First of all..from my knowledge of engineering.. 1. side bars for the beam is not required if the depth of the beam is not too large. 2. In Stirrups for the beams there should be two hooks (135 degree bend) at the two ends..which are missing as seen in the video.. 3. In some beams top reinforcements are placed very close to each other.. according to design code there should be minimum distance between two reinforcement bars..
About bottom reinforcement, some people do support the cantliver especially in rural areas so i think it's save option to design as cantliver and supported beam in the same time
Hello 👋 thanks for your suggestions, but DO SHOW BY POINTING AT EACH PART OF THE ASSEMBLED STRUCTURAL DESIGN ELEMENTS OF MS Bars, using a stick or pointer showing those defects that would be more beneficial to understand. 🙏🏻🙂Thanks 👍
Nice one please make use of arrows to point out where there is a problem with a corresponding image of the proper corrections...sometimes getting your words seems difficult because of speed and accent so please subtitling should adopted.thanks
1. the max length of the cantilever beam mostly governed by the effective length of the last fully supported girder. 2. the number of top rebar of the cantilever beam is determined by the top rebar of the last span girder
Hello, I am a Structural engineer currently working at The Naga Architects & Co. Can you please upload a video based on long span cantilever beams regarding its structural design? The types of binding and design tricks for say 6-9ft span cantilever?
The Engineer analyzed and designed the structure and shown on the plans but the Foreman did not follow the structural details. Maybe some of your observations are correct but it will be better to see the plan first as reference and make the best comment.
First of all..from my knowledge of engineering..
1. side bars for the beam is not required if the depth of the beam is not too large.
2. In Stirrups for the beams there should be two hooks (135 degree bend) at the two ends..which are missing as seen in the video..
3. In some beams top reinforcements are placed very close to each other.. according to design code there should be minimum distance between two reinforcement bars..
So please, shows us the right rods We will use in the next video.
Can you do a video of how to reinforce a correct cantilever beam and it's development bend,thank you.
Yyyyyyy you can
GOOD INFORMATION BUT LACKS THE INFORMATION AS TO HOW THE CANTILEVER BEAN STRUCTURE SHOULD BE.
What did you andestand from this video please.
No information as to hom the cantilever Beam struktur should be..like viddeo ..sktcch drawing or any things
About bottom reinforcement, some people do support the cantliver especially in rural areas so i think it's save option to design as cantliver and supported beam in the same time
Nice one. Pls try subtitling your videos for more clarity. Thanks.
Hello 👋 thanks for your suggestions, but DO SHOW BY POINTING AT EACH PART OF THE ASSEMBLED STRUCTURAL DESIGN ELEMENTS OF MS Bars, using a stick or pointer showing those defects that would be more beneficial to understand. 🙏🏻🙂Thanks 👍
Dear brother, your videos are nice, are you structural engineer?
Interesting but a few sketches would not go astray, to demonstrate your points.
Yeah a overlay of a colored bar the correct way on the video showing the proper way.
Please sir make a video on it and do some correction so that we can know it.
This video is very useful & experience for engineers before avoid the mistake.
So did you correct it for the sake of occupants and public safety?
How on earth can a project like this lack structural engineering drawings????
That scaffolding and formwork looks dodgy as hell!!! If it fails you won't even have a cantilever balcony to worry about.
In India we do like this way only
@@chintureddy9254 😂👌
Nice one please make use of arrows to point out where there is a problem with a corresponding image of the proper corrections...sometimes getting your words seems difficult because of speed and accent so please subtitling should adopted.thanks
Sir kya hum beam ka size 9/12 ke skte h G+3 ke liye aur sariya 6 12mm ke use krte h kya
1. the max length of the cantilever beam mostly governed by the effective length of the last fully supported girder.
2. the number of top rebar of the cantilever beam is determined by the top rebar of the last span girder
Build a concrete house without any belt concrete.can this damage house
can be construct full length wall on cantilever beam for room purpose?
Cantilever length is 1.2m please
اسلام علیکم۔۔۔۔۔۔عام بندے کو بھی سمجھا دیا کرین۔۔۔۔۔۔۔شکریہ
Sir ,on 2 feet cantilever can I construct another room by 10mm wall.
That's a throughout beam extended as cantilever so it's ok as per the cantilever perspective .
What is the maximum length of cantilever beam? Weight capacity?
Hello, I am a Structural engineer currently working at The Naga Architects & Co. Can you please upload a video based on long span cantilever beams regarding its structural design? The types of binding and design tricks for say 6-9ft span cantilever?
for Cantliver reniforcement should be placed at compression fibre not in tension fibre .it was big mistake .
Only mentioned problem
Who will tell solution then?
No CC in slab rebars?
Ram Ram bhai from Nepal🇳🇵🇳🇵🇳🇵🇳🇵
Use the max. Moment to design a cantilever beam, get the dimension and bars using the bending moment..
Good idea ser
Least of your worries is the bars running across. It's the whole thing
If the house is no longer to be extended in future.. why is development bar so important
Show us correction in next video... please...
How the rules in your life my problem also be vahan se message cha khelam
The Engineer analyzed and designed the structure and shown on the plans but the Foreman did not follow the structural details. Maybe some of your observations are correct but it will be better to see the plan first as reference and make the best comment.
Good i like👍🙏
IF YOU COULD PROVIDE CORRECT ONE ,LIKE IN DRAWING ATLEAST WOULD HELP
Very informative video
Make solution one video plz
Sir, find water tank Design.when his size 7*5*6 feet.
Even the slab reinforcement at the edge was not returned
Great analysis
Engineers always makes mistakes in plans and foreman always fix it. Lets be honest theory doesnt always work on actual
I understand only some if the words he is saying so I didn't like the video.
Can we build a toilet in 4’ cantilever of 9” by 12” column where spacing between two coloumn is 3.5m center to center
Please reply Asap 🙏
Short span shoulb be bottom first
Good bro
Are u structural engineer ?? It seems not!,,,
I hope everbody will be fine
Highlight the problem clearly....and explain it
Also missing 135 angle in the rings
Baraka lahou fikkk
Good
Top should be 3 and below only 2.....
Btw...thing slab will work
Hindi bhai it's comfortable for all
Then why you are there?
Sir ap ek Indian ho Hindi mein kyun nahin samjhate
Tell solution
Maximum nahin More number
2.3m is too long
Mag tagalog ka. Hahaha
Alaka pakhto kay o waya
Jai shri ram 🚩🚩
ज
Mistaken
One way slab?????!!!!!
it's economical one way
Mistake edea good Intruction.
Got it