Sir aap kitna accha batate hai. Mai aapse door rahata hu, or ek anadi mistri hu, bus jitna Gyan hai utna kaam kr deta hu. Kya aap distance cource krate hai. Online etc.
Sar bahut acche se samjhate Hain isliye cal main a raha hun aapke pass aapka number chalu rakhna band mat Karna sar jab main call Karen to receive karna jarur sar Nahin to ham bhatkate rahenge vahi
Sir namskar sir 1swal hai ager ham r32gas a c main Charing gej k hisab se kar te hai jese r32 ka back 115.120 rehta hai to wehat k hisab se gas kam dalti hai ager wehat k hisab se gas dalte hai 800gr900gr jo outdoor par di hoti hai to back presar jyada ho jata hai 145.150 k pas chla jata hai
Sir ji inverter ac 1.5 tan ka hai to uska ampers 7-11 agar lee raha hai to uska gas ok hai. Agar 7 ampers se kam lee raha hai to uska gas kam hai agar 11 ampers se jada lee raha hai to uska condensed chok hai apne students ko achhe se bataiye guru ji. Aap se hath jod 🙏🙏🙏 ke binti hai
कोई भी फ्रिऑन गॅस पृथ्वीके ओझोन लेअरको हानिकारक होता है । ओझोन लेयर के कमी के कारण सुरजसे आनेवाली किरणोसे स्किन कॅन्सर होता है । और पृथ्वीका तापमान बढता है ।
Sir urban clap me humlog ko ye btaya hai ki amp5.75 se 9 amp me fluctuate hona chaiye agar gas puri hai to but gas charging ke baad sirf aapka4 amp aaya Kyu?
Are Sar Mujhe Galiyan dene per majbur mat karo aap ne 2:33 is ka Aage ka video cut Kar Diya pahle Sawal to clear karna tha key compressor ko kaise check Karenge Jaane Do main jawab de deta hun clamp metre se check Karenge compressor chalu hai ya band
Sir ji maine 2 ton ke ac me r32 gas charge kiya hai discharge line thnda ho rha hai magar suction line funda nahi ho raha Gas running pressure 130 pis dikha rha hai Our me seam 2 ac charge kiya hai 2 no milakr 1300 grm gas lagi hai to kya problem hua hoga pls bataye
Sir ji aap ke students keval sticker dekh kar hi gas dange jaha sticker nahi rahega vaha chod ke bhag jayenge log. Standing pressure check kar ke nahi dal payenge log 😂😂😂😂
Sir you are the Best Teacher on the world for me
From Pakistan
Sir Thank you so much apki videos dekh dekh kar mera Ac teachnicain main selection ho gaya saudi arabia ke liye salry bhi achhi hai
Kitni salary hai
😅
Kitani selry hai
Hello bhai hame bhi le chalo
Jhut kyu bol rahe ho
Very good class sir and very good student ❤ love u from u.p❤ and very very very good teacher❤
Sir aap kitna achhe se batate ho dil khush ho jata hai ❤
Sir aap bahut badhiya pdata hai 🎉🎉🎉🎉🎉🎉🎉🎉🎉🎉
Best way of doing work
Sir ji thankyou very much for your class related in AC i like so much 😂 please keep going so many videos in the topic
Sir your explanation is very good and easy
Good I am from Pakistan from Haier company brother
Sir aap bahut achhi video banate ho 😊
Outstanding explanation
I like these videos but i cannt understant your language i speak english and arabic❤
Assalamolekum me jharkhandse
अच्छा है धनवाड़ी
Sir aap kitna accha batate hai. Mai aapse door rahata hu, or ek anadi mistri hu, bus jitna Gyan hai utna kaam kr deta hu. Kya aap distance cource krate hai. Online etc.
Yahan log jo likh bhi nahi paate wo bhi technician bankar jaate hai ye samjhne par jyada depend karta hai
Kha me office hai bhai
@@SonuKumar-kw3zfu.p Aazamgarh mahrajganj me institute hai
Veri nice information❤
Sir very good information
Good brother 😎
Super
मेरे ac का outdoor कम गर्म हवा देता है
Indor भी cooling कम देता है क्या कमी हो सकती है
Apka video content acha hai bhai,, ye btaiye inverter comprssor speed nahi pakadta to iska kya solution hai
Gas kam ya jadi hogi
Ac pcb problem hogi
@@kareemtechnicalmind8172 aacha ,, koi sensor issue to nahi ho sakta,kis sensor ko check kiya jae first
Please reply any body invetr ac non inverter ac se km amp lete h kya ?
Sir compressor nahin chalega to rela welpe change karna paraga
Sir clamp metre se communication predical check Karke dikhaiye Hitachi me
किसी भी इनवर्टर एसी का कनेक्शन करने का वीडियो बनाएं
Refrigerant Name
Standing Pressure
R-22
150-155 psi
60-70 psi
R-410a
225-230 psi
120-130 psi
R-134a
85-95 psi
12-15 psi
R-600a
40-50 psi
Below 0-1 psi
R-32
240-245 psi
110-115 psi
R-290
125-130 psi
R-407c
R-404a
R-417
65-70 psi
180-185 psi
75-80 psi
80-90 psi
180-185 psi
140 psi
Suction Pressure
65 psi
Discharge Pressure
Boiling Temp
250-300 psi
-40.8 C
450-500 psi
-51.4 C
-26.2 C
-11.7 C
-52.0 C
275-300 psi
-42.1 C
275-300 psi
-45.0 C
-46.2 C
261 psi
Sir R410 ki jagah R32 Dal sakte hain
Yah chij kuchh compresser per likha hua hota hai
Kya yah baat Sahi hai ya galat
Please Reply
Nahi dal sakte hain
Oil change karke Dal sakte hain
Sar bahut acche se samjhate Hain isliye cal main a raha hun aapke pass aapka number chalu rakhna band mat Karna sar jab main call Karen to receive karna jarur sar Nahin to ham bhatkate rahenge vahi
Ji han
Jaha rasta samajh nahi ayega wAha se call kar lijiye
@@kareemtechnicalmind8172sir number nhi chal rahe
Thanks so much sir 😊
Good afternoon Sr playlists me washing machine, RO, gijar ka bhi cors dal dijia please
Ok
Sir namskar sir 1swal hai ager ham r32gas a c main Charing gej k hisab se kar te hai jese r32 ka back 115.120 rehta hai to wehat k hisab se gas kam dalti hai ager wehat k hisab se gas dalte hai 800gr900gr jo outdoor par di hoti hai to back presar jyada ho jata hai 145.150 k pas chla jata hai
Hello sir R32. Ya R410 ka running pressure 60 ya standing pressure 60 hai to gas charge kar sakte hai ya nahi sir
Sir inverter AC not working me kya kya chek kare is ka video banaye sir jaldi
Sir ji inverter ac 1.5 tan ka hai to uska ampers 7-11 agar lee raha hai to uska gas ok hai. Agar 7 ampers se kam lee raha hai to uska gas kam hai agar 11 ampers se jada lee raha hai to uska condensed chok hai apne students ko achhe se bataiye guru ji. Aap se hath jod 🙏🙏🙏 ke binti hai
Sir super
Sound issue, Mouthpiece nat a good quality, maybe mic to far from speaking area etc .😎
Sir g Non inveter Ac men b esi trah full lequed Gass charging kreyn geyn kia? R410a
Yes
@@kareemtechnicalmind8172 thank you so much sir
❤❤❤❤ I'love you 💗💗💗 good man ❤❤❤
Sar aap kon se state me sikhate ho
Up se
Sir Ji aapka Kolkata me koi technician hai? Mera ek dual inverter AC cooling bahut kam kar raha hai r32 gas wala. Please help
Sir standing pressure main nahin dalna hota hey aap standing pressure main kaise dalte hain
Good
Very nice
Hii taknicon bahi
Good job
Sir good evening
Aur jo hum log ac me Gas charge karte hai wo kaun si gas Hoti hai
410a ki charging line 3/8 ki nahi hoti hai 5/16 ki hogi hai aap ak baar dhayan dijiye
Right
👍👍👍👌👌👌👍👌
Thank you sir
1.5 ka ac ampers 6 aur 7 leta hai bhai
1:27 lloyad inverter AC main value 6.8a hain isme multimeter se kitne value tak gas fill kare
कोई भी फ्रिऑन गॅस पृथ्वीके ओझोन लेअरको हानिकारक होता है । ओझोन लेयर के कमी के कारण सुरजसे आनेवाली किरणोसे स्किन कॅन्सर होता है । और पृथ्वीका तापमान बढता है ।
Thanku sir
Sir ji compressor kaa rpm kis sensor se control hota hai
Nice sir❤
Inverter model me out door unit me expensan vale ka kya kam hota hai btaiye
Sir ac me gas charg kar ke
lock karna parta hy
Sir
Compressor change and flashing indoor out door
Sir aap ka institute kaha pe hai
Mujhe bhi aana hai
V.nice information
Ac ka kam shikhanai ka kiya na charge dhaina hoga
7355543798
Helo
Sir urban clap me humlog ko ye btaya hai ki amp5.75 se 9 amp me fluctuate hona chaiye agar gas puri hai to but gas charging ke baad sirf aapka4 amp aaya Kyu?
Jaroori nahi hai ki amp kam jada ho
@@kareemtechnicalmind8172
Mera matlab 5.75 se 9amp ke bech me kuch bhi ho jaise 6, 6.25, 6.65, 7, ya 8 kuch bhi
🙏🙏🙏🙏
Sir gass ka paressar pura hai lekin ampiyar nahi aaya to kya paroblam hai
Agar ac cool kar rahi hai to Kuchh problem nahi
सर मुझको भी सीखना है ac का काम
कितने का कोर्स है
13500
R 32 top-up kar sakte he ya nhi
Kar sakte hain
Mineral oil bad kansa gas...dalna bola...samaj nehi Aya..jarur batae ji...
R22
Thanks Ashu bhai
Aap ye class kahan chalate hain. Kisi ko sikhna ho to kaise sampark kare?
7355543798
7355543798
panorama inverter ac me p6 error aa rha hai kya ho skta
Sir aap kaha pe rahte hai mujhe bhi aana hai
Up azamgarh me
Sir pahle wiltej chek krne h
Sir ager standing pressure Bata Raha h aur back pressure 0 Bata Raha h Kya problem h
Half choke ki problem hogi
Kya cheez chok h
Choke bro
Sir ham tho 410 ki jagah 32 daal dete hai or 32 ki jagah 410
Sir ac me df show kr rh h q
R 32 gas charge kr sakte hain bhai R 410 me vacyum krne ke baad me kiyoki compressor pr mantion hota charge
Kha mansion hota he Bhai
Nahi
Nahi
Hlo sir ek baat puchni thi haier invater ac ke bare mai@@kareemtechnicalmind8172
Are Sar Mujhe Galiyan dene per majbur mat karo aap ne 2:33 is ka Aage ka video cut Kar Diya pahle Sawal to clear karna tha key compressor ko kaise check Karenge Jaane Do main jawab de deta hun clamp metre se check Karenge compressor chalu hai ya band
Right 😊
Sir aapka office kahan
Sir ji maine 2 ton ke ac me r32 gas charge kiya hai discharge line thnda ho rha hai magar suction line funda nahi ho raha
Gas running pressure 130 pis dikha rha hai
Our me seam 2 ac charge kiya hai 2 no milakr 1300 grm gas lagi hai to kya problem hua hoga pls bataye
Gas bada kar 150 psi pe kariye sahi jo jayega
☺️
R32 or 410 ka oil same hota h
Sir aapka Institute kahan pe hai
Up azamgarh me
🎉🎉🎉🎉
Sir muje bhi course karna hai plz reply kar dejeye sir
Aa sakte hain
7355543798
R410a hai guru ji 150psi nahi 130psi gas ka keval hons chahiye
Sir aap kha se ho
Up azamgarh se
Sr abhi bhi aapki system sahi se vacuum nhi huwa
Or 2 bat khas kr k inverter a.c gas charge jitna ho utana durse krana chahi ye
Sir agar vakum karne par -30 par aa Jaye to 100% likhege nhi hai
Agar likehse rhega to -30 pe nhi aayega
Aisa nahi hai
Kabhi kabha bahut miner leakage bhi hote hain
❤
आपका इंस्टीट्यूट कहा pe hai
Up azamgarh me
Sir coching apka kaha hai
Up azamgarh me
Watch
Sir ji aap ke students keval sticker dekh kar hi gas dange jaha sticker nahi rahega vaha chod ke bhag jayenge log. Standing pressure check kar ke nahi dal payenge log 😂😂😂😂
Sar Koi discount Nahin chal raha hai abhi kya😂
Pls
Bhai 5.16 Ka hota hai 3.8 ka nahin hota hai