Very nice video with real life example containing technical details. What kind of warranty is available for this 6.5 kw system. How much budget range, should I look for a similar system?
Nice information sir please make video on single phase 3 kw micro inverter ongrid solar system with diagram and specifications of the DC and AC wires used in the system as per MSEDCL GUIDELINES.
Very nice video. I believe you're not providing service in Chennai area. Quick question, for a 5KV system can you suggest us what kind of ACDB box we should buy in the market? Is it available online? Thanks in advance.
Sir, Thanks for the comment . I assume you are talking about the single phase system. While I would not recommend any off the shelf ACDB, I suggest you get a custom made ACDB with the following components: 1. SPD , preferably 275V type 2 or type 1 + 2. 2. ELCB; 20A; 30/100mA sensitivity. 3. MCB: 20A, 4. Over Voltage protection relay. 5. Contactor for the relay. Plus I would recommend a type 1 + 2 SPD at the mains incomer .
so what happens when a panel has a different power output than another, and then you connect in pararllel the micro inverter, does this work seperatelly?
Sir can we use Enphase iq7 series of microinverters with Bifacial Panels with peak watt capacity of 540 watt? When are the IQ8 series of Enphase likely to be available in India?
very good information I want to ask, in a 3 phase installation what is the basis for determining the number of inverters for each phase. based on the installation you made, there are only 4 blue inverters
Hi Sunil, Good video. I have a doubt, there is some information that if the voltage from the grid drops below 190V, the micro inverter stops working and won't generate any power. Is it true. When there are too many houses connected from one transformer, there are chances for low voltage.
I'm following your videos and getting fruitful knowledge about the overall concept of Rooftop Solar Installations. Do you provide any kind of training to the young people who wants to come into the business of Rooftop solar installations. If yes , please provide your contact number. Thank you in advance and keep up the good work.
@Henren Engineering , Sir, Your videos provide me good knowledge about solar power, our kind request you to provide the series of online solar power classes for us
very good technology but a highly less efficient inverter ever in the market. maximum efficiency is about 70%. too much innovation is needed. enphase should improve its product. because even string inverters are much more efficient.
Your setup in this video is really impressive. Especially how you have tagged and labled all the components.
Boss,
Hats Off.
Absolutely tidy wire harnessing.
I wish you a great success.If customers understand the price of neat job.😁
Thanks 👍
I am so impressed with your useful narration
Excellent work. Thanks so much for sharing.
Great explanation, thanks for the good job!
Thank you
Very informative! Thank you!
Hello. Impressive work.
Could you also provide cost incurred and breakeven period?
Very Nicely Explained. Appreciate your Vedio coverage foot prints.
Thank you very much
Sir your installation including structure is very good.
Thanks a lot
Very nice video with real life example containing technical details. What kind of warranty is available for this 6.5 kw system. How much budget range, should I look for a similar system?
Sir, I want to know from you.
PCS fullmeaning?
PV fullmeaning?
When will you come to tamilnadu
Good explanation!
How calculate the 3phase AC Wire size for output from Inverter .....
Do you provide services in Delhi NCR.
Have you given option for earthing in this installation
Of course, Structure ans SPD are earthed. A lightning arrester is also provided .
Doesn't it mean that in this particular case the user net exported 1.4kWh to the grid and got nothing for their troubles?
Nice information sir please make video on single phase 3 kw micro inverter ongrid solar system with diagram and specifications of the DC and AC wires used in the system as per MSEDCL GUIDELINES.
this is really very useful video
Very nice video. I believe you're not providing service in Chennai area. Quick question, for a 5KV system can you suggest us what kind of ACDB box we should buy in the market? Is it available online? Thanks in advance.
Sir, Thanks for the comment .
I assume you are talking about the single phase system.
While I would not recommend any off the shelf ACDB, I suggest you get a custom made ACDB with the following components:
1. SPD , preferably 275V type 2 or type 1 + 2.
2. ELCB; 20A; 30/100mA sensitivity.
3. MCB: 20A,
4. Over Voltage protection relay.
5. Contactor for the relay.
Plus I would recommend a type 1 + 2 SPD at the mains incomer .
Nice video
Very nice 👍👌
so what happens when a panel has a different power output than another, and then you connect in pararllel the micro inverter, does this work seperatelly?
Yes each panel will work independently
Just with the weight of the structure weight will it withstand heavy winds?
Designed factoring in local wind conditions
Very well explained!!!!
Can you add a battery back up for the installation explained in the video
Yes you can th-cam.com/video/-zm0NMKW7k4/w-d-xo.html
For this ongris system can we use power back inverter during power outage
I like the quality of your components and the structure. What is the thickness of Rafters and Purlins used? 1.6mm or 2 mm?
Awaiting your reply
Unfortunately no service in Hyderabad
Sir the video is so informative and keep going.Sir may I know details of the cable mounting clip and also the hilti make panel clamp used.
Hi Sunil, how much will it cost me if I install this same system system with a backup ?
Sir, size (sq mm) of the 4 core cable from terminal block till ACDB and also, Size of the 2 core cable between the microinverter till terminal block ?
How 120degree phase shift for RYB is achieved here?
How much Kw is required for building with 4 numbers of 2BHK house ??
Does micro inverter justify it's cost?, I think it is much more costly than they worth
Nice work 👏
nice
Sir can we use Enphase iq7 series of microinverters with Bifacial Panels with peak watt capacity of 540 watt? When are the IQ8 series of Enphase likely to be available in India?
Sir you cannot use IQ 7 series with 540 watt panels .
I have no idea about iq 8 availability.
IQ7A support a mx of 500W. IQ8 may be availble by the end of the 2022
very good information I want to ask, in a 3 phase installation what is the basis for determining the number of inverters for each phase. based on the installation you made, there are only 4 blue inverters
Namaste Sir,
It is best to divide the number of inverters equally among all the three phases.
you can have different numbers in the three phases. I have 5,5,4. Isnt a challenge.
Hi Sunil, Good video. I have a doubt, there is some information that if the voltage from the grid drops below 190V, the micro inverter stops working and won't generate any power. Is it true. When there are too many houses connected from one transformer, there are chances for low voltage.
Yes true . Not only with micro Inveters but any grid tied inverter .
Semoga cepat masuk di Indonesia
Where I can get phase coupler
Structure dimension details
Micro investor is high invest cost for project more than 5 kW .
It is better for less than 5kw system .
Sir Hindi me bnao video plz🙏
I'm following your videos and getting fruitful knowledge about the overall concept of Rooftop Solar Installations. Do you provide any kind of training to the young people who wants to come into the business of Rooftop solar installations. If yes , please provide your contact number.
Thank you in advance and keep up the good work.
Thank you .
We don't provide any structured training programs.
However some interested people come and take a look at the installation at sites.
@Henren Engineering , Sir, Your videos provide me good knowledge about solar power, our kind request you to provide the series of online solar power classes for us
How much earning money for a month
Hindi ma
very good technology but a highly less efficient inverter ever in the market. maximum efficiency is about 70%.
too much innovation is needed.
enphase should improve its product. because even string inverters are much more efficient.