Nice Explanation. The advantage from the PMG is that the control power to the AVR is kept near constant, allowing the AVR to quickly recover the voltage of the AC generator back to its nominal preset value. The AVR reacts quicker reducing the transient voltage dip associated with applying load to the alternator. The PMG system also provides the advantage that no residual magnetism is required in order to start the excitation process at start up, whereas for Shunt or Auxiliary wound machines, if the residual magnetism is lost, the generator voltage will fail to build up.
Sir exiting rewinding 4set ka 1 phase hay out 6phas delay hain 6 led bauer out 6 led Anderson hain star main 3 led Hong ya 6 led please during send kar dain
Without AVR generator start kr k jo voltage atay he wo residual voltage hota he jo residual magnetism ki waja se hota he. Iski range 3 volt se 60 , 70 volt tak hosakti he
@@Hemantkumar-yd7xf Alternator ko start kr ke check krte hen agar voltage arhay hen to residual magnetism he agar voltage nhi arhay to residual magnetism loss hogya
Nice Explanation.
The advantage from the PMG is that the control power to the AVR is kept near constant, allowing the AVR to quickly recover the voltage of the AC generator back to its nominal preset value. The AVR reacts quicker reducing the transient voltage dip associated with applying load to the alternator.
The PMG system also provides the advantage that no residual magnetism is required in order to start the excitation process at start up, whereas for Shunt or Auxiliary wound machines, if the residual magnetism is lost, the generator voltage will fail to build up.
Too good..Your classes help me a lot..keep it up..From India.
Very nice explain and Very informative videos keep it up.
Thank you
Simply and briefly defined.
Best teacher🌹...masha allah
jai shree raam❤ nice video sir
Your method soo good thanx bhai
Great bhai your way of teaching
Very nice! Very well explained! Thank you very much!
Very good explanation...
You are best teacher sir #god blesss you
Great work sir
God bless u🌹
NICE EXPLAIN SIR.
Nice sir you are genius
Sir, please tell me protection relays of generator
Dear Asad I am working on project on solar thermal for ORC Turbine coupling with PMA generator is PMA is better for this low pressure 4 bar Turbine
Sir your lecture is very useful, an informative,thanks jazakAllah,sir please explain harmonic,
thanks
Sir 4set kay 6 phase dalyhove hain 6Leeds ko 12 divod min lay hain
ashad bhai 200 kw ka genretor h excitor 100 volt deraha h usme kya problam ho sakti h????
Sir as main 3phase hai main jo foto send my hai 6phas hain as ka daygram dain please
Sir pilot exciter ki teeno wire ki resistance same hogi aapas me ya alag aayegi
Almost same
Nice Sir
Asad bhai engine CCP reasons and effects py agr koi video ha to link share kr den
Nice
Well explained.
Exuitar quael taayar tar ka gaj
Great 👌
Sir exiting rewinding 4set ka 1 phase hay out 6phas delay hain 6 led bauer out 6 led Anderson hain star main 3 led Hong ya 6 led please during send kar dain
Please check email.
Sir
Residual megnetism ko check kaise krte hai
Without AVR generator start kr k jo voltage atay he wo residual voltage hota he jo residual magnetism ki waja se hota he. Iski range 3 volt se 60 , 70 volt tak hosakti he
@@AsadElectrical sir alternator me residual megnetism kaise check krte hai
@@Hemantkumar-yd7xf Alternator ko start kr ke check krte hen agar voltage arhay hen to residual magnetism he agar voltage nhi arhay to residual magnetism loss hogya
Sir Caterpillar c18 635kva exiting rutor 12 divod kay connection kasy hot hain please betana rewinding connection kasy karna
CAT Model C18 or 3412 ?
Sir Caterpillar c18 hay sona watsapps no diana min foto send karta hoin
00971501216068 mirza mukhtar
@@mirzamukhtar1741 please send to asad89electrical@gmail.com
Ok sir Subaru main send karonga
10 KVA ka genrator hain , Usme kabhi voltage aata hain to kabhi voltage aata nahi please reply.
AVR connection check krain
Sir 1100 kw generator
3512 engine.
per self excitation hota hy ya PMG excitation
PMG
Sir you are great. I have learned lot of information of your this Chanel which I could not get last 10 years in field operation
یہ بات ہمارے لئے باعث فخر ہے کہ حضور آپ ہر فالورز کو جواب ضرور دیتے ہیں
Sir kindle AVR main pmg k wire point ko bhe highlight kar daty.
PMG ke wire numbers 11, 12, 13 hotay hen.Har AVR me different terminal number hotay hen. Model ke hisab se dekhna parta he
Sir pls explain why pmg frequency is higher
ok i will explain soon
Sir pls explain dead machine protection of generator and pmg higher frequency high why
Sir ap ko exterior rewind beja hay gmail min
Dear brother now 50kw or any of kw
Generator man stetar and man rutar magnets sistem and FUNCSHION bathan
Are you from Pakistan
Asad Kya hal ha
Apna number sand kro dear
Asslamualaikum kaise ho asad bhai mera sawal hai 1 phase kam ata hai kya ho sakta hai
W,salam. Voltage low atay hen ya phase missing he ?
1 phase km ata hai
Apka question clear nhi hora.
Okay
Sir foto send ky hain ap kay gmail main please check Kareny betana
Thank you sir,
Sir please , ek video 11 kv output wale Stamford alternator me isolation transformer ki working ki bhi bnaye aap.
Thank you sir
Ok, i will try. Thanks
Sir.aap.ka.ph.no.kaia.hai
Islamolicam.bhai.aap.ka.ph.no.kaia hai.satater.k.bary baat krni hai