UT Lack Of Sidewall Fusion Signal

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 มี.ค. 2020
  • This video demonstrates the Ultrasonic Testing signal when inspecting a weld with lack of sidewall fusion. Equipment: Olympus EPOCH 1000i UT tester, 60 degree, 4Mhz, 10mm diameter transducer, 0.625" in thick carbon steel plates with single V 30 degree bevel.
    I work at Central Piedmont Community College in Charlotte, NC. Please visit our website to explore your NDE training needs.
    Central Piedmont Community College NonDestructive Examination Technology Program
    www.cpcc.edu/programs/nondest...
    Central Piedmont Community College NonDestructive Examination Technology Program College Catalog
    catalog.cpcc.edu/programsofstu...

ความคิดเห็น • 7

  • @RandomStuff-zs6cw
    @RandomStuff-zs6cw 4 วันที่ผ่านมา

    Wonderful Sir 😊

  • @ahmedadil939
    @ahmedadil939 3 ปีที่แล้ว

    thanks so much

  • @dudeabc100
    @dudeabc100 3 ปีที่แล้ว +1

    Hi sir, nice video!
    From the upstream side this Side wall lack of fusion can be seen on the third leg.
    Sometimes based on the LOF geometry or slag inclusion coupled with LOF you could possibly
    see it on the 2nd leg as well from the upsteam side.

  • @abinashsahu6445
    @abinashsahu6445 3 ปีที่แล้ว

    nice sir

  • @oluwabiyi30
    @oluwabiyi30 ปีที่แล้ว

    What was your screen range?

  • @geemarino6066
    @geemarino6066 2 ปีที่แล้ว

    Can you demonstrate to us the high low weld...