1)4 Pole isolator--> 3 phase rotary switch selector-->4 pole MCB--> 4 pole RCCB 2)4 pole isolator-->4pole MCB -->4pole RCCB-->3 phase rotary selector bro which is good? 1 or 2?
Brother ippo antha veettoda total amps evvolo nu approximate ah calculate panni அதை 2 ஆள multiple panni main mcb use pannalam min 5kw na 16 amps எடுக்கும்
Bro single phase Ku eppaum 0.6 dhan power factor varuma aprom 3 phase Ku eppaum 0.8 dhan power factor varuma most a indha rendu value dhan power factor varuma bro
@@ELECTRICALTECHWIZARD bro neenga epdi power factor value 0.6 nu pottinga adhuve ipo 3 phase na 0.8 podanuma illa single phase Ku power factor value evlo podalam 3 phase Ku evlo value pottu MCB calculate panlam adha mattum sollunga bro
@@ELECTRICALTECHWIZARD single phase Ku 0.6 values pottu calculate panlama aprom 3 phase Ku 0.8 blade podalama adha adha mattum sollunga bro illa single phase & 3 phase Ku evlo value podalam adha sollunga
இப்போ fan normal ah 1 amps எடுக்கும் அது bearing போய் இருந்த கொஞ்சம் load kuda எடுக்கலாம் அது மாதிரி continue vaa load எடுத்தா fan coil சீக்கிரம் போகும் அது மாதிரி தான் ஒவ்வொரு load um ennaku தெரிஞ்சது brother 🙏
முதலில் மின் இணைப்பு வேலைகளை செய்பவர்கள் தமிழ்நாடு மின் உரிமம் வழங்கும் வாரியத்தில் உரிமம் பெற்றவராக இருக்கவேண்டும் அனைவரும் எலெக்ட்ரிஸியான் ஆகமுடியாது
பொதுவா C16 Single pole MCB USE பண்ணுங்க,நீங்க பயன்படுத்துற MCB 50% output குடுத்த MCB LIFE நல்லாயிருக்கும். எடுத்துக்காட்டு : 8 amps use பண்றீங்க என்றால் 16 amps mcb போட்ட நல்லது.
contact number TH-cam la send panna miss use akirum brother so please any doubt comment pannunga udanae reply pantren mostly c type mcb thaan use pannuvom brother
@@ELECTRICALTECHWIZARD super bro . Adhan practical aahve evlo therinji vachirukinga . Naa deee apram Be eee bro and additional rivit mep but unga knowledge la paathikooda illa . Diploma really better than be bro , coz be la edhuvume practical aah Panna mudiyadhu
4 amps load ku 10 amps mcb பயன்படுத்தும் போது load 4 amps பதிலாக 6 or 8 amps load continues எடுக்கும் போது 10 amps mcb trib ஆகாது so load failure aaga வாய்ப்பு உண்டு 6 amps mcb use pannalam bro
One of the best videos about mcb on TH-cam. Super
Thanks brother 🙏
சகோ ரொம்ப தெளிவான விளக்கம் எனக்கு ரொம்ப பிடித்திருந்தது நன்றி சகோ வாழ்த்துகள்...
Thanks Nanba 😍😎😍
I like it very good explanation
Thanks Brother ❣️
Neenga explain pann intha video la -DB Box la ennanna mcb use paningaka...and ELCB.... sollunga na... and thanks for the mcb information...
6 amps,10 amps,20 amps mcb 25 amps rccb use pannen brother
Bro veetla 3 phase ku 3 fuse carrier main board la iruku. Ipo 4 pole MCB install panna fuse carrier ah remove panidalama?
Awesome explanation
Thanks 😊
1)4 Pole isolator--> 3 phase rotary switch selector-->4 pole MCB--> 4 pole RCCB
2)4 pole isolator-->4pole MCB -->4pole RCCB-->3 phase rotary selector
bro which is good? 1 or 2?
clear explanation super bro
Thanks Brother ❣️
Very nice explain. Supper bro. Industrial user MCB how to select
This is very useful. Are AFCI/GFCI/Combination used in our houses ? Do ACs require a separate HACR or regular MCB is enough ?
House ku normal MCB, rccb போதும் தலைவா mcb range விட அதிகம் load use panna MCCB use pannalaam ❣️
Which brand is best for MCB bro??
Clear explanation
Thanks Brother ❣️
Bro basically howmany HP for main mcb for house... Per each room... Nice explained
Thanks Brother ❣️
Good explanation
Thanks Brother ❣️
Diagram xplain vara level professor
professor ah நானு....🙏
S sir.Neeinga xplain pantra level uneducated people ku understand akum sir
Sir in my area have 40ma RCBO than iruku .single phase supply ku use pannalama? May Iknow difference between 32ma and 40ma .
Milli amps decrease ஆக ஆக fault சமயத்தில ரொம்ப நம்மல safety பண்ணும் avvalavu தான்...
Super sir
Superb bro
Wire size sollunga bro
how to choose proper wire size for house wiring video already pottu iruken Nanba check panni பாருங்க
Super anna
Thanks Thambi ❣️
Thala semma super
Thanks Thala
Super bro thank you
Thanks brother 🙏❣️
How to select MCB for 3 phase motor plz explain
Bro switches and wires for home entha brand use panlam
finolex kundan cab wire use pannalam and switch lisha GM use pannalam brother 🙏 but switch rate konjam athigam வரும்
@@ELECTRICALTECHWIZARD tq bro.switch-havells,wiring-finolex panalamaahh??
A/C Ku mattum separate MCB vaikkanuma? Bro
separate ah use panna நல்லது
Hi brother,,,6AMPs extension wire box sa 10MCB la load kudutha trip aguma Annan
6 amps wire box minimum 8 amps load தாங்கும் and load 10 amps mela pona mcb trip aagum brother
Hi bro, enga veetu halla fridge, a/c use pannaporom so Ethan's amps MCB use pannanum
16 amps mcb podalam Brother ❣️
Bro, Why you can use demand factor in this calculation, Can you plz explain?
Demand factor na ella electrical equipment orai time run akathu
Power factor bro.... Current calculation 1phase I=P/V*P.F
Idha tha soldrapla
1.5 hp submersible motor க்கு எத்தனை Ams போட வேண்டும்? MCB லலிருந்து மோட்டாருக்கு எந்த Sq. Wire போட வேண்டும ்( 4 Sq or 2.5 sq)
4 sq mm or 6 sq mm wire podunga motor depth athigamaga iruntha amps athigam எடுக்கும்
நன்றி ஐயா
420 அடி
எனக்கு அவ்வளவு வயசு aagala brother 🙏😍🙏
Ok bro
நண்பா, 4 pole MCB -> 4 pole RCCB -> SP MCB வைக்கலாமா இல்லை 4 pole RCCB -> SP MCB வைத்தால் மட்டும் போதுமா? இதை நான் கேட்டது 3 phase மீட்டருக்கு?
first method use pannalaam Nanba ❣️
@@ELECTRICALTECHWIZARD நன்றி நண்பா
Welcome நண்பா
In Kitchen we are using grinder and mixi, Inga entha MCB use pannanum
kitchen la min 16 to 25 amps mcb podalam Brother ❣️
Bro 1ton ac, dc board la evlo amp mcb podamun and ac power. Box la evlo amp mcb use pannanum pls reply me Bro
10 to 16 amps podalam Brother
Bro both side are 10to16 ha bro
ஆமா Brother
Bro 6 to 10ams na which tybe bro mcb c ah
light load ku b type induction load ku c type mcb brother
மெயின் சுவிட்ச்கு mcb 2 pole 64 ஐ பயன்படுத்தலாமா
Load அதிகமாகஇருந்தால் use பண்ணலாம் brother
@@ELECTRICALTECHWIZARD 5 சீலிங் பேன்,1பிரிஜ்,1, வாசிங் பிசின்,13 led டியூப்லை,32, இஞ் led tv, 2,w நைட்லாம்ப், 1 எலக்ட்ரிக் கேட்டல் 1800w,
1, சுடுதண்ணீர் சவர்,
Apdiyae industrial kum evlo load kodukanum
Anna 3 pass DP ku ELCB Bestta RCCB Bestta Ethu potalam
elcb odaa advance thaan rccb so rccb podalaam
2 pole mcb 1 --1 pole mcb 5 box size sollunga bro
8 way mcb db இருக்கு Brother ❣️
Bro ipo ORU veetla 20 amphs mxz size iruku ipo idha 2 aala multiple Panna 40 varudhu apo idhuku 40 amphs main MCB use panlama aprom 25 amphs vandha adhuku 50 amphs main MCB use pannanuma apdidhana kinjam detail a sollunga bro
Brother ippo antha veettoda total amps evvolo nu approximate ah calculate panni அதை 2 ஆள multiple panni main mcb use pannalam min 5kw na 16 amps எடுக்கும்
@@ELECTRICALTECHWIZARD bro ipo 5 room irukuna adhoda total load calculate panni podanuma
ஆமா ப்ரோ
@@ELECTRICALTECHWIZARD bro neenga indha video la 5 room Ku calculate pottu MCB select panninga idhula ORU ORU roomku iruka amphs calculate pannanuma neenga 0.5,1.9,8.1,4.5,0.4 idhu calculate panni idhuKu Vara total amphs Ku rendala perukanuma adha base panni MCB select pannanuna ungaluku 15.4 varudhu 16 amphs a eduthukittinga idha rendala perukuna 32 varum ipdidhan MCB select pannanuna adhe 5 room Ku total load amphs 18 varudhu so adhuku 36 amphs varum idhuku 40 amphs choose pannanuma apdidhana idhuku mattum reply pannunga bro doubt fulla clear bro
Bro Mela kettadhuku mattum reply pannunga bro
Bro AC ku. Ethana amp MCB kudugalam
Reply please
1ton 16amps
1.5ton 25 amps mcb use pannalaam Brother
tq bro
Welcome bro
Bro single phase Ku eppaum 0.6 dhan power factor varuma aprom 3 phase Ku eppaum 0.8 dhan power factor varuma most a indha rendu value dhan power factor varuma bro
அது power factor maintain panratha பொறுத்து bro 0.8 to 0.9 and 1 power factor வந்தா good condition
@@ELECTRICALTECHWIZARD bro neenga epdi power factor value 0.6 nu pottinga adhuve ipo 3 phase na 0.8 podanuma illa single phase Ku power factor value evlo podalam 3 phase Ku evlo value pottu MCB calculate panlam adha mattum sollunga bro
அது demand factor value 0.6 single and 3 phase value same thaan
@@ELECTRICALTECHWIZARD single phase Ku 0.6 values pottu calculate panlama aprom 3 phase Ku 0.8 blade podalama adha adha mattum sollunga bro illa single phase & 3 phase Ku evlo value podalam adha sollunga
brother 1 phase and 3 phase ரெண்டுக்குமே 0.6 pottu calculate pannunga illa total Watts/voltage pottu calculate pannunga brother
Kundan fybros brand?
Bro load convert the formula 0.6 ila 0.8 ah
0.6 demand factor brother normal formula use pannalaam I = P/V
லைனில் எவ்வளவு கரண்ட் வந்தால் mcb tripஆகும். அதன் மேல் குறித்த அளவா 6,10 amps or times fload current.
mcb rating பொறுத்து trip ஆகும் 6a mcb continues 9a எடுத்தா trip ஆகும்
@@ELECTRICALTECHWIZARD means if it takes 1.5 times the rating marked on mcb.continuous என்றால் எவ்வளவு நேரம்.
உள்ள இருக்க bimatalic strip heat ana உடனே trip ஆகும் ex 30 sec athu mcb characteristics பொறுத்தது
@@ELECTRICALTECHWIZARD what about magnetic
40A MCB select panna ..enna agum ? For 4 A load
4 amps load ku 40 amps mcb use panna eppadi problem naa trip ஆகும்
@@ELECTRICALTECHWIZARD enna problem varum bro? Short circuit na current romba heavy ah irukum.. like 10kA
இப்போ fan normal ah 1 amps எடுக்கும் அது bearing போய் இருந்த கொஞ்சம் load kuda எடுக்கலாம் அது மாதிரி continue vaa load எடுத்தா fan coil சீக்கிரம் போகும் அது மாதிரி தான் ஒவ்வொரு load um ennaku தெரிஞ்சது brother 🙏
@@ELECTRICALTECHWIZARD thanks bro
Very useful video ji
Thanks Nanba 🙏😍
முதலில் மின் இணைப்பு வேலைகளை செய்பவர்கள் தமிழ்நாடு மின் உரிமம் வழங்கும் வாரியத்தில் உரிமம் பெற்றவராக இருக்கவேண்டும் அனைவரும் எலெக்ட்ரிஸியான் ஆகமுடியாது
Worth
Thanks Brother ❣️
Bro some mistakes irukku... Lighting load , power load orai mcb la kudukka kudathu
Yes Brother ❣️
@@ELECTRICALTECHWIZARD good... Keep it up...
❣️ Thanks Brother ❣️
Main Dp board la MCB, RCP, isolator, earth connection epdi sir fitting pannuvathu...plz sir explains with you sir ....
Already video pottu iruken Nanba 🙏❣️🙏
Bedroomla A/C and other need lights and fan, Inga evlo amps MCB use pannaum,
light fan load ku 6 amps mcb podalam ac ku 16 amps mcb podalam brother
பொதுவா C16 Single pole MCB USE பண்ணுங்க,நீங்க பயன்படுத்துற MCB 50% output குடுத்த MCB LIFE நல்லாயிருக்கும்.
எடுத்துக்காட்டு : 8 amps use பண்றீங்க என்றால் 16 amps mcb போட்ட நல்லது.
😘✔️
@@ELECTRICALTECHWIZARD 🙏🙏
Shop ku enthamathiri mcb use pannanum?
Lighting b type mcb
induction load ku c type mcb brother 🙏
Thank you. Eb le irunthu elcb fix Panna solrange for meter fixing. What type of elcb?. One shop load is. 970 kw. Another is. 460 kw
என்ன brother சொல்லுறீங்க 960 kw 1285 hp avvalavu load ah use pantringa 460 kw = 615 hp
Elcb la Earth fault current ratio பொறுத்து use pannuvanga 30mA,100mA,300mA
Super da
Thanks da
Gem
🤔🤔🤔
1amps evlo watts edukum bro?
250 watts
@@ELECTRICALTECHWIZARD apdiye 10 hp motor ley delta , connection ,star connection kandupidikurathu epdi bro?
name plate pottu iruppanga இல்ல multimeter la check pannanum brother
எலக்ட்ரிக்கல் படிக்கும் மாணவர்களுக்கு வகுப்பு எடுத்ததுபோல் இருக்கிறது ..... சாமானியர்களுக்கும் புரிவதுபோல் விளக்க முயற்சிக்கலாமே சார் ...
mmm okay brother 🙏❣️🙏 and Thanks for watching this video brother 🙏
Intha Db LA connection epdi sir kodupathu.....
distribution board wiring connection already pottu iruken பாருங்க நண்பா
Bro appadiyea wire selection num sollunga
Video already pottu iruken பாருங்க brother 🙏
Bro demand factor epadi 0.6 soldrenga
Bro antha paper ah PDF format la upload pannunga... Illati personal ah anupunga bro.
எப்படி brother
@@ELECTRICALTECHWIZARD 9003886762 this is my WhatsApp. Kindly send bro
Photo eduthu pottalum ok
brother antha work sheet இப்போ இல்ல so நீங்க வீடியோ வா screen shot எடுத்துக்கோங்க please
தெளிவான விளக்கம்
Thanks Brother ❣️
Orbit And Liguard
Super 💌 brother 🙏
Legend
கத்து குட்டி Brother ❣️
Standard mcb
1.1/2 டன் AC க்கு 16 Ams mcp போதுமா
20 amps pothum
Thangs
Please Incoming cable size Meter to MCCB ?for 32 amps load , and earthing cable size ? From switch box to earth pit
7/16 or 7/20 (6 or 4 sq mm) wire phase ku use pannalam and Earth wire also same to use Nanba 😍🙏😍
Deference to b type and c type mcb
b type mcb resistive load ku
c type mcb induction load ku brother 🙏
Indoasian MCB
Super 💌 brother and Thanks for watching this video🙏
அண்ணா அந்த DB Box கலட்டி Connection எப்படி இருக்குதூன்னூ காட்டுக அண்ணா அந்தா Connection எனக்கு தெறியாது please please ppppppp
இதே distribution board wiring video already pottu iruken பாருங்க நண்பா
Legrand MCB jii
❣️
Lisa MCB bro
L&T mcb
Super
Hi bro... I am new electricen bro... Help panunga bro.... Unga contact number aolunga bro..... House wiring ku B or C type ethu use panuvom
contact number TH-cam la send panna miss use akirum brother so please any doubt comment pannunga udanae reply pantren
mostly c type mcb thaan use pannuvom brother
B = Resistive load like heater, incandescent lamps.
C = Inductive load like AC, Pump.
V fred mcb
Havewells breaker better
Okay thanks நண்பா
Fybros MCB
Super 💌 brother
kundan, standard and legrand
Super 💌 brother
Bro neenga Enna padichirikinga
DEEE Brother
@@ELECTRICALTECHWIZARD super bro . Adhan practical aahve evlo therinji vachirukinga . Naa deee apram Be eee bro and additional rivit mep but unga knowledge la paathikooda illa . Diploma really better than be bro , coz be la edhuvume practical aah Panna mudiyadhu
Diploma layuim practical avvalavu இருக்காது brother but இப்போ எனக்கு தெரிந்த தகவல் எல்லாம் working field la kaththukkitathu thaan brother ❣️
பயன்படுத்தூர Load பொருத்து MCB பயன்படுத்தனூம் 04 Amps lightக்கு 10 Amps பயன்படுத்தனா எண்ணாவும் அண்ணா Phone Number please send me
4 amps load ku 10 amps mcb பயன்படுத்தும் போது load 4 amps பதிலாக 6 or 8 amps load continues எடுக்கும் போது 10 amps mcb trib ஆகாது so load failure aaga வாய்ப்பு உண்டு 6 amps mcb use pannalam bro
Sir, I can't understand
லேங்ரேன்ட்
Antha 230 ennathu anna
supply voltage pa
Hmm ok anna
Thanks brother
Single phase voltage 230 kuda divided pannanuma anna
aama thambi watts divided voltage
Kundan r Fybros
🙏
Super anna
Thanks Thambi 🙏❣️🙏
super bro
Thanks Brother ❣️
Super Bro
Thanks brother 💌