Quelfire
Quelfire
  • 166
  • 93 845
Update: The QuelSelector V4
❗Update: The QuelSelector V4
V4 is packed with many new standard details, making it bigger and better than ever before, including additional details for:
🔸Single and double-skin walls
🔸Partial penetrations
🔸Rigid walls
🔸Concrete floors
🔸Hollow core slabs
🔸Steel profile decks
🔸Linear joint seals
Based on feedback from our valued customers and clients, we have also made some small modifications to the layout and content in order to improve the user experience.
------------------
Download V4: quelfire.co.uk/quelselector-firestopping-solution-finder-tool/
------------------
The right firestopping system, installed correctly, saves lives. At Quelfire, we have a friendly and honest team that is always willing to help with problems faced by the construction industry. We provide support from planning through design to installation and aim to answer any enquiries within one working day.
BECAUSE IT'S YOUR JOB TO KNOW.
#firesafety #firestopping #update
มุมมอง: 11

วีดีโอ

Should Firestopping Systems Be Installed by Third-Party Accredited Contractors?
มุมมอง 3019 ชั่วโมงที่ผ่านมา
❓Should Firestopping Systems Be Installed by Third-Party Accredited Contractors? While it is not currently required by law for passive fire protection products to be installed by contractors with third-party certification, this has been proven to be a good way to ensure compliant installations by qualified and competent individuals. However, sole reliance on third-party certification for compli...
Burning Questions | EP 22: Fire Testing (Part Two)
มุมมอง 16314 วันที่ผ่านมา
Burning Questions | EP 22: Fire Testing (Part Two) We’re back with another fire testing episode! Darryl Wells, Commercial & Development Director, and Alec Purdie, Technical Manager, explore key topics, from the phase-out of BS 476 to the important role of collaboration. We would love for you to get involved and send in any questions or topics you would like covered in future episodes. And, of c...
Does a Tested Detail for a Higher Fire Rating Also Cover a Lower Rating?
มุมมอง 5321 วันที่ผ่านมา
❓Does a Tested Detail for a Higher Fire Rating Also Cover a Lower Rating? In short, a tested detail for a higher fire rating also covers a lower one. The EI fire rating is located in the table at the bottom left of our standard installation detail drawings. EI ratings are ‘up to’ measurements, meaning that any rating ‘up to’ the one stated in the detail will be covered. For example, a tested de...
What Are Partial Penetrations?
มุมมอง 7528 วันที่ผ่านมา
❓What Are Partial Penetrations? In this short video, Alec Purdie (Technical Manager) explains what a partial penetration is and discusses the tested details we have at Quelfire for this type of application. View our knowledge hub: quelfire.co.uk/knowledge-advice/ The right firestopping system, installed correctly, saves lives. At Quelfire, we have a friendly and honest team that is always willi...
Test Standard Updates: Do Older Standards Get Superseded?
มุมมอง 95หลายเดือนก่อน
❓Test Standard Updates: Do Older Standards Get Superseded? The simple answer is no; when test standards are updated, older standards are still valid but have limitations. Listen to our Technical Manager, Alec Purdie, explain further. Read our knowledge hub article: quelfire.co.uk/knowledge-advice/fire-resistance-test-standard-updates-do-old-standards-get-superseded/ The right firestopping syste...
Can I Have the Test Report?
มุมมอง 125หลายเดือนก่อน
❓Can I Have the Test Report? In this short video, Alec Purdie (Technical Manager) addresses common misconceptions in the industry regarding terminology related to tested solutions, fire test reports, and classification reports. View our knowledge hub piece: quelfire.co.uk/knowledge-advice/what-is-the-difference-between-a-classification-report-and-a-test-report/ The right firestopping system, in...
Burning Questions | EP 21: BECAUSE IT'S YOUR JOB TO KNOW
มุมมอง 179หลายเดือนก่อน
Burning Questions | EP 21: BECAUSE IT'S YOUR JOB TO KNOW In February 2024, Quelfire introduced its new campaign, "BECAUSE IT'S YOUR JOB TO KNOW." In this episode, Sales Director, Craig Wells, dives deeper into the campaign's messaging and addresses some key FAQs. We would love for you to get involved and send in any questions or topics you would like covered in future episodes. And, of course, ...
Pattress vs. Letterbox Installation of QuelStop Fire Batt?
มุมมอง 187หลายเดือนก่อน
❓Pattress vs. Letterbox Installation of QuelStop Fire Batt? QuelStop Fire Batt can be installed in a variety of ways. However, the most common way would be to install it into a formed opening, otherwise known as a ‘letterbox opening’, or a Builders Work in Connection (BWIC) opening. In this video, Adrian Paynter (Business Development Manager) explains more about letterbox openings, while touchi...
Why Does Specific Information Matter?
มุมมอง 712 หลายเดือนก่อน
❓Why Does Specific Information Matter? Picture this. You reach out to a manufacturer for guidance on installing a plastic pipe through a floor. Instead of a clear, concise answer, you're bombarded with an abundance of tested firestopping details. This quantity of information leaves you more uncertain than ever, unsure of the next step. Sound familiar? This video explains the importance of provi...
Firestopping for Small-Diameter Metal and Plastic Pipes: Necessary?
มุมมอง 1592 หลายเดือนก่อน
❓Firestopping for Small-Diameter Metal and Plastic Pipes: Necessary? There is a long-standing myth in the construction industry that plastic pipes with an internal diameter of 40mm or less, and metal pipes with a diameter of 160mm or less, do not need to be firestopped where they penetrate compartment walls and floors. However, with years of fire testing experience, we know that additional serv...
Burning Questions | EP 20: Customer FAQs (Part Five)
มุมมอง 1702 หลายเดือนก่อน
Burning Questions | EP 20: Customer FAQs (Part Five) Got a burning question? In this episode, Adrian Paynter (Business Development Manager) provides insightful answers to commonly asked questions from our valued customers. We would love for you to get involved and send in any questions or topics you would like covered in future episodes. And, of course, if you have any general feedback for Burn...
Can You Mix and Match Products from Different Manufacturers?
มุมมอง 1102 หลายเดือนก่อน
❓Can You Mix and Match Products from Different Manufacturers? “Can I use manufacturer A’s intumescent sealant with manufacturer B’s fire batt?” This is a question we often get asked at Quelfire and the simple answer to it is no. Listen to Adrian Paynter (Business Development Manager) explain why. The right firestopping system, installed correctly, saves lives. At Quelfire, we have a friendly an...
How to Apply QuelStop Ablative Coating to the QuelStop Fire Batt
มุมมอง 5823 หลายเดือนก่อน
❓How to Apply QuelStop Ablative Coating to the QuelStop Fire Batt Ablative coating is primarily used to repair damage or cracks in a fire batt. The coating is applied to these areas to reinstate the fire-resistance performance of the product. In other cases, it can be used as part of a tested firestopping system and applied to individual services where they penetrate compartment lines to assist...
Firestopping Tested Details: Specwall Advanced Wall Systems
มุมมอง 1553 หลายเดือนก่อน
💥 Firestopping Tested Details: Specwall Advanced Wall Systems Quelfire’s products are all independently tested at Warringtonfire, which is a UKAS accredited certification body. A significant proportion of annual investment goes into research and development in order to provide the construction industry with primary test evidence over engineering judgements. Many of our customers will be familia...
Burning Questions | EP 19: Seven Years On from Grenfell - What Has Changed?
มุมมอง 1693 หลายเดือนก่อน
Burning Questions | EP 19: Seven Years On from Grenfell - What Has Changed?
Do Quelfire Offer Engineering Judgements?
มุมมอง 1053 หลายเดือนก่อน
Do Quelfire Offer Engineering Judgements?
Update: Acoustic & Intumescent Putty Pad Classification Report
มุมมอง 1203 หลายเดือนก่อน
Update: Acoustic & Intumescent Putty Pad Classification Report
How We Fire Test Pipework
มุมมอง 814 หลายเดือนก่อน
How We Fire Test Pipework
Update: QF2 Fire Protection Compound Classification Report
มุมมอง 1364 หลายเดือนก่อน
Update: QF2 Fire Protection Compound Classification Report
Burning Questions | EP 18: Exploring Competency with Joe Hewitt
มุมมอง 2724 หลายเดือนก่อน
Burning Questions | EP 18: Exploring Competency with Joe Hewitt
Exhibition: The Fire Safety Event Highlights 2024
มุมมอง 844 หลายเดือนก่อน
Exhibition: The Fire Safety Event Highlights 2024
FAQs: Service Penetration Sealing Through Specwall
มุมมอง 1875 หลายเดือนก่อน
FAQs: Service Penetration Sealing Through Specwall
Firestopping Tested Detail: Substations or Basements (Cable Penetrating a Rigid Wall)
มุมมอง 1615 หลายเดือนก่อน
Firestopping Tested Detail: Substations or Basements (Cable Penetrating a Rigid Wall)
Burning Questions | EP 17: Exploring Competency with Hassan Ahmed
มุมมอง 3045 หลายเดือนก่อน
Burning Questions | EP 17: Exploring Competency with Hassan Ahmed
MEP Considerations - Part Two
มุมมอง 2875 หลายเดือนก่อน
MEP Considerations - Part Two
How We Fire Test Cables and Cable Carriers
มุมมอง 1276 หลายเดือนก่อน
How We Fire Test Cables and Cable Carriers
What Is an Annulus?
มุมมอง 1946 หลายเดือนก่อน
What Is an Annulus?
Burning Questions | EP 16: Exploring Competency with Mandy Youssef
มุมมอง 2256 หลายเดือนก่อน
Burning Questions | EP 16: Exploring Competency with Mandy Youssef
MEP Considerations - Part One
มุมมอง 4696 หลายเดือนก่อน
MEP Considerations - Part One

ความคิดเห็น

  • @surya2089
    @surya2089 4 วันที่ผ่านมา

    After placing this can we change remove this sealant ?

  • @marioeze3667
    @marioeze3667 8 วันที่ผ่านมา

    How can I get trained by your company?

    • @FirestoppingSolutions
      @FirestoppingSolutions 3 วันที่ผ่านมา

      Hello, if you could email in at training@quelfire.co.uk and the team will pick this up. Many thanks.

  • @HassanAhmed-pu4wd
    @HassanAhmed-pu4wd หลายเดือนก่อน

    Yet another great episode!

  • @waynebarrow7260
    @waynebarrow7260 หลายเดือนก่อน

    I deeply appreciate your focus on early engagement in firestopping, how strongly you have carried the skills, competency & behaviors message forward, and the "Because it's your job" campaign. Well done to you all!

  • @alexorza83
    @alexorza83 2 หลายเดือนก่อน

    WELL DONE GUYS

  • @davidbathe4108
    @davidbathe4108 2 หลายเดือนก่อน

    Thank you These videos are so useful

  • @davidbathe4108
    @davidbathe4108 2 หลายเดือนก่อน

    Brilliant Hassan does really have a clear compass on his development with in other industries

    • @davidbathe4108
      @davidbathe4108 หลายเดือนก่อน

      I really do need to speak to one of your team for guidance with in the industry

  • @davidbathe4108
    @davidbathe4108 2 หลายเดือนก่อน

    That was brilliant gents Thank you I was glued to your conversation My role with in my company has changed and I am getting more and more involved with the fire stopping side of the company I have so much more to learn and tbh don’t feel confident speaking about what we are installing Could I contact either of you guys directly Many thanks

    • @FirestoppingSolutions
      @FirestoppingSolutions 2 หลายเดือนก่อน

      Hi David - thanks for your feedback. Certainly, we'd be more than happy to help. If you could contact us at technical@quelfire.co.uk.

    • @davidbathe4108
      @davidbathe4108 2 หลายเดือนก่อน

      @@FirestoppingSolutions do you have a e mail that I can contact someone on

  • @tonyprice3944
    @tonyprice3944 3 หลายเดือนก่อน

    What fixings are you using … we have to use 8mm mushrooms when fixing to concrete … fire rated screws would defo save my arm from hammering in mushrooms all day

    • @FirestoppingSolutions
      @FirestoppingSolutions 2 หลายเดือนก่อน

      Hi Tony, thanks for your question. Please refer to pages 4, 5, 6, & 7 of detail QB-CF150-P-06: quelfire.co.uk/wp-content/uploads/QB-CF150-D-06-Plastic-pipe-penetrating-a-rigid-floor-QuelCoil.pdf.

  • @shyabudheensurur1127
    @shyabudheensurur1127 3 หลายเดือนก่อน

    Is ter any vacancy for ti's job

  • @stefanescuradu9649
    @stefanescuradu9649 4 หลายเดือนก่อน

    It would be great if the services would be like this on the actual site as well but what you find in there sometimes is terryfing.

  • @HassanAhmed-pu4wd
    @HassanAhmed-pu4wd 4 หลายเดือนก่อน

    Yet another excellent presentation with loads of great information!

  • @AdamP-le2we
    @AdamP-le2we 5 หลายเดือนก่อน

    UKPN doesn't accept this detail due too it hasn't got any structural element' if services fall the fire batt would fail.

  • @ingusandersons3800
    @ingusandersons3800 5 หลายเดือนก่อน

    Service supports should be 100 - 400mm of firewalls, 400mm or less means that they can install it tight to wall and when you have to istall face fit batt service support is in the way.

  • @jimmccorry7193
    @jimmccorry7193 5 หลายเดือนก่อน

    Very informative as usual

  • @НикитаДимич-о7б
    @НикитаДимич-о7б 5 หลายเดือนก่อน

    you have examples how do this?

  • @dayarchitectural3843
    @dayarchitectural3843 5 หลายเดือนก่อน

    Another great episode!

  • @arekarek1991
    @arekarek1991 5 หลายเดือนก่อน

    Uk is so backwards to compare to Europe.

  • @yeehawongi4920
    @yeehawongi4920 6 หลายเดือนก่อน

    Great stuff! All of the metal pipes need to be wrapped with insulation? Why not for those metal cables on cable tray 8:20?

  • @waynebarrow7260
    @waynebarrow7260 6 หลายเดือนก่อน

    Well done Quelfire! Genuinely appreciate your efforts to educate and that you are taking such a practical and full scope look at passive fire protection, not just promoting your products. I can see where the Glenfell tragedy has driven much discussion of competency and Dame Judith Hackitt's statement of "Competency can no longer be assumed", but it is great that you are pushing that truth to your field and customers. I especially appreciate the comments about Engineering Judgments and Mandy's comments about NOT certifying "solutions" that have not been tested or that have no test data to support them.

    • @FirestoppingSolutions
      @FirestoppingSolutions 6 หลายเดือนก่อน

      Thank you for your feedback Wayne - we definitely believe in transparency and education in the industry, especially post-Grenfell.

  • @НикитаДимич-о7б
    @НикитаДимич-о7б 6 หลายเดือนก่อน

    great company)

  • @Bh1979.
    @Bh1979. 7 หลายเดือนก่อน

    Can't fault your company for testing all sorts of details, my issue is why is the fire batt so brittle?

  • @sudoku1980
    @sudoku1980 9 หลายเดือนก่อน

    Great presentation. But I don't think it was a sleeved gas pipe.

  • @arturasmarchelo4696
    @arturasmarchelo4696 11 หลายเดือนก่อน

    Its not a fierstopping, its decorative hp mastic applying, because mastic should be in all depth of fierbatt😢

    • @FirestoppingSolutions
      @FirestoppingSolutions 11 หลายเดือนก่อน

      Hello, thanks for your comment. QuelStop HPE Sealant should be installed as per our fire test evidence and for this application it is a 25mm depth, as shown on detail QB-FW100-D-02.

    • @davidiarus
      @davidiarus 5 หลายเดือนก่อน

      ​@@FirestoppingSolutionswhat for hp onto armoured cables ?

  • @martinbainbridge7355
    @martinbainbridge7355 11 หลายเดือนก่อน

    Very informative thank you. I am still not clear if hospitals and residential care homes over 7-floor or 18-metres only, will in the future fall into the higher risk category. Or, if the intention is for all hospitals and care homes to be considered higher risk?

    • @alecpurdie7181
      @alecpurdie7181 11 หลายเดือนก่อน

      If you go to this Gov.uk page it provides the current criteria: www.gov.uk/guidance/criteria-for-determining-whether-a-new-building-that-is-being-designed-and-constructed-is-a-higher-risk-building#:~:text=For%20the%20design%20and%20construction%20part%20of%20the%20regime%2C%20higher,have%20at%20least%207%20storeys. You will see this paragraph: For the design and construction part of the regime, higher-risk buildings are defined as buildings with at least two residential units, care homes, and hospitals which are at least 18 metres in height or have at least 7 storeys.

  • @НикитаДимич-о7б
    @НикитаДимич-о7б 11 หลายเดือนก่อน

    Hello,how you testing your details?)you have video?)

    • @FirestoppingSolutions
      @FirestoppingSolutions 11 หลายเดือนก่อน

      Hello. Thanks for your comment and question. We do have a video coming soon, so keep a look out!

  • @HassanAhmed-pu4wd
    @HassanAhmed-pu4wd ปีที่แล้ว

    Hi Glenn. Great presentation, thanks. Question regarding the one sided batt application, us it tested from both sides or just the application side? Thanks.

    • @FirestoppingSolutions
      @FirestoppingSolutions ปีที่แล้ว

      Hello Hassan, thank you for your feedback and question. Our single-side access details are always tested from both sides to replicate a worst-case scenario. If you would like more information on these details and the testing, please contact technical@quelfire.co.uk.

  • @garnolan34
    @garnolan34 ปีที่แล้ว

    Great video again Glenn. Thanks for the information. Garrett

  • @BarryDean007
    @BarryDean007 ปีที่แล้ว

    Will this be good study for Level 2?

    • @FirestoppingSolutions
      @FirestoppingSolutions ปีที่แล้ว

      Hi Barry, thanks for your question. It most certainly has some useful content for Level 2. Episode 6 might be a good watch as it specifically delves into Level 2 & 3, discussing the exams: th-cam.com/video/9drcq1YgJJk/w-d-xo.htmlsi=c4YH8r5mtP0_T6ca

  • @bardechampagne7710
    @bardechampagne7710 ปีที่แล้ว

    😕 Promo'SM

  • @liamwilson5830
    @liamwilson5830 ปีที่แล้ว

    Doesn’t hp corrode cvpc?

    • @FirestoppingSolutions
      @FirestoppingSolutions ปีที่แล้ว

      Hello Liam, thanks for your question. Certain products can be non-chemically compatible with CPVC pipes. Only approved HPE sealants such as the QuelStop HPE Sealant, which has been approved by both Lubrizol and Spears for use on their CPVC systems, can be used. For more information, read this knowledge hub piece: quelfire.co.uk/knowledge-advice/considerations-when-firestopping-cpvc-pipes/ or contact us at technical@quelfire.co.uk.

  • @ytshorts-nx8vb
    @ytshorts-nx8vb ปีที่แล้ว

    That one is new to me

  • @eddymk8381
    @eddymk8381 ปีที่แล้ว

    Is it true that before applying HPE on it, we have to use reflective tape on the pipe?

    • @FirestoppingSolutions
      @FirestoppingSolutions ปีที่แล้ว

      Hello, thanks for your question. In some cases, reflective tape is required when the sealant is not approved. However, this is not the case for our QuelStop HPE Sealant as it has been approved by the two main manufacturers of CPVC pipes. Read our short article for more information: quelfire.co.uk/knowledge-advice/considerations-when-firestopping-cpvc-pipes/ If you do have any more questions, please don't hesitate to email us at technical@quelfire.co.uk.

  • @waynelister1285
    @waynelister1285 ปีที่แล้ว

    He'll happily tell you I was the best about haha

    • @MICHAEL-wg2lh
      @MICHAEL-wg2lh 7 หลายเดือนก่อน

      I've heard about you , I heard you left your horse on one of the jobs lol

    • @waynelister1285
      @waynelister1285 7 หลายเดือนก่อน

      @@MICHAEL-wg2lh what do you mean by a horse 🙄

  • @waynelister1285
    @waynelister1285 ปีที่แล้ว

    I used to work for these, probably the best company you can work for in passive fire protection, keiran the manager is a top man

    • @ytshorts-nx8vb
      @ytshorts-nx8vb ปีที่แล้ว

      Am I moving to this company now 😂

    • @waynelister1285
      @waynelister1285 ปีที่แล้ว

      @@ytshorts-nx8vb keep your head down and work to the correct detail they will love ya

  • @cyanide170
    @cyanide170 ปีที่แล้ว

    when are M&E going to start taking into considertaion for service seperations..

  • @coralmorgan4005
    @coralmorgan4005 ปีที่แล้ว

    Brilliant - really useful and engaging. Well done🙂!

  • @fcbarcelona9149
    @fcbarcelona9149 ปีที่แล้ว

    Great🎉 looking foward to part 3

    • @FirestoppingSolutions
      @FirestoppingSolutions ปีที่แล้ว

      Thank you for your feedback. We are pleased to hear this! If you do have any questions you'd like answered then please don't hesitate to send them into marketing@quelfire.co.uk and we will be happy to help.

  • @HassanAhmed-pu4wd
    @HassanAhmed-pu4wd ปีที่แล้ว

    Thank you chaps - some great tips again!

    • @FirestoppingSolutions
      @FirestoppingSolutions ปีที่แล้ว

      Thank you for your feedback, we're glad you find it useful.

  • @cyanide170
    @cyanide170 ปีที่แล้ว

    the man behind phone. aidan j hare

  • @Globaltecbrasil
    @Globaltecbrasil ปีที่แล้ว

    👏👏👏

  • @fcbarcelona9149
    @fcbarcelona9149 ปีที่แล้ว

    This video can help you with IFE level 3

    • @FirestoppingSolutions
      @FirestoppingSolutions ปีที่แล้ว

      Thank you for your feedback, we are glad you find this useful. If you have any questions you would like the team to answer regarding IFE level 3 then please email them in at marketing@quelfire.co.uk and we will be happy to help!

  • @davidl2229
    @davidl2229 ปีที่แล้ว

    👊 𝓹𝓻𝓸𝓶𝓸𝓼𝓶

  • @thomaswelbrn8522
    @thomaswelbrn8522 ปีที่แล้ว

    what EI rating do you achieve on the trunking?

    • @FirestoppingSolutions
      @FirestoppingSolutions ปีที่แล้ว

      Hello Thomas, thank you for your comment. We have a number of trunking details - some standard details and also some future details. Please contact our technical team regarding your application at technical@quelfire.co.uk

  • @mgcservices7524
    @mgcservices7524 ปีที่แล้ว

    Hello Alec, excellent video and fantastic range of products. Can you tell me if there are any tests conducted on plastic concertina pipes, the type normally witnessed from the back of a tumble drier or bathroom/kitchen extraction fan system; would a fire collar be suitable - pipe diameter is approx 110mm.

    • @FirestoppingSolutions
      @FirestoppingSolutions ปีที่แล้ว

      Thanks for your feedback. We don't know of any tests carried out on the material you describe. Because the material is so thin and combustible, it is likely that it would burn quicker than the intumescent can react resulting in an integrity failure. It is always worth checking whether these ducts are actually penetrating a fire compartment wall initially. For more technical questions please send in specific details to our technical team using technical@quelfire.co.uk

  • @NINJASTYLEART
    @NINJASTYLEART ปีที่แล้ว

    👍

  • @mattdewet6908
    @mattdewet6908 2 ปีที่แล้ว

    Hi Alec, this is a fantastic range, well done. Could you please give me a bit more detail about the gas pipe passing through a sleeve. it looks like QB-FW100-D-12. I have seen similar, with copper pipes passing through another copper sleeve. i never got an answer as to the reason for the sleeve and need for the gap between 2x pipes. also, is there no need for a HPE or wrap? as the yellow gas pipe would surely not be sealed off by acrylic seal alone? many thanks

    • @FirestoppingSolutions
      @FirestoppingSolutions ปีที่แล้ว

      Hello, thank you for your comment. We believe the "reason" for sleeve is due to a gas regulation or could also be due to concerns about movement and potential chaffing of the pipe on the substrate. From our perspective, we test fire stop solutions for scenarios that arise in real life and this is how the pipes can be installed. See also: quelfire.co.uk/knowledge-advice/does-tracpipe-need-to-be-sleeved/. On detail QB-FW100-D-12 quelfire.co.uk/wp-content/uploads/QB-FW100-D-12-Trac-Pipe-penetrating-a-flexible-or-rigid-wall-HPE.pdf you will note that a 20mm annulus of QuelStop HPE Sealant is required around the sleeve. The QuelStop Intumescent Acrylic Sealant is used to seal the gap between the sleeve and the pipe on one side of the wall only in this case. If you have any further technical questions please send a detailed question to technical@quelfire.co.uk where one of the team will be glad to support further. Thank you.

  • @tudorcasian1812
    @tudorcasian1812 2 ปีที่แล้ว

    Great video Alec, thank you

  • @LILAH4YOU
    @LILAH4YOU 2 ปีที่แล้ว

    Super star ⭐️ xxx❤️

  • @kirbymoody6985
    @kirbymoody6985 2 ปีที่แล้ว

    🤗 ≋p≋r≋o≋m≋o≋s≋m