K Type Thermocouple Repair

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ม.ค. 2025

ความคิดเห็น • 11

  • @ziggymondus8753
    @ziggymondus8753 5 ปีที่แล้ว +2

    This is a very good demonstration of logic and reasoning, as well as educational in itself. Great!

    • @marlondavid1106
      @marlondavid1106 3 ปีที่แล้ว

      I dont mean to be so offtopic but does anybody know a method to get back into an instagram account??
      I was stupid lost the account password. I love any tips you can offer me

    • @irajonah3108
      @irajonah3108 3 ปีที่แล้ว

      @Marlon David Instablaster ;)

    • @marlondavid1106
      @marlondavid1106 3 ปีที่แล้ว

      @Ira Jonah thanks for your reply. I got to the site thru google and im waiting for the hacking stuff now.
      Seems to take quite some time so I will get back to you later with my results.

    • @marlondavid1106
      @marlondavid1106 3 ปีที่แล้ว

      @Ira Jonah It worked and I now got access to my account again. I'm so happy!
      Thank you so much, you saved my account!

    • @irajonah3108
      @irajonah3108 3 ปีที่แล้ว

      @Marlon David no problem :)

  • @ziggymondus8753
    @ziggymondus8753 5 ปีที่แล้ว +2

    I just tested a solution for getting heatshrink on those back wires, if it ever comes up again.
    I took the smallest fitting shrink, cut it to size then cut a slit all the way through so it was a ‘wrap-around’ instead of a complete tube.
    Then I put a second heatshrink, two sizes up, that fitted over the wrap-around. Heating both tubes gave the grip I would not have achieved with either on their own.
    You only need to insulate one wire in this case, so it might be worth a try another time?

  • @fixitfelix718
    @fixitfelix718 3 ปีที่แล้ว

    What type of k type do you recommend for setting of less and 0 f and 650f ..i test freezers and ovens..use a firld piece meter with k type connection..is there a specific one..i attempted to repair mine but it also melted and kinked in the middle ..it was a mess

  • @browaruspierogus2182
    @browaruspierogus2182 6 ปีที่แล้ว

    I have to try PT termocouples. They are a bit more expensive but heard that are better.
    I want to measure lower temperatures like below -50C and don't know what exactly would be good for that