TRIANGULAR ECCENTRIC FOOTING

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 ธ.ค. 2024
  • Eccentric Footing, Economical Eccentric Footing, Triangular Eccentric footing, reinforcement details of eccentric footing, civil structural engineering discovery, practical details of eccentric footing
    Here, i will show you details of Triangular Eccentric Footings which is economical than strap beam footing.
    Contact
    www.devendrapotdar.com
    Email Id - dvp@devendrapotdar.com

ความคิดเห็น • 54

  • @huffaz_group
    @huffaz_group 3 ปีที่แล้ว +3

    It would have been great if you explained what "extra bending moment" this footing resists i.e how does this triangular section resists the moment

  • @anandgor4181
    @anandgor4181 11 หลายเดือนก่อน

    Extra bending bar information which very useful

  • @kannikagowda2905
    @kannikagowda2905 3 ปีที่แล้ว +2

    Hi .. please make a video of complete design of an eccentric footing.

  • @khasabkhb736
    @khasabkhb736 หลายเดือนก่อน

    Eccentric footing ka video banaye na sir kaise jali bandhte he eccentric footing beam BHI rahte hai kisi kisi me ek life video banaye pura details me eccentric footing ka

  • @IrfanShaikh-SE
    @IrfanShaikh-SE 3 ปีที่แล้ว

    Hello , How r u.
    Please make more videos like this in detail. I would be greatful if you make thess types of videos with detail explanation.

  • @sarthakmohapatra3738
    @sarthakmohapatra3738 4 ปีที่แล้ว +1

    Excellent video sir. Thnx a lot

  • @taysonwar8680
    @taysonwar8680 4 ปีที่แล้ว

    It's economical and money saving

  • @tejasvenom1952
    @tejasvenom1952 3 ปีที่แล้ว +1

    Hi sir... This video is really nice.. Same situation as in my case. Even I'm designing a G+2 Residential structure. Sir. Can you please tell me how to design for corner footings?

  • @manojkumar-qu8ml
    @manojkumar-qu8ml 3 ปีที่แล้ว

    May I know the how much load carrying capacity of footing decrease if beam or trapezoidal rcc not given

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 ปีที่แล้ว

    Good.

  • @ganeshkale5900
    @ganeshkale5900 4 ปีที่แล้ว

    👍👍👍Please explain two way eccentric with reinforce and concrete details

  • @gurvindersingh-if5te
    @gurvindersingh-if5te 3 ปีที่แล้ว

    Sir
    Please explain its design calculation how it will safe

  • @jaihind32949
    @jaihind32949 4 ปีที่แล้ว

    Very nice information.
    Thanks a lot

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 ปีที่แล้ว

    Please show the behaviiur of footing along with column.

  • @sasikumartherayil9620
    @sasikumartherayil9620 4 ปีที่แล้ว

    What are the forces on column.
    What is bearing capacity.
    Hiw is the pressure diagram.
    Why top steel is provided

  • @loksapps5455
    @loksapps5455 7 หลายเดือนก่อน

    How much depth required for G + 2 ?

  • @rudreshkamat1941
    @rudreshkamat1941 3 ปีที่แล้ว

    Can you share the design procedure, also pmax pmin .

  • @frsaj7396
    @frsaj7396 4 ปีที่แล้ว +1

    please shear with us how u calculate extra inclined bar height.
    another ques. u calculate footing two steps like 1st 600 mm and 2nd one 1075 mm. ples give me details

    • @civilstructuralengineering9272
      @civilstructuralengineering9272  4 ปีที่แล้ว +2

      hello, my RCC size along shorter span is 1675 mm from which I deduct depth of footing i.e. 600 mm so effective length = 1075 mm. & slope taken is 1:1 , so vertical height also 1075 mm

    • @frsaj7396
      @frsaj7396 4 ปีที่แล้ว +1

      @@civilstructuralengineering9272 if i take more or less than depth of footing its will be ok or not. please ans. me

    • @civilstructuralengineering9272
      @civilstructuralengineering9272  4 ปีที่แล้ว

      @@frsaj7396 no, it should be as described

  • @jadhavajay15
    @jadhavajay15 4 ปีที่แล้ว +1

    Plz shear Excel sheet design or what method u used

  • @APBEngr
    @APBEngr 4 ปีที่แล้ว +1

    How to design this kind of footing?

  • @MohammadIrfan-jd3pk
    @MohammadIrfan-jd3pk 4 ปีที่แล้ว +1

    What is the load on column for which this footing was designed?

    • @civilstructuralengineering9272
      @civilstructuralengineering9272  4 ปีที่แล้ว

      It's a G+2 structure. & Ultimate load of Column is 900 KN.

    • @thecivilboyverma1430
      @thecivilboyverma1430 4 ปีที่แล้ว

      th-cam.com/video/-UDrDZHLDz0/w-d-xo.html

    • @manojkumar-qu8ml
      @manojkumar-qu8ml 3 ปีที่แล้ว

      May I know the how much load carrying capacity of footing decrease if beam or trapezoidal rcc not given.

  • @gurvindersingh-if5te
    @gurvindersingh-if5te 4 ปีที่แล้ว

    Dear
    How in this footing uniform gross pressure occur or how gross pressure is less than safe bearing capacity of soil.if it does not certified this createria therotical it will settle so please explain it

  • @surajsurvase8519
    @surajsurvase8519 4 ปีที่แล้ว +1

    Aapka colum horizontal hai
    Jab column vertical aayga to ecentric footing kaisi aayegi

    • @civilstructuralengineering9272
      @civilstructuralengineering9272  4 ปีที่แล้ว +1

      Basic principle is same.We have to provide reinforcement to resist moment. Plz give us your mail ID, we will send details of vertical column eccentric footing.

    • @infanaik9892
      @infanaik9892 4 ปีที่แล้ว

      @@civilstructuralengineering9272 sir please send me also my mail id is ashutoshmnaik@gmail.com

  • @umashankarsingh1248
    @umashankarsingh1248 3 ปีที่แล้ว

    Please load this video with translate into the Hindi language. Thanks