PASSIONATE ENGINEER
Pakistan
เข้าร่วมเมื่อ 29 มี.ค. 2012
PASSIONATE ENGINEER ✅
This channel is created to provide information regarding Mechanical Engineering from basic to Pro-Level such as
HVAC design, installation, testing, balancing and commissioning.
CAD (AutoCAD, Pro-E etc).
Books and other material regarding Engineering standards.
We are MEP Professionals providing designing, installation, testing, balancing and commissioning service around the globe.
This channel is created to provide information regarding Mechanical Engineering from basic to Pro-Level such as
HVAC design, installation, testing, balancing and commissioning.
CAD (AutoCAD, Pro-E etc).
Books and other material regarding Engineering standards.
We are MEP Professionals providing designing, installation, testing, balancing and commissioning service around the globe.
HAP V5.1 Complete Training Part-1
Take advantage of this paid course by Carrier, it's free. Thank me later.
มุมมอง: 157
วีดีโอ
Conquer Your Fears Unlock Your Potential | Motivation for Engineers
มุมมอง 38หลายเดือนก่อน
Conquer Your Fears Unlock Your Potential | Motivation for Engineers
Cleanroom HVAC Design - Code Requirements
มุมมอง 8937 หลายเดือนก่อน
#iso #cleanroom #ventilationsystem #fanfilterunit
Transformer Room Ventilation System Design and Calculation
มุมมอง 8637 หลายเดือนก่อน
#transformers #hvac #mepengineering #ventilationsystem Download Calculation files using below link. passionatengineer.blogspot.com/2024/03/transformer-room-ventilation-system.html
Diffuser Selection | How to Design a Good Air Terminal for Different applications.
มุมมอง 97611 หลายเดือนก่อน
#diffuserselection #cleanroomairdiffuser
Car Parking Ventilation System Design (HVAC)
มุมมอง 2Kปีที่แล้ว
#ashrae #nfpa #highrisebuildings #construction #ventilationsystem #firefighting #earthquake
HOW TO DESIGN STAIRCASE PRESSURIZATION SYSTEM
มุมมอง 5Kปีที่แล้ว
In a high-rise building, the stairs typically represent the sole means of egress during a fire. It is imperative for the exit stairs to be free of smoke and to incorporate design features that improve the speed of occupant egress. Most building codes require the fire stairwells in a high-rise building to be pressurized to keep smoke out. The stairwell pressurization serves several purposes: Inh...
DUCT HEATER CAPACITY CALCULATION (HVAC)
มุมมอง 4.7Kปีที่แล้ว
A duct heater is an electric heating device designed to be installed into a duct system for the purpose of providing supplemental or primary heating for a space. Duct heaters can be installed in new or existing systems and are usually powered by electricity. They are often used to heat large commercial or industrial buildings, such as warehouses and factories. Download excelsheet using below li...
Fundamentals of HVAC Space Air Diffusion.
มุมมอง 397ปีที่แล้ว
Fundamentals of HVAC Space Air Diffusion.
How To Do Energy Audit of building by RETScreen (HVAC System)
มุมมอง 6K2 ปีที่แล้ว
How To Do Energy Audit of building by RETScreen (HVAC System)
How To Calculate ESP of Duct Using "ASHRAE FITTING DATA BASE"
มุมมอง 12K2 ปีที่แล้ว
How To Calculate ESP of Duct Using "ASHRAE FITTING DATA BASE"
How to calculate Coil load by using Psychometric Analyzer
มุมมอง 7K2 ปีที่แล้ว
How to calculate Coil load by using Psychometric Analyzer
Cooling Coil load calculation using Psychometric chart
มุมมอง 18K2 ปีที่แล้ว
Cooling Coil load calculation using Psychometric chart
How to Calculate pressure in Clean room HVAC (ENGLISH).
มุมมอง 27K3 ปีที่แล้ว
How to Calculate pressure in Clean room HVAC (ENGLISH).
Learn Heat-load calculation for Pharmaceutical Area and Hospitals by HAP.
มุมมอง 12K3 ปีที่แล้ว
Learn Heat-load calculation for Pharmaceutical Area and Hospitals by HAP.
How to design Underfloor Heating by LoopCAD (Manual J method).
มุมมอง 24K3 ปีที่แล้ว
How to design Underfloor Heating by LoopCAD (Manual J method).
Design of Smoke extraction system (Smoke Management System) (ENGLISH)
มุมมอง 22K4 ปีที่แล้ว
Design of Smoke extraction system (Smoke Management System) (ENGLISH)
How to calculate Pump Head by Pipe Flow Expert - Chilled Water System (ENGLISH)
มุมมอง 7K4 ปีที่แล้ว
How to calculate Pump Head by Pipe Flow Expert - Chilled Water System (ENGLISH)
Learn ESP calculation by very simple method (ENGLISH)
มุมมอง 15K4 ปีที่แล้ว
Learn ESP calculation by very simple method (ENGLISH)
Designing and calculation of HVAC system for Hospital by HAP (ENGLISH)
มุมมอง 22K4 ปีที่แล้ว
Designing and calculation of HVAC system for Hospital by HAP (ENGLISH)
Design Guidelines for HVAC system of OT (Operation Theater) (ENGLISH)
มุมมอง 38K4 ปีที่แล้ว
Design Guidelines for HVAC system of OT (Operation Theater) (ENGLISH)
How to design and calculate stairwell pressurization system (NFPA STANDARDS) (ENGLISH)
มุมมอง 38K4 ปีที่แล้ว
How to design and calculate stairwell pressurization system (NFPA STANDARDS) (ENGLISH)
How to make Duct Tag list and why its important for HVAC site Engineer and contractor. (ENGLISH)
มุมมอง 5K4 ปีที่แล้ว
How to make Duct Tag list and why its important for HVAC site Engineer and contractor. (ENGLISH)
How to design Duct system and select shapes of duct (HVAC) (ENGLISH)
มุมมอง 1.3K4 ปีที่แล้ว
How to design Duct system and select shapes of duct (HVAC) (ENGLISH)
External Static Pressure (ESP) Calculation by ASHRAE handbook method. (ENGLISH)
มุมมอง 40K4 ปีที่แล้ว
External Static Pressure (ESP) Calculation by ASHRAE handbook method. (ENGLISH)
HVAC Design For Cleanroom Facilities (ISO CLASSES) and ASHRAE guidelines (ENGLISH)
มุมมอง 11K4 ปีที่แล้ว
HVAC Design For Cleanroom Facilities (ISO CLASSES) and ASHRAE guidelines (ENGLISH)
VAV (variable air volume) system working principle (ENGLISH)
มุมมอง 5K4 ปีที่แล้ว
VAV (variable air volume) system working principle (ENGLISH)
ASHRAE design guidelines for COVID-19 Patient isolation room HVAC system. (ENGLISH)
มุมมอง 3.2K4 ปีที่แล้ว
ASHRAE design guidelines for COVID-19 Patient isolation room HVAC system. (ENGLISH)
Pump calculation and selection (ENGLISH)
มุมมอง 2.3K4 ปีที่แล้ว
Pump calculation and selection (ENGLISH)
Any free 90 trial code ?
You mean for HAP 5.1?
@passionateengineer04 any version above the 4.9 version
Crack version is available
what do you mean by cps on number 4 equation
How 87.8 wet bulb is possible.
@ahmedshafath this is just for the purpose of understanding the software. There are different places where WB is above 80. During load calculation, always calculate at 2 conditions ,1- maximum dry bulb temp, 2- at dedumification conditions. The coil will selected either based on condition 1 or 2 which ever is greater.
we can calculate fresh air using HAP, why psychrometric
You can with HAP, but not always. You must have knowledge of how to do that with psychometric.
@@passionateengineer04 Thanks , is there any video or ASHRAE Psychrometric is enough, I read from it they are stating that " It is best practice to contact a cooling coil manufacturer (or run their cooling coil selection software)
The best way is to contact the manufacturer, but you have to provide coil ADP, which depends on the loads conditions. Psychometric is a quick way to analyse what you need and what will be provided to manufacturers
Thanks a lot , what about Coil ADP provided by HAP can this be relied.
It is also good if you did the calculations in the right way because internally, you have no idea how HAP is calculating the coil ADP. HAP is based on heat balance.
Could you tell me what kind of tool you used to measure? Is this a tool that measures degrees? Another question, where did you get the measurement to mark the tube for bending?
you divide volum flow rate ( m3/min ) with specific volume ( m3/kg ) should you get mass flow rate in kg/min instead of kg/s ? since you are using perminute so Q out is kw/min not kw/h correct ?
There is a formula in the Excel sheet, which is directly converting the value. I'm sorry to show this in the video, but you can follow your calc.
Can you share the excel document?
It's in the video description. Thank you
Does the bender have any notch or any mark for 45, 30, 10, 22.5, 60 ?
could you procide a CAD drawing please
Sir you cont number send me
can you please share this presentation
Share your email
Can you share this pdf file??? I am also requesting you to share sample heat load excel file or one video for sample heat load + AHU selection.
Please share your email
Can you provide me video for isolation room HAP design?
Sure
@@passionateengineer04 I'm waiting
Dear Sir, how did you get the value of 0.2 differential pressure inch w.g. for the Q2 calculation?
Its standard depends on the door opening force. Refer NFPA and ASHRAE handbook
@@passionateengineer04 Do you have design calculation for Fire Lift Shaft pressurisation and fire fighting lobby?
@ShashiSanmukhiya yes
@@passionateengineer04 can you send me the link for the video on youtube if possible.
Please share you email
Great video sir. But I have a bit of a doubt. In one of our project quote that was given to us the pressure in one of the rooms (bio safety room) is given as negative. No parameters are given in it for pressure..in this case what do I do?
If you want a detailed calculation, refer to ASHRAE, you need to calculate wall leakage, door leakage, etc. Before this, you need to calculate the required cfm based on ACH min of 20 for cleanrooms
did you include wastage when calculating the duct area?
No, it's just area calculation. Wastage will be added in weight sheet
Can you share the cad file? Thank you.
Nice video sir. Is there an SI unit version of the excel sheet? Thank you
Can I also get a copy of the drawing?
Share your email address please
Sorry, not available
Can u put a video for ESP calculation for fcu unit which has 90 elbows , transition like for big duct from corner to other .Please kindly link and sheet .Thanks in advance.
Sure, and I have also selected some topics for other video, but unfortunately, we are busy withn some projects Thank you
Hiii
Hi
Hi, nice and really very helpful. thank you man ...
I sent you email please if you reply 🙏💐
Hello , I don't think that using high ACH in load calculation is correct ,, ACH that must be used in HAP is the one related to fresh air requirements , however, the ACH related to cleanliness should be considered to calculate the number of fan filter units to circulate the air through HEPA filters , hope to hear back from you.
Sorry for that, but you are not right, ACH is a part of load calculation. Based on this, you will select equipment and cfm/ton. Coil load and supply air temp depends on this. Thank you
@@passionateengineer04 thanks for your reply ,, but I did many cleanrooms in Canada ,, ACH doesn't mean fresh air ,, these are two different things ,, I agree that fresh air is part if the load calculation and it can be part of the ACH ,, but considering that ALL the ACH is fresh air is something that we don't do .
Both ACH are part of load calculation. If you are working in Canada, then it's also the same, but the difference is the fresh air unit, like if you are using HRV, makeup air unit etc than you don't need to consider the fresh air ACH. You can do differently, calculate the load, and than put user define air flow based on ACH.
In which province of Canada are you working? Are you familiar with CSA Z317.2? ALBERTA COLLEGE OF PHARMACY?
@@passionateengineer04 I work in Ontario,, would be great if we can have a call to discuss.
Hello. I successfully downloaded the trial Avenir LoopCAD "LoopCAD2024-Roth-Setup.exe" file, HOWEVER it will not load on My Apple MacBook M1 laptop running Sonoma 14.5. It wants to open with my Elmedia Flash Player. I adjusted my Flash player, per Apple instructions to open with "Rosetta" but still not opening the ".exe" file. Any idea what the issue is?
Sorry, i didn't use it on macbook yet, i am using it on Windows 11. You may check the internet for a solution.
You can try looking up a software for emulating windows 11 on ios and run it there
Very informative videos.Thanks for sharing ur knowledge. Can u kindly share Esp excel sheet .
Please check the video description
This was really helpful thank you. I did have a question if I have a positive pressure environment located in a lab and I have a heatload within the positive pressure environment, how do I calculate the amount of cfm I'll need to remove the heatload into the lab?
Sorry, i didn't understand your question, can you please elaborate?
if you know the load then you can use sensible heat equation that Q= 1.08xcfmxdelT
You didn’t consider grille pressure drop that will come around 10-20 pa
Sir can we get the soft copy of word file
Share your email
Hi, thank you for your nice video sir.
Why you are wasting time in converting mm to inches go to setting n units and change it ...........................
Thank you Sir. I loved your explanation. Can you please share with us the link of the excel sheet for reference. I will be grateful.
I got it from the description. You shared it already.
Can you please help me where to find the excel file ?
@@GEORGEPAPATHANASIOU-b3k go to the video description. The is there
@@GEORGEPAPATHANASIOU-b3k passionatengineer.blogspot.com/2023/03/staircase-pressurization-system-design.html
fire area in not as the floor area this will increase the fan m3/s
It's depends on the situation. The fire area is actually the area separated by fire rated walls if the attrium wall are fire rated and fire will not transfer from internal space like shops etc to the attrium,than only attrium area will be considered as a fire area.
I think there is some problem in this video regarding that and window exposure in its properties you expose all 4-side wall how???
It's just for calculations.all depends on the building orientation
Sir, can we get the revit arch model of this drawing for practice? Or any other model for practice?
Area of Floor & Ceiling =L x W= 17.5 x 8.5 =148.75 sqft but in your calculation showing 297.5 sqft. can u explains how came 279.5 sqft ? Door 7x3 =21 , 20 ft will be gap length.
First of all its not 21, its 20 and its not 7x3, its (7+3)*2 (perimeter) and second is 17.5*8.5*2= 297.5, these are not like your calculations because these are not cross sectional areas.
Please first understand the concept, how to calculate the areas etc than go for the other calculations, these are not straight forward cross sectional areas, because i didn't mentioned any cross sectional area, these methods are based on NFPA and ASHRAE, all references are given in excel sheet, go through it and please don't confuse other viewers. Thank you
"HEAT RELEASE = 93 KW/M2 FOR FURNATURE 310 KW/M2 FOR CELLULOSICS (ورق كارتون للتعبئه والتغليف و منتجات قطنية) 260 KW/M2 FOR VIHICLES(car park) I can't to find in NFPA 204, NFPA 92 and BS 7436-4? You can hepl me?
Please share your email, i will send you.
kindly send to me the specifications in a word file, thank you
Please share your email address
Sir please share you contact number me
Naqqash.sajid@gmail.com Contact me on this.
Where can I get this software??
I will share the link
Do you only calculate air volume, and not pressure needed for air flow to reach the bottom flor?
These air flow is based on standard pressure as per IBC and need to maintain maximum pressure of 90 pascal, so the door opening force doesn't exceed.
nice job, send me the link
Does installing a smoke extraction system also mean I will handle the ventilation in the parking garage? I mean are they not the same ??
The fan shall be VFD drive and interlocked with smoke sensors, when the smoke is detected, the fresh air fan will stopped and exhaust fan shall run at high speed to extract the smoke. That why we design parking ventilation at 6 ach normal operation and 10 ach for fire incident.
Thank you so much
This is so useful. Thanks for this video- Greetings from Colombia
Sir do you have the electrical technical specifications in a word file similar to the one you have shown here?
Share you email address
Thank you. This was helpful
Which type of duct used in staircase pressurization... GI or fire rated duct ? Kindly reply
GI can be used with fire damper at penetration. Better to use fire rated duct if possible.
Refer to local code or AHJ.
Engr. please tell which one is mostly used in UAE
In UAE all ducts related to basements parking, makeup air unit, smoke extraction, staircase pressrization are fire rated. But you can also confirm from local code ie municipality etc.
@@passionateengineer04 Should i prefer Coated or non-coated fire rated ducts for smoke extraction?
Hie, great staff can l get your Excel sheet
You can find link in description
in Patient room, why outdoor ventilation air =0 , SA=280 CFM, it means using 100% RA, I seen you input= 23 CFM but result =0
Yes, you right, i think it was mistakenly removed, during video recording. You can follow the procedure by yourself, i was teaching the method to do such calculations
Hello, very informative. CAn i ask where to find the sofware that you used for cooling load calculations?
HAP 4.9 or 5.1 can be downloaded from internet for free
I have a question the translation should have different hight size , coz am trying with the some size then boom an error
Transition have two different sizes smaller and bigger