super sir nice video common man's problem . every person faces it when the service wire got damaged (i.e only neutral wire cut-off or the wire connection at pole got damaged ) or the wire in neutral slot cut it is very easy step:1 see the service wire condition then step:2 also see the meter board connection at this situation i use clamp meter (tong tester) for checking neutral continuity by turning off the power supply
My doubt bro. Please ans. All appliances are working. Bulbs, tvs,.. ఎత్చ్. But both sides means phase and neutrol also glowing when i insert taster. And when i off switch neutrol is glow. What is the problem and solution please
Intlo undedi 1-ph supply kada.. neutral fail aite Appudu intlo tv, fan and lights lantivi asalu operate avvavu.. Ante tv on avvadu, fan tiragadu annamata. Endukante neutral ledu kada.. Same phase bulb rendu terminals ki iste bulb velagadu endukante bulb across ga potential difference zero kanuka..
Ekkada Ekkada connecting points untayo aa points ni check chesukovadame.. Oka room lo problem unda leda anni rooms lo Unda .. Anni rooms lo aite main distribution daggare , mains nunchi intlo ki vache daggare disconnect aii undochu.. Mana common sense to easy ga kanukko vochu, check chesukuntu povadame..
Without connecting earth or Neutral or other phase or phase shifting device, simply connecting same phase at the both terminals of bulb, it is not possible to glow the bulb.. You are welcome lavanth viggina..
Tester will not work on un grounded neutral systems and un grounded dc systems.. it means it will not glow at all.. I can't understand what is your exact problem.. Anyway you just check the the voltage using multimeter between two terminals and between one terminal and ground if it is available.. then you may get to know, what to do what not to do ...
Bro... please answer....ah Socket ki 2 phases vasthe aah socket lo edaina applaince pedithey Adhi Damage authundhaa.....Like TV or AC plug pedithey Adhi damage authundhaa??
Mana intlo undedi single phase supply kada.. ikkada fail aina neutral kuda mana intiki sambadinchina neutral kanuka, ikkada socket ki rendu vipula appear aiyyedi mana intlo phase ee kada. Ante same phase socket ki rendu vipula vastundi.. Same phase socket yokka rendu points daggaraku vastundi kanuka, aa rendu points madya potential difference zero avutundi.. kabatti tv operate avvadu. Inkoka sari video chudu.. neeku clear ga ardam avutundi.. All the best..
@@ElectricalEngineeringTelugu haa..Adhi ardam aindhi.....ma intlo stabilizer lo Output 2 sides phase vasthundhi and output indicater glow avadam ledu....andulo TV pedithe On avvadhu ...but 2 side phase valla internal ga emanna damange authundhaa TV lo....??
The reason might be found in the following video. th-cam.com/video/0l8H5GPiHI4/w-d-xo.html Watch the video for clarity All the best siddeshwar prasad..
@Electrical Engineering Telugu గారు మీ reply కి నా ధన్యవాదాలు...సర్ మీరు చెప్పినట్లుగా న్యూట్రల్ ని common గా ఇవ్వడం వల్ల కరెంట్ బిల్లు పెరిగే అవకాశం ఏమన్నా ఉంటుందా ఆన్నది మాత్రమే నా డౌట్ సర్.... చిన్న చిన్న load కి టీవీ, fan, bulb ఇలాంటి వాటికి న్యూట్రల్ ని common గా ఇవ్వడం ok అని మీ వివరణ వల్ల నాకు అర్థం అయ్యింది.... కానీ ఏసీ, fridje, geaser, ఐరన్ బాక్స్, పెద్ద load గల ఎక్కువ ampers కల వాటికి కూడా న్యూట్రల్ ని కూడా common గా ఇవ్వవచ్చా అన్నది మాత్రమే నా డౌట్ సర్.. ( పొరపాటున కామన్ ని series అని వాడాను క్షమించాలి) నేను electricitry మీ లాంటి వాళ్ళు పెట్టె వీడియో లు చూసి నేర్చుకుంటున్నాను...మీ అందరికి మరి ఒకసారి ధన్యవాదాలు
Very good Ramya siramdas Garu.. According to Indian Electricity rules Mana loads ni manam rendu rakalu ga classify chestam . Avi 1) light and fan loads (light and fan sub circuit): ee sub circuit yokka rating 800 watts ki Minchakudadu.. corresponding ga manam wire ni choose chesukovali.. 2) power loads (power sub circuit): ee sub circuit yokka rating 3000w minchakudadu. Asalu ee rendu sub circuit ni mix cheyya kudadu.. Mana vullalo electricians ituvanti standards emi patinchukoru (vallaki teliyaka povachu).. Alage inkoka mata mee intlo load (connected load kadu maximum demand) anedi meeru chose chesukunna service mains current carrying capacity ki Minchakudadu.. Mee number post cheyyandi .. we can didcuss over telephone too for greater clarity..
@@ElectricalEngineeringTelugu 9492188443 Raju Siramdas.... Sir మీ నెంబర్ కూడా దయచేసి ఇవ్వగలరు... నా కోసం మీరు ఈ సమయం కేటాయించినందుకు నా ప్రత్యేక ధన్యవాదాలు
You just check the neutral points (how neutral would be distributed from main distribution board, main distribution board also one of the main check points) at your home, where it has been disconnected, and connect it properly. Your problem is solved.. While doing any electrical work, make sure that electrical power must and should be isolated . That is after switching off the electrical power supply, you start any electrical work. Make safety first, then start doing work.
The Main might be the faulty.. Why because, when you switch off the main, both phase and neutral must be cut off. But in this case, as the main might be the faulty, it may cut off only neutral at mains, but the phase comes to the switch boards even though the main off. So you are getting both sides phase at your socket. Now you switch off the main and remove the fuse after the mains and check for the supply at your socket on the switch boards. You may not see the supply. Even after removing the fuse, if you face the same problem, just let me know .. we will discuss over telephone too...
What are you doing, where you faced the problem.. you may not found video suggestion for it. If it is due to faulty mains, faulty mains may not available readily. You just post your number here..
@@ElectricalEngineeringTelugu I have another dought manam bulb ki rendu vaipula phase connect cheste bulb veligidda? And other dought is Socket lo one connection swith nunchi tisukuntam inkokati neutral wires connect chestam avi change aite problem untunda? Yaduku?
Modati prasnaku javabu: Bulb ki 2 vaipula same phase iste kanuka Bulb velagadu.. Ala kakunda oka vaipu R-Phase, rendo vaipu Y-Phase Ala different phase lu iste , Aa bulb 230V rating bulb aite filment rali potundi.. Oka vela bulb 415v rating kanuka aite velugutundi.. 2 va question ki javabu: Phase anedi eppudu fuse, switch dwarane ivvali.. direct ga ivvakudadu.. Nenu previous ga pettina link aade.. okasari chudu.. Aina ikkada Kuda link istunnanu.. okasari chudu.. th-cam.com/video/0l8H5GPiHI4/w-d-xo.html
@@ElectricalEngineeringTelugu sorry bro light velugutundi Problem entante prathi socket lo switch off chesina neutral side power vastundi and Anni appliances baane Pani chestunnai
How can you tell you that is neutral side, that might be the phase side. You just check again if tester glows on both sides of socket, just let me know. You may also check for this, the phase must be connected to switch, but some local electricians giving neutral to switch and phase to equipment directly which is wrong and very much danger too. Thanks...
Sir namasthe... నాకు ఒక డౌట్ ఉంది దయచేసి reply ఇవ్వగలరు...మీరు ఇచ్చిన సర్క్యూట్ లో L1. L2. L3 fan, tv line wire లాగానే న్యూట్రల్ wires ని కూడా 6 పాయింట్లకి విడిగా తీసుకొని 3 pin socket లో కలపడం ok నా అలా చేయడం వల్ల కరెంట్ బిల్లు తక్కువ వచ్చే అవకాశం ఉందా...లేకపోతే మీరు చెప్పిన విదంగానే neutral ని ప్రతి load కి series కలపడం బెటర్ అంటారా?...దయచేసి చెప్పగలరు...నేను yotube లో వీడియోలు చూసి house wiring గురించి నేర్చుకుంటున్నాను
Hi ramya siramdas garu.. Neutral ni series ga ivvaledu, parallel gane ichamu.. adenandi common ga icham.. Meeru anukunnatlu ga kuda cheyya vachu.. Endukante manaki 1-ph equipment operate avvalante phase and neutral rendu ivvali kada.. Meeru neutral ni separate ga ivvali anukunte oka common bus ni tisukoni Daniki electricity board nunchi vachina neutral ni connect Chesi, aa bus nunchi individual loads ki separate ichukovachu.. kani dani valla copper wire requirement (initial cost) perugutundi. So associated copper losses kuda perugutai kani taggav(ante current bill perugutundi kani taggadu). Common bus nunchi okkokka room( okkokka sub circuit) ki okkokka neutral wire ni alage okkokka phase (phase bus nunchi) wire ni distribute chesukonte manchidi ani na abiprayam. Dani valla trouble shooting, alage initial cost and losses point of view lo kuda optimum ga untundi..
@@ElectricalEngineeringTelugu మీ reply కి నా ధన్యవాదాలు...సర్ మీరు చెప్పినట్లుగా న్యూట్రల్ ని common ( పొరపాటున series అని వాడాను క్షమించాలి) ఇవ్వడం వల్ల కరెంట్ బిల్లు పెరిగే అవకాశం ఏమన్నా ఉంటుందా ఆన్నది మాత్రమే నా డౌట్ సర్.... చిన్న చిన్న load కి common గా ఇవ్వడం ok అని మీ వివరణ వల్ల నాకు అర్థం అయ్యింది....కానీ ఏసీ, fridje, geaser, ఐరన్ బాక్స్, పెద్ద load గల ఎక్కువ ampers కల వాటికి కూడా అలా ఇవ్వవచ్చా అన్నది మాత్రమే నా డౌట్ సర్.. నేను electricitry మీ లాంటి వాళ్ళు పెట్టె వీడియో లు చూసి నేర్చుకుంటున్నాను...మీ అందరికి మరి ఒకసారి ధన్యవాదాలు
Yes bro ... I also faced same situation
This is correct explanation ..
I am happy to see this telugu channel with orginal eletrical countent ❤️
To increase view to solve the faceing problemes thank broo ...
You are welcome jetti.balanagu4337
super sir nice video
common man's problem .
every person faces it when the service wire got damaged (i.e only neutral wire cut-off or the wire connection at pole got damaged )
or the wire in neutral slot cut
it is very easy
step:1 see the service wire condition then
step:2 also see the meter board connection
at this situation i use clamp meter (tong tester) for checking neutral continuity
by turning off the power supply
Correct kani second socketlo phase right side undali bro
A perfect enginner with perfect and practical example..... KUDOS 👏👏👏🤝🤝🤝
You are welcome naresh..
అన్న ...,.నాకు interview loo ఇదే ప్రశ్న అడిగారు .... కానీ cheppalekapoya కానీ ఇప్పుడు full గా clarity వచ్చింది.,.tq...
All the best harsha priya..
Chala useful information icharu..thank you for your support
100% correct bro. Iam phased this type of problem
You are welcome vasanthtechintelugu
Superb👌👌👌& good work sir
You are Welcome Chandu.
Annaya super ga explain chesav super❤️👍
Thank you. Welcome to our Electrical Engineering Telugu family Nithin Sai..
Just go to play list in our channel. You will find lot of such questions..
🎉Thanq,Brother Good information🤗🤝🤝✊💪✊👌👌👍...🎉
Thanks brother good information nice video
Awesome explain bro
You are welcome naresh , ramesh
Super Anna thank you so much
What a explanation bro super 👍👍👍
You are welcome vinod
Facing this problem in all sockets in our home what to do ? Bro
Practical ga chupinchandi
Thank u ,same problem iam facing
Today i faced same problem sir. Thanks
Anna mi explanation Chala బాగుంది
Okay, you are welcome venkanna babu
Nice information brother. Nd nice explain
You are welcome satish roja
Super explanation bro
Super bro iam soo happy
You are welcome heart beat
I solve my problem thanks
Ss that is called nuetral failure 🥰
Really TQ very much broo.......
You are Welcome Ganesh..
Super brother
Keep going on
Thankyou bro
Super explanation !
You are welcome anant raju
👍
Good explanation bro tqq
You are welcome satish..
Thank you sir
You are welcome raviteja..
Superbga explains broo thank you
You are welcome bro..
Simply superb bro 🙏
You are welcome Ramanjeneyulu..
Thank u so much broo
You are welcome Sampath vinay..
Phase place at right side
This is electrical rule
super bro
Super explain anna, thanks
You are welcome vishnu..
Problem identify chyatam chyparu gani but ala slove chyali chupaledhu andi ..I'm non technical person that y I asked
Thanks bro
You are welcome pawan
N cut inappudu power supply rakudadhu kada power supply vastundi adi Deni valla problem kavachu
Super bro
You are welcome yadagiri
My doubt bro. Please ans. All appliances are working. Bulbs, tvs,.. ఎత్చ్. But both sides means phase and neutrol also glowing when i insert taster. And when i off switch neutrol is glow. What is the problem and solution please
Story type class super 🤩
You are welcome bhavani.
@@ElectricalEngineeringTelugu sir repeat this type of classes sir, because it is easy to understand that..
Tq anna
You are welcome venkatesh..
Anna mari ala run ayithe entlo vunna
Items tv somethings paduavuthaya
Intlo undedi 1-ph supply kada.. neutral fail aite Appudu intlo tv, fan and lights lantivi asalu operate avvavu..
Ante tv on avvadu, fan tiragadu annamata.
Endukante neutral ledu kada..
Same phase bulb rendu terminals ki iste bulb velagadu endukante bulb across ga potential difference zero kanuka..
Same problem for me also..im getting supply in two holes
న్యూట్రల్ వైర్ ఎక్కడ కట్ అయిందో.. ఎలా కనుక్కోవాలి
Ekkada Ekkada connecting points untayo aa points ni check chesukovadame..
Oka room lo problem unda leda anni rooms lo Unda ..
Anni rooms lo aite main distribution daggare , mains nunchi intlo ki vache daggare disconnect aii undochu..
Mana common sense to easy ga kanukko vochu, check chesukuntu povadame..
Sir...onli phase tho bulb 💡 glow avvada?
Without connecting earth or Neutral or other phase or phase shifting device, simply connecting same phase at the both terminals of bulb, it is not possible to glow the bulb..
You are welcome lavanth viggina..
Sir 12v ups lo same problem sir how it fix please sir if u know
Tester will not work on un grounded neutral systems and un grounded dc systems.. it means it will not glow at all..
I can't understand what is your exact problem..
Anyway you just check the the voltage using multimeter between two terminals and between one terminal and ground if it is available.. then you may get to know, what to do what not to do ...
Sooperb explaination sir....but Ipud ah socket lo by mistake oka TV plug petti on chesthe Adhi damage authundhaa..???
Bro... please answer....ah Socket ki 2 phases vasthe aah socket lo edaina applaince pedithey Adhi Damage authundhaa.....Like TV or AC plug pedithey Adhi damage authundhaa??
Mana intlo undedi single phase supply kada.. ikkada fail aina neutral kuda mana intiki sambadinchina neutral kanuka, ikkada socket ki rendu vipula appear aiyyedi mana intlo phase ee kada. Ante same phase socket ki rendu vipula vastundi..
Same phase socket yokka rendu points daggaraku vastundi kanuka, aa rendu points madya potential difference zero avutundi.. kabatti tv operate avvadu.
Inkoka sari video chudu.. neeku clear ga ardam avutundi..
All the best..
@@ElectricalEngineeringTelugu haa..Adhi ardam aindhi.....ma intlo stabilizer lo Output 2 sides phase vasthundhi and output indicater glow avadam ledu....andulo TV pedithe On avvadhu ...but 2 side phase valla internal ga emanna damange authundhaa TV lo....??
Bro oka doubt.. switch on cheyakundane anni sockets lo phase hole lo tester glow avuthundi.. enduku ala jaruguthundi
The reason might be found in the following video.
th-cam.com/video/0l8H5GPiHI4/w-d-xo.html
Watch the video for clarity
All the best siddeshwar prasad..
@@ElectricalEngineeringTelugu Thank you
Neutral not functioning
Sir commutation process sir please
Only neutral lo phase vaste problem enti bro
అన్ని ఫ్యాన్ tv బల్బ్ లో న్యూట్రల్ వైర్ ఎక్కడ cut అయినదో.. ఎలా తెలుసుకోవాలి...
@Electrical Engineering Telugu గారు మీ reply కి నా ధన్యవాదాలు...సర్ మీరు చెప్పినట్లుగా న్యూట్రల్ ని common గా ఇవ్వడం వల్ల కరెంట్ బిల్లు పెరిగే అవకాశం ఏమన్నా ఉంటుందా ఆన్నది మాత్రమే నా డౌట్ సర్....
చిన్న చిన్న load కి టీవీ, fan, bulb ఇలాంటి వాటికి న్యూట్రల్ ని common గా ఇవ్వడం ok అని మీ వివరణ వల్ల నాకు అర్థం అయ్యింది....
కానీ ఏసీ, fridje, geaser, ఐరన్ బాక్స్, పెద్ద load గల ఎక్కువ ampers కల వాటికి కూడా న్యూట్రల్ ని కూడా common గా ఇవ్వవచ్చా అన్నది మాత్రమే నా డౌట్ సర్..
( పొరపాటున కామన్ ని series అని వాడాను క్షమించాలి)
నేను electricitry మీ లాంటి వాళ్ళు పెట్టె వీడియో లు చూసి నేర్చుకుంటున్నాను...మీ అందరికి మరి ఒకసారి ధన్యవాదాలు
Very good Ramya siramdas Garu..
According to Indian Electricity rules
Mana loads ni manam rendu rakalu ga classify chestam . Avi
1) light and fan loads (light and fan sub circuit): ee sub circuit yokka rating 800 watts ki Minchakudadu.. corresponding ga manam wire ni choose chesukovali..
2) power loads (power sub circuit): ee sub circuit yokka rating 3000w minchakudadu.
Asalu ee rendu sub circuit ni mix cheyya kudadu..
Mana vullalo electricians ituvanti standards emi patinchukoru (vallaki teliyaka povachu)..
Alage inkoka mata mee intlo load (connected load kadu maximum demand) anedi meeru chose chesukunna service mains current carrying capacity ki Minchakudadu..
Mee number post cheyyandi .. we can didcuss over telephone too for greater clarity..
@@ElectricalEngineeringTelugu 9492188443 Raju Siramdas....
Sir మీ నెంబర్ కూడా దయచేసి ఇవ్వగలరు...
నా కోసం మీరు ఈ సమయం కేటాయించినందుకు నా ప్రత్యేక ధన్యవాదాలు
I have talked with you 3 days ago over telephone..
I think, I cleared all your doubts..
@@ElectricalEngineeringTelugu yes sir...Thank u once agin
How to fix this problem
You just check the neutral points (how neutral would be distributed from main distribution board, main distribution board also one of the main check points) at your home, where it has been disconnected, and connect it properly. Your problem is solved..
While doing any electrical work, make sure that electrical power must and should be isolated . That is after switching off the electrical power supply, you start any electrical work.
Make safety first, then start doing work.
N Kuda power supply vasthadhaaa
I can't understand what you are asking..
Bro same problem but Naku main off chesinappudu ila vastundi enduku reply bro
The Main might be the faulty..
Why because, when you switch off the main, both phase and neutral must be cut off. But in this case, as the main might be the faulty, it may cut off only neutral at mains, but the phase comes to the switch boards even though the main off. So you are getting both sides phase at your socket.
Now you switch off the main and remove the fuse after the mains
and check for the supply at your socket on the switch boards. You may not see the supply.
Even after removing the fuse, if you face the same problem, just let me know .. we will discuss over telephone too...
@@ElectricalEngineeringTelugu please any video suggetion for this problem please
What are you doing, where you faced the problem.. you may not found video suggestion for it. If it is due to faulty mains, faulty mains may not available readily. You just post your number here..
I think one of the socket connection is wrong bro
If neutral fails then why light will glow bro
You are telling that bulb will glow how it will glow with out circuit is closed
Video chusi comment pettu bro.. bavuntundi
Anna I have dought neutral fail aninappudu shock kottidda kottadda
Phase wire ni direct ga touche cheste tappakunda shock kodutundi...
You can watch below video for clarity
th-cam.com/video/0l8H5GPiHI4/w-d-xo.html
@@ElectricalEngineeringTeluguok ok ok ok bro ippudu ardam ayyindi and excellent explain bro
@@ElectricalEngineeringTelugu I have another dought manam bulb ki rendu vaipula phase connect cheste bulb veligidda?
And other dought is
Socket lo one connection swith nunchi tisukuntam inkokati neutral wires connect chestam avi change aite problem untunda?
Yaduku?
Modati prasnaku javabu:
Bulb ki 2 vaipula same phase iste kanuka Bulb velagadu..
Ala kakunda oka vaipu R-Phase, rendo vaipu Y-Phase Ala different phase lu iste ,
Aa bulb 230V rating bulb aite filment rali potundi..
Oka vela bulb 415v rating kanuka aite velugutundi..
2 va question ki javabu:
Phase anedi eppudu fuse, switch dwarane ivvali.. direct ga ivvakudadu..
Nenu previous ga pettina link aade.. okasari chudu..
Aina ikkada
Kuda link istunnanu.. okasari chudu..
th-cam.com/video/0l8H5GPiHI4/w-d-xo.html
Ans my question
What's your question...
Same problem bro but light velagatledu
Appudappudu matrame Alaa two holes lo power vastundi, problem emai untundi ?
Loose connection of neutral..
Just find the where the neutral is loose connected and fix it. Your problem will be solved.
@@ElectricalEngineeringTelugu sorry bro light velugutundi
Problem entante prathi socket lo switch off chesina neutral side power vastundi and Anni appliances baane Pani chestunnai
How can you tell you that is neutral side, that might be the phase side. You just check again if tester glows on both sides of socket, just let me know.
You may also check for this, the phase must be connected to switch, but some local electricians giving neutral to switch and phase to equipment directly which is wrong and very much danger too.
Thanks...
@@ElectricalEngineeringTelugu main fuse(current board) theesesaaka kuda neutral side power vastundi
@@ElectricalEngineeringTelugu fuse pettinapudu two sides vastundi bro
Sir pls explain how to solve it.
What man..
How to solve
You just identify where the neutral has been disconnected/broken, then fix it. Then problem solved.
Oka doubt ___
Ask me, what is your doibt.?
Maku oka roomlo.vastundi inkoka room lo ravatledu,
Sir namasthe...
నాకు ఒక డౌట్ ఉంది దయచేసి reply ఇవ్వగలరు...మీరు ఇచ్చిన సర్క్యూట్ లో L1. L2. L3 fan, tv line wire లాగానే న్యూట్రల్ wires ని కూడా 6 పాయింట్లకి విడిగా తీసుకొని 3 pin socket లో కలపడం ok నా అలా చేయడం వల్ల కరెంట్ బిల్లు తక్కువ వచ్చే అవకాశం ఉందా...లేకపోతే మీరు చెప్పిన విదంగానే neutral ని ప్రతి load కి series కలపడం బెటర్ అంటారా?...దయచేసి చెప్పగలరు...నేను yotube లో వీడియోలు చూసి house wiring గురించి నేర్చుకుంటున్నాను
Hi ramya siramdas garu..
Neutral ni series ga ivvaledu, parallel gane ichamu.. adenandi common ga icham..
Meeru anukunnatlu ga kuda cheyya vachu..
Endukante manaki 1-ph equipment operate avvalante phase and neutral rendu ivvali kada..
Meeru neutral ni separate ga ivvali anukunte oka common bus ni tisukoni Daniki electricity board nunchi vachina neutral ni connect Chesi, aa bus nunchi individual loads ki separate ichukovachu.. kani dani valla copper wire requirement (initial cost) perugutundi. So associated copper losses kuda perugutai kani taggav(ante current bill perugutundi kani taggadu). Common bus nunchi okkokka room( okkokka sub circuit) ki okkokka neutral wire ni alage okkokka phase (phase bus nunchi) wire ni distribute chesukonte manchidi ani na abiprayam. Dani valla trouble shooting, alage initial cost and losses point of view lo kuda optimum ga untundi..
@@ElectricalEngineeringTelugu మీ reply కి నా ధన్యవాదాలు...సర్ మీరు చెప్పినట్లుగా న్యూట్రల్ ని common ( పొరపాటున series అని వాడాను క్షమించాలి) ఇవ్వడం వల్ల కరెంట్ బిల్లు పెరిగే అవకాశం ఏమన్నా ఉంటుందా ఆన్నది మాత్రమే నా డౌట్ సర్....
చిన్న చిన్న load కి common గా ఇవ్వడం ok అని మీ వివరణ వల్ల నాకు అర్థం అయ్యింది....కానీ ఏసీ, fridje, geaser, ఐరన్ బాక్స్, పెద్ద load గల ఎక్కువ ampers కల వాటికి కూడా అలా ఇవ్వవచ్చా అన్నది మాత్రమే నా డౌట్ సర్..
నేను electricitry మీ లాంటి వాళ్ళు పెట్టె వీడియో లు చూసి నేర్చుకుంటున్నాను...మీ అందరికి మరి ఒకసారి ధన్యవాదాలు
thankk you sir
You are welcome teja..
Thanks bro
You are welcome damesh...