagawa kc na sasabihin na kaya nya pero malakas lang pala loob pero sira ang diskarte.

  • @dongarybacuno6315
    @dongarybacuno6315 3 ปีที่แล้ว +1

    Sir good day po. Maaari po ba na I-beam ang gamitin para sa 2nd floor kahit ang dudugtungang poste sa 1st floor ay RCC column? Ang nangyari po kasi ay 1st floor muna ang ginawa then itutuloy na lang ang paggawa ng 2nd floor some other time.

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      pwede po ma I-beam basta maayus po ung termination, mag aanchor bolt and base plate po sir

  • @hrdojhrjskd4558
    @hrdojhrjskd4558 ปีที่แล้ว

    buhos lang ng buhos hangang 2nd floor paano po ung tie beam?

    • @GabsRomano
      @GabsRomano  ปีที่แล้ว

      Lagyan ng abang ung tie beam. Thanks for watching po.

  • @romys4660
    @romys4660 3 ปีที่แล้ว +4

    Thanks for the information Sir. watching from KSA🇸🇦🇵🇭

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      So nice of you sir, salamat sa pagtangkilik.

  • @dualrayder2294
    @dualrayder2294 3 ปีที่แล้ว +1

    Sir tanong ko lang po pagkatapos mag buhos ng beam at slab sa first floor alam ko po sa vlog niyo yong curing process kaya lng kailan po pwede magsimula magtrabaho sa mga column para ituloy yong structural ng second floor kahit hindi po tatanggalin yong mga support ng pg buhos. Salamat

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      hello po, 7 days pwede na as long as wag muna babawasan ang shoring. thanks for watching

  • @juneryanderama6580
    @juneryanderama6580 ปีที่แล้ว

    Paano po kung walang splacing saan po tayo magsstop ng buhos?

    • @GabsRomano
      @GabsRomano  ปีที่แล้ว

      malapit po sa ilalim ng biga , say 70cm

  • @rinacasuga6060
    @rinacasuga6060 ปีที่แล้ว +1

    Sir anu ibig sabin ng RB beam

  • @CriseldaAlfonso3
    @CriseldaAlfonso3 5 หลายเดือนก่อน

    Ano po bang magandang laki ng poste sa two story with roof deck, ilan pong sixteen mm ang pwedeng ilagay dun? Ano po bang laki ng parilya ,ano po ang pwedeng gawing sterap ng poste,,okay lng po na ba 8pcs na sixteen para sa 30 by 30 pero ang fisinish niya pong buhos is 35 by 35.

  • @jaymoratalla7920
    @jaymoratalla7920 2 ปีที่แล้ว

    Sir ok lng ba putol yung buhos sa slab?bale 6x6 yung bhay..6x3 lng yung binuhusan..yun lng kasi kaya ng budget..may mga abang nmn na bakal..ok lng ba magdugtong ng bakal sa gitna ng slab at beam

  • @rodantemorales5909
    @rodantemorales5909 หลายเดือนก่อน

    nice explanation and very clear. thank you for your video.

    • @GabsRomano
      @GabsRomano  หลายเดือนก่อน

      salamat po

  • @gapwoG
    @gapwoG 3 ปีที่แล้ว +1

    tanong ko po sir, papapaano naman yung patungkol sa biga or beam, saan po pwedeng magputol at magdugtong ng buhos ng tie beam or croos beam?

  • @budzayala
    @budzayala 2 ปีที่แล้ว +1

    Sir salamat sa video nyo marami ako natutunan, ask ko lang din paano nman ang dugtungan sa slab kung kailangan din mag putol ng buhos?

  • @ferdinandjr.cabeso4921
    @ferdinandjr.cabeso4921 3 ปีที่แล้ว +1

    Sir Gab, pwede maputol sa FTB, then next lift ay yung shaded part mo?

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      mas ok po kung sa tamang dugtungan . Thanks for watching

  • @niloyu105
    @niloyu105 2 ปีที่แล้ว

    Keep watching and support especially 80sec. Ads from Al Khafji Saudi Arabia.
    Sir baka puwede po maka hingi sukat para sa bakod na may gate na 3meter ang lapad. Matibay din poba ang 30x20cm mas matibay poba kapag square ⬛ column? Plano kolang po hatiin ang 600cm. Bali 200cm lang Mula flooring ang taas... Padamay narin si Yung sukat po ng stirrups? On napoba Yung 80cm pang paa?

  • @wilmardumpor966
    @wilmardumpor966 3 ปีที่แล้ว +1

    Pwede po bang magkaroon ng dugtongan ang column rebar before sa slab?

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      pwede po as long as ifollow lang ung lapping requirement and detail.

  • @castelobanlaygas1930
    @castelobanlaygas1930 3 ปีที่แล้ว +1

    Sir sana sir madiscuss nio din po ung construction joint...
    Include nio na rin yung adeantage and disadantage ng partial beam at monolithic pouring sa steel decking..

    • @castelobanlaygas1930
      @castelobanlaygas1930 3 ปีที่แล้ว

      Sir, wala pa po gaanong topic pertaining sa construction joint.. Ung tipong hindi nabuhusan ung buong slab. Saan pwede tumigil sa pagbuhos ng slab ay tie beam?

  • @davidlazaro8481
    @davidlazaro8481 ปีที่แล้ว +1

    Masalimuut ang paliwanag,sna yum madaling intindihin

  • @Ballog-a-LAKAY
    @Ballog-a-LAKAY 2 ปีที่แล้ว +1

    Hello Sir, thank you for sharing knowledge. Much better appreciated, Kung uulitin mo Yung Content na ito incorporating the realistic construction, ie: location of splice Kasama ang depth of Girders

  • @becool2765
    @becool2765 3 ปีที่แล้ว +1

    Sir pwede ba unti untiin ang pagawa ng bahay poste muna pag may budget naman saka umpisahan uli.

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      Yes po marami pong nagpapagawa unti unti, sa umpisa po need ung pundasyon hanggang sa maiangat sa ground ung poste at chb, make sure po na malinis at maayos parin ung terminations pag itutuloy nio na. thanks for watching

  • @johnlerrypillos6832
    @johnlerrypillos6832 3 ปีที่แล้ว +2

    Salamat sir gabs. Dininig mo ang tanung ko. Continuenlang po sa pag share ng iyong kaalaman.

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      Salamat din sir sa pagtangkilik. have a nice day

  • @gurkharei5683
    @gurkharei5683 2 ปีที่แล้ว +1

    Maraming salamat po sainyong mga tutorial malaking tulong sa aming mga magpapagawa ng bahay. Mabuhay po kayo at godbless..

  • @benjiemarabesia122
    @benjiemarabesia122 3 หลายเดือนก่อน

  • @noelbriones5179
    @noelbriones5179 2 ปีที่แล้ว +1

    ano po gagawin Sir Gabs sa existing column sa ground floor na balak i.extend pa2nd floor to roof deck? Same lang po kasi ang pagputol sa ibabaw. Ano po yung diskarte nun?

  • @nardopespes9209
    @nardopespes9209 3 ปีที่แล้ว +1

    Thank you po sa pagbahagi Ng inyong kaalaman Sir new subscriber here😀😀

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      Salamat din po sa panonood

  • @temujinakim9606
    @temujinakim9606 3 ปีที่แล้ว +1

    Sir sana naipaliwanag niyo ho ang tungkol sa pagdugtong ng mga bakal sa poste na dapat di lahat ng bakal ay nasa isang location lang ang dugtungan dapat 50% lng ang bakal na nka spliced at 50% ay deretso.Kaya ang bakal dapat di lahat ay same length para di mapa isang location lang ang splicing.

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      absolutely po at least alternate

  • @bernardpasion6235
    @bernardpasion6235 3 ปีที่แล้ว +2

    Sir gawa ka nman video 3-storey residential house about sizes ng columns beams & footings.. sizes of deformed bars etc. thanks in advance po

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว +1

      will include po sa list sir

    • @ronaldpunzalan1580
      @ronaldpunzalan1580 3 ปีที่แล้ว

      Nèed ko ren sir.
      Thanks..
      God Bless..!

  • @edwardventura7648
    @edwardventura7648 7 หลายเดือนก่อน

    Gudpm ho. Saan ho ba ang reference ng L/4? Sa ibaba po ba ng biga o sa ilalim ng biga? Salamat po

  • @benedictosering8728
    @benedictosering8728 2 ปีที่แล้ว

    hillo po 2nd flr slab na ang bahay ko mag add ako ng 3rd sampo na ang poste nya kailangan ba may additional ilan ang aditionalna poste.. ang sukat ng pondasyon 1mx1m w ang 1.5ft hight 12mm ang cabelya

  • @noliauxilio1
    @noliauxilio1 3 ปีที่แล้ว +1

    sir more power po, thank you sa information n sinishare nyo. request po sana ako ng 2storey with roof deck if pwede po.

    • @GabsRomano
      @GabsRomano  3 ปีที่แล้ว

      soon po, thanks po sa supporta

  • @zaldybandojoserrano4615
    @zaldybandojoserrano4615 3 ปีที่แล้ว

    Engr ok lng po b n ang lapping legnth ay sosobra p dun s hinihingi n 40d o 50d kc kalimitan nman n napraktice ng mga skill worker ay 0.80 o kaya ay 1.00 ang kalimitang ginagawa n lapping legnht n sobra n s hinihinge ok lng po b un

  • @bityhayd1430
    @bityhayd1430 2 ปีที่แล้ว

    pwede po ba mag bawas ng size ng bakal sa 2nd floor? ang ginamit sa ground ay 8-16mm. ano po pwedeng gamitin na sukat sa 2nd floor (roof deck)

  • @pamelagracegallego568
    @pamelagracegallego568 3 ปีที่แล้ว +1

    sir, pg sa mga FTB at roof deck beam, saan puede mag putol ng buhos?

  • @markanthonymadamba
    @markanthonymadamba 4 หลายเดือนก่อน

    paano nmn po kapag may tambak muna ang lupa? gaano ang preparation ng reinforcement?

  • @mr.bantozay1783
    @mr.bantozay1783 3 ปีที่แล้ว +1

    More videos sir dami kung natutunan

  • @joenifercalunsag3500
    @joenifercalunsag3500 ปีที่แล้ว

    Gaano ka lalim ang poste at gaano kalagi ang puting sa area na may 25 square meter in 3 story

  • @rolandosantos4187
    @rolandosantos4187 ปีที่แล้ว

    Nakaka tuwa engineer na natutulungan mo ang mga viewers na maintindihan ang mga dapat sundan sa pag construction. May tanong ako ginagawa ba dito sa pinas ang flat beam? Pwede ba mabigyan mo rin kami ng idea kung paano ang detalye, thank you...

  • @angillomartin28
    @angillomartin28 2 ปีที่แล้ว

    Saan po nakuha yung 1.3

    • @GabsRomano
      @GabsRomano  2 ปีที่แล้ว

      Range beam ratio of base and depth

  • @stevevillanuevaable
    @stevevillanuevaable 3 ปีที่แล้ว +1

    very informative, ano po ang background or qualification nyo? new subscriber

  • @Heartsforbini
    @Heartsforbini 2 ปีที่แล้ว

    Ok langba sir sa may biga o tiebeam pinutol yung buhos ganun kasi nakita ko pag gawa 'g bahay ko

  • @markdominicmampusti1022
    @markdominicmampusti1022 2 ปีที่แล้ว

    Hi sir Gabs may nakita po ako na yung splicing eh dapat staggered ano po knaibahan nito kpg pantay pantay ang pagsplice ng vertical bars?

  • @g.gaming7367
    @g.gaming7367 ปีที่แล้ว

    sir pwde mag tanong .. mahalaga sana tong i tatanong ko sana makasagot kapo

  • @pamelagracegallego568
    @pamelagracegallego568 3 ปีที่แล้ว +2

    tnx a lot, sir! very informative..

  • @LTE2019
    @LTE2019 3 ปีที่แล้ว

    Isang tagasubaybay po kmi sa vlogs mo idol, sa ginagawa po naming bahay, dito po ako kumukuha ng info

  • @merlitomixvlogs9979
    @merlitomixvlogs9979 2 ปีที่แล้ว

    Ang linaw Ng pagkakapaliwanag sir,isa rin po akong manggagawa Ng bahay dagdag kaalaman po ito saakin, maraming salamat po ingat palagi godbless