I Built the Pumper Truck!!!!! Master Chief is Alive!!!

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 เม.ย. 2021
  • Go to buyraycon.com/offtheranch for 15% off your order. Brought to you by Raycon
    Thanks so much for all the love and support guys!!! Grab a shirt/hoodie/patch and join the Demolitia today!!! www.bunkerbranding.com/pages/...
    I get lots of comments asking about my equipment, here is what I use to make my videos!
    Main Camera amzn.to/3cTN8qf
    Secondary Camera amzn.to/30qx5vb
    Drones amzn.to/2Sf0oMF amzn.to/3kWYXyG
    Music:
    • ♪ MDK - Super Ultra [F...
  • บันเทิง

ความคิดเห็น • 6K

  • @JamieR1234
    @JamieR1234 3 ปีที่แล้ว +2264

    Hey Matt, Firefighter here as well. Couple of notes. Stop by your local firehouse and see what they have to say. They will help you for sure.
    1) Most important, make sure you get a tank with baffles or keep that thing 100% full or you will end up flipping offroad.
    2) You can get away with a way smaller hose as well. Most wildland hose is 1" in diameter soft hose. Most structural hose is 1 3/4". For reference I did the math, for a 95 gpm nozzle you'd need to be pumping roughly 130-150 psi at the pump into the hose.
    3) definitely plumb yourself a manifold off of the pump. You want numerous valves with numerous options. Anytime the pump is running you want a tank return line to recirculate water so the pump doesn't overheat or wear. you can hear how unhappy it is when you close the nozzle. This will also allow you to have another valve to have your nozzle that you wanted at the pump as well as another valve for a hose reel.
    4) Hose reel is definitely the way to go for convenience but having regular hose has its benefits as well. Research how to fold it any you will be set. Tons of ways to store and deploy it easily.
    5) Throw the pistol grip off of the nozzle. You want to get that thing out in front of you so you can swing it around. Having the pistol grip makes your tendency to keep it close in to your body which makes it harder.
    6) we don't use cam lock in the fire service but I don't have any experience on it. I would switch to hard plumbing for everything between the tank and the pump though and keep the hard suction to refill from a pond or pool.

    • @maxlynn269
      @maxlynn269 3 ปีที่แล้ว +57

      Oh man I really wish more people would like this so he sees it

    • @PlainStraightShooter
      @PlainStraightShooter 3 ปีที่แล้ว +26

      I agree and I am not a fire fighter, but I have messed with plenty of spray rigs and used a lot of trash pumps. No offense Matt, but we call those trash pumps. I agree above but you could just T in your outlet and valve the 1.5 fire hose and keep spooled. use the other as the 1 inch like talked about above. Cam locks will work okay with your set up and leave you a out for water out of a pond, just use a big suction with screen so you don't get a lot of mud or trash. Your going to hate that tank not baffled and yes black would be a lot better.

    • @noahsnarleynvideos5826
      @noahsnarleynvideos5826 3 ปีที่แล้ว +31

      I can speak to the cam locks. I work for a utilities construction company so we use pumps and hoses a lot for wellpoints, and other types of drainage. We have cam locks on all of our hoses and don’t have problems with it. Just make sure there’s a gasket in the female end when you hook them up and that there isn’t a bunch of mud on the mating surface because that might inhibit the cams from locking.

    • @d.a.s.s4614
      @d.a.s.s4614 3 ปีที่แล้ว +33

      Another firefighter here. Definitely good advice here. Would also agree that trashline/ brush line on a reel in 1" is probably best way to go with multiple port options. Not 100% sure but thought that was a cloth jacket hose. Make sure you dry those out after getting them wet.

    • @cdnroofer
      @cdnroofer 3 ปีที่แล้ว +21

      This is the best advice and explanation out of everyone’s two cents in the comments. I’m not saying other people are wrong or right, but you took the time to point out and explain why. Love it. Thanks for your comment, and teaching me a few things. Cheers from Oshawa Ontario Canada

  • @kevindevine3395
    @kevindevine3395 3 ปีที่แล้ว +6171

    Matt I've been a firefighter for over 35 years, what you need is a 1" hose reel commonly known as a booster line or a trash line that will solve all your problems it's a hard line so it won't kink it's on a reel so you can just roll it up and pull out what you need

    • @Gmpro02
      @Gmpro02 3 ปีที่แล้ว +109

      this needs more upvotes and replies so it makes it farther up the list of comments and gets seen

    • @RIZZ0B
      @RIZZ0B 3 ปีที่แล้ว +16

      Great advice

    • @clayrog6405
      @clayrog6405 3 ปีที่แล้ว +89

      You need a water cannon mounted up top. The 1" reel will work well for your use also.

    • @bubbapearson751
      @bubbapearson751 3 ปีที่แล้ว +29

      Booster line is the way to go !!!

    • @tomlordtom
      @tomlordtom 3 ปีที่แล้ว +13

      Dang good advice.

  • @PhilipKloppers
    @PhilipKloppers 3 ปีที่แล้ว +14

    Hey Matt, from chatting with our local sugar cane farmers, I've picked up a few things over the years that may be useful:
    1) Having the tank as close to the center of the wheels is better.
    2) It might be a good idea to mount the tank across the bed rather than inline, and as far toward the cab as possible, and with the outlet toward the driver side. That way you can put an elbow and valve right up front as you get out to get the water on as fast as possible without having to run around to the other side or climb up on the bed to open the valve.
    3) If you install the electric start on it, put the starter switch on the drivers side as well, for the same reason. If you keep the pull start, some motors let you unbolt the pulley cover and rotate it, so you might be able to pull start it from the ground if you can orient it to be reachable from the side of the bed.
    4) With the outlet on the side, you can also tee off and put a faucet on the side. It's just a surprisingly useful addition to be able to get some water without having to start everything up. Small fires that are just starting might only need a bucket of water to extinguish.
    5) With larger water tanks you definitely want to have baffles in the tank to prevent the mass of water moving around from moving the truck around. I'd imagine that's even more important with the tank sitting so high up.
    6) With gas pumps it's a good idea to put a recirculation valve in to feed water back into the tank when the nozzle is closed. The flow of water through the pump serves as a coolant, and having the pump running without water moving can cause problems. (Electric pumps have pressure regulators that switch the pump off when there is no flow)

  • @BarneySaysHi
    @BarneySaysHi 3 ปีที่แล้ว +34

    That pump definitely needs a return line to the tank for when it's idling, it does NOT sound happy!

    • @Saluki388
      @Saluki388 3 ปีที่แล้ว

      Exactly. It will be burned up in no time.

  • @hellandhighwater777
    @hellandhighwater777 3 ปีที่แล้ว +950

    Hey Mat, I'm a metal fabricator at a firetruck dealership in Florida and I have built some brush trucks. You should really plumb in a recirculation valve so that when your pump is running and you're not flowing water it will go back into your tank, that will keep you pump from overheating.

    • @isaackrabill8621
      @isaackrabill8621 3 ปีที่แล้ว +5

      I was just going to say the same thing, I have a unit for my pickup with a reel and pump. You can use a bypass line back into the tank with a valve on it to regulate the bypass pressure.

    • @brennancrumb835
      @brennancrumb835 3 ปีที่แล้ว

      Pierce?

    • @madhatte73
      @madhatte73 3 ปีที่แล้ว +1

      came here to say this, recirc line is also useful for pressure control

    • @markg1495
      @markg1495 3 ปีที่แล้ว

      Wouldn’t happen to be the factory near Ocala would it?!

    • @1BigNateTV
      @1BigNateTV 3 ปีที่แล้ว +4

      Mount it under the side of the bed of the truck so it's at chest height when your using it

  • @haydenboyd928
    @haydenboyd928 3 ปีที่แล้ว +1014

    Fire Chief in SE Arizona. I’m cleaning out our firehouse storage. I know I’ve got that booster reel and hose I can GIVE you. I also have some couplings and appliances to help with your build! You’re off to a good start.

    • @staticgameslevi
      @staticgameslevi 3 ปีที่แล้ว +29

      This needs to get higer up the list people willing to give stuff cuz they are fans are the best 💪

    • @Derek-5515
      @Derek-5515 3 ปีที่แล้ว +8

      Very kind gesture

    • @mariogoose7702
      @mariogoose7702 3 ปีที่แล้ว +6

      Awesome

    • @paulmoritz2240
      @paulmoritz2240 3 ปีที่แล้ว +5

      Email him for sure!

    • @Kriklifeforever
      @Kriklifeforever 3 ปีที่แล้ว +10

      I'd be very disappointed if matt ignored this comment

  • @Civvyphil
    @Civvyphil 3 ปีที่แล้ว +1

    Hey Matt. I’m a firefighter in Clovis NM. Huge fan of the channel. Lots of good comments on here.
    Keep the red hose. Just fold it how your local FD does. We use a (triple lay). Makes deployment 3x faster.
    Get a gated wye for the pump. That would allow a nozzle to be mounted on the bed of the truck for really fast fire attack. A mounted smooth bore nozzle would work well.
    Baffles for the tank would make driving it more safe. Filter for hard suction of lake is a good idea.
    Remember that having your own truck doesn’t mean you don’t need a Fire Departments help. Call them first. Then start your attack.
    Super cool build!!

  • @Jam_MG
    @Jam_MG 3 ปีที่แล้ว +206

    im just waiting for the news headline "texas man starts wild fire testing his new fire truck

    • @criticaldamage8997
      @criticaldamage8997 3 ปีที่แล้ว +2

      😂

    • @anthonyjack6536
      @anthonyjack6536 3 ปีที่แล้ว +1

      Lol

    • @greggillham9604
      @greggillham9604 3 ปีที่แล้ว +7

      But as you read the article or as they report it on TV. Man who started wild fire single handedly puts it out after fire grows to 500 acres

    • @riley5340
      @riley5340 3 ปีที่แล้ว +1

      Lol

    • @0divide136
      @0divide136 3 ปีที่แล้ว +1

      oh no

  • @89ludeawakening1
    @89ludeawakening1 3 ปีที่แล้ว +829

    Hey Matt, your truck's cab is in transport lock. You need to pull the pins to get the cab's air ride working.

    • @isaiahwade1484
      @isaiahwade1484 3 ปีที่แล้ว +31

      Yep I hope he sees this comment.

    • @89ludeawakening1
      @89ludeawakening1 3 ปีที่แล้ว +16

      @@JohnZ0805 maybe he'll see my comment. I'm sure he has no idea about it being locked.

    • @89ludeawakening1
      @89ludeawakening1 3 ปีที่แล้ว +25

      @MMVPN Sports anytime I see someone with an MTV or LMTV, I look to see if the lock pins are in. A lot of people that get them and they don't know much about them, they don't even realize the cab has air ride and don't know to check the transport lock pins. I hope he sees it too because I know that truck is bouncing him all over the cab. Haha

    • @adamsbackcountryliving
      @adamsbackcountryliving 3 ปีที่แล้ว +4

      he needs it to fit in the barn thats way its in transport mode

    • @89ludeawakening1
      @89ludeawakening1 3 ปีที่แล้ว +11

      @@adamsbackcountryliving I highly doubt that. Has he said that?

  • @larryparish5984
    @larryparish5984 3 ปีที่แล้ว +602

    MATT, "CAUTION", if that tank doesn't have baffles in it, you might not want to use it as a permanent option. With the water sloshing around in there, it could tip your truck over in rough terrain. Have a tank built from heavy aluminum diamond plate with baffles. And a lower profile that is spread out more over the bed of the truck. That set up you have will be very top heavy & dangerous on rough roads. And center the tank over the rear axle.

    • @joeyrocha8070
      @joeyrocha8070 3 ปีที่แล้ว +5

      Good point

    • @Pman353
      @Pman353 3 ปีที่แล้ว +4

      Big brain

    • @lukelubbers1867
      @lukelubbers1867 3 ปีที่แล้ว +6

      Wss looking for this tbh

    • @jones5311
      @jones5311 3 ปีที่แล้ว +8

      Best thing he can do is keep if full.

    • @kaiden47
      @kaiden47 3 ปีที่แล้ว +8

      You can purchase baffle balls to place in the tank to stop this.

  • @quintingraeff1660
    @quintingraeff1660 3 ปีที่แล้ว +1

    USAF Aircraft firefighter here. You have a good system going so far. Most rural brush trucks have a remote nozzle on the bumper to fix your hose issue. Your pump and tank will last you longer than you think but make sure and carry an extra fuel can with you. We use s stewie on one of the volunteer depts out here and the truck is a beast.

  • @calebdixon221
    @calebdixon221 3 ปีที่แล้ว +1

    From a firefighter - buy a floating strainer and a separate piece of hard suction hose to use for pulling water from a water source to fill your tank. Also can get a floating gas powered pump that could fill the tank while flowing water

  • @arizonametamorph6623
    @arizonametamorph6623 3 ปีที่แล้ว +1395

    You're going to find out very quickly that you need a tank with baffles in it. All of that water sloshing in the tank is going to make the ride...thrilling.

    • @cpsencik04
      @cpsencik04 3 ปีที่แล้ว +29

      I thought the exact same thing when I saw it

    • @thelosthorizons1
      @thelosthorizons1 3 ปีที่แล้ว +84

      If not baffles it needs to remain completely full at all times...

    • @lawrencebeeler6273
      @lawrencebeeler6273 3 ปีที่แล้ว +24

      Yes I was thinking the exact same thing he starts running around the property with water and it's going to be sloshing around and he's going to have a hard time stopping

    • @mattj630
      @mattj630 3 ปีที่แล้ว +37

      Yeah, if it’s half full, a ton of water going sideways will not be fun on a sideslope. Can get some perforated drain pipe, the black stuff on big rolls, and just stick a bunch in the tank. Will baffle it “ok” without taking up a ton of capacity.

    • @joncat8519
      @joncat8519 3 ปีที่แล้ว +1

      yeah an bigger

  • @tat-2-71
    @tat-2-71 3 ปีที่แล้ว +375

    Someone else already mentioned it but, yeah, you're gonna need to paint the tank or something. Sunlight shining into that clear tank is gonna cause algae to grow which can stop up your nozzles.

    • @brendanleach8971
      @brendanleach8971 3 ปีที่แล้ว +2

      Ok this is kind of weird but I used to pump algae at an algae lab while in college. It depends on the algae (which ones? Idk it was the highest paying job on campus and I didn't ask questions) some algae types can be thick and others aren't. I used pumps like this all the time to transfer the algae. I never had an issue in the year I worked there.

    • @braskybill25
      @braskybill25 3 ปีที่แล้ว

      @@brendanleach8971 no doubt that the pump can handle some algae. Did you use a nozzle on the other end or just a hose by itself? I'm not saying you are wrong or right. Just curious

    • @grumpyoldman6767
      @grumpyoldman6767 3 ปีที่แล้ว

      Bleach ftw

    • @barrymccockinner842
      @barrymccockinner842 3 ปีที่แล้ว +1

      I clean swampy algae filled pools, pumps can handle algae no problem, I use harbor freight pumps to drain pools.

    • @bluecookiemonster3
      @bluecookiemonster3 3 ปีที่แล้ว +2

      Nozzle could likely clog he said, not pump

  • @michaelcervas6922
    @michaelcervas6922 3 ปีที่แล้ว +7

    Matt for the water suction from outside water source highly recommend that you get a filter to keep leaves and debris from your pump.

  • @BrewdasDM7419
    @BrewdasDM7419 3 ปีที่แล้ว +16

    You have a very good Son there. He didn't even think about going after you with that hose. 🤘😎

    • @ryanlightwood9074
      @ryanlightwood9074 3 ปีที่แล้ว +1

      You know he probably thinking it or just spraying water straight up lol

  • @mosquitoswat1
    @mosquitoswat1 3 ปีที่แล้ว +283

    ATTENTION!! PULL START FROM THE GROUND...take off the screws around the starter rope coil, rotate the starter cage to be the right angle to start while standing on the ground, and put the screws back in...BAMMO! (Tip from Steve’s small engine repair, TH-cam)

    • @walkermediaworx
      @walkermediaworx 3 ปีที่แล้ว +12

      Those Honda motors have easy to install electric start kits.

    • @jefficusgunman5885
      @jefficusgunman5885 3 ปีที่แล้ว +6

      shoot, i was gonna say invest in a key start

    • @benthebuilder6934
      @benthebuilder6934 3 ปีที่แล้ว +2

      I also also was going to say get a electric starter😂

    • @philb5593
      @philb5593 3 ปีที่แล้ว +1

      Good tip.

    • @Nickerian91
      @Nickerian91 3 ปีที่แล้ว

      Just buy the electrical started or if you are looking for a cheap solution remove the cover and start it with a screwdriver.

  • @washingtontoler
    @washingtontoler 3 ปีที่แล้ว +234

    I am a volunteer firefighter and I really think that you are going to end up wanting a tank with baffles so that it doesn't slosh around so much and instead of the larger 2.5" hose, we only use 1.5" hose on a booster reel that makes it easy to put up and flows plenty of water for your common brush fires.

    • @Jeffrey-Flys
      @Jeffrey-Flys 3 ปีที่แล้ว +22

      Ah.... but there’s your miscalculation.Y’all fight “common brush fires.” This truck is built for Demo-ranch brush fires!!!!! 😂

    • @John_Conner222
      @John_Conner222 3 ปีที่แล้ว +4

      yep. People don't think about that. With a large tank sloshing around it can actually move the truck in unexpected ways when brake hard or turn hard.

    • @megacookie9199
      @megacookie9199 3 ปีที่แล้ว

      Good man

    • @michaelwesten
      @michaelwesten 3 ปีที่แล้ว +2

      There is no need for baffles if the water tank is 100% full, and it's not like he is in a rush to get ready to put out the next fire, when driving back with half a tank, and also just make sure there is a breather on top, so you don't implode the tank.
      Also make sure you truck is standing in a dry place, equipment that's standing dry is a lot more reliable, something like Romney huts are pretty affordable.
      I would also mount the fire/water pump under the bed of the truck for easy operation, and maybe have one on both sides of the truck, having a backup is never a bad thing.

  • @wingspeshlish3187
    @wingspeshlish3187 3 ปีที่แล้ว +7

    My father that passed away 3 years ago worked for Stewart’s and Stevenson for 30 years it’s good to see one of the trucks he help build

  • @Kevin_the_minion8
    @Kevin_the_minion8 3 ปีที่แล้ว +2

    So a lot of brush trucks have a brush hose that is slightly smaller than your 2 1/2 inch hose. That should give you a little more pressure. The brush hose is also rigid and goes of a hose reel that mounts on the back of the truck.

  • @bryanb3778
    @bryanb3778 3 ปีที่แล้ว +354

    Without baffles in the tank, be cautious, baffles help to reduce the effect of weight sloshing in turns etc, which in turn can cause a roll over

    • @frankensteinracing3520
      @frankensteinracing3520 3 ปีที่แล้ว +10

      @WebCity Films baffle balls are the greatest things in unbaffled tanks some good sound advice

    • @DanSheldon48
      @DanSheldon48 3 ปีที่แล้ว +2

      Good call on the baffles sloshing water has a ton of force

    • @georgejulien3286
      @georgejulien3286 3 ปีที่แล้ว +6

      A full tank is really not an issue... a half tank on the other hand... 😂😂😂

    • @mybackhurts7020
      @mybackhurts7020 3 ปีที่แล้ว +3

      I knew a guy that had one of those square water tanks and he had to slam on the brakes and it crashed his F350 cab

  • @wilbur2255
    @wilbur2255 3 ปีที่แล้ว +212

    You need a different tank get one that is black so algae doesn't grow in your tank and make sure it has baffles so the water doesn't slosh around.

    • @loganabrahamson2317
      @loganabrahamson2317 3 ปีที่แล้ว +7

      Hopefully he sees this. This is a huge thing, unless you plan on keeping the tank empty.

    • @jimlayton2510
      @jimlayton2510 3 ปีที่แล้ว +4

      Have one like that at work algae is always a problem.Have to keep bleach in it or have it empty all the time.

    • @laurentbeaulieu2446
      @laurentbeaulieu2446 3 ปีที่แล้ว

      a quick fix can be bleach but not too much

    • @TheRockFarm
      @TheRockFarm 3 ปีที่แล้ว +7

      Fill it with wiffle balls to baffle it.

    • @braydenbretzel
      @braydenbretzel 3 ปีที่แล้ว

      @@TheRockFarm agreed

  • @Knapplihme
    @Knapplihme 3 ปีที่แล้ว

    Hi from a Danish firefighter
    Even though we use other couplings here (storz coupling) you aren’t wrong to have at least one soft hose, they are way easier to carry a long distance, and extend if needed.
    Hard hose in Denmark is called HT (høj tryk- High Pressure) because they need a pressure of 20 bar (not sure what that is in psi), but it’s substantially higher than what your pump can deliver.
    We use the HT at 80% of the fires, and they are excellent an rollable, although our type need special rolls, because the hose needs to be quite sturdy to take the pressure. Ours are 70 meters long (210 feet long approx.) these are with snap coupling and those are then need for our nozzles and the pump
    My advice, new pump, and if you decide going for hard hose, you will need some special roller for it to be worth it... we use Dräger as our supplier but I have seen alternations from Rosenbauer, and CSR which all are the biggest suppliers in the EU, they have compatibility checkers and so on, for easy introduction and buying experience
    It’s nice to see what you have! And it’s plenty for just on the ranch, but ease of use and nice to haves HT is nice to have, and a bigger pump is a must 😊🚒🚒🧯
    Keep going being you
    Many greetings from Denmark

  • @jeffmonson2073
    @jeffmonson2073 3 ปีที่แล้ว +3

    GIANT SLIP N’ SLIDE! Get a 100’ long sheet of visqueen and a few sand bags to weigh it down. Then find a nice grassy hill at a park and use the fire truck for a giant slip n’ slide. It is seriously so much fun!

  • @mikestrong661
    @mikestrong661 3 ปีที่แล้ว +640

    Take it down to the local fire house and talk to them about all the questions. I’m sure they’ll have lots of answers from experience.

    • @ABrit-bt6ce
      @ABrit-bt6ce 3 ปีที่แล้ว +27

      They'll be very forthcoming, It's in their interest for you to be safe.

    • @johndavis1721
      @johndavis1721 3 ปีที่แล้ว +12

      You spitten facts

    • @georgereiss998
      @georgereiss998 3 ปีที่แล้ว +20

      And they will be able to give you some training so you are less likely to die trying to put out a fire.

    • @ahmed53938
      @ahmed53938 3 ปีที่แล้ว +2

      nah

    • @Scott_C
      @Scott_C 3 ปีที่แล้ว +10

      They also might help him source a water cannon for the cab turret mount.

  • @meadowviewlawncarellc8079
    @meadowviewlawncarellc8079 3 ปีที่แล้ว +407

    You should do a bypass line on the discharge side of the pump back into the tank, so when the hose nozzle is off and the pump engine is still running you’re aren’t dead heading the pump causing damage.

    • @silnieuwland5686
      @silnieuwland5686 3 ปีที่แล้ว +8

      Exactly what I was planning to comment

    • @covert767
      @covert767 3 ปีที่แล้ว +9

      And it can double as the fill line when he's using the pump to fill the tank.

    • @AwesomeGames56
      @AwesomeGames56 3 ปีที่แล้ว

      Would it be pressure activated?

    • @overthehill1958
      @overthehill1958 3 ปีที่แล้ว +7

      Yes pressure relief like a power washer. He will burn up the pump.

    • @josiah74
      @josiah74 3 ปีที่แล้ว +4

      @@AwesomeGames56 Yeah. You could attach something like the bleeder valves that you see on hydraulic systems. When the pressure gets high enough, the valve gets opened and releases the extra fluid into wherever.

  • @Inferno12M
    @Inferno12M 3 ปีที่แล้ว +7

    I would recommend a booster line, usually comes in 100' reels.. it would be 1" and if you get a good one it'll have a electric roll up feature!

  • @beforetoday88
    @beforetoday88 3 ปีที่แล้ว

    I'm a volunteer firefighter for a small town in lower Alabama. We mostly deal with brush fires. That hose is meant to be an attack line. I wouldn't put a hose reel on it, however, I'd build a box a little lower than the bed to fold the hose in the box. I would also suggest putting a manifold in with a second hose coupling for a smaller line with a hose reel.

  • @StageRightvideo
    @StageRightvideo 3 ปีที่แล้ว +354

    Points to consider:
    * learning hose handling is part of the job.
    * Fitting a discharge manifold will let you easily fit different size hoses and choose which one to use via quarter turn valves.
    * While rushing to put out any fire - Remember to call out the fire service too. You won't have enough water, hoses or ability to tackle a huge fire and will need the professional support.
    *You'll have fuel, engine, pump, etc fitted to that truck - so carry a pair of proper fire extinguishers too.
    * If the truck is on stand-by it Must have water ready too. There will be no time to top off its water tank when a fire is spotted.
    * Secure all loose equipment against movement with some quick release fittings and keep everything in regular places so you never have to search for anything.
    * Train as a fire fighter.

    • @SheepdogSmokey
      @SheepdogSmokey 3 ปีที่แล้ว +8

      THIS!

    • @dashingriggs
      @dashingriggs 3 ปีที่แล้ว +14

      I think training for a fire fighter is a huge thing. its not just a small thing to do.

    • @dustinmeier9753
      @dustinmeier9753 3 ปีที่แล้ว +13

      And because you'll need the tank filled and ready, install a sight glass and paint your tank black to cut down on algae growth.

    • @braydenbretzel
      @braydenbretzel 3 ปีที่แล้ว +6

      100% agree couldn't say it better!!! Use fuel stabilizer in the pump too.... gloves, pants, shirts, ect in case it gets a little out of control.... rakes/ shovels..... bleech the rank so algae doesn't form..... tons of stuff to consider.

    • @Jamescritzer13
      @Jamescritzer13 3 ปีที่แล้ว +5

      Manifold is a must if you want different size hoses in my opinion then you’re not in a bind trying to switch out hoses in an emergency. You can leave all hoses hooked up as well

  • @Rusty.1776
    @Rusty.1776 3 ปีที่แล้ว +417

    Just bring the whole rig by a fire house near you and let them give you advice on placement and product to use.

    • @TheComputerCowboy
      @TheComputerCowboy 3 ปีที่แล้ว +30

      This. Absolutely. Especially because they’d be thrilled to know he’s prepared to handle crap on his property without him burning down the whole countryside in the area. Less work for them to offer good advice than to be handling brush fires.

    • @angryhoneybadger4189
      @angryhoneybadger4189 3 ปีที่แล้ว +7

      I'm sure someone that works there would know who he is too at least. I mean you would think so anyways lol

    • @inflatablewolfie
      @inflatablewolfie 3 ปีที่แล้ว +10

      @@angryhoneybadger4189 Considering that many of them had to be there at some of his christmas tree bonfires, yeah, I would assume many of them know him!

    • @joerock11bob45
      @joerock11bob45 3 ปีที่แล้ว +4

      he should take it to a volunteer fire department they would love to help build a fire truck

    • @atk9989
      @atk9989 3 ปีที่แล้ว +3

      Yea kinda confusing that he is asking the internet and not the local fire department that he knows.

  • @Happy.HC_
    @Happy.HC_ 3 ปีที่แล้ว

    Trained Mechanik here 👋
    You should get a flater tank to bring down your point of weight, and maybe you could move the pump like on the side under the Truck, and get a like an hydrant to switch between pumping, sucking, and maybe the short hose.
    Greetings from Germany 🙃

  • @michaelrossi5971
    @michaelrossi5971 3 ปีที่แล้ว

    I’m a firefighter in California. What you need off your pump is a gated-Y if you want a long attack house and a hard line for the back of the truck. I’d recommend keeping the regular synthetic fire hose as your attack line, if you get a hard line it’s going to be a pain in the butt. But that’s my 2 cents

  • @peterwyckoff
    @peterwyckoff 3 ปีที่แล้ว +384

    If you are wanting to have the option to pump from a dirty water source like a lake or river you should also have a large filter to put on the hose or else you will pick up junk(fish,mud,plants) into your pump.

    • @wipplewopple1876
      @wipplewopple1876 3 ปีที่แล้ว +6

      Junk, and possibly small creatures or fish.

    • @ionstorm66
      @ionstorm66 3 ปีที่แล้ว +6

      You only need a strainer keep big stuff out.

    • @lemonaid8678
      @lemonaid8678 3 ปีที่แล้ว +3

      They make them screen cage things
      That goes on the end.
      Small particles won’t damage one of them pump.

    • @raybship1
      @raybship1 3 ปีที่แล้ว +6

      Absolutely! Good call and maybe a float so the hose stays close to the surface

    • @Notarobot310
      @Notarobot310 3 ปีที่แล้ว +4

      As well as a secondary hard line, otherwise how does the water go back in if you're already using it on the other side of the pump?

  • @johngutierrez-zamora5528
    @johngutierrez-zamora5528 3 ปีที่แล้ว

    Just a resident Firefighter with not much experience, but I have a few suggestions.
    1. A baffled tank will help a lot with water weight shifting on turns.
    2. You might not need a bigger pump but 2.5" can flow at 250 or even more gallons per minute with the right nozzle
    3. Our brush trucks of a similar size carry 750 gallons, which is a lot.
    4. we use Gallonage pumps on our brush trucks as opposed to pressure pumps, I'm not sure what you have
    5. Our brush trucks don't use 2.5" lines because we don't typically need to flow that much water for this setting, and we want the water we have to last longer
    6. if you use a hose reel you need a rigid hose because the water won't flow through a flat hose
    LAST AND MOST IMPORTANT!!!! EVEN IF YOU HAVE A PISTOL GRIP DON'T USE IT, JUST HOLD THE HOSE LIKE A MAN (you'll have more control of your stream too)

  • @cristophermorrison7574
    @cristophermorrison7574 3 ปีที่แล้ว

    For your hose, get a 1 1/4" booster line. You can get a line a real off of an old firetruck. For splitting we use what's called a gated Y. Keep in mind with a fully loaded tank offroad, you will snap those straps in no time. Way too much weight. Also get some spanner wrenches for your fittings. And if you really want to get more fire aligned Get some Storz connectors to put everything together. If you want to keep the connector running off of the tank, drill a hole in the handle and put a push/pull rod in it that you can access from the side of the truck. Hope this helps.

  • @camneal7012
    @camneal7012 3 ปีที่แล้ว +159

    You need to get a filter so when you get water out lakes and stuff you don’t have to worry about fish and sticks getting in your tank

    • @edgraves7098
      @edgraves7098 3 ปีที่แล้ว +3

      Working at a Marina we used similar pumps to pump out boats that were sinking. Yes you definitely need some kind of filter/strainer to keep stuff out of the pump. Also we used the cam lock fittings on all our pumps. Saltwater can cause problems with them if they aren't maintained however I doubt that would be a problem for you.

    • @chad0856
      @chad0856 3 ปีที่แล้ว

      yep they make strainer baskets to hook on with a cam lock. Keeps the trash out

  • @justindavies9742
    @justindavies9742 3 ปีที่แล้ว +48

    Think about 4500lbs of water moving one direction in a turn, that tank is designed to sit in one spot in a shed or next to a house, you gotta combat the momentum with baffles.

  • @THEREALBRYCEH
    @THEREALBRYCEH 3 ปีที่แล้ว

    Matt, make sure that with the tank being white it will allow sunlight (UV) into the tank and will cause algae/bacteria growth in there. That water will get nasty very quickly. Make sure to drain it pretty regularly. We usually recommend black water tanks when outdoors to keep the sunlight out. 😋

  • @PLATINUMSWORDS
    @PLATINUMSWORDS 3 ปีที่แล้ว

    Not a firefighter but I do booster treatments and am familiar with this setup.
    1. Get a booster line
    2. Get a Booster reel that comes with a valve.
    Before turning off the pump, close the valve to the reel. It'll keep the line primed and you don't have to pull the entire hose out to use it.

  • @tompeavy8254
    @tompeavy8254 3 ปีที่แล้ว +167

    Southwest Fire Dept member here. Glad to see you enjoying our former truck. Come by and see us any time you’re in the Auburn AL area.

    • @blakewestwood8096
      @blakewestwood8096 3 ปีที่แล้ว +3

      Roll Tide!

    • @corporal1139
      @corporal1139 3 ปีที่แล้ว +7

      Matt, you should have got a tanks with internal baffles to keep the water from sloshing around and potentially rolling the truck in a turn. The pump is known as a trash pump. If your mostly worried about brush fires you should have got forestry hose which is much smaller than your 2 1/2 inch hose and way lighter or a booster reel like an earlier commenter said. Bottom line be very careful driving the truck when the tank has water in it.

    • @jacobschmit2399
      @jacobschmit2399 3 ปีที่แล้ว +1

      War eagle!

    • @motolifealways
      @motolifealways 3 ปีที่แล้ว +1

      Also what will make the tank safer, would be a tank with Dividers like tanker trailers and trucks have, as that will eliminate alot of forward and backwards momentum of the water stored.

    • @BoomerKeith1
      @BoomerKeith1 3 ปีที่แล้ว

      Gotta be cool that you're a viewer and get to see how the old truck ends up. Also, thank you for the work you do!

  • @TheHunt-dq4vm
    @TheHunt-dq4vm 3 ปีที่แล้ว +184

    For your truck I recommend 1inch hose, that's what we use for brush fires.

    • @garrettbedford1795
      @garrettbedford1795 3 ปีที่แล้ว +8

      We fight with 1 inch hose we only carry 750 gallon so u have to preserve it as much as possible

    • @Tech21101
      @Tech21101 3 ปีที่แล้ว +8

      @@garrettbedford1795 A forestry head is great for preserving water, the one Matt has there will eat through water like nothing.

    • @franksquicciarini1156
      @franksquicciarini1156 3 ปีที่แล้ว +2

      Agree with this statement. Unless you have a steady water source, you want to preserve as much water as possible.

    • @Hammer-vr7or
      @Hammer-vr7or 3 ปีที่แล้ว

      Up here in New England my fire dpt. Uses 2 1/2 inch for brush and some forest fires

    • @jacobrussell3800
      @jacobrussell3800 3 ปีที่แล้ว +6

      Plenty of homes were saved from kitchen fires and dryer fires by a good ole booster reel! Miss the days of getting in and getting water on it fast. Aggressive interior attacks have been pushed out by hitting it hard from the yard babys...

  • @rampantsanity
    @rampantsanity 3 ปีที่แล้ว

    my suggestions (as someone who has run fire tankers):
    take your 100ft hose and cut ~10ft off and slap some cam locks on the raw ends. use the 10ft as the primary and the rest as the secondary.
    i would do the same with the rigid hose or get a smaller rigid hose so you can fill from some place. however, unless you have a water source, there's no point in planning for a water source you don't have. on that note, typically, the fill is plumbed in a way that doesn't allow you to release water back into the source. that is generally done by mounting a pipe that drops through the top of the tank with an air gap.
    skip the hose reel and go check out how the fire trucks do it. they sometimes do a kind of folded roll that deploys fast and keeps the fittings available from the outside.
    if you're going to do a "y", plumb in some boomless nozzles on 12v solenoids mounted on the truck. typically, a water tanker will have the 4 corners and the center in front covered so that they can knock down flames to get in and out of areas safely.
    finally... your tank should probably be metal... poly melts easier and that can also be a problem.

  • @willspencer6023
    @willspencer6023 3 ปีที่แล้ว

    You can also look into an electric start for the pump. Build a small box to keep your flat hose in. You can look up a firefighter flat lay for hose. If you plan on drafting or sucking water from a pond or water source to fill the tank I would look into a low level strainer for the cam-lock fitting and hose.

  • @BenCottman
    @BenCottman 3 ปีที่แล้ว +149

    You really should have gotten a tank with baffles to keep the water weight shift down.

    • @williamschratz7249
      @williamschratz7249 3 ปีที่แล้ว +5

      Was thinking the same thing

    • @Fannatic942
      @Fannatic942 3 ปีที่แล้ว +4

      This comment should be up!! Matt have to read this because weight shift of this much Of water si really bad

    • @BenCottman
      @BenCottman 3 ปีที่แล้ว +8

      @@Fannatic942 As a former apparatus driver, I have felt the effects of the water shift even with baffles and with none at all, it could flip a truck even the size of Matt's or break the mounting and roll off the truck destroying anything it falls on.

    • @timm2020
      @timm2020 3 ปีที่แล้ว +6

      Just throw some baffle balls in the tank.

    • @davidpeniston5351
      @davidpeniston5351 3 ปีที่แล้ว +3

      i'm *baffled* he didn't think of that hyuck hyuck hyuck...ok i'll see myself out

  • @enginebae3471
    @enginebae3471 3 ปีที่แล้ว

    I’m no firefighter but I use those pumps daily for water filtration. That gas tank will run about 2.5-3 hrs straight before needing fuel. And don’t worry about putting a bypass on it. It strains down under load but it’s a centrifugal pump that bypasses automatically after about 25psi head pressure. It does put a lot of load on the motor so I use synthetic oil and change it every 36 hrs of run time. On big jobs we run em 12 hrs straight every day and they hold up really well.

  • @elijahkimball221
    @elijahkimball221 3 ปีที่แล้ว +1

    As a small engine guy, you need to run non-ethanol gas with fuel treatment in it so it won't go bad and clog up your carburetor.

  • @mbarr691
    @mbarr691 3 ปีที่แล้ว +252

    Matt, maybe take a trip to your local Fire Department and see if they have any tips for your setup

    • @vaperainzero3886
      @vaperainzero3886 3 ปีที่แล้ว +4

      Thats a great idea

    • @Darckstarchild
      @Darckstarchild 3 ปีที่แล้ว

      My dad is firefigther in Perú he is now 70 years and serve 50 to the fire dep.
      I show this video and scream directly. WHAT THE HELL IS HE DOING 🤣
      In spanish " que mierda esta haciendo?"

    • @tyjones5019
      @tyjones5019 3 ปีที่แล้ว +1

      @@Darckstarchild Well dang it Samir, ask your dad what he recommends!!

  • @albaek790
    @albaek790 3 ปีที่แล้ว +83

    Those honda pumps can be fitted with an electric start, so you could have a Start button on the side and the pull cord as backup in the bed of the truck.

    • @Saladdressing67
      @Saladdressing67 3 ปีที่แล้ว +4

      Exactly what I was thinking. Electric start seems like it would make sense here

    • @oscarbrsting954
      @oscarbrsting954 3 ปีที่แล้ว

      Dansker?

    • @albaek790
      @albaek790 3 ปีที่แล้ว

      @@oscarbrsting954 Jep

    • @oscarbrsting954
      @oscarbrsting954 3 ปีที่แล้ว

      @@albaek790 Hæhæ fed nok🤟😎

  • @hardballerrecon4828
    @hardballerrecon4828 3 ปีที่แล้ว

    You should mount a hose bed so you can pull your attack line from either side. Attack line is the red hose. Also you will need to have a place to hang dry your hose after it’s been used. Stops it from rotting.
    Hose reel is handy but has higher price tag attached so you have to weigh our options. Good luck and let me know if I can answer any questions. 😀

  • @reginapickering2259
    @reginapickering2259 3 ปีที่แล้ว +1

    Hi mat here's a tip if you are filling up your tank fill it to the max or else the water will swish and push you around I know this because it has made our truck do a 360

  • @spiroInsano2
    @spiroInsano2 3 ปีที่แล้ว +1562

    How do i tell my woman that I watched a 21 minute long video of a man playing with a water hose and i enjoyed the whole thing.

    • @thomasstasinakis8351
      @thomasstasinakis8351 3 ปีที่แล้ว +23

      how do you explain to someone that a single video makes you this happy

    • @JNC7601
      @JNC7601 3 ปีที่แล้ว +61

      Pretty sure the Dont tell Mere rule applies here

    • @scottjackson1636
      @scottjackson1636 3 ปีที่แล้ว +20

      With enough scorn in your voice to make it clear she should have been watching with you.

    • @zavyz6364
      @zavyz6364 3 ปีที่แล้ว +7

      U don’t tell her

    • @DanielSvensson666
      @DanielSvensson666 3 ปีที่แล้ว +4

      Just make it sound less ambiguous so she doesn't think you watched an adult video of a guy. Just a tip.😂

  • @TheJordanRB
    @TheJordanRB 3 ปีที่แล้ว +481

    Can we all take a moment to appreciate Lincoln's masterful camera work. He's gotten so good.

    • @imtalented45
      @imtalented45 3 ปีที่แล้ว +7

      I was literally thinking the same

    • @mercetajs
      @mercetajs 3 ปีที่แล้ว +2

      @@imtalented45 same lol

    • @Grimjar
      @Grimjar 3 ปีที่แล้ว +1

      I didn't even notice that!

    • @jakieklassen5203
      @jakieklassen5203 3 ปีที่แล้ว

      @@imtalented45 hey

    • @jakieklassen5203
      @jakieklassen5203 3 ปีที่แล้ว

      @@imtalented45 hey

  • @dwitmoyer
    @dwitmoyer 3 ปีที่แล้ว

    Hey Matt to solve 2 of your problems get a 1-1/2 to 1-1/2 gated wye and you can put a 50' section of hose on the other half of the wye. And for rolling your hose look up a twin/double dounut roll. Sorry if someone already suggested this. I'm a day behind on my videos. Also I think we can officially welcome you to the firefighting brotherhood.

  • @connorshaul311
    @connorshaul311 3 ปีที่แล้ว

    Just letting you know as a firefighter who is somewhat familiar with type 4, 5, 6 engines for wildland I would recommend a wildland hose so 100ft 1 1/2 inch hose at the largest. Wildland is high pressure low volume. You shouldn’t need to go above 100 psi for the pump so it doesn’t need to be a large pump but if you keep the 2 1/2 I think it will struggle. I would recommend talking with your local fire department and they might even give you some old out of service fittings and things like that. They can at least set you on the right path cause I see a couple things I would recommend changing.

  • @jacsta3618
    @jacsta3618 3 ปีที่แล้ว +51

    Matt, because it's a white/clear plastic tank, if it's not getting emptied very often you should chuck some bleach in the water to stop it getting green and full of algae. Don't need much and it's still safe if you need it for drinking water (it's what we do over here in little old NZ).
    Ps, if you do actually see this, I LOVE your videos!! You're an awesome dude!

    • @scottjackson1636
      @scottjackson1636 3 ปีที่แล้ว +4

      also painting it black helps

    • @daleyoung7676
      @daleyoung7676 3 ปีที่แล้ว +2

      Sodium hypochlorite degrades very quickly in sunlight and is corrosive, would be best to paint the tank.

    • @the_retag
      @the_retag 3 ปีที่แล้ว +1

      Found a kiwi

  • @TheCritterWindow
    @TheCritterWindow 3 ปีที่แล้ว +85

    I think you need a water pressure recycle valve back to the tank. It will prevent cavitation in the pump when the hose is off and the pump is running.

  • @jamesk5131
    @jamesk5131 3 ปีที่แล้ว +1

    Hey Matt I worked in the the environmental field for a while and if you plan on sucking water from a lake or pond you will need a strainer to make sure your water is clean of debris

  • @almai4304
    @almai4304 3 ปีที่แล้ว +1

    Hi Matt, you can try to fit that pump on the side of the truck right under the truck's bed. It will give you an easy access to the pump and good chances to use the fuel tank that already there without adding extra fuel pump and hoses.

  • @bdrrobertson
    @bdrrobertson 3 ปีที่แล้ว +64

    If you plan on leaving water in the tank you should have got a black tank because the clear one will allow sun light to shine through causing algae and other things to grow which much plug up the pump or hose

    • @lilsolo68
      @lilsolo68 3 ปีที่แล้ว +1

      Will painting the tank work?

    • @brandonpanozzo86
      @brandonpanozzo86 3 ปีที่แล้ว

      @@lilsolo68 yes

    • @Rico_71
      @Rico_71 3 ปีที่แล้ว +2

      Does he need also some sort of baffles/compartments in the tank to avoid the water from sloshing too much while driving?

  • @dancarlsen87
    @dancarlsen87 3 ปีที่แล้ว +67

    Make sure your water tank is vented so you don’t collapse it in on itself.

  • @263rocker1
    @263rocker1 3 ปีที่แล้ว

    I work for a utility company and we have a couple of pumps exactly like this one. The pump will last for 5-6 hours on a tank of gas and will pump huge amounts of water. I wouldn't worry about pluming to the gas tank.

  • @heminator12
    @heminator12 3 ปีที่แล้ว

    I'd recommend for your application, use what we call a booster hose. Approx 1-1 1/2 inches in diameter. Would work probably best for what you want. Decent flow for smaller stuff, easier to handle as you can keep it on a power retract wheel, not NEARLY as heavy while charged, and not pushing back hard enough to need a 2 man crew. I've been a volunteer with a small town crew in new York since I was a senior in highschool, I'm not expert but I hope that helps!

  • @zachcapwell2811
    @zachcapwell2811 3 ปีที่แล้ว +68

    If you want to draft water out of a lake or body of water, I recommend having a strainer for the end of the hard suction line. Without that, particles and debris will get into your pump and you'll find that the pump wont work that well anymore.

    • @tigertank4567
      @tigertank4567 3 ปีที่แล้ว

      its a trash pump they have no problem with crap in the water

    • @johnmuricasmith8641
      @johnmuricasmith8641 3 ปีที่แล้ว +1

      He will get a quarter tank of mud and debris which will ruin not only the Fire fighting ability but damage the pump and the sprayer

  • @CaptGiggity
    @CaptGiggity 3 ปีที่แล้ว +153

    Come on over to Houston! We’ll let you flow some water from the real deal! Bring the kiddos too!

  • @LFINN-ui4zm
    @LFINN-ui4zm 3 ปีที่แล้ว

    Hey Matt, I am a Fire Cadet at station 77 and I suggest getting a booster reel for master chief. But keep the red 2.5” hose for bigger jobs.

  • @michaelroyal9375
    @michaelroyal9375 3 ปีที่แล้ว +1

    I use braided hoses with cam locks at work. One thing I will definitely recommend when using them with pumps that create pressure is a bleed off valve to relieve the pressure before unhooking the hose. Water can be as dangerous as any chemical.

  • @pghjpc
    @pghjpc 3 ปีที่แล้ว +65

    You should mount the pump under the bed in front of one of the wheels so you can access and start it from the ground. It doesn't need to be up on the bed with the water tank. And put connections to fill the water tank down there too so you don't have to climb up to fill it every time

    • @ryanmace100
      @ryanmace100 3 ปีที่แล้ว

      This is a great idea

    • @SirOtterman
      @SirOtterman 3 ปีที่แล้ว +3

      I was thinking the same thing. That & put an electric start on the pump so you can focus on mounting it in a way that's best for the lines instead worrying about clearance for pull start. Mounting it under the bed would also allow you to plumb hard lines under the bed so they are safe/out of the way (leaving the bed behind the tank clear/usable if needed)

    • @MikeStone1503
      @MikeStone1503 3 ปีที่แล้ว

      Agreed

    • @MikeStone1503
      @MikeStone1503 3 ปีที่แล้ว +1

      @@SirOtterman I think you both are on the right track 👍

  • @Thellbro
    @Thellbro 3 ปีที่แล้ว +458

    When you know how to handle a ”soft” hose you’ll appritiate it much more than a hard hose.
    ALSO, I think you should take a class in firefighting, why not take the entire Bunker Branding staff for a CPR-class and combine it? Just saying.
    Please like this so Matt and Mere se this comment.

    • @toxicplague6278
      @toxicplague6278 3 ปีที่แล้ว +5

      I definitely agree on the cpr and firefighting class it’s a really good idea

    • @Shortydude847
      @Shortydude847 3 ปีที่แล้ว +3

      Don’t fish for likes.

    • @paddington1670
      @paddington1670 3 ปีที่แล้ว +1

      @@Shortydude847 dont assume things.

    • @youtubu124
      @youtubu124 3 ปีที่แล้ว +2

      @@paddington1670 Its really not an assumption if the guy actually begs for likes.

    • @inokkinimy1268
      @inokkinimy1268 3 ปีที่แล้ว

      Haaaa.... nice 1👍👍👍

  • @UncleSamsTravelingRoadshow
    @UncleSamsTravelingRoadshow 3 ปีที่แล้ว

    Matt you need a A deluge gun, fire monitor, master stream or deck gun is an aimable controllable high-capacity water jet used for manual firefighting or automatic fire protection systems. Deluge guns are often designed to accommodate foam which has been injected in the upstream piping.

  • @BassManBobBassCovers
    @BassManBobBassCovers 3 ปีที่แล้ว +1

    Make sure the pump case is drained when/if below freezing outside or it will crack!!

  • @covert767
    @covert767 3 ปีที่แล้ว +61

    Matt, when running a load on a truck or a trailer that is near your max of the vehicle you need to center the mass over the axle as much as possible. Otherwise you're going to flex the frame and it's going to break. Just like your old flat trailer did.

  • @BIGWHIT76
    @BIGWHIT76 3 ปีที่แล้ว +52

    Just remember that the water in the tank moves. If you slam on the brakes all that weight is coming towards you. My father who was a milkman had a buddy who’s load came through both the box and the cab and crushed him.

    • @gooberclese
      @gooberclese 3 ปีที่แล้ว +2

      Yeah I would not trust a "headache rack" to stop a pallet of sponges much less 4500 lbs of tank and water. No thank you.

    • @aerialinterimmanager
      @aerialinterimmanager 3 ปีที่แล้ว +1

      Oh man that’s a bummer you think they would have accounted for that

  • @WaltWW
    @WaltWW 3 ปีที่แล้ว

    Mount the pump down low on the back of the truck and put a 1” rigid hose reel back there. You will have the pump accessible to start from the ground and you can gravity feed fuel to the motor from that big gas tank under the truck bed. Everything will be easy to access from the ground if you just mount it all on the back either under the truck bed to just above the back bumper area.

  • @oldanddisgusted5998
    @oldanddisgusted5998 3 ปีที่แล้ว

    Matt I have been a firefighter and instructor for 19 years I have some training videos to show you how to load and deploy that hose you have and make life easier until you get some booster line. Let me know.

  • @davidhinojosa9327
    @davidhinojosa9327 3 ปีที่แล้ว +15

    When you are not flowing water with the engine running, you really need to install a relief valve on the discharge so the pump isn’t dead heading. The relief valve routes the flow back to the tank.

    • @thomasgillis7632
      @thomasgillis7632 3 ปีที่แล้ว

      This is very important. Especially if you want to stop and start your discharging.

  • @aarontipton1981
    @aarontipton1981 3 ปีที่แล้ว +112

    Matt, I'm a firefighter in Wisconsin and definitely have some ideas that might help. I messaged you earlier when you picked up the OG chief about best practices with wildland firefighting.
    Either way, I'd love to help in order to make this all easier for you and most of all safer.
    Well, good luck and hope to help.

  • @kevinarnold9009
    @kevinarnold9009 3 ปีที่แล้ว

    You may have to go to 1.5” hose, we were running 160 gpm on a smooth bore nozzle training on a 1 3/4” hose and the hose was collapsing a little bit. With that fog nozzle you might be alright but you need to be able to keep the hose inflated so that it doesn’t kink then flail all over the place when it re inflates the kink. Plus if you get a four way valve you should be able to switch from pumping water to filling your tank just by manipulating the four way valve. Booster hose is more common for brush fires which would be the rubber cover solid hose that you put on a reel. Also if you make a plywood hose bed you can either do a flat load or a minute man load or probably five others that allow you to flake out the hose without kinks very quickly. Also our pumper trucks commonly only carry 1,000 gallons and full bore high flow multiple hose lines we can drain it in 7 minutes or less, so 500 is a significant amount. You can always reach out to wranglerstar, I am just in class right now, he actually has experience

  • @yakincubus
    @yakincubus 3 ปีที่แล้ว +1

    Hey Matt. why don't you turn the water tank sideways on the back of the truck then you will be able to access the valve from the ground. then is it possible to mount the pump on the chassis in the same way the diesel tank fits, maybe on a pull out frame then you can have total access to the pump from the ground too. I agree with your idea for a hard body hose reel as well, much easier and quicker to deploy and retract. Awesome job buddy!

  • @drimsey3527
    @drimsey3527 3 ปีที่แล้ว +157

    Hey Matt, I'm Vol Fire and one thing my department does is we keep a few metal rakes on our trucks to create a 2 foot gap of bare dirt from the burnt area and the non-burnt ground. this will eliminate the fire from spreading further. Awsome setup man hope this helps!

    • @baileymuller2590
      @baileymuller2590 3 ปีที่แล้ว +6

      Also known as a rake-hoe or MacLouds tool

    • @scottychainsaw5866
      @scottychainsaw5866 3 ปีที่แล้ว +3

      Extrremely underappreciated comment. I would have that thing loaded with any potentially useful tool for any scenario.

    • @paytoncobb1548
      @paytoncobb1548 3 ปีที่แล้ว +2

      this kind of thing is useful for farms too. when burning sloughs we always disc at least 25 feet out to create a firegaurd.

    • @stuartdubbs9605
      @stuartdubbs9605 3 ปีที่แล้ว +1

      God it's a rush digging fire line during a rogue flame. You've never see fire travel faster, its terrifying

    • @kdan3433
      @kdan3433 3 ปีที่แล้ว

      A good leaf blower works so much better to cut a fire line
      Rakes do have their place though

  • @trystyngaffney825
    @trystyngaffney825 3 ปีที่แล้ว +144

    Hey Matt, I am a firefighter from Florida. I can tell you that you need what we call in the fire service a “Booster Line”. It kind of wraps up as a garden hose does. Although it’s about 1” hose. It should do exactly what you need it to do.

    • @ritawant9492
      @ritawant9492 3 ปีที่แล้ว

      💋💥

    • @HondaRedWhiteAndBlue
      @HondaRedWhiteAndBlue 3 ปีที่แล้ว +1

      @@ritawant9492 you seem nice

    • @davidsanders1783
      @davidsanders1783 3 ปีที่แล้ว

      bruh coments im a fire fighter from florida -2 girls are hiting you up

  • @americansmark
    @americansmark 3 ปีที่แล้ว

    A bit of an FMCSA tip for you.
    Those straps will not hold that tank if even slightly filled should you take a corner at enough speed to side surge the tank (water sloshing side to side).
    The big flatbed semi straps are usually rated for 4500lbs each. Smaller ones that you buy for pickups around 2500-3000 each. You always want to have a 50% higher load rating at each end than you need, aka two straps or one oversize strap. So with the smaller straps, you want two at each end and one every 6-8' between to prevent load shifting.
    It seems like overkill, but once a load starts to move, straps will snap like guitar strings. I had a 10000lb solid steel ingot roll break 8 of the 9 straps and do 360s on my flatbed trailer, only managing to stay on because the lasts strap didn't give out. Chains with adequate tension bars are a much safer option until you bolt it down. A good chain and tension lock is rated for 8000-10000lbs. 3 would keep that thing in place forever.

  • @joeclark2882
    @joeclark2882 3 ปีที่แล้ว +1

    Hey Matt, I just wanted to suggest that you make sure the fuel is shut off during transport of that pump. Fuel can leak into the intake when the engine is off and vibrating, or if the tank is bouncing around. This fuel can then dilute your oil if it makes it past the intake valve and down the cylinder wall.

  • @schasegleason
    @schasegleason 3 ปีที่แล้ว +203

    Dad goals.... "here son come help me build this fire truck"

  • @davidh0809
    @davidh0809 3 ปีที่แล้ว +55

    Matt....two words....water cannon. I would expect nothing less for Demolition Ranch.

    • @TheFrogsPond
      @TheFrogsPond 3 ปีที่แล้ว +1

      I was thinking the same thing as soon as he said he wanted to hose things from the truck.

    • @BS-nz8lr
      @BS-nz8lr 3 ปีที่แล้ว +1

      Was thinking same he has to do it

    • @Teodede
      @Teodede 3 ปีที่แล้ว +2

      Me either, but that’s likely gonna be $3000 pump and a much larger tank. With just the nozzle he has right now he will be through that 500 gallon tank in about 5 minutes.

    • @the_retag
      @the_retag 3 ปีที่แล้ว

      @@Teodede he can use a small watercannon, doesnt have to be the airfield size. And the pump may need changes, but not a new 3k pump (although id use a pto pump anyway

  • @kennethfeld6639
    @kennethfeld6639 3 ปีที่แล้ว

    Hose reel - use a solid hose. For a fire hose then make a bin to hold it folded and if you need it grab the nozzle and run to get it all off the truck.

  • @noahkieswether671
    @noahkieswether671 3 ปีที่แล้ว

    We use cam locks for our jet refuelers. Handles the pressure fine, tend to leak a little in very cold temps, shouldn’t be a problem in Texas. Also always need an emergency shut off, the valve works for that but it needs to be easily reachable

  • @seanthompson6720
    @seanthompson6720 3 ปีที่แล้ว +150

    you should connect a scuba tank up to your helmet when doing a burnout at cleetus and cars so you don't choke on the smoke again

    • @thomasohanlon1060
      @thomasohanlon1060 3 ปีที่แล้ว +7

      Yep remember the helmets for the trophy truck with the air hose connectors, perfect use.

    • @jordanwalters9255
      @jordanwalters9255 3 ปีที่แล้ว

      Gnarly electric fan would even help

    • @BrokeWrench
      @BrokeWrench 3 ปีที่แล้ว +4

      Little emergency scuba tanks that just hang down from the mouthpiece. Should last plenty long enough for the world's best burnouts

  • @mammaletsplay5295
    @mammaletsplay5295 3 ปีที่แล้ว +141

    Hey Matt, you should consider putting in a swimmer in the tank, that messures the waterlevel, to shut your pump of if the water level gets to low, because pumps dont like to run dry and you dont have to monitor your water level manually why hosing down. Recirculate your water to the tank while you are not hosing to prevent overheating your pump. If you want to pump in water from sa lake or stuff like that take a mesh with you for your succionhose that goes into the pond to prevent debree entering your pump, small stuff shouldnt be that much of a problem but a stick could damage your pump

    • @alexanderchezem1932
      @alexanderchezem1932 3 ปีที่แล้ว

      J's connect it cause if not it may get lost when u shit it off like fall in the pond or water soirce

    • @mikeymorehead
      @mikeymorehead 3 ปีที่แล้ว

      Water cannon on the side of the bed.

  • @jardolin
    @jardolin 3 ปีที่แล้ว

    Hey Matt. Maybe someone has already said this, but if you want to be able to swap the direction of that pump, to fill your tank, you need 2 2” cam fittings. Put the reducer after the cam fitting.

  • @randallthomas5207
    @randallthomas5207 3 ปีที่แล้ว

    Suggestion number one. Swing by your local volunteer fire department and talk to them. They will know what you need on the truck. Suggestion number two: Get a new tank with baffles in it. If the water sloshes around and you’re side hilling to get to the fire, it can roll your big ole truck right over.

  • @bobthbulder2085
    @bobthbulder2085 3 ปีที่แล้ว +28

    Hey Matt, the only bad thing about filling half way is that when your driving the water will slush around possibly causing an accident or unbalance

    • @Spotvogel
      @Spotvogel 3 ปีที่แล้ว +2

      It needs metal slids/walls/brakers to stop the waves/slushing, you see it in real fire engines and tank trucks and ofc in oil tankers too

  • @toddmedak7183
    @toddmedak7183 3 ปีที่แล้ว +18

    you need a hose reel, and you need to move the tank towards the back wheels a couple feet (the get the weight more balanced over the back.

  • @justice4jjproductions317
    @justice4jjproductions317 3 ปีที่แล้ว

    Some sort of lowering shelf to put the pump on for quick access that also holds a hose reel. Fire starts you unlatch the shelf pull down the pump open the water feed and start the pump, pull out hose, and be a hero....😉

  • @donnajohnson6087
    @donnajohnson6087 3 ปีที่แล้ว

    Suggestion... You could mount the water pump below the bed but even with fuel tank to use as a siphon if you’re going to draw off the chassis fuel tank and then you can put a motorized terret system on the bed so you can operate with push button in case of small fires and you could still use the hose for big fires that are far away.

  • @gabeolguin6630
    @gabeolguin6630 3 ปีที่แล้ว +169

    Touching on what Jamie said, the 1 1/2 hose you have is primarily for structural fire “residential and or big buildings” booster hose is a soft hose that is used in the forestry service. This hose can be reeled up and is very easy to move around and manipulate. You’d be sacrificing some water pressure for it because it is not as big in diameter but it will far better useful for what you are using it for instead of the structural fire hose. Generally the 1” hose nozzles have “smooth bore” and is just a solid stream of water instead of your fog stream. Careful on water hammering your pump... I’m not to sure if booster line you have to care to much about it but to be safe and not damage your pump just close the nozzle a little slower that way your hose doesn’t burst or if damages your pump.

    • @KingDavidtheRed1
      @KingDavidtheRed1 3 ปีที่แล้ว +1

      You, Sir, are 100% correct in everything you just said!

  • @joshmorrissey8922
    @joshmorrissey8922 3 ปีที่แล้ว +57

    For the shorter hose, you should just buy a short hose on with a cam lock and have the large one in a spool so if you need to change it just unroll the large one and switch the cam locks in like 10 seconds

    • @footloose9618
      @footloose9618 3 ปีที่แล้ว +1

      just what i was thinking

    • @americaproud9344
      @americaproud9344 3 ปีที่แล้ว +1

      Would a splitter work? So that way he just chooses what one he wants with out having to switch and hoses.

  • @brendansprowls9449
    @brendansprowls9449 3 ปีที่แล้ว

    All you need is a 1" hardline or wildland fire hose. 2 1/2" hose is used for big fires. Also get a tank with baffles so you dont get water hammered while driving or flip. You also want to flow the pump at which the nozzle is rated, that makes it flow the best.

  • @charleslynch7274
    @charleslynch7274 3 ปีที่แล้ว

    Very kool glad ur happy with the pump you will figure it out as u go no need to stress urself

  • @swadenater
    @swadenater 3 ปีที่แล้ว +196

    Fire truck engineer here: Went to the comments to see how many were yelling at Matt about him first saying he thinks the intake is the top and the discharge is bottom. Now I'm laughing at the amount of Firefighters showing up in the demolitia with awesome advice. Stay safe out there brothers!

    • @FuckTheState
      @FuckTheState 3 ปีที่แล้ว +5

      The wrong intake issue is an OCD trigger.

    • @orienlouttit6160
      @orienlouttit6160 3 ปีที่แล้ว +1

      I did the wait I think that is wrong. Not a fire fighter but I have marine fire fighting training (I work on a ship)

    • @CharlieForbes524
      @CharlieForbes524 3 ปีที่แล้ว +1

      Isn't a plastic tank for use around fire a bad idea?

    • @PhilG999
      @PhilG999 3 ปีที่แล้ว

      Former Pump and Compressor Sales Engineer (years ago). Immediately thought he had those fittings reversed! He he he finally RTFM!

    • @chrislettenmaier6822
      @chrislettenmaier6822 3 ปีที่แล้ว

      I’m a plumber and use that type and many other pumps. When he pointed at the top of the pump and called it the intake I started to shake my head saying no. He had it backwards intake to any pump feeds straight into the pump first.

  • @tacticalwagon124
    @tacticalwagon124 3 ปีที่แล้ว +677

    me wait for the "filling my water tank with gasoline and making the biggest flamethrower" video

    • @captaincouldverc
      @captaincouldverc 3 ปีที่แล้ว +10

      My hero!
      Hahaha haha

    • @sebastiend.5335
      @sebastiend.5335 3 ปีที่แล้ว +3

      Epic!!

    • @M_u_t_e96024
      @M_u_t_e96024 3 ปีที่แล้ว +5

      He will need a different house an nozzle for that one

    • @masonweir2163
      @masonweir2163 3 ปีที่แล้ว +2

      This has to be a thing

    • @davidmtwigg
      @davidmtwigg 3 ปีที่แล้ว +19

      And get a second fire trunk to put out the first. 🙄