Split AC Outdoor Wiring Diagram | Magnetic Contactor Wiring Connection in AC | Split & Window AC
ฝัง
- เผยแพร่เมื่อ 25 ส.ค. 2024
- Welcome to our TH-cam channel, where we bring you a comprehensive step-by-step guide on how to correctly wire the outdoor unit of a split air conditioning system. And i have explain how to install magnetic contactor in AC outdoor unit and window AC unit. If you're planning to install a split AC unit and want to ensure a hassle-free and safe setup, this video is perfect for you!
In this video, we will walk you through the entire process of wiring the outdoor unit of a split air conditioner. We will cover each step in detail, providing clear and easy-to-follow instructions to make the installation process a breeze, even for beginners.
Here's what you'll learn in this video:
Introduction to Split AC Outdoor Unit: We'll start by explaining the components of the outdoor unit and their functions.
Electrical Requirements: Understanding the electrical requirements is crucial for a successful installation. We'll explain the power supply specifications and any additional considerations needed.
Wiring the Outdoor Unit: The main part of this video will demonstrate the actual wiring process step-by-step. We'll guide you through connecting power cables, control wires, and safety features, ensuring everything is done accurately.
Installing a magnetic contactor in an AC outdoor unit is an important part of the air conditioning system's electrical setup. The contactor is a switch that controls the flow of electricity to the compressor and condenser fan motor. Here's a step-by-step guide on how to install a magnetic contactor in an AC outdoor unit:
Note: Before attempting any electrical work, make sure the power supply to the AC unit is turned off to avoid any accidents. If you're not confident in your electrical skills, it's best to seek the assistance of a licensed HVAC technician.
Install the Magnetic Contactor: Mount the magnetic contactor on a suitable surface inside the outdoor unit using the mounting screws.
Wiring the Magnetic Contactor:
Connect one end of the power supply wire (usually the black or brown wire) to one of the main terminals of the contactor.
Take another power supply wire (usually the red or orange wire) and connect it to the other main terminal of the contactor.
Attach the free end of the black/brown wire back to the original circuit connection point in the outdoor unit.
Connect the other end of the red/orange wire to the other original circuit connection point.
Connect Control Wires:
Connect one of the control wires to the coil terminal marked "A1" on the contactor.
Attach the other control wire to the coil terminal marked "A2" on the contactor.
Insulate and Secure Wires: Use electrical tape to insulate all wire connections and prevent any accidental contact with other components. Make sure all wires are properly secured to avoid interference with moving parts.
Check the Wiring: Double-check all connections to ensure they are correctly wired and firmly attached.
Close the Access Panel: Put the access panel back on the outdoor unit and secure it in place.
Power On: Turn on the power supply to the AC unit by switching on the circuit breaker or plugging it back into the power source.
If everything is working as expected, you have successfully installed the magnetic contactor in the AC outdoor unit. If you encounter any issues or are unsure about any step, it's best to seek professional assistance. Safety is of utmost importance when working with electrical components.
If you find this video helpful, don't forget to like and subscribe to our channel for more informative content on air conditioning, home improvement, and DIY projects. Hit the notification bell so you won't miss any future updates!
..
Your Queries:-
Split AC Installation
Outdoor Unit Wiring
AC Wiring Diagram
AC Installation Guide
HVAC Tutorial
DIY Air Conditioning
Air Conditioner Wiring
Air Conditioning Installation
Outdoor Unit Setup
AC Maintenance
AC Repair
Home Improvement
Electrical Wiring
Cooling System
DIY Projects
Step By Step Guide
Air Conditioner Tips
HVAC Maintenance
split ac wiring diagram
split ac wiring
split ac wiring diagram indoor outdoor single phase
ac wiring diagram
ac wiring
split ac wiring diagram
split ac outdoor unit wiring digram
indoor to outdoor wiring
window ac wiring diagram
split ac wiring connection
split ac outdoor wiring diagram
window ac wiring diagram pdf
split ac wiring in hindi
split ac
ac outdoor wiring
split ac outdoor wiring
..
Get More Great Videos - 🔔Subscribe →MY CHANNEL
My Other Videos links..
..
Reverse Forward Motor Starter Wiring | forward reverse power and control circuit diagram in urdu.
• Reverse Forward Motor ...
..
Contactor Holding Circuit /Practically Contactor Connection with NO and NC Switches in Hindi.
• Contactor Holding Circ...
..
How to Interlocking in Electrical System ?What is Interlocking? Double interlocking with push button
• How to Interlocking in...
..
#SplitACInstallation
#OutdoorUnitWiring
#ACWiringDiagram
#ACInstallationGuide
#onlineelectricwork
Outstanding explain sir❤
Good
goor bro
Outstanding explanation
thanks
Very good thankyou gues welcome
@@jollyscaria1922 thanks
Great sir
Zazak allah bahut acha laga hai
❤❤❤❤❤❤تمام
Shukriya Bhai ❤❤
Jazak Allah ❤❤❤❤
Nice video make❤
Tq sir
Thanks br
Nice...
Good work dear
thanks
Please making this shema for inverter
Is ko direct chalana ho kia kare gay ,, Neotal phase Dena ho to
is ko direct chalana ho to neutral or phase sy direct magnet contactor ki coil ko ON krwayen gy
❤❤❤❤❤❤
❤
nice video liken Bhai jes AC ke man outdor ma ho indoor ke us ke wring pa asa he bna da video
ok
Bhi ya waley app hum mobil par be chala saktay hey ya ni
No idea
👍
Hi,
I have a query regarding the selec vprd2m voltage protection relay that I recently purchased. My house has a single-phase 2-pole setup, and I intend to use the vprd2m relay with it. However, the relay's output is 5 amps, and my house has a mix of resistive and inductive loads ranging from 5 amps to 15 amps.
To handle the varying load, I am considering using a 2-pole or 3-pole 25 amp contactor in conjunction with the vprd2m relay. This should help manage the load more effectively. Currently, I'm facing an issue where the vprd2m relay becomes excessively hot whenever my house appliances' load increases beyond 5 amps, especially when it reaches 12+ amps.
Could you kindly suggest a suitable contactor that can handle loads from 5+ amps up to 15 amps for my 110v - 300v, 20 - 25 amp resistive + inductive load setup? I'm looking for an affordable yet reliable option that won't compromise on safety and performance.
Your expert advice on this matter would be greatly appreciated. Thank you in advance for your help!
use 60 amps magnetic contactor with protection device and connect all load through contactor.
protection device will operate the contactor only and all load on magnetic contactor.
@@onlineelectricwork could you please suggest schiender model number, what about coil voltage ..
@@onlineelectricwork
Vprd2m specification / datasheet are as follow.
Vprd2m voltage monitor realy's Operating voltage might contactor coil voltage ( vprd2m Operating Voltage 127 to 288V AC)
How much contactor's coil voltage I supposed to choose. ?
Type of Output 2 C/O (DPDT)
Output Specifications
No. of Relays 1
Contact Rating
NO, NC : 5A@250V
Auxiliary Supply Specifications
Supply Voltage Self Powered
Nominal Input Voltage, Un 230V AC (L - N),
Operating Voltage 127 to 288V AC (L - N),
VA Rating 5VA max,
Frequency 48 - 63Hz
@@freedom_fighter- anyone schneider or ABB model.if you have use 110 voltage for single phase power supply so contactor coil voltage shall be 110v otherwise 220v
@@freedom_fighter- contactor coil voltage =220v
Sir dc inverter mein bhi capacitor hota h?
capacitor to hota hy lekin kit k ander hi built-in hota hy
@@onlineelectricwork mera kenwood ac e comfort pro ampere drop nahe krta kia waja ho sakti h?
eye bhai, 3 phase electric raiting diagram, chahiye. Indor,and outdor,,,pliz ripely bhai❤❤❤
ok me koshish kron ga
❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤🎉🎉🎉🎉🎉🎉
Campressr ke sath me jo juda huaa hai uska nam kya hai
magnetic contactor
Sir outdoor thodi der chlta bad me off ho jata ha please sugg
1=outdoor fan ki speed ko check kren km ho gai hy to capacitor check kren.
2=outdoor ka condunser check kren or sfai kren
Good working
Wrong