True Reach in cooler is not cooling

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 เม.ย. 2023
  • in this refrigeration training video, I will troubleshoot a reach in cooler that is running warm and will go over the R134A Pt chart, refrigeration pressures and saturation temperatures.
    Instagram / refrigerationkitchentech
    Facebook / rketec
    Linked in / refrigerationkitchentech
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 89

  • @billyhorton5779
    @billyhorton5779 ปีที่แล้ว +8

    Thanks for taking the time to explain the proper procedure to troubleshoot "a not cooling" reach in. The explanations along the way are based on your personal experience of having done this countless times. That is my definition of a true professional!

  • @frankduarte7109
    @frankduarte7109 5 หลายเดือนก่อน

    Good video man watching these like crazy now . I was a residental tech just got a refrigeration /light commercial job and we work a lot with ice machine and true fridges and freezers these videos are a big help

  • @iShujaat
    @iShujaat 10 หลายเดือนก่อน

    🙏 for months I have been asking many tech how to find out my pressures. Thanks

  • @kaloiankrastev6851
    @kaloiankrastev6851 ปีที่แล้ว

    You are the best hvac teacher that i know ! Thanks one more time! It make my ref work going smoother and smoother!

  • @youtubeuser7511
    @youtubeuser7511 18 วันที่ผ่านมา

    It Truly is a reach in cooler, bro!

  • @Bigshot31
    @Bigshot31 ปีที่แล้ว

    Wow by far the best on TH-cam ❤

  • @bobbytsiamis8553
    @bobbytsiamis8553 ปีที่แล้ว +1

    Changed a coil on small true prep table last week. Thought my cap tube was clear, unit ran with good pressures before replacement. After replacement pressures were low and unit cooled but wouldn't cycle off on coil sensing thermostat. Replaced the cap tube and all was well. Didn't think about flowing nitrogen at operating pressures to check for restriction. Great tip!👍👍👍

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  ปีที่แล้ว

      Yup, got burnt on that years ago and wasted almost 2 days trying to resolve the issue.

  • @sergiomateo7671
    @sergiomateo7671 ปีที่แล้ว +1

    As soon as you mentioned the cap tube cutter, I stopped the video, googled it and bought it. Lol. I have heard of it but if it say it works better, I believe you. Next time put a link in it so you can get a commission. Lol.
    Thank you for taking the time to teach us. Know that there are many guys learning from what you do.

  • @ronchambers9762
    @ronchambers9762 ปีที่แล้ว

    Thank You Sir. I hope your day is healthy and happy 😊

  • @arslanahmed8504
    @arslanahmed8504 10 หลายเดือนก่อน

    Amazing. Thank you

  • @miguelrojas3394
    @miguelrojas3394 ปีที่แล้ว

    Great video well explained, thank you 🙏🙏👍👍.

  • @christianurbano1483
    @christianurbano1483 ปีที่แล้ว

    thanks a lot for your educational vids.

  • @zekenzy6486
    @zekenzy6486 ปีที่แล้ว

    Great Video. Thank you for sharing

  • @BillyN31
    @BillyN31 ปีที่แล้ว

    I do mostly hvac without the R. But I liked your video and training/advice

  • @mrcalifornia_7177
    @mrcalifornia_7177 ปีที่แล้ว

    Im a resedential tech 13 years ,been in industrial refrigeration (ammonia) for 13 years now .but all these commercial things are my next challenge im thinkn of looking into this field so i can be well rounded in all my trade

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  ปีที่แล้ว +1

      Will be an easy transition for you. Once you know what the saturation temps need to be, the rest is simple

  • @thesilentonevictor
    @thesilentonevictor ปีที่แล้ว

    Great job tech

  • @harrydickson4575
    @harrydickson4575 ปีที่แล้ว +1

    Excellent job 👍👍👍

  • @jrh86
    @jrh86 11 หลายเดือนก่อน

    Very helpfull 👍👍👍💯

  • @ZeEnderCat777
    @ZeEnderCat777 4 หลายเดือนก่อน

    Do you have any videos where you record yourself installing an evaporator coil in a reach-in? That would be amazing to watch. Must be so tight!

  • @manhpham8052
    @manhpham8052 ปีที่แล้ว

    i brazed the cap tube to the evap end shut 1 time. 😂 ; thanks for the sharing the nice trick to test to see if the cap tube brazed shut

  • @musakavalci9470
    @musakavalci9470 ปีที่แล้ว

    Thanks again 🫡

  • @ChadTinko
    @ChadTinko หลายเดือนก่อน

    What program do you use for your sequence of operations

  • @manschool4992
    @manschool4992 ปีที่แล้ว

    Where did you gauge up? I'm a light commercial rooftop tech now working in a fixed facility with low temp, chillers, boilers, FCUs, AHUs, and WSHPs. I tried to service a True this morning and I was as lost as one could be. Did a leak search. Nothing. Cooler/Freezer split. Freezer is fine. Cooler at 61 F. Couldn't find anywhere to put my gauges. It's probably right in front of me. You low temp guys are amazing.

  • @MichelleOrmsby
    @MichelleOrmsby 2 หลายเดือนก่อน

    What would cause a T-23G to cool for about a week and then go to ambient temp ?

  • @Bosh-ed1jz
    @Bosh-ed1jz หลายเดือนก่อน

    How do you replace the cord if its burnt out on the socket end that you plug in the wall socket?

  • @wisconsinbush2940
    @wisconsinbush2940 9 หลายเดือนก่อน

    How do you determine the high and low pressures on a small appliance that has 6 ounces of Freon.

  • @MrCstone1
    @MrCstone1 10 หลายเดือนก่อน

    Nice video! I have close to the same cooler. It stays cool for 2 days then the temp rises 20° unplug it for a day does the same thing. Any suggestions?

  • @jorgeLopez-xn9uy
    @jorgeLopez-xn9uy 10 หลายเดือนก่อน

    3:33 what is the TD for a walk in refrigerator?

  • @sengle9831
    @sengle9831 ปีที่แล้ว

    Sometime I use wire striped to cut cap tube it works great.

  • @smackdaddy1ful
    @smackdaddy1ful 10 หลายเดือนก่อน

    how do you know what the diff is for head pressure???

  • @ansabansaf9163
    @ansabansaf9163 10 หลายเดือนก่อน

    Hello dear what is the issue of true 2 door chiller upside 32f and dowside 50f in true T-23-2

  • @arjunapeiris981
    @arjunapeiris981 ปีที่แล้ว

    👍👍👍

  • @itcpapi6132
    @itcpapi6132 ปีที่แล้ว +4

    Great video, great teacher. Quick question. How do you get your evap td and your condenser split? I notice that its different for different units.

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  ปีที่แล้ว +2

      Reach in evap td is 20F. Condensor can be either a 15F or 30F, a lot of the newer stuff is a 15F split

    • @itcpapi6132
      @itcpapi6132 ปีที่แล้ว

      What determines if its 15 or 30 Condenser split? I know you said the newer stuff is 15 but how would i know while diagnosing a unit?
      Also, whats the evap td for a walk in cooler and walk in freezer?

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  ปีที่แล้ว

      The engineer will decide, but based on your suction pressure, you will be able to figure out if it a a 15 or 30 split. Walk ins are a 10TD evaporator coil, but your superheat will determine the TD.

    • @mrcalifornia_7177
      @mrcalifornia_7177 ปีที่แล้ว

      Exactly my thoughts ..how do u know your td ??

  • @shine-cg9uf
    @shine-cg9uf ปีที่แล้ว

    👍🇺🇸💪❄️ great job.. u said 15cs but then 30cs on diagram. Most cs r 30 for coolers correct? Some may b 15 depending on yr of unit ?

  • @isidrobedolla2894
    @isidrobedolla2894 ปีที่แล้ว

    How do you find the evaporator and condenser TD? If there is no data plate or stickers?

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  ปีที่แล้ว

      You can try to contact the manufacturer. You eventually get the hang of it and can figure it out on your own

  • @jorgegomez973
    @jorgegomez973 ปีที่แล้ว

    How do you know the condenser temperature split.? It’ll help a lot that information thanks

  • @shifter8207
    @shifter8207 ปีที่แล้ว +1

    Where did you come up the high side td of 15 and low side of 20 td? High side seems low and low side seems like high td

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  ปีที่แล้ว

      Almost all reach ins have a 20F evaporator td. Condensor is either a 15F or 30F split depending on what the engineer has designed it at. Almost all the newer stuff will have a 15F Condensor split to help with efficiency ratings.

    • @shifter8207
      @shifter8207 ปีที่แล้ว

      @@REFRIGERATIONKITCHENEQTECH thanks I was thinking the condenser was still at 30 didn’t know that reach in s can have that low of a split

  •  10 หลายเดือนก่อน

    can you explain evap td

  • @davejohnsonnola7908
    @davejohnsonnola7908 ปีที่แล้ว

    Don't know if there is an advantage or not but I use that cap cutting tool at a 45 degree angle.

  • @SombraLocs
    @SombraLocs ปีที่แล้ว

    Do you have a link for that cap tube cutter?

  • @eklazhward4739
    @eklazhward4739 ปีที่แล้ว

    hey, in 6:03 you mention, that you braze cap tube shut to evap.coil. What exactly mean "shut braze" it is something different than just braze copper with copper ? I'm not native-english and I don't know technical terminology

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  ปีที่แล้ว

      The new filter dryer comes brazed shut, so I don’t cut it until after I push nitrogen through

  • @whitesheatingairappliancer7101
    @whitesheatingairappliancer7101 ปีที่แล้ว

    Are you guys using a solvent to flush out a clogged cap tube?

  • @armandolopez6365
    @armandolopez6365 ปีที่แล้ว

    Dumb question what is Evap td and how do you get that number ?

  • @JohnJohn-nu8ql
    @JohnJohn-nu8ql ปีที่แล้ว

    Do u do live chat?

  • @rocker8692
    @rocker8692 ปีที่แล้ว

    I'm a maintenance tech,is 47 to old to be a refrigeration tech,I know it's not what most companies want,but I'm alot more interested in this and commercial cooking equipment.

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  ปีที่แล้ว +1

      It’s never too late to learn if you put the work in. I’ve had techs trained in 6 months and dominating by year 2. It’s all who is teaching you and how much work you are willing to put in to learn.

    • @juliochavezunacosa4147
      @juliochavezunacosa4147 ปีที่แล้ว

      I was 51 when switch my glazier trade to refrigeration

    • @REFRIGERATIONKITCHENEQTECH
      @REFRIGERATIONKITCHENEQTECH  ปีที่แล้ว

      ⬆️ 👍

    • @davejohnsonnola7908
      @davejohnsonnola7908 ปีที่แล้ว

      I got the Hvacr community college degree in the late 80's but never went into the field. 25 years later came back to it and still learning today at 62.

  • @MarkRouleau
    @MarkRouleau 11 หลายเดือนก่อน

    30% of a new unit? How much is a new unit?

  • @ChadTinko
    @ChadTinko หลายเดือนก่อน

    What program do you use for your sequence of operations