Please read and answer so that we can make our normal inverter ac into hybrid solar ac Inverter air conditioner nowadays are running smoothly on solar power provided their outdoor and indoor fan is also dc, as some brands install ac induction fan in outdoor unit and make it useless, In panasonic 5 star inverter ac compressor indoor fan outdoor fan swing motor all are dc and 6*550 solar panels run inverter ac whole day 9 pm to 3 pm But in cloudy days there may be some fluctuations To address this Amp fluctuation issue a bridge rectifier circuit can be used in air conditioner plug box on the one end of circuit we will give 220 v ac current and on another end of circuit 220v rectified dc will be produced by bridge rectifier with +v and -v polarity now connect +v of solar panel to + of bridge rectifier and -v of solar panel to -v of bridge rectifier, feedback current can be protected using diods so that solar current not go in ac line and ac rectified dc current dont go back into dc solar line diods should be connected before connecting + + and - - together will do this job, for this we need 6 panels of 550 watts and total voltage should be a little higher than grid supply 6 panels will give around 280 volt dc current while grid usually provides 250 volts now after using this bridge rectifier air conditioner will draw current from solar panel if sufficient ampere not available in solar supply it will take remaining amps from grid we are not touching anything inside air conditioner, this circuit will make our air conditioner an ongrid or hybrid air conditioner which will primarily run on solar power if solar power is available if solar power is not sufficient it will take power from grid no separate connection needed in night time and in case of grid outage and sun availability air conditioner will keep running till sufficient power is generated through solar panels Point to be noted 👉 in above post I used term 220v rectified dc for easier understanding but in reality 220v ac rectified gives peak voltage around 311 volt dc hence to counter this situation and maintain voltage compatibility easiest way to use a 220v to 110v converter on ac current line then do the bridge rectification and we will get around 155 voltage dc best voltage for our system now 4x550watt solar panels will produce around 200 to 190 volt dc bridge rectifier will produce 155 v dc now solar panels output and bridge rectifier output to be connected in parallel with diods protection since device will draw current from high voltage source first it will run on solar panel if solar panel voltage drops or current drops it will take remaining power from bridge rectifier, in the morning time solar panel will provide less amps and and our system will take remaining required amps from bridge rectifier this hybrid system will prevent fluctuations throughout the day and utilise solar+grid in day time and only grid in night time
Seakd comprssir teeminal c.s and Rare udenttidiedby measuringtheresistance ohms bet ween ber qeenthe terninals using multimeraror clampmetrtheresisttanceif ruing windingis lowwhile thatof starting widingis gigh whenthw multimetr poeds are conneacted to terinals r c resistance of ruing winding orthe lowestreistance ia indicated when the pords are coneactedto terminals Rand s totalreistance of bothwiding is indicatedwentermuals termial c and s are co tactedto mwtrristens startigqundoifhifh low r c cs poted
3 phase compressor l1 l2 l3 terminal remove ho gya ho to kaise pata karenge ki Kaun sa terminal l1 l2 l3 hai R-L1 , Y-L2, B-L3 ye wiring sequence hai Abhi RYB ko isi sequence me connection dena hota hai nahi to compressor high noise , homming karta hai
Bhai inverter AC ke outdoor mein jo bhi system Laga hota hai uske bare mein details mein Bata do ki uski wiring kaise karte hain aur har EK part ko check karna bata do
Very nice information sir ek video ap ac choking ke upar bhi bana do ki ac ke pure macenical system me kahi bhi choking ho cleamp meter or apne experience ke mutabik kaese pata kare ki ac me chok hai ❤❤❤❤
ac choking se related video upload kar di hai ja kar ke aap dekh sakte hain ummeed karta hoon aap ko is video se jaroor kuchh na kuchh sikhne ko melega💚 video link:-th-cam.com/video/SZWBYxI57qA/w-d-xo.html video link part 2 :-th-cam.com/video/O3KSp6BYd0Q/w-d-xo.htmlsi=5kehxcwepaFJ5OnC
veeray kai sare reason ho sakte aap in sabhi pointon ko step by step check kar sakte hain . (1). voltage under ya over hona ( rated volt se) (2). capacitor weak hona (3). proper condensing na hona ( condensor coil chocked , condensor fan weak ) (4). refrigerant over charge (5). chocking hona (6). compressor oil over heat ya kam hona (7). compressor faulty.
Bhai jis modal number me last me kce rahega usme R407c gas dale gi kis leye policter oil hi our jis model numbere last me kc rahega toh usme R22 dal sakte hi isme mineral oil hota hai toh oil number sticker per likha raheta hai usko dekh ker dalna padega
saud bhai agar aapko compressor ka ton pata karna hai to aap model no aur LRA se bhi pata kar sakte hain LRA se pata karne ke liye . takreeben 36 LRA ka 1 ton hota hai model har company ka alag alag hota hai to aap ko thoda sa samajhna padega model se ton kaise pata kare.th-cam.com/video/MIZAGPA2iE0/w-d-xo.htmlsi=TCRNfAHlZzOPzwlD
koi nahi bro agar aap main koi bhi kaam karne ka junoon hai to aap ko koi nahi rok sakta fir chahe aap ek engineer banna chahen ya fir ek blogger . aap mehnat karte rahiye . sikhte rahiye. aur improve karte rahiye god bless you🤝❤️
Will the compressor of a refrigerator go bad if it is run without any load, such as being empty and without connecting any pipe or loading any gas? If it does go bad, what is the reason for this occurrence?
Bhai mien NY new campresr instal Kiya pressure aur sab cheez theek tha Lekin gass add krny k time 10/15 mint theek chlaa us k bad preshr chor diya to kya msla ho skta Hy plz btaye ga zror
Ik bar gas Nikal k dubara adhy gnty bad chlaya phir 10 mint sae chla phir wesy hi ho gya is ka neechy waal to ni bnd Lekin mien NY fitar lghny k bad chak Kiya tha preshr sae AA rha tha
hello . 🤝🙏 .ex.1 cooling capacity of 1.5 ton = 5275 W of power. If the supply voltage is around 220 V AC, then the running current will be 1510/220 = 6.9 A. ex.2. Capacity Current (AMP) Breaker size 0.75 ton 5~6Amp 16 Amp 1.0 ton 6~7Amp 20 Amp 1.5 ton 8~10Amp 32Amp 2 ton 15~16Amp 40Amp NOTE;- ye ek example hai koi fix amp.nahi hota hai . han ye jaroor hai ki "lagbhag " itna hi amp compressor leta hai (kyonki ye depend karta hai ki aap ke system main kon sa compressor laga hai , kon sa refrigerant use huwa hai , kitne star ka hai 3 star ya 5 star ....aur bhi bahut sari baten hai jiski wajah se amp. main thoda sa diffrent ho sakta hai.
Hello Sar meri detan ki aisi hai aur usmein jo compressor hai vah load jyada le raha hai light jyada Jaise chalti hai aisi to load jyada leta hai sari light kam Ho jaati hai aur FIR cut maar deta hai to Kiya problem hai sar
agar compressor main side glaas diya huwa hai to aap use dekh kar pata kar sakte ho ki kitna oil compressor main hai jesa ki kuchh compressor main hota hai lekin agar aap aise compressor main oil check karna chahte ho jisme side glass nahi hai to aap compressor ka sara oil bahar nikal karke check kar sakte hain aur agar oil kam hai to oil add karke oil poora kar len . bas yahi ek tarika hai oil check karne ka . ummed karta hoon aapko samaj main aa gaya hoga ..🤝❤️
Aap mere channel se jude rahiyega aapko aisi hi knowledgeble videos milti rahegi❤️🙏 Aapko jis bhi topic par video chahiye aap hame comment karke bata sakte hain I am from Lucknow 🤝
Ji han aise bhi kar sakte hain aur teen zero laga lenge to bhi kar sakte hain koi galat nahi hai copleland ke jo model hote hain wo do type main hote hain ek “K” main aur ek “M” main ( ZR125K,ZR19M) ab yahan par do model type hain ek K aur ek M To ham K wale main teen zero is wajah se lagayenge kyonki K jo yahan par diya gaya hai wo hajar ko represent kar raha hai is liye koi galat nahi hai aur M ke bare main aur maloom karna hai to watch this video 👉th-cam.com/video/MIZAGPA2iE0/w-d-xo.htmlsi=dKJ4lYqaEbNmy7g0
Reley refrigerator ya deep freezer ke compressor main lagta hai Ye compressor Air condition ka hai iske compressor main jyadatar capacitor hi laga hota hai( PSC type ) Pahle aate they aise compressor jo ki hermetic type ke hote they jinme reley lagi hoti thi jisko CSR type connection karna hota tha Abhi rotary type ke compressor main sirf PSC type connection hote hain… Thanks for feedback ❤️
💥please check description & follow this ( 🔺👉) as request .
Gajab
doston air conditioner se related agar aapka koi bhi doubt ho to aap comment karke bata sakte hain...🙏🔔❤
Please read and answer so that we can make our normal inverter ac into hybrid solar ac
Inverter air conditioner nowadays are running smoothly on solar power provided their outdoor and indoor fan is also dc, as some brands install ac induction fan in outdoor unit and make it useless,
In panasonic 5 star inverter ac compressor indoor fan outdoor fan swing motor all are dc and 6*550 solar panels run inverter ac whole day 9 pm to 3 pm
But in cloudy days there may be some fluctuations
To address this Amp fluctuation issue a bridge rectifier circuit can be used in air conditioner plug box on the one end of circuit we will give 220 v ac current and on another end of circuit 220v rectified dc will be produced by bridge rectifier with +v and -v polarity now connect +v of solar panel to + of bridge rectifier and -v of solar panel to -v of bridge rectifier, feedback current can be protected using diods so that solar current not go in ac line and ac rectified dc current dont go back into dc solar line diods should be connected before connecting + + and - - together will do this job, for this we need 6 panels of 550 watts and total voltage should be a little higher than grid supply
6 panels will give around 280 volt dc current while grid usually provides 250 volts
now after using this bridge rectifier air conditioner will draw current from solar panel if sufficient ampere not available in solar supply it will take remaining amps from grid we are not touching anything inside air conditioner, this circuit will make our air conditioner an ongrid or hybrid air conditioner which will primarily run on solar power if solar power is available if solar power is not sufficient it will take power from grid no separate connection needed in night time and in case of grid outage and sun availability air conditioner will keep running till sufficient power is generated through solar panels
Point to be noted 👉
in above post I used term 220v rectified dc for easier understanding but in reality 220v ac rectified gives peak voltage around 311 volt dc hence to counter this situation and maintain voltage compatibility easiest way to use a 220v to 110v converter on ac current line then do the bridge rectification and we will get around 155 voltage dc best voltage for our system
now 4x550watt solar panels will produce around 200 to 190 volt dc bridge rectifier will produce 155 v dc now solar panels output and bridge rectifier output to be connected in parallel with diods protection since device will draw current from high voltage source first it will run on solar panel if solar panel voltage drops or current drops it will take remaining power from bridge rectifier,
in the morning time solar panel will provide less amps and and our system will take remaining required amps from bridge rectifier this hybrid system will prevent fluctuations throughout the day and utilise solar+grid in day time and only grid in night time
Seakd comprssir teeminal c.s and Rare udenttidiedby measuringtheresistance ohms bet ween ber qeenthe terninals using multimeraror clampmetrtheresisttanceif ruing windingis lowwhile thatof starting widingis gigh whenthw multimetr poeds are conneacted to terinals r c resistance of ruing winding orthe lowestreistance ia indicated when the pords are coneactedto terminals Rand s totalreistance of bothwiding is indicatedwentermuals termial c and s are co tactedto mwtrristens startigqundoifhifh low r c cs poted
3 phase compressor l1 l2 l3 terminal remove ho gya ho to kaise pata karenge ki Kaun sa terminal l1 l2 l3 hai
R-L1 , Y-L2, B-L3 ye wiring sequence hai
Abhi RYB ko isi sequence me connection dena hota hai nahi to compressor high noise , homming karta hai
Bahut badiya bhai bahut achcha laga apke samjhane ka tarika
Sahi hai Boos good job
زبردست 👍👍👍 ماشاءاللہ ❤❤❤ بہت اچھا زبردست بہت عمدہ 👍♥️♥️🌹🌹🌹🥀🌹🥀
Buhut accha tarika hai shamjane ka sir
Khoob kiaa baat hai teacher ho app jaisa
Very useful video
Aap ka samja na bahut acha kisi naya elec ko samaj ahayega bahut bahut thank you ❤❤
Apka tareeka bahut zyada achha hai samjhane ka
Good job nice information
Bhut badia sa samjhiya ji
😍❤️🔔.
Bahut Achcha se kam Sikha raha hai
🤝🤲😍
very nice useful video bhai shukriya
Nice 👍 masaallah
Masah Allah
Aap ne buhat accha tech Kiya
Allah aap ko traqqi ata farmaye
🤲💚🤝
Gajab bhai
Thanks bro ❤
Good work ❤❤
Good 😊
Bahut badhiya samjhate hai sir
Thank you so much for your kind words! I'm glad you find my explanations helpful.
Very good good good information. Sir
So nice of you
Good 👍
Tq so much bhai
Mujhe kam aata h fir bhi maine aapki video dekhi ustad ho to aapki trh
love you brother 🤝 💚
Thank you
Nice
❤
Good explanation
Thank you for your feedback!
Ma Sha Allah 🥰
ماشاء اللّٰہ
Sirji, u r a good teacher 😊
Good 👍 sir
So nice
Maasha Allah ❤
❤ very professional
Very nice information...thnx a lot
Great sir
Supar
Wa Boos
Sir g ap Great Hain....
it’s my pleasure 🤝💚
Good brother
Like 1k ho gaya vai
We appreciate each and every like we get!👍🏻🎁
Masaallah ❤
❤❤❤❤so nice ❤
Bhai inverter AC ke outdoor mein jo bhi system Laga hota hai uske bare mein details mein Bata do ki uski wiring kaise karte hain aur har EK part ko check karna bata do
💯💯💯
Very nice information sir ek video ap ac choking ke upar bhi bana do ki ac ke pure macenical system me kahi bhi choking ho cleamp meter or apne experience ke mutabik kaese pata kare ki ac me chok hai ❤❤❤❤
done....
ac choking se related video upload kar di hai ja kar ke aap dekh sakte hain
ummeed karta hoon aap ko is video se jaroor kuchh na kuchh sikhne ko melega💚
video link:-th-cam.com/video/SZWBYxI57qA/w-d-xo.html
video link part 2 :-th-cam.com/video/O3KSp6BYd0Q/w-d-xo.htmlsi=5kehxcwepaFJ5OnC
Thanks sir
❤❤❤❤❤
❤❤❤❤❤❤
❤👍
Veer ji. Lloyd ka one ton window AC compressor overheating problem Hai meter per reading 6:24 aa rha Hai Kya Karen
veeray kai sare reason ho sakte aap in sabhi pointon ko step by step check kar sakte hain .
(1). voltage under ya over hona ( rated volt se)
(2). capacitor weak hona
(3). proper condensing na hona ( condensor coil chocked , condensor fan weak )
(4). refrigerant over charge
(5). chocking hona
(6). compressor oil over heat ya kam hona
(7). compressor faulty.
Thanks
Welcome💚
Sir compressor ka overload ka number k bara ma btain ka kis nunmber ha ha
done..✅
Good🇹🇷🇺🇸
💚🇸🇦
Sticker ka jo likha wa mitjayega to keise check karenge scorl compressor ke liye 3ph kitna ton Hain
bahut hi accha sawal hai bhai aapka ye problem aksar technician bhaiyon ko hoti hai ispar ek video aane wali hai bahut jald…⏰
Bhai jis modal number me last me kce rahega usme R407c gas dale gi kis leye policter oil hi our jis model numbere last me kc rahega toh usme R22 dal sakte hi isme mineral oil hota hai toh oil number sticker per likha raheta hai usko dekh ker dalna padega
Ser common ke saath running lagta hai capacitor men
Capacitor par Running aur starting lagega
Common par direct ek supply jayegi(N)
@@thetechhvac thank you ser
❤
💚
Compressor low amp per kisay chalai?
❤❤❤❤❤👍👍👍👍👍👍💯💯💯💯
Compressor short, Kota
Sar rotary comp ka kese pata kare ke kitne tr ka he
saud bhai agar aapko compressor ka ton pata karna hai to aap model no aur LRA se bhi pata kar sakte hain
LRA se pata karne ke liye . takreeben 36 LRA ka 1 ton hota hai
model har company ka alag alag hota hai to aap ko thoda sa samajhna padega
model se ton kaise pata kare.th-cam.com/video/MIZAGPA2iE0/w-d-xo.htmlsi=TCRNfAHlZzOPzwlD
Agr aisa koi pahle samjaya hota to aaj mai AC ka engineer hota 😢
koi nahi bro agar aap main koi bhi kaam karne ka junoon hai to aap ko koi nahi rok sakta
fir chahe aap ek engineer banna chahen ya fir ek blogger . aap mehnat karte rahiye . sikhte rahiye. aur improve karte rahiye
god bless you🤝❤️
Thank you ❤ and the best part of this video is the name Ahmad,😂😂😂😂 it's mine name
😂Accha ji
Will the compressor of a refrigerator go bad if it is run without any load, such as being empty and without connecting any pipe or loading any gas? If it does go bad, what is the reason for this occurrence?
Yes! If it runs for a long time without gas. Because the compressor is designed to compress only vapor refrigerant ( not AIR , VACCUME etc..)
Bhai mien NY new campresr instal Kiya pressure aur sab cheez theek tha Lekin gass add krny k time 10/15 mint theek chlaa us k bad preshr chor diya to kya msla ho skta Hy plz btaye ga zror
kis type ka ac hai aur compressor kis type
ka ( single phase ,three phase , rotary , scroll…) please full detail den.
Bhai 3ph Hy aur scroll type hy
Ik bar gas Nikal k dubara adhy gnty bad chlaya phir 10 mint sae chla phir wesy hi ho gya is ka neechy waal to ni bnd Lekin mien NY fitar lghny k bad chak Kiya tha preshr sae AA rha tha
ye mera whatsapp no hai +917897686268
agar kahin se chocking hogi jaise exp. valve , orifice , capplery dryer filter to bhi ye problem aayega aise kai sare reason ho sakte hain
Hello sir. Good evening
How much max ampere is allowed for 1.5 TR and 2 TR ac compressor for a healthy running otherwise it will be faulty??
hello . 🤝🙏 .ex.1
cooling capacity of 1.5 ton = 5275 W of power. If the supply voltage is
around 220 V AC, then the running current will be 1510/220 = 6.9 A.
ex.2.
Capacity Current (AMP) Breaker size
0.75 ton 5~6Amp 16 Amp
1.0 ton 6~7Amp 20 Amp
1.5 ton 8~10Amp 32Amp
2 ton 15~16Amp 40Amp
NOTE;- ye ek example hai koi fix amp.nahi hota hai .
han ye jaroor hai ki "lagbhag " itna hi amp compressor leta hai (kyonki ye depend karta hai ki aap ke system main kon sa compressor laga hai , kon sa refrigerant use huwa hai , kitne star ka hai 3 star ya 5 star ....aur bhi bahut sari baten hai jiski wajah se amp. main thoda sa diffrent ho sakta hai.
Aap galat bata rahe hai
1.5 ton AC me 6ya7A so hoga
@@parvezkhanparvezkhan5477 aap se request 🙏hai aap dobara comment dyan se padhe aap ko poori baat samajh main aa jayegi .
Compressor ka 3 terminal continue aata h.3 terminal ke saath body pe touch kiya continue nhi dekhta h.ky reason h compressor nhi chalta h.new capactior lagaya
kabhi kabhi compressor jaam ho jaate hain jiski wajah se sab kuchh ok hone ke baad bhi compressor on nahi hota hai
Hello Sar meri detan ki aisi hai aur usmein jo compressor hai vah load jyada le raha hai light jyada Jaise chalti hai aisi to load jyada leta hai sari light kam Ho jaati hai aur FIR cut maar deta hai to
Kiya problem hai sar
Oil ka nhi bataya bhai apne kaise pta kare kitna oil hai compressor mai
bhai aap ye video dekh len is video main poori information hai. th-cam.com/video/kTvW6hPmYbA/w-d-xo.htmlsi=4n1gXpHVrt27x41V
Kaha btaye bhai oil ka
agar compressor main side glaas diya huwa hai to aap use dekh kar pata kar sakte ho ki kitna oil compressor main hai jesa ki kuchh compressor main hota hai lekin agar aap aise compressor main oil check karna chahte ho jisme side glass nahi hai to aap compressor ka sara oil bahar nikal karke check kar sakte hain aur agar oil kam hai to oil add karke oil poora kar len .
bas yahi ek tarika hai oil check karne ka .
ummed karta hoon aapko samaj main aa gaya hoga ..🤝❤️
@@thetechhvac universal pcb indoor wiring p ek video chahiye
@@AbdulAlim-tg3xr bilkul ji jaroor banayenge...❤
Hello sir i want to learn refrigerator and ac work please could you tech me sir i am from Hyderabad sir😊
Aap mere channel se jude rahiyega aapko aisi hi knowledgeble videos milti rahegi❤️🙏
Aapko jis bhi topic par video chahiye aap hame comment karke bata sakte hain
I am from Lucknow 🤝
Sar showing wrong common direct go to life connection running is neutral starting is line I am right tissing me please
please dobara bata sakte hain main aapka ka massage samajh nahi paya🙏
Sir HVAC ka pdf kha milega
online amazon se buy kar len .
Bahi apka Jo video acha laga magar apne Jo calutae Kiya o galth usme zr compress 🗜️ 125÷12= 10.4 are ok usme 12ka sath 00 kohi zarvath nahi
Ji han aise bhi kar sakte hain aur teen zero laga lenge to bhi kar sakte hain koi galat nahi hai copleland ke jo model hote hain wo do type main hote hain ek “K” main aur ek “M” main ( ZR125K,ZR19M) ab yahan par do model type hain ek K aur ek M To ham K wale main teen zero is wajah se lagayenge kyonki K jo yahan par diya gaya hai wo hajar ko represent kar raha hai is liye koi galat nahi hai aur M ke bare main aur maloom karna hai to watch this video 👉th-cam.com/video/MIZAGPA2iE0/w-d-xo.htmlsi=dKJ4lYqaEbNmy7g0
Hi sir whay you video new
th-cam.com/video/8ex36oVoaAo/w-d-xo.htmlsi=06wliIm62sHejYOX
Mai apke pass kam karna chahata hu
bhai mere miter me contati hold nahi re rahi har baar alag aa rahi hai
shayad meter ki prob sahi se nahi lagi hongi.
ya fir us jagah par carbon jama hoga ...
aapne C par N wala wire Laga Diya or R Line to glat hai yeah C pr line or R par Newton
aisa koi fix nahi hai AC (alternative current) voltage main
par aapke suggestion ki main respect karta hoon✅💚
Hermetic matlab purana Nahin Hai hermetic matlab sealed Jo compresser use karte hain ham log Vahi Shield hai
Bilkul sahi kaha aap ne lekin yahan main “purana” is wajah se bola hon ki ye “model purana“ hai🤝
Ya 1.5 ton ha bhi
125+000=125000
125000%12000=10.41-1 =9.41
2 phase nahi Single phase hai
agar mere pass 60 HZ ki supply ho to ?
phase to phase 230 volt banta ho to aap kya kahoge ?. ( kuchh country main is type ki power supply hoti hai )
Really nhi lagya
Reley refrigerator ya deep freezer ke compressor main lagta hai
Ye compressor Air condition ka hai iske compressor main jyadatar capacitor hi laga hota hai( PSC type )
Pahle aate they aise compressor jo ki hermetic type ke hote they jinme reley lagi hoti thi jisko CSR type connection karna hota tha
Abhi rotary type ke compressor main sirf PSC type connection hote hain…
Thanks for feedback ❤️