Fitting A Space Saving Toilet BUT We've Got A Problem!!

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ก.ย. 2024
  • In this weeks video I show you the full job on how to fit a space saving toilet. We have a problem at the end so watch the full video to see what's happened.
    Lets be have a big push for 7K subscribers so:
    Like
    Comment
    Subscribe
    Don't forget to check up out on Instagram / smartpipeplumbing
    #Plumbing #Plumber #toilet
    Drop any video ideas or if you want to get involved in a video to the following email:
    Info@smartpipeplumbing.co.uk

ความคิดเห็น • 113

  • @SmartPipePlumbing
    @SmartPipePlumbing  ปีที่แล้ว +2

    Don’t forget to smash the LIKE button 👍

  • @stevenyates6732
    @stevenyates6732 ปีที่แล้ว +1

    Non return valves on hot and cold may help? Mini pressure vessel may help? My 2 suggestions.

  • @tomfuge8472
    @tomfuge8472 ปีที่แล้ว +3

    its because its a grab adhesive as well - but yes ive found it not nice to silicone up with profilers either! nice one 👍

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      100% I’ve started using mapie this week and I really like that to be honest

  • @nzxtsnue1139
    @nzxtsnue1139 7 หลายเดือนก่อน +1

    you could just rotate that piece of board and it would fit lol

  • @SuperWayneyb
    @SuperWayneyb ปีที่แล้ว +2

    Mini vessel on the cold feed to the boiler give that sudden shunt on the cold somewhere to go 👍👍

  • @leemarks6622
    @leemarks6622 ปีที่แล้ว +3

    There does not appear to be a shock arrestor fitted to the boiler, with a tap close to the cold inlet of the boiler, could the change in pressure be causing the irractic behaviour, as mentioned dead legs could also cause this but must be removed on conversions.

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      I reckon the shock arrestor and double check valve show sort the problem

  • @thomaswales2157
    @thomaswales2157 ปีที่แล้ว +1

    Is it not that the tap is not fully in the cold position due to the wall been there?

  • @kylestewart698
    @kylestewart698 ปีที่แล้ว +1

    Novopress are defo the best press gun. I was using a 110v Novo press gun 15years ago and have tried the rems and I personally much prefer the Novo. Cants speak on others but all I can say is novopress is a really good.

  • @TW-mp8zx
    @TW-mp8zx ปีที่แล้ว +1

    Theres got to be a large plug of air somewhere on the hot side bit like booster pumps they can intermittently run if there is air in the system. cant imagine water hammer causing this as you cant compress water, will be interested if the shock arrester fixed it though

  • @plumbertime
    @plumbertime ปีที่แล้ว +2

    The water hammer shockwave is passing down the cold in to the boiler and making it fire up.
    Call viesmann ask if there’s a setting to delay the flow sensor/turbine ect a lot of good boilers can fix this in the menus.

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว +1

      Cheers pal didn’t realise you can do that

    • @alexshepherd3308
      @alexshepherd3308 ปีที่แล้ว

      Or a non return valve on cold feed below the boiler and a mini shock arrester between the non return valve and boiler to take the extension. On the Worcester 8000 I fit I have to alter the delay as the guy above mentioned but if boiler can’t do this non return will sort it.

  • @marksavill367
    @marksavill367 ปีที่แล้ว +1

    Ive got the novapress aco103 uses the Milwaukee m12 batterys love it

  • @chrisheywood7671
    @chrisheywood7671 ปีที่แล้ว +1

    there is a dead leg on the hot pipe somewhere in the house .....double check valve after the last tee before the boiler on the cold main , with a mini expansion vessel between the DCV and the boiler

  • @johnabiodun5540
    @johnabiodun5540 ปีที่แล้ว +1

    With the boiler ring Viessmann see if you can put a delay on the flow switch. If not shock arrestor on cold feed to boiler.

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว +1

      Didn’t realise you could do that, thank you I’ll give that a try

  • @The3Y3K0N
    @The3Y3K0N ปีที่แล้ว +8

    The issue with viessmann boiler is the DHW flow sensor being activated by water hammer from either the tap or toilet fill valve closing. To fix this fit a shock arrestor /micro expansion vessel on the cold Inlet to the viessmann boiler. The flow of cold water abruptly hitting the closed valve (either tap or cistern fill) sends an impulse shock wave of water back down the cold pipe work. This shock wave is enough to briefly spin the impellor in the flow sensor in the boiler. The mini expansion vessel dampens /absorbs the shock wave so it doesn't activate the DHW flow switch.
    Regards

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      Thanks pal, gunna give that a try 🙌

    • @martinedwardfleet
      @martinedwardfleet ปีที่แล้ว

      Thanks, my worcester does the same so this will help

    • @plumbertime
      @plumbertime ปีที่แล้ว

      @@SmartPipePlumbing before you do that check with viesmann if there’s a boiler setting where you can change the sensor sensitivity setting! You can on some boilers but I don’t know viesmann

    • @plumbertime
      @plumbertime ปีที่แล้ว

      @@martinedwardfleet what Worcester boiler

    • @alexshepherd3308
      @alexshepherd3308 ปีที่แล้ว

      @@martinedwardfleet what model Worcester is it ?

  • @michaelbolt4530
    @michaelbolt4530 ปีที่แล้ว +1

    That’s an annoying problem right at the end…cool video

  • @Plumbingbob
    @Plumbingbob ปีที่แล้ว +1

    Some jobs can be just a plain ballache mate. Hope you get it all sorted eventually and the tiler gets shot in a firing squad 😂

  • @pb9926
    @pb9926 ปีที่แล้ว +2

    I'm wondering if fitting 2 check valves would cure the issue mate, maybe water shock from the mixer causing the problem

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว +2

      Double check valve and shock arrestor on cold to boiler should sort it I think

    • @MarcGray1990
      @MarcGray1990 ปีที่แล้ว

      Yeah I had this problem with my old boiler…. Turn off cold water in the house or toilet finished flushing and boiler fires up. Shock arrestors on pipe work helped…. Had a new boiler a few years later and problem went away…. Still don’t actually know the exact cause. Could try some double check valves too

    • @MarcGray1990
      @MarcGray1990 ปีที่แล้ว

      Also does it happen if you turn the tap off real slow?

  • @markhoward5780
    @markhoward5780 ปีที่แล้ว +2

    feel your pain once drilled an expensive sink top wrong side for drainer 🙃

  • @mickobyobrien2650
    @mickobyobrien2650 ปีที่แล้ว +1

    Working on a soil pipe with no gloves on😮😂😂😂

  • @darrenmackenzie1892
    @darrenmackenzie1892 ปีที่แล้ว +1

    Really glad to see this done. I bet it's a right C*#£ to fit. Fairplay

  • @andrewoleary9704
    @andrewoleary9704 9 หลายเดือนก่อน

    Shock wrestle on incoming main to boiler should eliminate that mate

  • @killerbean9911
    @killerbean9911 ปีที่แล้ว +1

    WHITE AGAIN? YOU ABSOLUTE MONSTER!
    Sound install mate, I don't like that BT1 either, my go to is dow 785N
    I dunno why they didn't have a small basin installed by the boiler though, there's plenty of space
    But yeah I'd probably go with having some check valves and see if that solves the issue, strange one though

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      Hahah customers choice 😂😂
      I’ve started using mapie silcone pretty impressed to be honest

    • @killerbean9911
      @killerbean9911 ปีที่แล้ว

      @@SmartPipePlumbing mapei silicone is 👌 tbh but Dow is cheaper for white and clear :) then mapei for colour matching (I'm a tiler/bathroom fitter) so colour match is important 🤣

  • @kevinpatchett7094
    @kevinpatchett7094 ปีที่แล้ว +1

    Needs a shock arrestor fitting

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      Think that’s what I’ve gunna go to be honest

    • @kevinpatchett7094
      @kevinpatchett7094 ปีที่แล้ว +2

      Fit a mini one see if it stops it. if not turn cold mains off open hot and cold taps then let a tiny bit of air out the Schrader valve then turn mains back on. Keep doing this till it sorts it.

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      @@kevinpatchett7094 cheers pal

  • @AlexRocks24-7
    @AlexRocks24-7 ปีที่แล้ว +1

    Tap could be mixing 😕

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว +1

      Think it’s sending sock back up the cold and juddering the flow turbine on the boiler

  • @darrenmackenzie1892
    @darrenmackenzie1892 ปีที่แล้ว +1

    Sponsorships from Milwaukee press gun!!! Or a massive discount

  • @tonymurff5234
    @tonymurff5234 ปีที่แล้ว +1

    😎👍👍🤜

  • @chrisb4009
    @chrisb4009 ปีที่แล้ว +1

    I wouldn’t waste your money on a press gun for domestic.
    They’re classed the same as compression fittings so need to be accessible.
    The cost of the fittings offset the time saving

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      Is it actually? Didn’t know that

    • @chrisb4009
      @chrisb4009 ปีที่แล้ว

      @@SmartPipePlumbing Don’t take my word for it, I contacted Pegler and Gebrit and both said the same. I specifically asked about gas but the were non committal about water.
      I’ve got one, it’s occasionally handy.
      They’re good in commercial and where you can’t do hot work.
      MLCP is good snd possibly not classed the same as compression fitting thinking about it.
      You can knock them and they’ll move/leak.

    • @chrisb4009
      @chrisb4009 ปีที่แล้ว

      @@SuperWayneyb I can’t see where it does or doesn’t say you need access?

    • @SuperWayneyb
      @SuperWayneyb ปีที่แล้ว

      I don’t see where you have quoted the reg that says they do

    • @SuperWayneyb
      @SuperWayneyb ปีที่แล้ว

      You wouldn’t use compression under a wooden floor, but press is fine, and it’s good practice to leave a trap wherever there is a fitting regardless of press or soldered. Press is just another method and it’s good to be able to use them all 🤘😎🤘

  • @olympusplumbingheating5027
    @olympusplumbingheating5027 ปีที่แล้ว +1

    It’s because it’s a mixer tap and there is no none return valve on the cold water. So basically your getting a little return from the cold water

  • @olympusplumbingheating5027
    @olympusplumbingheating5027 ปีที่แล้ว +1

    Novopress with M press jaws

  • @steveyboyXRP
    @steveyboyXRP ปีที่แล้ว +1

    rems press gun trust me ive had variuos press guns over the years rems has never failed

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      As it stands it’s definitely between rems and nova press

    • @steveyboyXRP
      @steveyboyXRP ปีที่แล้ว +1

      @@SmartPipePlumbing both solid choices stay clear of rotheburger absolute tripe

  • @chriswatkinson93
    @chriswatkinson93 ปีที่แล้ว +2

    Sounds like the cold might be pushing back down the hot, maybe try a double check valve on the hot feed?

  • @accesszero4803
    @accesszero4803 ปีที่แล้ว +2

    Theres a dead leg on the hot side thats full of air , put a check valve on the cold if u can find it

  • @jsmid
    @jsmid ปีที่แล้ว +1

    I just bought a.bottle of that BT1 havent used it yet, but from what i heard it was brought out because its meant to be easier to profile and work with as CT1 is solid so i think I'll take my bittle baxk and get something else. I was using plumbers gold for awhile but goes yellow to quick

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      Personally think it’s harder to work with than ct1

  • @W1ndy.
    @W1ndy. ปีที่แล้ว +2

    Try added a non return valves to the new toilet/tap feeds

  • @paulhughes8724
    @paulhughes8724 ปีที่แล้ว +1

    Put non return valve on cold and restore air gap on internal shock arrester on boiler if they still have them on that model

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      Cheers pal didn’t realise these had them on the boiler its self I’ll looking in to that

  • @Heatking
    @Heatking ปีที่แล้ว +1

    Great video mate. Never installed on of them toilets before, so was in deep watching 😂

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว +1

      Cheers pal, there not bad to be honest you can get some cheap nasty ones that are a pain

  • @bethaneydunne9682
    @bethaneydunne9682 ปีที่แล้ว +2

    Nightmare glad you got it fixed and sorted 😊😊😊 #feel the pain

  • @galaxydave69
    @galaxydave69 ปีที่แล้ว +1

    I reckon you have a dead leg somewhere normally a old hot supply to a washing machine or similar mate

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      They’ve had a few extensions so wouldn’t surprise me

  • @accesszero4803
    @accesszero4803 ปีที่แล้ว +1

    Ive git a nova press and a rothenberger, i prefer the rothenberger but had to many issues with it to recommend, so id say the nova press

  • @artim4701
    @artim4701 ปีที่แล้ว +1

    Oh, cool toilet! First time i see this. Good job and good luck.

  • @peterdenson7031
    @peterdenson7031 ปีที่แล้ว +1

    Need a check valve on the cold to the boiler. Had a couple of veismann boilers do this the 1st one we had done loads of work in a house and had no idea what was wrong. Check valve on cold to boiler sorted it. Not long after had same issue on a straight swap boiler (also same boiler as you have there) so again fitted check valve and sorted it.

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      Nice one must be something on the boiler I’ll get one fit

    • @andrewoleary9704
      @andrewoleary9704 9 หลายเดือนก่อน

      Not advised mate. Expansion in hot water has nowhere to go. Shock arrest or will take it up

  • @robinholland3894
    @robinholland3894 ปีที่แล้ว +1

    install a shock arrestor

  • @darrenmackenzie1892
    @darrenmackenzie1892 ปีที่แล้ว +1

    Maybe faulty tap...

  • @Setinmywaysalways
    @Setinmywaysalways ปีที่แล้ว +1

    That was a neat idea.

  • @brendanfisher2528
    @brendanfisher2528 ปีที่แล้ว +1

    There is a dead leg somewhere...

    • @brendanfisher2528
      @brendanfisher2528 ปีที่แล้ว +1

      Have they have a boiler conversion at all? It can't be anything you have done it will be an exsisting problem....

    • @SmartPipePlumbing
      @SmartPipePlumbing  ปีที่แล้ว

      Definitely an existing problem as I ran the cold on the bath and it did it too