Depth of Electrical Earthing (urdu , Hindi)

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 เม.ย. 2021
  • Unicorn Energy Systems is a professional company in Lahore which provide following Services. Contact/WhatsApp 0335-4946498
    1: Solar PV system Installation
    2: Electrical Earthing Design and Services
    3: Power DB panels
    4: Pressure Pumps with VFDs
    3: Lightning Arrestor System Design and Installation Services, Surge Protectors
    4: Manufacturer/ Supplier of Earthing Chemical, Super Earthing GEL, Bentonite Earthing Chemical
    5: Earthing Equipments/ Material, Earthing Electrodes
    6: Electrical System Inspection Services
    7: Solar Panels and Electrical System Thermal Imaging Inspection
    8: Energy Audits
    9: Soil resistivity test/ Electrical Earthing Tests
    Contact/WhatsApp 0335-4946498
    www.unicornenergysystems.com
    #solar #earthing #lightning_arrestor #Solar_energy #solar_panles #electrical_earthing #electrical_grounding #bentonite_earthing #fawad_baig
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 78

  • @AgroEngineer
    @AgroEngineer หลายเดือนก่อน +1

    Main bhi Kafi pareshan tha depth k bare lekin aj tasalli ho gai hy thanks sir saty blessed

  • @arslanshakoor11
    @arslanshakoor11 28 วันที่ผ่านมา

    Gypsum is poured because it has the ability to absorb moisture from soil to reduce the resistivity of soil. Depth is necessary to reach a water. reservoir to keep the earth moist

  • @ahmadkhalid2547
    @ahmadkhalid2547 2 หลายเดือนก่อน +1

    very informative video.

  • @MuhammadIqbal-hl6mx
    @MuhammadIqbal-hl6mx 2 ปีที่แล้ว +1

    Great, thanks 👍
    from Karachi

  • @mumtazawan9458
    @mumtazawan9458 หลายเดือนก่อน

    Very informative 👍

  • @ishfaqahmad9001
    @ishfaqahmad9001 หลายเดือนก่อน

    Informative video

  • @shahidfarooq2070
    @shahidfarooq2070 3 หลายเดือนก่อน

    Excellent Knowledge 👍

  • @causelistbranchdsjmardan614
    @causelistbranchdsjmardan614 หลายเดือนก่อน

    good information about earthing❤

  • @gulahmed6875
    @gulahmed6875 3 หลายเดือนก่อน +1

    Well explained ❤

  • @embeddedzone
    @embeddedzone ปีที่แล้ว +2

    Very good sir,
    Appreciate🙏....
    Best wishes from India🇮🇳🇮🇳

  • @JawadKhan-et4rc
    @JawadKhan-et4rc ปีที่แล้ว +3

    Very good

  • @techchat370
    @techchat370 4 หลายเดือนก่อน

    bhai ghar main khuwan well hai and depth 26 feet hai and base main geeli matti agar main us main copper rod dal loin to kam chal jai ga? us kuwahin sya hum pani bhi use kartay hain trough plastic pipe through motor

  • @aqbaig0174
    @aqbaig0174 4 หลายเดือนก่อน +1

  • @tayyabimranmahatir
    @tayyabimranmahatir 29 วันที่ผ่านมา

    Bijli ke earthing kis liye ke jati?iska kia maqsad hota hai electrical earthing ka?

  • @faisalrazzaq5725
    @faisalrazzaq5725 3 หลายเดือนก่อน

    sir district sahiwal me kitny feet bore hona chshiye for earthing

  • @wajidmalik4725
    @wajidmalik4725 11 หลายเดือนก่อน +2

    Thanks for information
    If you spread more knowledge,you will be rewarded more.plesse mention your name and qualifications

    • @unicornenergysystems
      @unicornenergysystems  11 หลายเดือนก่อน

      Jazak Allah
      I am Fawad Baig, i am Electrical Engineer and experience in electrical earthing system design

  • @HADI10764
    @HADI10764 2 หลายเดือนก่อน

    Brother Lahore kya charges le rahe hain aap for Solar System Earthing.

  • @tabassamtabassam1669
    @tabassamtabassam1669 3 ปีที่แล้ว +3

    Hello sir in Sialkot you can provide your service for earthing and what can be the cost

  • @muhammadrehan69
    @muhammadrehan69 5 หลายเดือนก่อน +1

    Earth jaga kee pillars men Laga sakty hen

  • @taimoorshah8230
    @taimoorshah8230 7 หลายเดือนก่อน +1

    agar app ne earth apne garden mai lagana hai to 10 foot ki rod zameen mai thok dou app ka earth lag jaye ga kyun k app apne garden ko wese bhi pani daite rethe ho to app ko 20 foot ka bore karne ki koi zaruat nahi.

    • @unicornenergysystems
      @unicornenergysystems  6 หลายเดือนก่อน

      Esy Earth theek kam nhi kary ga. Earth k liye pani sirf in 20% tak ehm hy. Baki 80 % or cheezen important hen

  • @atiqrahmanlodhi4709
    @atiqrahmanlodhi4709 ปีที่แล้ว +1

    agr zamein k upper upper hi rakh dein tu eath ho jay ga

  • @qaisershehzad
    @qaisershehzad 3 ปีที่แล้ว +3

    Pl review your statement reg rod length & diameter. As resistance increases with the increase of length while decreases with the increase of diameter.
    Hence lengthy conductor/rod reduces the current flow while larger dia of conductor/rod increases current flow...

    • @unicornenergysystems
      @unicornenergysystems  3 ปีที่แล้ว +1

      Electrical Earthing Resistance is different than conductor resistance.
      You are correct in term of conductor resistance.
      But in case of electrical earthing Resistance decrease by 40% as length gets double

    • @unicornenergysystems
      @unicornenergysystems  3 ปีที่แล้ว +1

      Think in terms of contact area of conductor and earth soil. As length doubles contact area doubles and hence decrease in contact resistance.

    • @qaisershehzad
      @qaisershehzad 3 ปีที่แล้ว

      @@unicornenergysystems yes if earth strip or bare conductor touches the soil it becomes earth but what about diameter???

    • @qaisershehzad
      @qaisershehzad 3 ปีที่แล้ว

      Actually it depends upon Followings:::
      Type of soil.
      Clay, sand, clay with sand mix etc
      Clay has 40, sand has 2000, clay & sand mix has 100 soil resistivity. U ve to dig till achieving the type of soil that has low value of resistivity.
      Soil resistivity reduces by...
      Soil moisture means wet soil.
      Depth of soil.
      Adding salt contents ( copper/magnesium sulphate or sodium chloride.

    • @qaisershehzad
      @qaisershehzad 3 ปีที่แล้ว +1

      If you use copper earthing conductor of 35mm2 it has 0.55ohm/ km whereas if u use 50mm2 it had 0.39ohm/km.
      Earthing conductor may of bare/strip/rod.

  • @mohammaduzair88
    @mohammaduzair88 ปีที่แล้ว +1

    Mera pc buhat earth marta ha kia m wall me keel thok k ground kr sakta ho?

    • @zohaibijaz1906
      @zohaibijaz1906 ปีที่แล้ว

      😂

    • @ZookLife
      @ZookLife 11 หลายเดือนก่อน

      Chapal pehan kar istemaal karain

    • @unicornenergysystems
      @unicornenergysystems  6 หลายเดือนก่อน

      Behtar hy theek Earth karen
      Aarzi tor pe ap keel lga sakty hen

  • @ahmedbilal8837
    @ahmedbilal8837 2 หลายเดือนก่อน +1

    Sir fsd ma raad or boring kitna hona chaye

  • @raheelahmed9206
    @raheelahmed9206 6 หลายเดือนก่อน +1

    Sir earth ki capacity kya hona chaia

    • @unicornenergysystems
      @unicornenergysystems  6 หลายเดือนก่อน +1

      Apna swal company number pe detail me bhejen

  • @malikgulshan3271
    @malikgulshan3271 2 ปีที่แล้ว +2

    آواز بہت کم ہے

    • @imac786
      @imac786 ปีที่แล้ว +1

      Sounds fine on my phone. Check your speaker

  • @fahadshaikh865
    @fahadshaikh865 2 ปีที่แล้ว +1

    Buhat lambi kardi.ya bhe tu batao karna kiya ha bhai...

  • @blackmouse2248
    @blackmouse2248 3 ปีที่แล้ว +5

    How to verify home earthing?

    • @unicornenergysystems
      @unicornenergysystems  3 ปีที่แล้ว +1

      You can verify earthing with earth testing meter. But usage of earth testing meter is complex and only trained person can use it

    • @qaisershehzad
      @qaisershehzad 3 ปีที่แล้ว

      If your earth resistance is lower than 3 Ohm or 5 Ohm to some extent, it means your earthing is good. Value can be measured by earth resistance meter. My opinion, it should be less than 3 Ohm for power earthing.

    • @unicornenergysystems
      @unicornenergysystems  3 ปีที่แล้ว +1

      @@qaisershehzad it is not matter of opinion. International standards are made after multiple industrial and environmental testing effects.
      One person opinion doesn't matter.
      Value of resistance is important. And lower value is mostly required according to reason of earthing.
      In some applications high resistance earthing is recommended.
      Unless you get reading of Electrical Earthing science and engineering point of views of NEC and IEEE, you will confuse electrical engineering formulas and concept with this different science.

    • @qaisershehzad
      @qaisershehzad 3 ปีที่แล้ว

      @@unicornenergysystems
      Sorry to say...
      Every person has its right to give it's opinion on the basis of his experience & education and exposure. I have IEEE standards. I ve made lot of not only power earthing but also telecom earthing.
      Thanks for replying.... stay blessed

  • @naveedashraf7491
    @naveedashraf7491 8 หลายเดือนก่อน

    sir rahem yar khan main ketne fet pe bor ho

    • @unicornenergysystems
      @unicornenergysystems  8 หลายเดือนก่อน

      Between 10 to 20ft

    • @faisalrazzaq5725
      @faisalrazzaq5725 3 หลายเดือนก่อน

      sir district sahiwal me kitny feet bore hona chahiye for earthing

  • @umararsalan5408
    @umararsalan5408 2 ปีที่แล้ว +2

    sir me ne ELCB lagaya hai apnay ghar par but wo kaam nahi kar raha.
    what you suggest me.

    • @unicornenergysystems
      @unicornenergysystems  2 ปีที่แล้ว

      How do you know k wo kam nhi kar rha. How you tested

    • @umararsalan5408
      @umararsalan5408 2 ปีที่แล้ว

      @@unicornenergysystems sir mujhe current laga hai ek dafa Lekin wo trip nahi howa

    • @unicornenergysystems
      @unicornenergysystems  2 ปีที่แล้ว

      Change kar k orignal company ka 30mA ka lagaen

    • @umararsalan5408
      @umararsalan5408 2 ปีที่แล้ว

      @@unicornenergysystems which company suggests you

    • @unicornenergysystems
      @unicornenergysystems  2 ปีที่แล้ว

      @@umararsalan5408 any company is equally good. Just buy forn orignal dealer

  • @ulfatphotostate7081
    @ulfatphotostate7081 4 หลายเดือนก่อน +1

    Pani tak khod dian to ?

    • @unicornenergysystems
      @unicornenergysystems  4 หลายเดือนก่อน

      Chemical ki life kam ho jaey gi

    • @ulfatphotostate7081
      @ulfatphotostate7081 4 หลายเดือนก่อน

      ​@@unicornenergysystems Pani tak lay gy hen 4 foot ka road adha pani mien thak deya adha uper hy 40 foot bad pani nickal copper road k sath copper ke pati means tar use ke sari kia ya earthing standered ho gyee?

  • @iadilehsan
    @iadilehsan วันที่ผ่านมา

    Wrong info about length and diameter. The conductivity is increased two times more in case of diameter as compared to length

    • @unicornenergysystems
      @unicornenergysystems  วันที่ผ่านมา

      Conductor resistance is different thing and earthing resistance ia different things
      At earthing resistance, formula for conductor resistance does not apply

  • @DieselGeneratortraining
    @DieselGeneratortraining ปีที่แล้ว +1

    Jis jis bhai nay diesel generator ki training videos dekhni hai wo power learning channel per aa kar subscribe karlay free offer hain 😄 😀😀😀😀😀