UT Weld Slag Inclusion Signal

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 มี.ค. 2020
  • This video demonstrates the Ultrasonic Testing signal when inspecting a weld with slag inclusion. Equipment: Olympus EPOCH 1000i UT tester, 60 degree, 4Mhz, 10mm diameter transducer, 0.625" in thick carbon steel plates with single V 30 degree bevel.
    I work at Central Piedmont Community College in Charlotte, NC. Please visit our website to explore your NDE training needs.
    Central Piedmont Community College NonDestructive Examination Technology Program
    www.cpcc.edu/programs/nondest...
    Central Piedmont Community College NonDestructive Examination Technology Program College Catalog
    catalog.cpcc.edu/programsofstu...

ความคิดเห็น • 8

  • @rodstephens742
    @rodstephens742 4 ปีที่แล้ว +1

    Notice the gain is PRL +12 dB...volumetric reflectors are scattering reflectors and higher gain levels are needed to see them properly. The key shows DAC -5 dB. Contrast this to a SLOF indication in another of John's videos at DAC +13 dB.

  • @antvd888
    @antvd888 ปีที่แล้ว

    Thanks John!

  • @santiagocruz9060
    @santiagocruz9060 2 ปีที่แล้ว

    Hi jhon, very clare the explication

  • @arifbugga7186
    @arifbugga7186 3 ปีที่แล้ว

    thanx sir

  • @bharatsharma5342
    @bharatsharma5342 3 ปีที่แล้ว

    What's dynamic echo pattern in ultrasonic testing? How to do sensitivity settings?

  • @mariusvasilache888
    @mariusvasilache888 ปีที่แล้ว +1

    Your DB reference is extremely high for a IIW SDH....

  • @GaserElwerdany
    @GaserElwerdany 2 หลายเดือนก่อน

    يوجد لدى جهاز كاشف الخلل بالموجات فوق صوتية للبيع ‏‪0:46‬‏

  • @allwinthivan6795
    @allwinthivan6795 ปีที่แล้ว

    Sir, pipe thickness 6.4 mm, dia 4".ut testing half skip catch one defect sir, but defect beam bath full beambath is coming, why is this happening, sir 70 degree probe use sir true angle 69 degree, but defect half skip and depth ok sir but beam bath only high full beam bath coming sir. Why sir. Please tell me sir