How to purge bleed air out the HVAC hoses of gauges on mini split

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ต.ค. 2024
  • New 470a refrigerant that replaces 410a refrigerant, with Do-It-Yourself kit included..... ebay.us/tVSqEv
    1 ton, cool only with Wifi & Alexa..... amzn.to/3zlsaxz
    3/4 ton heat pump............... amzn.to/2Js0uLQ
    3/4 ton heat pump w/16 ft kit..... amzn.to/43Mdgwo
    1 TON, 17 seer....... amzn.to/2JrDGvE
    Senville 3/4 ton... amzn.to/2UiJhc5
    The affordable HVAC gauges..... amzn.to/31nTA1Y
    Senville Mini Split 3/4 ton... amzn.to/2UiJhc5
    Adapter for mini split (5/16 to 1/4)... amzn.to/2Ys9qLN
    2 stage vacuum pump..... amzn.to/2JWdeM4
    Mini split Air cond, 110v under $400….. ebay.us/jyUE9P
    Mini split Heat pump, 110v under 385.... ebay.us/ez2AWh
    Pad for outdoor... amzn.to/2EMd9Iy
    Refrigerant line protector kit... amzn.to/2Um1DZI
    Power cord.............. amzn.to/2XrPgQI
    Discount one year of Amazon Prime... amzn.to/2qz0RPa
    Kit to add outside plug..... amzn.to/2Y73aVE
    Nylog blue sealer on flare ends.... amzn.to/33iYLkS
    Or, use this gasket kit for flare connection... amzn.to/36LzxPa
    Alternate tankless water heater models CHEAP!... ebay.us/B1ssST
    Links below also provide some more money saving tips........
    Amazon Prime for just $5.99 a month.... amzn.to/2A7emb8 (Must be on Medicaid, or EBT food stamps)
    Best TMO plan $$$ can buy w/promo code attached…. bit.ly/2RgE44u
    Or, network plans as low as $5 a month…………… bit.ly/2uhGAzC
    Best place to LEGITIMATELY improve your credit score & avoid “credit fix” & “credit repair” scams….. bit.ly/3c3Gw7S
    Free tax preparation for individuals, or 20% of for biz or self-employed….. bit.ly/2w0CU6A
    How I get work and contractor leads to install tankless water heaters Smart home stuff and mini split HVAC systems…. bit.ly/2Vmps4a
    Program to edit your TH-cam videos…. bit.ly/2ZtdTuJ
    How I make my TH-cam thumbnails… bit.ly/2BC12M6
    100% straight forward FREE website builder… bit.ly/2Gq3g5n
    25% OFF new Vanity Phone numbers when you select 2…… bit.ly/2X7bUhl
    Best foam mattress money can buy… bit.ly/2UZEpIK
    Most affordable internet VPN protection… bit.ly/2TPRhkF (use promo code HALFOFF4LIFE and get 50% off for life!)
    Save 75% on shipping……. bit.ly/2Sj1yHL
    Save On printer ink.... • Save Money on Ink cart...
    Oneplus…… www.oneplus.co...
    SUBSCRIBE to our channel… / savegreenhere
    Follow on Twitter… / savegreenhere1
    How to purge bleed air out the HVAC hoses of gauges on mini split
    When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network and Amazon.com

ความคิดเห็น • 70

  • @Jhpc399
    @Jhpc399 3 หลายเดือนก่อน

    Just to say Thank you for this video (which you made with Love). Watching while waiting for my pump / manifold to arrive from China... I am going to move two ACs from my old house to the new. I install them by myself, because I can afford to do it right and not pay someone for NOT use NYLOG, not to use torque wrench, or not to use a vacuum pump to empty and fill properly. But what he is probably good at, is to charge BIG ££s. Also subscribed.

    • @SaveGreenHere
      @SaveGreenHere  3 หลายเดือนก่อน

      Glad I could help! And thanks for subscribing!

  • @josiff1
    @josiff1 11 หลายเดือนก่อน

    Perfect and explained in layman's terms. thank you.

    • @SaveGreenHere
      @SaveGreenHere  11 หลายเดือนก่อน

      Glad you liked it

  • @guestguide2544
    @guestguide2544 2 หลายเดือนก่อน +1

    Nice video, lot of people need this info, seems this would also apply to a small low side single gauge set-up but you would do it at the connection to the can loosening hose connection at the refrigerant can with the can valve shut so the system low side refrigerant would blow and purge the line. Would seem it would work as long as there is refrigerant in the system. But I wonder if there might be a one way type valve in the short single gauge charge line that might keep the gas from coming back past the gauge to blow/purge the line at the loosened can connection?

  • @planetwally
    @planetwally 3 ปีที่แล้ว

    Very informative and clear video - thank you! - is there any serious harm if you forget to purge the hose one time when refilling? I completely forgot to purge when refilling my unit today and immediately realized when it was too late and i opened the valve to feed refrigerant :/

  • @billyhsat
    @billyhsat 2 ปีที่แล้ว +2

    Thanks for sharing, however wouldn't it be better to have your gauge nut tight, and I guess really all nuts tight, when you connect to the a/c unit and then slowly open gauge nut, evacuate line, and then tighten it immediately? It doesn't seem you'd want it loose initially because you'd lose more refrigerant than you might have to.

  • @jacksonjamesphiri1819
    @jacksonjamesphiri1819 ปีที่แล้ว +2

    That was very informative... Thank you

  • @g.king.
    @g.king. 4 หลายเดือนก่อน +1

    good stuff easy but needed a refresh

    • @SaveGreenHere
      @SaveGreenHere  4 หลายเดือนก่อน

      Awesome!
      Before starting, no hoses should be connected to your gauge set and both valves on the gauge set should be closed.
      1. Connect blue hose to low side of manifold gauge set. (amzn.to/3wSNpIA)
      2. Connect blue hose with adapter to mini split. (amzn.to/3X461jc)
      3. Open low side manifold valve slightly. Refrigerant will bleed through manifold and out the middle port while you do this.
      4. Close low side manifold valve. You have just purged air out of the blue hose and low side of manifold.
      5. Connect yellow hose to refrigerant cylinder and manifold. DO NOT OPEN CYLINDER VALVE.
      6. Connect vacuum pump to high side of manifold. (This dual stage 1/2 HP is perfect for mini splits.... amzn.to/3VfHPsU)
      7. Open ONLY the high side manifold valve.
      8. Turn on your vacuum pump. You are now evacuating air from your cylinder hose and the rest of your manifold. It doesn’t take long.
      9. Close high side manifold valve.
      10. Turn off the vacuum pump. You are now free to open the low side manifold valve and cylinder valve to add refrigerant per instructions for recharging the system.

  • @JjMn1000
    @JjMn1000 2 ปีที่แล้ว +1

    The unit can be on when purging your hoses unless it is a negative pressure chiller.

  • @markyakubovsky3380
    @markyakubovsky3380 3 หลายเดือนก่อน +1

    Rookie question here- Is it a clear difference between air bleeding out and refrigerant? Will it be a Captain Obvious moment on when the purge is complete and it's time to close it off?? I am going to be using a manifold set on a car ac, but I am thinking the bleeding principles are the same- Right?? Many Thx!

  • @RahulTelavane-v1m
    @RahulTelavane-v1m 4 หลายเดือนก่อน +2

    What is difference between purging and vaccuming in regard to installation of Air Con?

    • @archer9732
      @archer9732 4 หลายเดือนก่อน +1

      Purging is using refrigerant to push the air out of the charge hoses. The refrigerant replaces the air. Vacuuming is evacuating all air & refrigerant out of the system leaving a total vacuum.

  • @LichaelMewis
    @LichaelMewis 2 ปีที่แล้ว +8

    How can I purge air that mistakenly got into the system from not purging the refrigerant line to begin with?

    • @Snorkle411
      @Snorkle411 ปีที่แล้ว

      Did anyone get an answer on this?

    • @davemccage7918
      @davemccage7918 ปีที่แล้ว +1

      @@Snorkle411you’re going to have to pull a vacuum on the entire system. Harbor freight has (relatively) cheap AC vacuum pumps. About $125-$150

    • @JrIza_914
      @JrIza_914 ปีที่แล้ว

      Probably have to evacuate the system again

    • @archer9732
      @archer9732 4 หลายเดือนก่อน +1

      As I understand it, a Section 608 certified technician will have to recover the mixed refrigerant and recharge the system. The mixed refrigerant will be taken to a certified reclamation center. They will either reject it or charge you for processing it. They will reclaim it if they can or destroy it, both very costly processes.

  • @returnoftheremnant
    @returnoftheremnant 3 ปีที่แล้ว

    thanks for the video...I plan on installing two of these and this will pay for itself instead of contracting an electrician or HVAC person to finalize the installation

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว

      Awesome. Best wishes on the install!

  • @CarlosDelaoGunEngraver
    @CarlosDelaoGunEngraver 2 หลายเดือนก่อน

    thanks for this but how 1. do you use the same gauges to pump down the mini split, and 2 how do you purge the line so that after it pumps down you dont get any air back into the minisplit, ive seen so many videos and no one cleans out the line!

  • @HSMPScience
    @HSMPScience 3 ปีที่แล้ว

    Great job! I hate when cameras don't focus like that.

  • @haipham638
    @haipham638 4 หลายเดือนก่อน +2

    great! Thank you !!!!!!

    • @SaveGreenHere
      @SaveGreenHere  4 หลายเดือนก่อน

      You are welcome!

  • @mikealdano9681
    @mikealdano9681 ปีที่แล้ว

    This is a great chanel very complete lots of info..i subscribed thanks

  • @diysolaradventures7894
    @diysolaradventures7894 ปีที่แล้ว +1

    My mini split has very low pressure what does that mean it's not building in either mode very lil no heat or ac the outside units spin slow like it's not building pressure and I have no leaks

  • @Dutch_Pancake
    @Dutch_Pancake 3 ปีที่แล้ว +4

    What about the air inside the valve block?

    • @lassiterdominguez2879
      @lassiterdominguez2879 2 ปีที่แล้ว +1

      I agree w your question. I was thinking before i looked this subject up. To connect the low side up to the ac system then open up the low side valve till you hear some come out the yellow charge hose. Then close low side valve. Sure ur losing a little freon here but if ur going to recharge anyway its ok. Then you connect your yellow charge hose to your freon can, turn can upside down and open the your high side till you hear or see some come out the high side hose then close it. This should take care of the block you mentioned. Now when you open lowside to charge there should not be any air or contaminant in neither your block or hoses. What have you discovered since you posted your comment?
      I suppose a variation of not turning the can upside down may also work to avoid liquid but idk.

  • @diysolaradventures7894
    @diysolaradventures7894 ปีที่แล้ว +1

    What if you suspect air in your lines while it's running & it's not getting hot or cold & compressor barely running

  • @frankornelaz8234
    @frankornelaz8234 2 ปีที่แล้ว

    Your my hero. Thanks for sharing

  • @knightsgallop
    @knightsgallop 3 ปีที่แล้ว +1

    Why not connect a t valve on the tank end of the yellow hose and purge the blue AND yellow all the way trough the manifold.......

  • @SaveGreenHere
    @SaveGreenHere  ปีที่แล้ว

    New 470a refrigerant that replaces 410a refrigerant, with Do-It-Yourself kit included..... ebay.us/tVSqEv

  • @gravybags7965
    @gravybags7965 3 ปีที่แล้ว

    Thanks for the info!

  • @dannyhampton711
    @dannyhampton711 3 ปีที่แล้ว

    Where do you get those valve attachments for automobile? And thanks for the video!!

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว

      Your welcome. These are the automotive ones. They are a bit cheaper..... amzn.to/2RA3gqe

  • @diysolaradventures7894
    @diysolaradventures7894 ปีที่แล้ว

    How do u build the back up in them

  • @stevenroby5393
    @stevenroby5393 2 ปีที่แล้ว +1

    👍thank you

  • @AEMBowers
    @AEMBowers 3 ปีที่แล้ว

    Hi There. Thank you so much for these videos! I have been watching all of the videos you've generously put together for those DIYers like myself out there. I couldn't afford to put in and maintain a mini split if I had to pay pros. I do have one question that I can't seem to find an answer to (it seems that the entire industry conspires to withhold information from us DIYers). The mini split I intend to order (LG 12k BTU 115 V) comes pre-charged for 25-foot lines. According to the manual 0.22 oz of refrigerant must be added per foot of length beyond 25 feet. It also indicates that the minimum line length is 10 feet. However, it does not indicate whether 0.22 oz of refrigerant must be removed per foot of line length less than 25 feet. I hope to use a 15-foot line length, and would like to know if I must remove some refrigerant (0.22 ozx10 ft = 2.2 oz must be removed, I assume?). Thanks again for your awesome videos!!!

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว

      I would not remove any refrigerant until you have your lines connected, and sealed with Nylog and once you run your unit, check the pressures. The label on the unit would give you the specs. You can also use a refrigerant scale to know EXACTLY how much refrigerant you are adding/removing and this ensures no errors. Here is a scale for $60..... amzn.to/2UUrFoP On the LG unit, what pricing are you seeing? For example, this particular one comes with all the install materials needed, and it's the best pricing I have seen..... ebay.to/378ukRP The Senville units are also very good, and their support is fantastic, from our experience. This 19 SEER Senville 110v heat pump is now on sale...... amzn.to/3nNhiQ4

    • @AEMBowers
      @AEMBowers 3 ปีที่แล้ว

      @@SaveGreenHere Ok. Got it! I guess that in order to use such a scale, should I end up needing it, I'd have to set up a leveled table at location in order to get an accurate reading. Regarding pricing, I'm seeing the LG unit for around $840 right now. The only accessories it appears to be missing relative to the one you linked are the lines (~$100 value) and the power leads between the external/internal units (probably ~$20) (I plan to make my own wall sleeve). My thoughts are that a self-install would likely void warranty; so, I don't mind paying a bit more for a name-brand system that I assume might be more reliable and more serviceable in the future. Thank you!

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว

      Looks like the pricing you got would be 840+100+20=$960. The link I sent you above has the LG unit at $778 with all the copper lines and wiring ( ebay.to/33cKZCz ) Yes, on the scale, just make sure it's leveled, and reset, and or calibrated. You can always also get a lineset cover for 8 feet for under $25 like this one.... amzn.to/372hcxv

    • @AEMBowers
      @AEMBowers 3 ปีที่แล้ว

      @@SaveGreenHere Hmmm ... The webpage that you linked to is for a YMGI unit. I see under the specs that it states: "compressor manufacturer: LG". Are you implying that the YMGI unit, since its compressor is manufactured by LG, is essentially equal in quality/reliability/serviceability to the LG I mentioned? ... www.ecomfort.com/LG-LS120HXV2/p99989.html?gclid=CjwKCAiAtej9BRAvEiwA0UAWXoO1wvfkYs5tmRW70bVyZv8A1Ni-gIuTENhdXayeVj4-C37ladTc5BoC8IQQAvD_BwE

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว

      Absolutely. The compressor is the life and soul of the unit. The other components, like PC boards can fail at any moment, on any system. Recently had one fail on a Senville unit, and it was mailed out immediately after their friendly support asked a few questions. But the compressor is important, and from my understanding, LG is making a large chunk of them, and so it Mitsubishi for mini splits. Best wishes on the new purchase!

  • @alfredoandroid357
    @alfredoandroid357 3 ปีที่แล้ว

    Thank you sir

  • @pierre606
    @pierre606 ปีที่แล้ว

    isnt there air left in the blue manifold, so that when you charge from the yellow input it goes through the blue manifold and then into the blue input line?

    • @SaveGreenHere
      @SaveGreenHere  ปีที่แล้ว

      You need to vacuum the system first. The manifold is to be closed until you add the refrigerant.

    • @UGotAPerdyMouf
      @UGotAPerdyMouf 3 หลายเดือนก่อน +1

      @@SaveGreenHerewhat about the air above the yellow hose in the manifold?

  • @letsfixitdiy648
    @letsfixitdiy648 3 ปีที่แล้ว

    what is the effect in my aircon system unit if i forgot to purge guage hose prior to adding refrigenrant?

    • @SaveGreenHere
      @SaveGreenHere  3 ปีที่แล้ว

      Air in the lines

    • @planetwally
      @planetwally 3 ปีที่แล้ว

      @@SaveGreenHere will one time forgetting to purge cause any issues?

  • @heatpump8566
    @heatpump8566 5 หลายเดือนก่อน

    I vac the hoses quickly.

    • @SaveGreenHere
      @SaveGreenHere  5 หลายเดือนก่อน

      Yes purging is important.

  • @JoelAlexandre-ky6vs
    @JoelAlexandre-ky6vs 5 หลายเดือนก่อน

    Got it

  • @joaquinsuarez6090
    @joaquinsuarez6090 2 ปีที่แล้ว

    I connected pump and oppened blue gauge, left it running for over 15 minutes and nothing happens. No vacuming anything.
    What can it be wrong. Please advise asap anybody.

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว +1

      Was the unit running? Needs to be running to create a suction.

    • @cwills75
      @cwills75 2 ปีที่แล้ว

      ​@@SaveGreenHere This is very confusing, the video specifically says "PLEASE ENSURE HVAC EQUIPMENT IS NOT RUNNING DURING THIS PURGING! OTHERWISE, AIR WILL GET SUCKED IN THROUGH THE SUCTION LINE AND GET INTO THE HVAC SYSTEM." Should a mini split be running or not when purging air through the blue line?

    • @SaveGreenHere
      @SaveGreenHere  2 ปีที่แล้ว +3

      Not running, as mentioned when getting the air out. When adding refrigerant AFTER purging, unit should be running.

    • @eduardotroncoso3444
      @eduardotroncoso3444 ปีที่แล้ว

      Video is really clear and understandable. Nothing wrong. Thank you Master👏🏻👏🏻👏🏻

  • @vegan_cocks
    @vegan_cocks ปีที่แล้ว

    has anyone tried this?

  • @guestguide2544
    @guestguide2544 2 หลายเดือนก่อน

    Nice video, lot of people need this info, seems this would also apply to a small low side single gauge set-up but you would do it at the connection to the can loosening hose connection at the refrigerant can with the can valve shut so the system low side refrigerant would blow and purge the line. Would seem it would work as long as there is refrigerant in the system. But I wonder if there might be a one way type valve in the short single gauge charge line that might keep the gas from coming back past the gauge to blow/purge the line at the loosened can connection?