Typical failures in three phase electric motor windings

แชร์
ฝัง
  • เผยแพร่เมื่อ 3 ม.ค. 2025

ความคิดเห็น • 25

  • @lancezeran7650
    @lancezeran7650 2 ปีที่แล้ว +2

    As a professional winder I'd like more in-depth explanation of the various failures in this video. I am mostly self-taught but I love your videos. I work for a smaller shop and am more or less in charge of this sort of thing. You've helped a lot so I don't expect much more but any help is better than nothing.

  • @JFirn86Q
    @JFirn86Q ปีที่แล้ว

    Good overview for sure. Props to EASA for releasing such nice photos too.

  • @adambergendorff2702
    @adambergendorff2702 4 หลายเดือนก่อน

    Excellent video, very helpful, this is probably going to be an expensive repair!

  • @ksbs2036
    @ksbs2036 3 ปีที่แล้ว +4

    I really enjoy these videos on motors from an industry expert. I feel like I'm watching "Techmoan - big power edition" :-)

  • @teoscott1
    @teoscott1 8 หลายเดือนก่อน

    excellent presentation!

  • @daic7274
    @daic7274 3 ปีที่แล้ว +1

    Good summary, thank you. Will have a look at the link.

  • @SustainableCraig
    @SustainableCraig 11 หลายเดือนก่อน

    Great video. Thanks for sharing this information.

  • @kuljinderbrar
    @kuljinderbrar 2 ปีที่แล้ว

    very useful information for industrial engineers.

  • @peaceandlove5855
    @peaceandlove5855 3 ปีที่แล้ว +1

    In easa website they say that 1% voltage unbalance may result in 6 to 10% current unbalance. Any references to this information please!
    Thanks for all the work you are giving. I love it

  • @ammardukhan4162
    @ammardukhan4162 ปีที่แล้ว

    It is really helpful!

  • @ganeshganesh-rj7vy
    @ganeshganesh-rj7vy ปีที่แล้ว

    Thanks useful info

  • @Berkeloid0
    @Berkeloid0 ปีที่แล้ว

    Very interesting! I'm surprised they don't put any sort of thermal cutout or fuse on the stator to protect the windings from overheating.

  • @jsharkey1786
    @jsharkey1786 ปีที่แล้ว

    I’ve rebuilt are electric insulation blowers for the last 10 years. For a year now everytime I run 4 at the same time1 of them pops a breaker. I can’t figure out what is causing this. I feel like I’ve replaced all blower components and the electrical that leads up to it.some advise pleaseeeee

  • @OldePhart
    @OldePhart 3 ปีที่แล้ว

    why are the surge failures only showing up on the connection side?

  • @cornishcat11
    @cornishcat11 3 ปีที่แล้ว

    Any chance you could show a really badly damaged motor? It would be nice to see how you recover a basket case. Great videos.

    • @THIRTYSIXRED
      @THIRTYSIXRED 2 ปีที่แล้ว

      I work for an electric motor repair shop. What type of failure would you like to see ?

  • @bobcocampo
    @bobcocampo 3 ปีที่แล้ว

    What is the coreloss of motor per hp

  • @veeramanikanta8466
    @veeramanikanta8466 2 ปีที่แล้ว

    Thank u sir.

  • @JoseAntonio-tt2mb
    @JoseAntonio-tt2mb 3 ปีที่แล้ว

    Muito bom .

  • @terryherrera5252
    @terryherrera5252 2 ปีที่แล้ว

    Show me HOW to rewind them !!! 😔

  • @franzmarvinlimen9747
    @franzmarvinlimen9747 3 ปีที่แล้ว

    what happens when one of three windings is wired in opposite direction?

    • @FletcherMoorland
      @FletcherMoorland  3 ปีที่แล้ว +1

      I'm just trying to figure out your question here. I'm not sure what you mean when you ask 'wired in opposite direction' If the motor leads are wired L1, L3, L2 then the motor will spin in one direction. If it's L1, L2, L3 it will spin in the opposite direction. There is a chance of reversing a coil in the windings if a mistake is made in the connection. If that's what you are asking then the motor will not rotate properly, depending on the number of poles (Speed) it could cog, it could pull higher current on the phase with the fault and eventually it will burn that coil and the motor will fail.

  • @shehjadsalmani6977
    @shehjadsalmani6977 3 ปีที่แล้ว

    Motor Windnig formulas

  • @Mohdrizwan-zd1vj
    @Mohdrizwan-zd1vj ปีที่แล้ว

    Enemild wire not good