Programming Altivar ATV312 for Local Speed and 2 Wire Start Stop Control | Schneider VFD

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 ธ.ค. 2015
  • Are you looking to configure the ATV312 for local speed control and 2-wire start/stop operation? Join us in this informative tutorial as we walk you through the step-by-step procedure for setting up the Altivar 312 drive to enable local HMI dial speed control and seamless 2-wire start/stop control via dry contacts.
    ➡️Whether you're an IT support professional, a variable speed drive enthusiast, or simply interested in Schneider Electric products, this video is your comprehensive guide to ATV312 programming and parameter settings. Don't miss out on optimizing your VFD motor control with Schneider Electric's Altivar 312!
    🔔 Timestamps:
    0:01 Configuring ATV312 for Local Speed and 2 Wire Start Stop Control
    0:05 Overview
    0:15 How to put the drive into local control
    0:40 How to change your run command to come from the terminals
    1:13 How to make sure access level is high enough
    2:34 How to put the drive back into running mode using your dial as a speed reference
    🔗 Learn More: www.schneider-electric.us/en/...
    🔗 Watch more Altivar 312 Tutorials: • Programming Altivar AT...
    🔗 Watch more Altivar How-to videos: • Altivar 320 Drive Conf...
    🔗 Download the mySchneider App: www.se.com/us/en/work/support...
    ---------------------------------------------------------------------------------------------------------------------------------------------------------
    🎯 DISCOVER JOB OPPORTUNITIES
    ---------------------------------------------------------------------------------------------------------------------------------------------------------
    ➡️ Job Opportunities: spr.ly/SE-Careers
    ---------------------------------------------------------------------------------------------------------------------------------------------------------
    👋 GET TO KNOW US BETTER
    ---------------------------------------------------------------------------------------------------------------------------------------------------------
    ➡️ Global Website: spr.ly/SchneiderElectric
    ➡️ Discover our Services: spr.ly/SE-Services
    ➡️ Visit our Blog: spr.ly/SE-Blog
    ➡️ Click here to subscribe to Schneider Electric: / schneiderelectric
    ---------------------------------------------------------------------------------------------------------------------------------------------------------
    ⚡ GET IN TOUCH VIA SOCIAL MEDIA
    ---------------------------------------------------------------------------------------------------------------------------------------------------------
    ➡️ LinkedIn: / schneider-electric
    ➡️ Facebook: / schneiderelectric
    ➡️ Twitter: https: / schneiderelec
    ➡️ Instagram: / schneiderelectric
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 40

  • @timramich
    @timramich 8 ปีที่แล้ว +4

    Thank you for this video. These drives have a very confusing menu structure. Most of the functionality in these things I don't even use. I've been tearing my hair out at work trying to get this to work, as described in this video. Re. another video, you mention changing running modes alters some settings, so no wonder why I messed up a drive that was already working... Videos like this are very helpful in understanding the book. Now that I've watched this, I go back and read the menu settings in the book, and I just want to plant my face in my hands, as I feel so stupid that I didn't get it from reading it...

  • @ruipaulofsantos
    @ruipaulofsantos 7 ปีที่แล้ว

    Thank you, you saved my day!!!!

  • @aadedeelectric
    @aadedeelectric 2 ปีที่แล้ว

    thank you for sharing this video..good job

  • @drVukelja
    @drVukelja 7 ปีที่แล้ว

    Thanks man!!!

  • @zairykucai3000
    @zairykucai3000 5 ปีที่แล้ว

    U saved my life today.. This inverter really really hard to use.. The programming structure really really really hard to understand..

  • @baskarchandrakasan995
    @baskarchandrakasan995 ปีที่แล้ว

    Very nice teaching sir 👍

  • @anwerknittingtechnology.
    @anwerknittingtechnology. 7 ปีที่แล้ว

    thanks

  • @nayantha88
    @nayantha88 3 ปีที่แล้ว

    Hi,
    Once we done this do we need to change rEF parameter to AIUI for the jog enabling? or will it automatically set?

  • @tomasdeleonhernandez432
    @tomasdeleonhernandez432 7 ปีที่แล้ว

    Great

  • @joeski541
    @joeski541 5 ปีที่แล้ว +2

    Did you just connect the 24v, li1 and li2 + the powersupply for this?

  • @rishinishad48
    @rishinishad48 6 ปีที่แล้ว

    i want ur help...how to connect digital speed meter to avt312 drive? and any parameter setting to digital speed meter....plzhelp me

  • @habiblaghrib9942
    @habiblaghrib9942 7 ปีที่แล้ว

    je voudrai savoir en detail la connection du bornier electronique d un variateur movitrac(x10)

  • @madiespoir4218
    @madiespoir4218 8 ปีที่แล้ว

    my ATV312 doesn't show rdy in first time i press and i hold the mode key and after rEF displays help me thank you.

  • @yusranakbar
    @yusranakbar 4 ปีที่แล้ว

    Problems in inverter keypad atv12h075m2 not functioning and out cff code.What should i do?

  • @semenovalexn
    @semenovalexn 4 ปีที่แล้ว

    Altivar 312 не запускает двигатель с редуктором при 5 Гц,а уже при 6,5 запуск двигателя есть.0,75 altivar ,а двигатель 0,55 вт(с редуктором,подключения треугольник) какие параметры надо изменить,чтоб работал при 4-5 Гц.Спасибо

  • @MukeshSharma-oh1eq
    @MukeshSharma-oh1eq 3 ปีที่แล้ว

    Please Sir solution for OPF1 foalt Atv12hu15m2 vfd

  • @BeardyMagicGuy
    @BeardyMagicGuy 5 ปีที่แล้ว

    Hi, thanks for the video, I have gone through all of these commands but still when I run the speed is locked in at 15 and cannot be altered by the dial... is there a limit that’s in place that I can turn off? Please advise

  • @MukeshSharma-oh1eq
    @MukeshSharma-oh1eq 3 ปีที่แล้ว

    Opf1 foalt solution please sir Atv12hu15m2

  • @velmuruganrajesh8240
    @velmuruganrajesh8240 4 ปีที่แล้ว

    How to activate relay function. How to use 0 frequency use normally No 0.1Hz Normally Nc How to activate. Pls send program settings.

  • @chanduyadav4171
    @chanduyadav4171 7 ปีที่แล้ว

    I dont understand for vfd controll by remote mode
    plz tell me about this from starting

    • @TheJohnClay
      @TheJohnClay 7 ปีที่แล้ว +1

      Remote mode means the speed (frequency or motor speed in Hertz) and command (start and stop control) come from a source outside of the drive (such as a computer or building control center). Local mode means the speed and command are performed using the buttons on the drive itself. These controls can be separate so the command to start can be done locally using the buttons on the drive and the speed can come from a computer (or vice versa).

  • @user-pu7vm4me1i
    @user-pu7vm4me1i 16 วันที่ผ่านมา

    Как настроить реверс

  • @yrwinnberroa6498
    @yrwinnberroa6498 2 หลายเดือนก่อน

    hello i have a problem with my VFD is showing Over speed i using in Hydraulic pump do you know What parameter can I change to avoid that issue. is ATV630C16n4

    • @schneiderelectric
      @schneiderelectric  2 หลายเดือนก่อน

      Thank you for your message. We house most of our documentation in a virtual database here: www.se.com/ww/en/download/. If this does not address your concerns, please reach out to a technical support person in your location.www.se.com/ww/en/work/support/country-selector/contact-us.jsp

  • @rajamazher554433
    @rajamazher554433 2 ปีที่แล้ว

    only fowerd run motor no rerwes run motor drive contection p24 F Forwed R rewes but no reweses motor run plz help me

  • @rudyescala9746
    @rudyescala9746 6 ปีที่แล้ว

    All can u help me how to set parameter setting two units of inverter control in one volume

    • @rudyescala9746
      @rudyescala9746 6 ปีที่แล้ว

      I have problem we have a machine
      Use two inverter and controled in one volume .. when it damage i change the other one but when i start up the two inverter is more than 10hz defference i need only 2 hz defferent each other
      ...and now how to set this parameter

    • @rudyescala9746
      @rudyescala9746 6 ปีที่แล้ว

      Please help me

    • @schneiderelectric
      @schneiderelectric  6 ปีที่แล้ว

      Hi Rudy,
      Thanks for reaching out. Please contact our support team directly for further assistance.
      Phone: 800-468-5342 option 1 (Internally dial 25777)
      Hours of operation: 8am-8pm ET, Mon-Fri excluding holidays
      e-mail: customer.services@us.schneider-electric.com

  • @velmuruganrajesh8240
    @velmuruganrajesh8240 4 ปีที่แล้ว

    How to use DC break Schneider altiva312 ac drive
    Input voltage 230volt
    Out put voltage 220 3phase
    Motor kW 0.75kw

  • @dmitryradchenko7458
    @dmitryradchenko7458 6 ปีที่แล้ว

    Schneider Electric Altivar -Трехпроводное управление Three-wire control-button th-cam.com/video/D8ZfJ-XtkHU/w-d-xo.html

  • @bhoopendrabhardwaj4079
    @bhoopendrabhardwaj4079 5 ปีที่แล้ว

    Sir my v fd derrik not work in load

  • @kathiravan1013
    @kathiravan1013 5 ปีที่แล้ว

    OSF come, so, that one resetting program tell him

  • @jkj1459
    @jkj1459 6 ปีที่แล้ว +3

    why keep changing ,procedures .in Schneider products , please keep it uniform and make it user friendly .

    • @zxhoon
      @zxhoon 6 ปีที่แล้ว

      ^^This - I wrongly assumed that I could configure the same way as an ATV61/71, by simply going to CTL, access level to 3 (from reading the 312 manual), I/O mode to separate and then ref to the jog wheel with command on the terminal. It didn't work, found this video which helped, but why does the VSD need to be put into local mode in the first place? If you configure the separate I/O mode, command on terminal speed ref on jog wheel, why doesn't it run? Stupid

    • @schneiderelectric
      @schneiderelectric  6 ปีที่แล้ว

      Thanks for reaching out. The ATV312 is much different than the 61 or 71 as it relates to HMI control. The ATV312 knobs primary function in menu navigation. Speed reference is secondary. The knob can be used as speed control by setting FR1 to AIV1, but to use the knob you must navigate to LFR parameter first (easily done by pressing knob 3 times) The display is shown as 0-100% only, not in Hz this way. In local mode, the knob is primarily speed control, and secondary menu navigation. The way the 312 was engineered, to use the knob for speed control without going to the LFR parameter, we have to put the drive into local mode (knob now works without going to LFR) and set the profile to separate and command via terminals. Hope this helps.

  • @pawanshrivastav68
    @pawanshrivastav68 6 ปีที่แล้ว

    Plz Hindi vedio language to knowledge

  • @dmitryradchenko7458
    @dmitryradchenko7458 6 ปีที่แล้ว

    Schneider Electric Altivar -Трехпроводное управление Three-wire control-button th-cam.com/video/D8ZfJ-XtkHU/w-d-xo.html

    • @dadabobade3026
      @dadabobade3026 6 ปีที่แล้ว

      Dmltry Radchenko atv320d15n4bkw20hp380to500vlt