Unicorn Energy Systems
Pakistan
เข้าร่วมเมื่อ 6 ก.ย. 2020
ER Light Arrestor Testing Video
Unicorn Energy Systems
ER Light Arrestor
Zero Earth CEM
Super Earth Gel Powder
Power Earth GEM chemical rod
0335 4946498
ER Light Arrestor
Zero Earth CEM
Super Earth Gel Powder
Power Earth GEM chemical rod
0335 4946498
มุมมอง: 184
วีดีโอ
Distance Between Electrical Earthing
มุมมอง 25927 วันที่ผ่านมา
Unicorn Energy Systems 11am to 6pm 03354946498
AC, DC and Light Arrestor Earthing - Explained in Detail
มุมมอง 7Kหลายเดือนก่อน
Unicorn Energy Systems 11am to 6pm 03354946498
Residential Solar Earthing Priority Detail
มุมมอง 1.3Kหลายเดือนก่อน
Unicorn Energy Systems 11am to 6pm 03354946498
Transform Earthing and Voltage Surge
มุมมอง 5485 หลายเดือนก่อน
0335 4946498 Fawad Baig UNICORN ENERGY SYSTEMS
Electrical Earthing Complete Process - الیکٹریکل ارتھ کا مکمل طریقہ
มุมมอง 28K6 หลายเดือนก่อน
0335 4946498
Lecture on Electrical Earthing Methodology in University of Engineering and Technology UET Lahore
มุมมอง 3057 หลายเดือนก่อน
Marconite Power Earth GEM rod - Using Method
มุมมอง 1.1K9 หลายเดือนก่อน
Electrical Earth Test problems and solutions
มุมมอง 9509 หลายเดือนก่อน
Electrical Earthing 7500KVA transformer and Electric Furnace in Pakistan Railways Workshop
มุมมอง 5049 หลายเดือนก่อน
Solar PV System KW size Calculation - Customer Guide 2
มุมมอง 2829 หลายเดือนก่อน
Earthing in Pakistan Railways
มุมมอง 1519 หลายเดือนก่อน
Hybrid vs ongrid Solar installation - Customer Guide Ep1
มุมมอง 5839 หลายเดือนก่อน
Inverter lgwane k bad meter ki reverse light on ho gayi h nurture common nhi h check krwaya h lekin ek tar lay k inverter k sath laga k erth kiya to light bnd hogi meter ki reverse to mistri keh rha h tar lga k nichy ek pani ki hodi h wha keel lga dety h nami rehgi erth reh ga kiya yeh sahi tarika h
Please guide- Can we share solar pannels earth with DC SPDS? Or any seprate earthing for Spds?
Wrong info about length and diameter. The conductivity is increased two times more in case of diameter as compared to length
Conductor resistance is different thing and earthing resistance ia different things At earthing resistance, formula for conductor resistance does not apply
Inverter k saath aik earth ka connection ha, wahan konsa earth connect krna hota ha?
AC earthing
30A ke lia konc earthig karni chia kia 3 feet ke copper road kam karskti he
زبردست
Thank you for your guidance ❤
grate bro
MashAllah sir kamal aik aik point app bohit ala batya But aik sawal erth boring depth ketni honi chay
کیا ac dc اکٹھا کر سکتے ہیں ؟
Bro ..... my orientation is -9 degree ,,,,, any issue????
Useful, thanks, subscribed
Bhai bore ki gehraai kitmi honi chahiye??? Ya jb nami aa jaye to bore rok denna chahiye??
Sir, AC Earthig, DC Earthing & Lighting Arrester Earthing k liay same materials use hongay? Mean all the three are same and just they r separately connected Or Something else?
Well explained
Good informition
Good luck
Very nice information Sir
The minimum distance between two earthing should be two times the length of the earthing electrode.
Yes technically you are right but in that case electrode must be from bottom to top ground surface And for practical scenario bore must not be above 10ft deep. That further require chemical earthing with mesh design
Gypsum is poured because it has the ability to absorb moisture from soil to reduce the resistivity of soil. Depth is necessary to reach a water. reservoir to keep the earth moist
MA great.
Good
Bijli ke earthing kis liye ke jati?iska kia maqsad hota hai electrical earthing ka?
Chakwal m ap services provide kr skty hain?
سر اے سی ارتھنگ اور ڈی سی ارتھنگ کے لیے اگر زمین میں ایک ہی ارتھ بنائیں تو اس کے کیا نقصانات ہوتے ہیں ؟
Aos sir g bandal of thanks
Very informative 👍
پہلی بار سولر سسٹم پر بات کرتا بندہ کام کا لگا
Lahore main karwana ho to kitna kharcha ajaye ga ?
Good 👍 ❤
Earht esy lgti ho
100 💯 glt earth
MashAllah good info
السلام علیکم سر ایک ارتھ سے دوسرے ارتھ کا کم از کم اور زیادہ سے زیادہ کتنا فاصلہ ہو چاہیے
کم از کم 5 فٹ. زیادہ جتنا مرضی
Very very Informative ,
Can we connect AC earthing with both DC SPD and AC SPD?
Yes, AC Earthing ko AC SPD, or DC SPD k sath attach kia ja skta hai, ager ap DC SPD Inverter k pas lga rhe hain to AC Earthing se attach krain, ager ap DC SPD structure k pas lga rhe hain to Structure ki earthing se attach krain
Very informative. 👍 Also make video on Type 1, 2 and 3 SPDs and where to use which SPD?
Very good info !👍
Main bhi Kafi pareshan tha depth k bare lekin aj tasalli ho gai hy thanks sir saty blessed
Good working bro keep it up.
Nami ka hona zaruri hota kia
SPD ki erting cable ko konse earth kesath connect karna chahiee...
Informative video
Salt sand and charcoal enough for earthing. I have done many earthing points in cement factory with 1 ohm 1v results..... These all things required for factory ...
Bhai earthing problem ki waja sy fridge trip Hoti hai?
Nice
good information about earthing❤
Always use UL listed Grounding Materials....Costly hota hay...but excellent result...Grounding system ki welding ko Cad welding, thermite welding ya exo thermic welding boltaay hain.
AOA bahi why my unit 521 doesn't show the value and it show zero battery
Thank you for the guidance and support
Most welcome