why you add 2 second timer into the pusher control? What's prepose of it? I thought the pusher is controlled by the preset number in the counter which is 2
thank you... my concern in the boxes are falling. is there a way thatnthe lifter will move down a little bit if a layer is in? can you integrate emcoder in the lifter? thank you very much.
or can we add a layer height sensor so that the boxes dont fall to high. when a layer is in the lifter moves down. and stops on negative trigger of layer sensor?? thank you sir
By default factory io has solution to this factory io has given us three outputs: 1) elevator move up 2) elevator move down 3) elevator move to limit When to turn On elevator up or down it moves one step only When you turn ON two outputs for example elevator up and elevator move to limit it will smooth go to upper limit at one go same for down.. So after loading 6 box turn ON only elevator down and it should move down only one step. But in my case sometimes my outputs were malfunctioning (software problem between factory io and tia portal output On in tia portal but not ON in factory io) so changed my process to above process.....
Watch Previous Video
> th-cam.com/video/7lEVqsFDDZM/w-d-xo.html&pp=gAQBiAQB
why you add 2 second timer into the pusher control? What's prepose of it? I thought the pusher is controlled by the preset number in the counter which is 2
thank you... my concern in the boxes are falling. is there a way thatnthe lifter will move down a little bit if a layer is in? can you integrate emcoder in the lifter? thank you very much.
Super thank you sir then could you please next make factory io converge station with Simens tia portal
or can we add a layer height sensor so that the boxes dont fall to high. when a layer is in the lifter moves down. and stops on negative trigger of layer sensor?? thank you sir
By default factory io has solution to this factory io has given us three outputs:
1) elevator move up
2) elevator move down
3) elevator move to limit
When to turn On elevator up or down it moves one step only
When you turn ON two outputs for example elevator up and elevator move to limit it will smooth go to upper limit at one go same for down..
So after loading 6 box turn ON only elevator down and it should move down only one step.
But in my case sometimes my outputs were malfunctioning (software problem between factory io and tia portal output On in tia portal but not ON in factory io)
so changed my process to above process.....
Super sir. What is the next video in factory io