  • @bluebulldog_uk
    @bluebulldog_uk  9 หลายเดือนก่อน +5

    Anyone had an install that they have had to put right? Let me know in the comments
    Thanks you all again for your support much appreciated 🙌👍

    • @TW-mp8zx
      @TW-mp8zx 7 หลายเดือนก่อน

      I had one recently where two properties had issues with dripping tun-dish one was the expansion vessel so quick fix the other one had the cold and expansion connection piped the wrong way round.. fair few years old so im surprised that one wasn't picked up before but then again these unvented cylinders seem to slip under the radar..
      Would be good to get a video of you servicing a combination valve.

  • @cputilitysolutions
    @cputilitysolutions 9 หลายเดือนก่อน +5

    Yes mate thanks for the mention! 🙌🏾 It's so frustrating that worcester make a simple task like an aav into a pig of a job! Great video man 👊🏾

    • @bluebulldog_uk
      @bluebulldog_uk  8 หลายเดือนก่อน +1

      No problem mate, saw you had a nightmare with one and it really was an absolute pain you wasn’t lying 😂🙌👍

  • @jimmock
    @jimmock 8 หลายเดือนก่อน +1

    I did exactly the same thing on a unvented recently. They were in the middle of nowhere so I said I’ll do all 3 as prevention is better than the cure. Two other people had been before me. Couldn’t work that one out. Top video mate!

    • @bluebulldog_uk
      @bluebulldog_uk  8 หลายเดือนก่อน +1

      Thanks mate appreciate the support 🙌👍

  • @douglaughton7626
    @douglaughton7626 8 หลายเดือนก่อน +1

    I had a Vaillant in the loft that did the same thing with the condensate pipe. They only got it rectified after the roof leaked when the lead flashing corroded. Soil vent was 2 metres away 😂

  • @TheMaintenancePlumber
    @TheMaintenancePlumber 9 หลายเดือนก่อน +2

    Great tip with the benders I did not know that 😮

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน +1

      Thanks mate, only learnt that one myself about 18 months ago

  • @ArifPolicewala
    @ArifPolicewala 9 หลายเดือนก่อน +1

    Top job Luke. You can’t be too careful. ❤

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน

      Thanks mate 🙌👍

  • @glynstorer3269
    @glynstorer3269 8 หลายเดือนก่อน +1

    I had a chain wrench on mine I couldn’t get the top off gave it up I need to swap it out in the summer

  • @jasonsimpson-ks8un
    @jasonsimpson-ks8un 8 หลายเดือนก่อน +1

    Screwfix use to sell the oring kits they were selling them off about 2 years ago for £1.98 I got 2 as spears

  • @Troublesome22
    @Troublesome22 8 หลายเดือนก่อน +1

    Condense was leaking??

  • @smartboilercompany1983
    @smartboilercompany1983 9 หลายเดือนก่อน +1

    Love that condense 😮😮

  • @thomascoyne157
    @thomascoyne157 8 หลายเดือนก่อน +1

    Good idea putting a bend on the concrete pipe,I’ll be trying that out as I have move that pipe were it can be cleaned and checked this is working, as they original was on the wall that I’m now covered with a bulkhead for my walk-in shower .👍👍👍🏴󠁧󠁢󠁥󠁮󠁧󠁿🏴󠁧󠁢󠁥󠁮󠁧󠁿 Happy St George’s Day🏴󠁧󠁢󠁥󠁮󠁧󠁿🏴󠁧󠁢󠁥󠁮󠁧󠁿🏴󠁧󠁢󠁥󠁮󠁧󠁿

    • @bluebulldog_uk
      @bluebulldog_uk  8 หลายเดือนก่อน

      Happy at George’s day pal thanks for the support 🙌👍

  • @accesszero4803
    @accesszero4803 9 หลายเดือนก่อน +2

    I've come across junior's were they have left the plug in the expansion hole , so it's never had any expansion

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน

      Seen a few of them on my travels as well 👍

  • @brethren4life152
    @brethren4life152 12 วันที่ผ่านมา +1

    Surely ypu would have been better drilling through the plasterboard into the brick to fix the exp vessel rather than into the plasterboard. Or was it a stud wall?

    • @bluebulldog_uk
      @bluebulldog_uk  9 วันที่ผ่านมา

      Stud wall if I remember correctly

  • @brethren4life152
    @brethren4life152 12 วันที่ผ่านมา +1

    Where do you get yoir combi valves from buddy?

    • @bluebulldog_uk
      @bluebulldog_uk  9 วันที่ผ่านมา

      City plumbing is my main supplier mage

  • @pauljohnston-s3x
    @pauljohnston-s3x 9 หลายเดือนก่อน +1

    Never knew you could use the bender on the condense pipe cheers. I don’t know how these installers get away with such bad work. Another great video 👍

    • @bluebulldog_uk
      @bluebulldog_uk  8 หลายเดือนก่อน

      Thanks mate, yeah when I found out that tip 18 months ago changed the way I do them now 👍

  • @russellbaldry5095
    @russellbaldry5095 9 หลายเดือนก่อน +1

    Ive got almost the exact same job to do. Fernox TF1 filter is leaking from all seals but i found a new/old stock one on ebay for £65. Auto air vent aswell but its a system boiler so that poxy pipe is not in the way😁👍🏼

    • @bluebulldog_uk
      @bluebulldog_uk  8 หลายเดือนก่อน +1

      That pipe is a pain! Glad it isn’t in way for you…fernox TF1 leaking is not a surprise, only have to look at them and they leak 😂👍

  • @russellsmith6476
    @russellsmith6476 9 หลายเดือนก่อน +3

    Personally, i always fit a tundish with a built-in NRV when connecting into a soil pipe

  • @seanosullivan7718
    @seanosullivan7718 7 หลายเดือนก่อน +1

    I always do my best but there is always someone better

  • @andrewoleary9704
    @andrewoleary9704 9 หลายเดือนก่อน +1

    Nice job o that condense mate👍👍

  • @heatpump8566
    @heatpump8566 9 หลายเดือนก่อน +1

    The Aav the lug at the back is so you can put a long screwdriver on it and twist. 2 min job 👍👌

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน

      Il try again next time around, I have used that technique before on other Worcester’s but you can’t get it in the pipework is just ridiculous around

  • @SteveN-pw4dj
    @SteveN-pw4dj 8 หลายเดือนก่อน +1

    Had a plumber friend go to a Worcester last week for a service... Took the case off and got a sudden smell of gas. British Gas serviced it 4 years ago and left the test point open (on the gas valve i think). His question to me was (i am a joiner) why did it not explode?

    • @bluebulldog_uk
      @bluebulldog_uk  8 หลายเดือนก่อน

      Ignition is sealed within burner so no form of ignition and gas has to have correct mix with air to cause an explosion 5-15% if remember right… them lucky thou to be honest

  • @deathstr0kexorn765
    @deathstr0kexorn765 8 หลายเดือนก่อน +1

    BG management love the worcesters! Us engineers hate them! The plastic is crap and just leaks like crazy now

  • @TomChapman-wv9iq
    @TomChapman-wv9iq 9 หลายเดือนก่อน +1

    Nothing like making it easy for you guys lol

  • @TARSoda
    @TARSoda 9 หลายเดือนก่อน +1

    Always take the pump head off - makes it 10x easier to get into the AAV, even on the Greenstar ErP models which are a bit easier.

  • @stephenharris5519
    @stephenharris5519 8 หลายเดือนก่อน +2

    Only hear for the Woosta comments 😂
    Best boilers ever, what’s wrong with you all !
    #yamyam!

    • @bluebulldog_uk
      @bluebulldog_uk  8 หลายเดือนก่อน

      😂 this one is crap design 😂

  • @rossnolan2883
    @rossnolan2883 9 หลายเดือนก่อน +1

    😊😊😊😊😊

  • @charliewillis8527
    @charliewillis8527 8 หลายเดือนก่อน +1

    Yes 40 cdi today 22mm gas looked in book and it says 20 miebar no way did he have that lol

  • @robedwards9658
    @robedwards9658 9 หลายเดือนก่อน +1

    Never mess about with unvented bits always worth replacing as call backs are not a good look.

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน

      Yeah call backs always end up costing in long run

  • @SuperWayneyb
    @SuperWayneyb 8 หลายเดือนก่อน +1

    🤘😎🤘

  • @barry-bradford
    @barry-bradford 9 หลายเดือนก่อน +2

    Worcester is no different than a ferrari everything sharp under the bonnet 🤣🤣🤣

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน

      Rip your hands to shreds sometimes they do

  • @smartboilercompany1983
    @smartboilercompany1983 9 หลายเดือนก่อน +1

    Tbf you could have just used 21.5mm to that stack as its internal.

    • @stepbackandthink
      @stepbackandthink 9 หลายเดือนก่อน +1

      Yup. That was an ugly installation.

    • @smartboilercompany1983
      @smartboilercompany1983 9 หลายเดือนก่อน

      @@stepbackandthink as my dad always used to say, you can’t make a silk purse out of a sows arse lol 😂

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน +1

      I know, stepped back at end and don’t know why I did so much 40mm 😅 always like to come off a stack connection in bigger bore pipe just to stop anything blocking them up

    • @stepbackandthink
      @stepbackandthink 9 หลายเดือนก่อน

      @@bluebulldog_uk Even 32mm would have made more sense.

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน

      @@stepbackandthink if that don’t get boxed in il eat my hat, already said In video and on comment didn’t like the way it looked in end but I always post everything I do good or bad

  • @smartboilercompany1983
    @smartboilercompany1983 9 หลายเดือนก่อน +5

    Worcester boilers really can be a pain, so be of the designers must never have worked on a boiler in there life.

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน +2

      Went up to Worcester and asked them if there repair engineers help design them, apparently not 😂

    • @smartboilercompany1983
      @smartboilercompany1983 9 หลายเดือนก่อน +2

      @@bluebulldog_uk I can imagine, literally changed a main hex on a junior last job today in Aldridge, hex was straightforward but trying to get the electrode connections off was just pain and frustration.

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน +2

      @@smartboilercompany1983 them connections can be an absolute pain sometimes someone suggested long nose spark plug pliers before to help get them off not tried it yet thou

  • @AndyHayward-x2v
    @AndyHayward-x2v 8 หลายเดือนก่อน +1

    Why do engineers continue to recommend Worcesters 🤦‍♂️ horrendous to work

  • @glynstorer3269
    @glynstorer3269 8 หลายเดือนก่อน +1

    Stupid place for auto air vent

  • @stevedevois8452
    @stevedevois8452 9 หลายเดือนก่อน +2

    I hate Worcester boilers almost as much as ideal. They haven’t been designed by a repair engineer.

    • @bluebulldog_uk
      @bluebulldog_uk  9 หลายเดือนก่อน

      Poor design on that AAV and always end up with cuts whenever I repair a Worcester

    • @charliewillis8527
      @charliewillis8527 8 หลายเดือนก่อน

      And black eyes

    • @Pin-2005
      @Pin-2005 8 หลายเดือนก่อน

      Which combi would you recommend, ive been recommended gloworm engery 7. But not too sure about it..

  • @1davestorer
    @1davestorer 8 หลายเดือนก่อน +1

    Mate you look tired in this video.

    • @bluebulldog_uk
      @bluebulldog_uk  8 หลายเดือนก่อน

      Long hours mate, slowing down a bit now so can catch up with myself 👍