Load Chart Problem: Grove TLL Teleboom Gross Load

แชร์
ฝัง

ความคิดเห็น • 38

  • @frozt2762
    @frozt2762 5 ปีที่แล้ว +1

    Just pass my tests man thanks for all your help very helpful 👍

  • @SuperAWOLL
    @SuperAWOLL 5 ปีที่แล้ว

    This video was very helpful, thanks!

  • @zakirkhan-lw3wh
    @zakirkhan-lw3wh 6 ปีที่แล้ว +1

    Thanks so video nice good job

  • @bryanmunoz4867
    @bryanmunoz4867 2 ปีที่แล้ว

    Very helpful

  • @LoadChartLab
    @LoadChartLab  5 ปีที่แล้ว

    Frozt 27, if you are using boom angle to find chart capacity and are given an angle not listed in the chart , look at the capacity for the next highest boom angle and the capacity for next lowest boom angle and use the lower capacity. For example you are trying to find capacity with 100 feet of boom at a 50 degree boom a angle. The chart does not have a capacity for 50 degrees but it does for 48 degrees and 52 degrees. The capacity at 48 is 20,000 lbs., capacity at 52 degrees is 23,000 lbs. Your chart capacity is 20,000 lbs. Compare capacity for higher and lower angles, use lower capacity. Usually the lower angle will have lower capacity. Hope this answers your question. If not let me know.

    • @frozt2762
      @frozt2762 5 ปีที่แล้ว

      Thanks man now I get it if is in between values use the longest.
      I pass the core and the small I have problems with the large load chart

  • @LoadChartLab
    @LoadChartLab  5 ปีที่แล้ว

    Frost 27, the numbers in the example are not actually from the grove chart. I just made them up to illustrate the process when boom angle is not in the chart

    • @mjhhhy5069
      @mjhhhy5069 4 ปีที่แล้ว +1

      leberer1055crean.lodcart

  • @jsantiago1620
    @jsantiago1620 6 ปีที่แล้ว

    Thanks for the help!!! Could you do some videos for a fixed cab

    • @LoadChartLab
      @LoadChartLab  6 ปีที่แล้ว

      Joe. Glad they videos are helping. I may eventually do some fixed cab examples but its really not my area--when my work slows down a little I'll look into it.

  • @mikebremer1537
    @mikebremer1537 5 ปีที่แล้ว

    I have a question about the upper boom point never being a deduction on the manitowoc crane you are using. What model is it and is that specific to it.
    Thanks
    Mike

    • @LoadChartLab
      @LoadChartLab  5 ปีที่แล้ว +1

      Hello Mike. This statement only applies to the Manitowoc lattice boom crawler on the CCO specialty exams. There is no deduction for the upper boom point on the CCO LBC specialty exam. Otherwise it depends on the model of crane and the carrier. It will be different for different cranes, different setup (for example, 4100 does require an upper boom point deduction). When putting together a "real" lift plan always check the load charts, notes and other documentation. Also, if you or anyone else is taking the CCO specialty for lattice boom truck, there is a deduction for the upper boom point. The load charts used for CCO exams do not identify a specific model, but the numbers they give you in the chart for the exam, are pretty much a identical to a Manitowoc 888.

  • @LoadChartLab
    @LoadChartLab  5 ปีที่แล้ว

    Had a question about tip height. 70 foot boom and 30 foot radius equals 70 ft tip height.

    • @LoadChartLab
      @LoadChartLab  5 ปีที่แล้ว

      This is for ghe grove tll

    • @mitchsmithers1760
      @mitchsmithers1760 4 ปีที่แล้ว

      It's actually 80 ft

    • @LoadChartLab
      @LoadChartLab  3 ปีที่แล้ว

      @@mitchsmithers1760 How do you get 80? With 70 feet of boom and 30 foot radius?

  • @A.J.PMotivation
    @A.J.PMotivation 6 ปีที่แล้ว

    I'm retaking in January

  • @frozt2762
    @frozt2762 5 ปีที่แล้ว

    Im having trouble with gross capacity with just a degree angle the fall in between values can you help me

  • @A.J.PMotivation
    @A.J.PMotivation 6 ปีที่แล้ว

    What do I do if they ask for main rope and aux rope

    • @LoadChartLab
      @LoadChartLab  6 ปีที่แล้ว

      Can you give me a little more information? If you could send me the question that would be great.

    • @A.J.PMotivation
      @A.J.PMotivation 6 ปีที่แล้ว

      I took my grove test and I had difficulty with deductions when they ask for main and aux rope lifting off of boom

    • @LoadChartLab
      @LoadChartLab  6 ปีที่แล้ว +2

      Don't know if this helps, but the auxiliary and main wire rope for the Grove TLL is the same rope-- same construction and for the purpose of CCO exam its weight is 1 pound per foot. If you are picking off the extension with the auxiliary (it would be a single part line) and you have 10 feet hanging off the main boom, you would not have a deduction for the single part you're using but would deduct the weight of the rope hanging off the main boom. Lets say you have four parts hanging off the main, 10 feet, the deduction would be 10 (feet hanging) times 4 (number of parts) times 1 (pounds per foot) and would be 40 pounds.

    • @A.J.PMotivation
      @A.J.PMotivation 6 ปีที่แล้ว

      Thank you very much.i know we're I went wrong on the test

    • @LoadChartLab
      @LoadChartLab  6 ปีที่แล้ว

      Good deal. I'm not always able to respond very quickly but if you have any questions let me know. If you need to retake I would recommend doing it as soon as possible.

  • @NUCKINGfuts124
    @NUCKINGfuts124 3 ปีที่แล้ว

    At 7:00 why did you stop at 60 ft of boom and go over instead of 70ft?

    • @LoadChartLab
      @LoadChartLab  3 ปีที่แล้ว

      Using the range diagram the with a boom length of 70 and radius of 30 the tip to ground distance is 70 feet. It's where the 70" boom arc and 30 foot radius line intersect. The scale on left is tip to ground distance, on the right is boom length. I'm guessing you're looking at the 60 on the right of the range diagram?

    • @NUCKINGfuts124
      @NUCKINGfuts124 3 ปีที่แล้ว

      @@LoadChartLab Yes, thanks for clearing that up! I'm taking my mobile crane test this Friday so I'll be studying your videos until then. Thanks for posting them!

    • @LoadChartLab
      @LoadChartLab  3 ปีที่แล้ว

      @@NUCKINGfuts124 good luck on the exams.

  • @kidwray4313
    @kidwray4313 4 ปีที่แล้ว

    Gross load is plus deductions net is minus deductions

    • @LoadChartLab
      @LoadChartLab  4 ปีที่แล้ว

      Yes.

    • @LoadChartLab
      @LoadChartLab  4 ปีที่แล้ว

      Gross load is weight of object plus deductions. Net Capacity is gross capacity (Chart or line pull whichever is less) minus deductions. You are correct.

    • @LoadChartLab
      @LoadChartLab  4 ปีที่แล้ว

      Lot guys confuse gross load with gross capacity. Not the same thing.

    • @kidwray4313
      @kidwray4313 4 ปีที่แล้ว

      Load Chart Lab I just figured it out today thanks for posting these videos

  • @jeremysisk1489
    @jeremysisk1489 2 ปีที่แล้ว

    Hi I need your lattic practice test

    • @LoadChartLab
      @LoadChartLab  2 ปีที่แล้ว

      Hello Jeremy. They are available for purchase on Amazon. Go to Amazon search for Load Chart Laboratory.

    • @jeremysisk1489
      @jeremysisk1489 2 ปีที่แล้ว

      Did you ever come up with some core test material sir

    • @LoadChartLab
      @LoadChartLab  2 ปีที่แล้ว +1

      @@jeremysisk1489 I do have some core, practice questions. Send me your email address and I'll send it to you.