True GDM-26: No Cool troubleshoot

แชร์
ฝัง
  • เผยแพร่เมื่อ 17 พ.ค. 2023
  • True GDM-26 cooler not cooling. Checking compressor and start components.

ความคิดเห็น • 24

  • @wisconsinbush2940
    @wisconsinbush2940 5 หลายเดือนก่อน

    What is it when the condenser fan motor isn’t running with the deck plugged in and compressor isn’t running?

  • @shine-cg9uf
    @shine-cg9uf ปีที่แล้ว +1

    🇺🇸👍💪❄️ nice video any follow-up is the unit still running after replacing start components ? Thanks for sharing

  • @TheDave5619
    @TheDave5619 10 หลายเดือนก่อน

    Nice diagnosis! I work on coke’s equipment

    • @damianflores2091
      @damianflores2091 6 หลายเดือนก่อน

      Any recommendations on where to start checking a GDM-15EM? NOT COOLING

    • @TheDave5619
      @TheDave5619 6 หลายเดือนก่อน +1

      @@damianflores2091I believe these are retro looking coolers? If so just start with the simple diagnoses.
      Is there power?
      Is the evaporator fan running?
      Is the evaporator frozen?
      Is the condenser fan motor running ?
      Is the compressor running?
      Is the condenser coil dirty?
      If these all check out it’s most likely something relating to the refrigerant. And you would have to gauge up.
      If one of those questions above does not meet with the requirements then it will be something in that field. Bad fan motor, bad starting components on the compressor (as seen on the video ) or a bad thermostat.

    • @fdelacou
      @fdelacou 6 หลายเดือนก่อน

      @@TheDave5619 Got a GDM-15 Retro not cooling with a PF2 (faulty condenser temperature) message during test. I believe everything else is working. Compressor, fans (cond & evap), lights are turning on, everything is clean.. Thoughts on how to troubleshoot further?

    • @TheDave5619
      @TheDave5619 5 หลายเดือนก่อน

      @@fdelacou sorry for the late reply. I read online PF2 is a Evap sensor. Is this a dixell controller ? The one you’re working on?

    • @fdelacou
      @fdelacou 5 หลายเดือนก่อน

      @@TheDave5619 Thank you for the reply. I actually figured out the PF2 mystery.... There is no sensor connected to the EMS controller. So it's only "natural" that is is giving a PF2 message! :-D
      My next step is to figure out why it's not cooling. I get some warmer copper tubing going to the condenser and the copper tubing coming out is colder. I havent had a chance to measure the exact differential temperature just yet compared to the air in my workshop so it's my next step. I suspecting that the unit might need a reload of freon since it does not show any signs of having been serviced since 2016.

  • @jacobbarnett9956
    @jacobbarnett9956 3 หลายเดือนก่อน

    Picked up this machine or something similar for free on the side of the road yesterday, upon plugging it in it started heating the inside lmao

    • @ashercooper4017
      @ashercooper4017 2 หลายเดือนก่อน

      I got one on marketplace for $100 and he said it was doing the same thing lol. I’m going through trying to troubleshoot everything. Did you find a solution?

    • @jacobbarnett9956
      @jacobbarnett9956 2 หลายเดือนก่อน

      @@ashercooper4017 I haven't done much yet, I'm not very fridge inclined. It's on my list of things to do tho lmao

    • @ashercooper4017
      @ashercooper4017 2 หลายเดือนก่อน

      @@jacobbarnett9956 I feel you lol. I spent 45 minutes cleaning the inside and I slide the compressor out and blew everything out and started learning about how to fix a fridge. Whole new skill I’m learning right now lol. I’ll update if I find the easy fix for it

  • @joesmith7427
    @joesmith7427 9 หลายเดือนก่อน

    What about the thermostat if it bad?? What about the line tap?? What type of pressures should the unit run at?? How much are the parts?? $$$

    • @l2kxboost
      @l2kxboost 7 หลายเดือนก่อน +1

      For you, minimum of $400 because of all the questions. You sir would be over our shoulder during the whole process.........

    • @l2kxboost
      @l2kxboost 7 หลายเดือนก่อน

      Must be related to the lower case patels .

    • @SombraLocs
      @SombraLocs 3 หลายเดือนก่อน +1

      ​@@l2kxboostworst customers ever.

    • @johnmartinez4943
      @johnmartinez4943 2 หลายเดือนก่อน

      Leaks are kind of rare. 9/10 it's a component along the way. Condenser fan kicked on, so t-stat seemed ok. Pressure isn't something you want to measure unless you suspect leak, you never really want to open these up. Parts cost, no idea but it's easy enough to find. You can get a hard start kit with your specs and it's cheap and easy to find and will solve the problem, though not ideal.