AVI OR ACI ke liya hume AI1 configuration menu (204.0) me jana hoga Agr hum voltage input Drive me dete h to voltage ke liya do option h 1:0-5Vdc 2:0-10Vdc Or ACI (Analog input ) ke liya hame 204.0 me 0A select karna hota hai
2 motor VFd synchronizing karna hi bina port ka jo on off push batan ho riale push batan se increase ho decrease ho sir please help me with perameter seting videos banye please apke video mujhe bahut aacha laga
110 kw 2 motor hi 2 VFd hi Jo model no hi atv 630c11n4 isko synchronizing karna hi on off push batan se with single port se jo speed bade to dono Kam ho to dono sir please ek video banye please
Inching(jog) ka direction change kaise karte hai sir please explain ? Mujhe start aur jog dono me reverse direction chahiye. Start ka toh 503 me ja k assign kiya isliye wo reverse me run ho raha hai par inching forward me hota hai reverse me kaise assign karu ?
thanks for your video . I have an ac drive type atv 310 nu 55ne ..when I connect the input voltage the screen write F019 ... when back to maintenance list I find F019 mean GROUND SHORT CIRCUIT ... Although I didn't connect any wire to ground .....what is the reason cause that case ?
one vfd for two motors possible .. if u have 1kw motor 2nos in drc menu asy motor parameters is there motor kw need to give 2 kw and the amp also calculate 2 motors values .. and ith value also.
Sir aci avi ka connection bataiye
Thanks for comments
AVI OR ACI ke liya hume AI1 configuration menu (204.0) me jana hoga
Agr hum voltage input Drive me dete h to voltage ke liya do option h
1:0-5Vdc
2:0-10Vdc
Or ACI (Analog input ) ke liya hame 204.0 me 0A select karna hota hai
GENUS CONTROLS thnk u..or bt dono mai se knsa ek hi select kar sakte hai na..
Ha
@Kaleb Reign Instablaster =)
Thanks sir Hindi men video banaya bahot useful hen Allah bless you
thank you for sharing vfd tutorial bro..
Always welcome
Very good top quality
Very nice explain
🙏👍 very nice sir
Nice video sir
Very very nice sirji
Thanks
Sir fire mode on off setting please tell me sir
Sir ,Schneider alv12 me forward & reverse jog ko potaion metor fast karne se fast ho jata hai esko pot se alag karne ka setting batai.
2 motor VFd synchronizing karna hi bina port ka jo on off push batan ho riale push batan se increase ho decrease ho sir please help me with perameter seting videos banye please apke video mujhe bahut aacha laga
Sir
Switch 1 : inch
Switch 2 : run
Switch 3 : stop
3 switch se ye 3 function ek sath nahi hoo paa rhe
Schneider atv310 vfd
Please solve
Solution mile toh reply karna bhai mera bhi inching nahi ho rha
@@meetpitroda8413
Sir ne too reply nahi Kiya
But
I think I got the solution
thank u
Thanks for watching
Lo+ and Lo- kis cheej k liye h sir iske control diagram me...
sir atv310,320 iska torque mode operation pe bhi video baniyae olease
hello sir 2 hp avt310 drive me f015ka error show ho rha hai kya karu
please help me
Nice
Thanks
Sir is ATV 310 drive pa lo+k sath 24v or lo-k sath com nehi short karna sabji motor chal ra ha hai kaya bat hai bolia ga please
External supply aa raha hoga isliye
thanks bro
Welcome
Hello ser jese hm vfd ke rpm jyda 25 tk shai chelta h25 se jyada kerte h to display on of hone legti h koi upae btao serji
Sir schneider 630 modal ka vidoe banaye e sir
Your great your airplane 💯%quiliy
Allen Bradley 523 Ka vedio banao
Sir please ATV320 drive par ek video banaiye
Sir ATV303HU22N4E Drive on nahi ho rahi kaya karu .
Pls tell me how to single phase motor wiring
Bhai ATV630U75n4 dc bus over voltage aa raha hai kaise sahi kare
Lo+ & Lo - kis liye use hi
110 kw 2 motor hi 2 VFd hi Jo model no hi atv 630c11n4 isko synchronizing karna hi on off push batan se with single port se jo speed bade to dono Kam ho to dono sir please ek video banye please
buen video lastima que no le entiendo . aunque ayuda muchisimo
Pot se minimum speed
42.0 se kmm nahi hoo rhi
Koon sa parameter check krna he sir
Please reply
Pahle potentiometer ki wiring check kro
@@Electrical-Automation exact aapki video ki copy ki he wiring
Sir
Koi parameter Syd missing he
IN ATV 12 SERIES WHAT IS THE Parameter for motor brake
Inching(jog) ka direction change kaise karte hai sir please explain ? Mujhe start aur jog dono me reverse direction chahiye. Start ka toh 503 me ja k assign kiya isliye wo reverse me run ho raha hai par inching forward me hota hai reverse me kaise assign karu ?
Jog Frequency negative me dal ke try kro.. May be work kar jaye.. Kyuki maine kbhi try nhi kiya h.. Or na abhi mere pass drive h.
Dear sir
Can you explain for Schneider altivar 71 PLC control wiring and parameters setting. How we perform it bit by bit
What is the use of LO+ and LO-
Sir I am use Delta drive use 5hp drive how to two moters connection daiahgram pleas me
Sir kindly hamaim Treadmill ki DC motor ko VFD k sath chalana hy. Is k bare main ko vedio banain Thanks.
610 drive parameter samjhaye
Sir 24v aour Lo+ koo aour common ke sath me loop lagwane me kiya faida hai
Sir 610 ka batao na
60 ficvsni pe chalana hai to kaya kare
रिवर्स! फॉरवर्ड के लिए कौनसा पैरामीटर डालना पड़ता है?
Shnieder drive reverse forward conection bataiye thoda sir
can i start up the drive without potentiometer by making the reference by keypad???
YES
thanks for your video . I have an ac drive type atv 310 nu 55ne ..when I connect the input voltage the screen write F019 ... when back to maintenance list I find F019 mean GROUND SHORT CIRCUIT ... Although I didn't connect any wire to ground .....what is the reason cause that case ?
Igbt faltu hai..
sir mujay vfd controling k conction ka digeram batay
Kaise control karna h
How to get second speed
Please tell me that how can we control this vfd 320 on Modbus
Kindly tell complete setting on Modbus
What is difference between 401 and 407
Very aregent
2wire con wiring diagram
Rpm settings ke bare me thoda bataiye
Motor ka rpm kaise set karte ye question hai kya
Selctor switch contion kyss kari
Sir sensor ka contion bati pls sir
Hi
How to connect each vfd to ...two motor
one vfd for two motors possible ..
if u have 1kw motor 2nos in drc menu asy motor parameters is there motor kw need to give 2 kw and the amp also calculate 2 motors values .. and ith value also.
Yes
ATV 930 c13n4c
Ki amper satting batao sir
Ll2 not working ,fire comments time
Opf alarm arahai
Drive se motor ke bich ka connection check kro.
please explain any one person in TAMIL
Sir aap ka no.
Pot ka connection galat hai
Troubleshooting ke liye mob.no
Send error
Lo+ &Lo - Kis liye use hi
How to get second speed