DEATH TRAP CONSUMER UNIT - Electrician Life

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ส.ค. 2024

ความคิดเห็น • 222

  • @artisanelectrics
    @artisanelectrics  2 ปีที่แล้ว +15

    🧰🛠 Tool Of The Day 👇
    Unilite Pocket Light: amzn.to/3C0Agu7

    • @makg4655
      @makg4655 2 ปีที่แล้ว

      INSTALLATION OF EV MIGHT BE EASY .. BUT HOW ABOUT SAYING HOW DIFFERENT EARTHING SET UPS EFFECT IT . And / if additional earth rods might be needed for it .. also what rating of 32amp idle needed eg 6/10/30 kw

    • @matthewvincent9284
      @matthewvincent9284 2 ปีที่แล้ว

      Hyper volt sent us stainless steal templates for all our ev installers

    • @artisanelectrics
      @artisanelectrics  2 ปีที่แล้ว

      @@matthewvincent9284 yeah we have the same

  • @curtismal1726
    @curtismal1726 2 ปีที่แล้ว +33

    Funny that Corey mentioned he thinks the consumer unit is secondhand by the odd labels. My house used to have a crabtree c50 too and one of the MCB's was labelled up as "vending machine"

    • @TheOmegaRiddler
      @TheOmegaRiddler 2 ปีที่แล้ว +2

      phone the council and ask for your vending machine

  • @keithduthie
    @keithduthie 2 ปีที่แล้ว +29

    12:50 - Don't sell yourself short, Cory. As performing monkeys go, you're doing a bang-up job.

  • @SuperJoeyace1
    @SuperJoeyace1 2 ปีที่แล้ว +21

    Great channel and content. At first Cory wasn’t my cup of tea, but I was proved wrong long ago. He is a great professional and explains things patiently and with care. Great asset to the company. Excellent work. Keep those videos coming.

  • @shortcircuit7149
    @shortcircuit7149 ปีที่แล้ว +1

    Hi Cory. After over 40 years in the industry nothing surprises me now. All the time the DIY stores are supplying boards and any jo bloggs can buy one your going to get issues.

  • @bigjd2k
    @bigjd2k 2 ปีที่แล้ว +8

    You don’t actually need a bag in a Henry, the “membrane” filter stops dust. But be prepared to pull the filter out in a bin bag so the dust doesn’t go everywhere, and bang the filter out on a tree or post to get the dust out of it 😀

  • @philjones863
    @philjones863 2 ปีที่แล้ว +3

    Just started watching this channel over the last week, I'm not in the trade but this is enjoyable viewing. Cory from 5:00...I'm always incredibly impressed by leaders who can readily admit they don't know something. It's a strong statement of character. Best wishes from Sydney, Australia.

  • @OkenWS
    @OkenWS 2 ปีที่แล้ว +5

    Having worked on the meters for 3 years, I cannot STAND henley 2-tier blocks. Luckily SSE was using 5-way Lucy blocks which you would wire up Line and Neutral separately and they were far, far easier to work with and didn't break as often. The same cannot be said for our isolators. Bet every spark out there has sheared the screw on the top cover of the new Wylex isolators.

  • @jdaley197931
    @jdaley197931 2 ปีที่แล้ว +1

    Credit to you for venturing into the old crabtree unit. A useful lesson to be learned about checking all connections. I suspect whoever installed the small consumer unit for the submain neglected to check if the tails were secure in the crabtree unit.

  • @rexeady4325
    @rexeady4325 2 ปีที่แล้ว +9

    Cory, I still have a tin of that asbestos filler powder in my workshop. Must be over 40 years old now, and I haven’t touched it for decades. It was made by Rawplug, and came in an orange tin. It was good stuff in it’s day, and as the apprentice I always had to mix it up with spit - ahh the good ‘ole days!!

    • @GodmanchesterGoblin
      @GodmanchesterGoblin 2 ปีที่แล้ว

      I remember that too. We always had some in the toolbox at home in the 60s and 70s. Rolled it with a little spit in the palm of a hand and then squeezed it into the hole ready for the screw.

  • @mattlee3044
    @mattlee3044 2 ปีที่แล้ว +1

    Fantastic spot that the lights flickered when you wiggled a tail, great testing technique ! Impressive that you went after it, and fixed it. Entertaining and impressive video. Also learned about the plasticiser leeching issue from soft polystyrenes. So, educational, too.
    Next door left their house, turned the power off, then simply cut an external IP65 plug socket from the wall, snipping through the supply, which they poked back flush with the wall. Next contractor in turned on the power, and left it on. Dry day.
    When it next rained, we had our own lightening show and explosions from the live supply end of the external plug cable. All resolved with a call to the new owner, and no-one hurt - but REALLY ! You can’t write this stuff.

  • @RutlandG1zz
    @RutlandG1zz 2 ปีที่แล้ว +1

    BS88 blowing is always a brown trouser moment :) ... the march of time, love it :)

  • @Gr33nMamba
    @Gr33nMamba 2 ปีที่แล้ว +6

    I might be missing something here, but if you're a regular installer of Hypervolt, surely they could issue you a plastic/metal template to keep in your kit & use every time. I imagine they are under pressure to cut down on unnecessary packaging. Surely there are more professional installers than DIY purchases.

  • @vjaceslavprants6258
    @vjaceslavprants6258 ปีที่แล้ว

    For that type of installation in a pitch-black electrical storage room, I would recommend an LED head torch band. Absolutely brilliant, both hands are free and as bright as day. Good job though as always!

  • @mathman0101
    @mathman0101 2 ปีที่แล้ว +3

    Here is a tip no charge Artisan😇. Before you do any work for any consumer you do a week of electrical data logging on usage by putting CT clamps on for a week. That way you have a great sense of the load usage and can really dial in the installation. It will provide you with more options and be confident with any additions that the installation is not going to be compromised by your additions. Moreover that extra step is in line with the Artisan way going above and beyond.

    • @petermichaelgreen
      @petermichaelgreen 2 ปีที่แล้ว +2

      If the house has gas heating and the EV charger has a correctly configured grid limit there are highly unlikely to be any overloading issues even with a main fuse of "only" 60A.

    • @heladas90
      @heladas90 2 ปีที่แล้ว

      If you put a CT on then why would you need to know the houses usage

    • @bramcoteelectrical1088
      @bramcoteelectrical1088 2 ปีที่แล้ว +2

      too much messing about...busy sparkies have jobs to get to

    • @mathman0101
      @mathman0101 2 ปีที่แล้ว

      @@bramcoteelectrical1088 😂 yep not for a standard install unless you go above and beyond. I do suspect when you do repair a property in the future with more DC smart devices, solar, EV and various other power needs - power quality issues are going to be become important and it will become an important part of future testing. At that point the busy sparky will be even busier.

  • @antonarasanastasopoulos3482
    @antonarasanastasopoulos3482 2 ปีที่แล้ว +3

    That reddy reddy tail almost got as a firework surprise ...cory what's out man better put on some insulated gloves on some of those ...we want more of yours😂..take care ,keep doing it ,we love it.

  • @grahamek86
    @grahamek86 2 ปีที่แล้ว +19

    To be fair, the regs are pretty solid. Britain has some of the best electrical safety regulations on the planet. The problem is the lazy cheap buggers that refuse to follow them

    • @johnchristmas7522
      @johnchristmas7522 2 ปีที่แล้ว

      That they may be but I used to be an Industrial electrical Technician and when all the immigrants come over from Europe they were given J.I.B CARDS for nothing! One guy I confronted, because he didn't know how to connect up a plug, openly admitted, in his country he was a farm labourer! So there are plenty out there, not qualified at all. Regs is one thing, but when it comes down to. cost cost cost all kinds of corners were cut.

    • @grahamek86
      @grahamek86 2 ปีที่แล้ว +1

      @@johnchristmas7522 yeah you can see that now with the quality of the new builds in the UK. Snagging lists as long as Santas Naughty List.

    • @AJ-tj7jm
      @AJ-tj7jm ปีที่แล้ว

      ​@john christmas We even harmonised our cable colours to European standards to make it easier for them, when Red meaning both live and danger being the most sensible. Red Yellow and Blue being vibrant clearly distinguishable colours to identify phases, are now brown black and grey. So what was once the colour to identify a live phase conductor is now the neutral and what was the neutral is now a phase. Brown is now a line conductor which many moons ago would have been the earth and probably still is in other parts of the world, the wonderful logic spawned from the EU never ceases to amaze.

  • @ewsclass6679
    @ewsclass6679 2 ปีที่แล้ว +33

    That trunking on the neighbours wall during Cory's moan section 😂

    • @titmando1199
      @titmando1199 2 ปีที่แล้ว

      I couldn't help but notice that horrific sight as well 😂😂

    • @chrishewlet5471
      @chrishewlet5471 2 ปีที่แล้ว

      So I wasn't the only one.

  • @jayktee96
    @jayktee96 2 ปีที่แล้ว +3

    I don't remember Rawlpugs made from asbestos, they were always brown fibre, there was an asbestos type loose in a tin which you had to moisten and roll into shape to fit the hole- I think it was called Philliplug. In my apprenticeship days we always used a Rawlplug tool and a hammer, could take 10 minutes to make a 1½" x8 hole, Rawlplug started to make 'Durium' drills around 1965, my boss had one No.8, he used to keep it in the safe!! I think they cost about 6/- (30p) then.

  • @heladas90
    @heladas90 2 ปีที่แล้ว +2

    Also for anyone needing to install a Type A RCD on a charger install, FuseBox do a miniature RCBO which is Double Pole.

  • @AS19283
    @AS19283 2 ปีที่แล้ว +2

    For estimating I think I saved about 20 hrs per month by having them send photos in. Even if some needed tweaked those quotes either eliminated customers quickly or got people booked in even with the caveat that costs may change if we found crazy stuff.

  • @michaelboyes4948
    @michaelboyes4948 2 ปีที่แล้ว +3

    Great video as per, one thing you should always do before re-inserting the main cutout fuse is a short circuit test, this will indicate whether or not you've accidentally put a line or neutral conductor in the wrong terminal of the Henley block.
    To do a short circuit test use your voltage indicator and go between both contacts where the fuse carrier sits in the service head if your probs light up saying there's 230v then you've mixed your polarity in your Henley block

    • @brad30
      @brad30 2 ปีที่แล้ว

      🤭 That's definitely due to experience 🤣

    • @michaelboyes4948
      @michaelboyes4948 2 ปีที่แล้ว +2

      @@brad30 nahh thats how meter maids and dno are taught to insert the fuse

    • @brad30
      @brad30 2 ปีที่แล้ว

      @@michaelboyes4948 I thought you might have nearly blown yourself once upon a time

    • @michaelboyes4948
      @michaelboyes4948 2 ปีที่แล้ว +1

      @@brad30 ahh nah I always triple check what I do 🤣

    • @michaelboyes4948
      @michaelboyes4948 2 ปีที่แล้ว

      @@MrEnixa no you wouldn't you'd get a lighting bolt warning signal if your testers have single pole voltage indication, If you use Drummond tester it won't light up which is what you want

  • @jamesdean8864
    @jamesdean8864 11 หลายเดือนก่อน

    One thing to add - is the property on a linked connection for the main power line coming into the property

  • @FinlaysFireSystemsElectrical
    @FinlaysFireSystemsElectrical 2 ปีที่แล้ว +2

    Wow cant believe that tail was hanging out like that, it was a fire waiting to happen. Great vid!

  • @MICKEYISLOWD
    @MICKEYISLOWD 2 ปีที่แล้ว

    Hoover bags excite you...for me the sight of the hoover terrifies me.

  • @danmuygallo
    @danmuygallo ปีที่แล้ว

    "Let me know if you've ever done this...
    I was digging out a hole with my vacuum cleaner"
    😂

  • @havoctrousers
    @havoctrousers 2 ปีที่แล้ว

    Still got a 3 phase C50 board in service (also second hand). The breakers only have a magnetic trip, no thermal but they still comply. You don't need RCD protection on earthed armoured cable (522.6.204), so as long as you're putting a board in the garden with an RCD main switch and your EV charger has an RCD you could technically come off that old C50. Not that I'd want to either :D

  • @heladas90
    @heladas90 2 ปีที่แล้ว +2

    As standard we are fitting SPDs on all EV installs and would definitely be fitting SWA in a driveway.

    • @andytap560
      @andytap560 2 ปีที่แล้ว

      Definitely SWA around door too

  • @smartchip
    @smartchip 2 ปีที่แล้ว +1

    This guy is a clone of my best bud who also is a electrician, Stuart, he is hilarious and always happy,
    I used to say Henry blok,when I was a young en, everyone knew what I meant, did not correct me, lol,
    "I have safely isolated 'don't ask me how" sssssshhhhhh,
    23:40, Oyeah part P came about because a mp' s daughter passed away in uni digs, so yeah, the guy on the video is spot on, good lad,

  • @lonewolfgeoff
    @lonewolfgeoff 2 ปีที่แล้ว +4

    well found corey! that was a hell of an accident waiting to happen! nice work as per usual 😊

  • @davidfaraday7963
    @davidfaraday7963 2 ปีที่แล้ว +1

    I used asbestos rawlplugs at one time as my Dad had a tin of it which I inherited. As it was both easy to use and effective it was a good system (apart from the minor matter of the health hazard!)

  • @ianbird6997
    @ianbird6997 2 ปีที่แล้ว +1

    Wow Cory that was fing close, surprised the hadn’t caught fire 😲
    Great work again Sir 👍

  • @brandonturton6304
    @brandonturton6304 2 ปีที่แล้ว

    Refrence method B for bash it in... gave me a good chuckle

  • @mdshovel
    @mdshovel 2 ปีที่แล้ว

    That vacuum mounted on the SDS - I've had them on order for 4 months with Dewalt !! We get a lot of pre-2000 Artex and it looks like the best solution .... when I can get it

  • @richardjones5255
    @richardjones5255 2 ปีที่แล้ว

    No one can remember everything, but knowing that something should meet a regulation and how to check the requirement, then doing it the right way, is pretty much the battle won.

  • @nickrundall
    @nickrundall 2 ปีที่แล้ว +1

    Great video Cory, more of the wider process to the instal is exactly what I want to see.

  • @tc6907
    @tc6907 2 ปีที่แล้ว +4

    So Jordan… What has been your greatest business decision to date?
    Jordan - “ Hiring Cory “

    • @makg4655
      @makg4655 2 ปีที่แล้ว

      & RUBEN & NOW LEE … also not showing the paperwork needed for jobs eg RAMS ,METHOD STATEMENTS, completed certs etc etc

  • @paradoxni
    @paradoxni 2 ปีที่แล้ว +3

    Anyone watch these who isn't an electrician? Just wondering if it's just me that likes watching folks do interesting and high quality work? Not an electrician, no interest in being one or even DIYing it (petrified of electricity). So yea, I'm weird. Anyone else!? :)

    • @Adamwarren27
      @Adamwarren27 2 ปีที่แล้ว

      Same here

    • @deewat9618
      @deewat9618 2 ปีที่แล้ว

      Me too....

    • @bramcoteelectrical1088
      @bramcoteelectrical1088 2 ปีที่แล้ว

      I am a NICEIC sparky and Corey does lovely quality work he should be proud if himself top lad

  • @electrician247
    @electrician247 2 ปีที่แล้ว +1

    Nice video Corey. So true installing these is easy, simple radial. Thanks for sharing

  • @eamonnohalloran2254
    @eamonnohalloran2254 2 ปีที่แล้ว +4

    "O my Giddy Aunt"
    "The inevitable march of Time"
    Corey you are in the Zone drinking from the Cup of Life.
    Enjoy every minute. AGAIN GREAT VIDEO.
    Give Gretta a shout.

  • @pantysaer
    @pantysaer 2 ปีที่แล้ว +7

    I want to see a video about how to dig a hole with a Henry

  • @jdickson242
    @jdickson242 2 ปีที่แล้ว

    Best form of knowledge is knowing when you don't know but knowing where to know lolol

  • @metrotechguru5863
    @metrotechguru5863 2 ปีที่แล้ว +2

    Cory is a true super hero.

  • @AmosMoses777
    @AmosMoses777 2 ปีที่แล้ว

    Good point about the PRS. Unfortunately, until someone starts actually enforcing some of the regs (electrical and otherwise) that are being brought in it only costs the good landlords. The bad ones don't do the work and get away with it.
    Ace channel!

  • @solidus784
    @solidus784 2 ปีที่แล้ว +1

    It's funny hearing you talk about the state of regs in England. I'm in Ireland and if anything the regs are over the top in some cases eg. cable sizes but ye do have some crazy stuff like going on a short course and bang you are now an electrician how that is a thing just blows my mind.

    • @artisanelectrics
      @artisanelectrics  2 ปีที่แล้ว

      Totally

    • @bramcoteelectrical1088
      @bramcoteelectrical1088 2 ปีที่แล้ว

      this is thank god all stopping... the new CPD
      continued personal development you have to do for Napit and NICEIC is increasing the quality of workmanship now and not a day 🙄 sooner...

    • @solidus784
      @solidus784 2 ปีที่แล้ว

      @@bramcoteelectrical1088 I didn't know that, thanks

  • @johnchristmas7522
    @johnchristmas7522 2 ปีที่แล้ว

    I've come across a house wired in bell wire! Many years ago I admit but hey it was cheap!! Even the old mauve twin twisted flex, stapled to the wall, with the excess nailed to the ceiling!
    Our term was its a wet string job!

  • @donzotv1667
    @donzotv1667 2 ปีที่แล้ว

    Just as an FYI there is a EV install check list in the Code of practice 4th edition for EVCP installs in the back of the book.. it really helps

  • @tommymack3210
    @tommymack3210 2 ปีที่แล้ว +4

    really good video, appreciated this different video Cory

  • @alanwalton5735
    @alanwalton5735 11 หลายเดือนก่อน

    With all the regs electricains go by. Have you noticed that other trades don't bother or their regs have lower z
    Standards. A few times fire ro escape routes have been mentioned. Did anyone notice gas pipe around building. Plastic clips?

  • @Teaspoonlizard
    @Teaspoonlizard 2 ปีที่แล้ว

    I need to get my house inspected - can you do a video showing what an inspection involves? Interested but will also mean I can ensure whoever is conducting the inspection is doing it correctly!

  • @philipsmith0752
    @philipsmith0752 2 ปีที่แล้ว +1

    there was a long nail in the rise of the stairs and Corys head was all most on it a few times . but interesting video. heath and safety

  • @Snartifartblast
    @Snartifartblast 2 ปีที่แล้ว

    Really good job you didn't bash the back of your head on one of those nails under the stairs.

  • @callumrowley2203
    @callumrowley2203 2 ปีที่แล้ว +1

    Corey get the 4 fingered kitkats at Costco get 24 for less than a tenner. Don't keep the whole pack in your van though or you'll turn into a big unit like me.

  • @Distinctly.Average
    @Distinctly.Average 2 ปีที่แล้ว +3

    Electrics aside, the frightening part was the nails sticking out of the wall behind your head. I was cringing at the thought of a noggin-nail interface moment.

  • @RichardArblaster
    @RichardArblaster 2 ปีที่แล้ว

    Great job, good job you checked the connection on that switch 😮😮😮

  • @bobbobby5724
    @bobbobby5724 2 ปีที่แล้ว +1

    What a master.

  • @nathanhedgeley8016
    @nathanhedgeley8016 2 ปีที่แล้ว +4

    Cory what's the model of blakladder trousers you usually wear? I'm looking to get a pair 👍

    • @rayc1503
      @rayc1503 2 ปีที่แล้ว

      Try the X1900 stretch 1999 super comfortable. I've got 1 different variants of them now. A little pricey but blow snickers out the windows. The Englebert Strauss e.s motion denim look pretty similar to what Corey's wearing they were pretty good but I've gone off denim now.

  • @m.bmaintenance7834
    @m.bmaintenance7834 2 ปีที่แล้ว +1

    well said Cory on the state of the industry, i get sick off saying because nobody seems to listen, oh and the pixies removed the cut out when you was at the van or they do mine

  • @rattlehead85
    @rattlehead85 2 ปีที่แล้ว +3

    Nice Vid as always Corey.
    Sadly until they close the “open to interpretation” nonsense that always gets used to excuse shoddy work, you’ll always be dealing with crap like that bad connection inside that widow maker board.
    Also the ongoing joke that still exists regarding electrical engineers legally pulling a main fuse to permit safe isolation needs to be sorted out. 🤟🏻🤟🏻

    • @JasperJanssen
      @JasperJanssen 2 ปีที่แล้ว

      I don’t think there’s any open to interpretation that would make *that* okay - but there’s also the fact that it’s just been there forever. It’s entirely possible that it was tight, or at least more or less tight, when it was installed (and of course that was pre-torque settings). All the other screws on the board Cory checked were also getting an extra quarter turn or so. Things just loosen up over time (to be more accurate, over thermal cycles - that’s why the main tails got it worst) and as long as the regs assume “as long as nobody touches it it’s going to remain okay if it was okay at one time” this can happen.
      Not sure how you could fix that, especially given that most electricians wouldn’t want to certify this as safe, or probably even as “as safe as it could be given that it is to 1965 standard”, and yet mandatory replacements of anything but the very oldest crap is a hard sell.
      Here in the Netherlands, pulling the main fuse is straight up allowed, but *reinstalling* it is where you need a certified electrician that can put a seal in with his personal number on it, who also certifies that the entire consumer unit area is up to standards (but not necessarily the rest of the house).

  • @tspirit99
    @tspirit99 ปีที่แล้ว

    Older consumer units don't have the greatest grip on tails... you should know by moving the tails, you'll loosen them.

  • @davidfaraday7963
    @davidfaraday7963 2 ปีที่แล้ว

    Yes, Henley is a brand name. They make cut-out fuseholders as well as other stuff.

  • @jaycee1980
    @jaycee1980 2 ปีที่แล้ว

    22:25 i think a short bad enough to blow an 60-100A fuse right in front of them wouldve wrecked anyone's trousers ;)

  • @mumblingsole
    @mumblingsole 2 ปีที่แล้ว

    Great content as always. If you wasn't far away I get you to rewire our house next year.

  • @pinchermartyn3959
    @pinchermartyn3959 2 ปีที่แล้ว

    Useful info. Thanks. Awesome channel.

  • @oldbutstillcurious3615
    @oldbutstillcurious3615 2 ปีที่แล้ว +3

    ? Is crossing the cables in a Henly block less 'explosive' with a TN-S supply, reversed polarity is definitely a no-no - particularly bad if left undetected.

  • @paullefur6213
    @paullefur6213 ปีที่แล้ว

    great vlog watching all your vlogs now, did you know there was a dirty great big nail just above your head

  • @coralbay00
    @coralbay00 2 ปีที่แล้ว +1

    Top spark. Love your videos 🤝

  • @Thats_Mr_Random_Person_to_you
    @Thats_Mr_Random_Person_to_you 2 ปีที่แล้ว

    You are right that changes do need to be made (in the rental sector as at the end of the day the landlord IS responsible for providing a property that won't burn down.......). It's sad that changes have been made, but already they are useless...
    The idea of forcing EICRs to be done in rented properties is, in theory, a good way to solve the issue. Landlords learn if their wiring is safe and what changes need to be made, prospective tenants can see if the wiring is safe before moving in (creating a market force for improvement) etc etc etc... and if something goes wrong the landlord has more liability if they ignored EICR recommendations etc... HOWEVER...... due to crappy trade body rules every man and his dog can sign an EICR these days and they are just not worth the paper they are written on.
    The person who did ours didn't unplug anything before doing r1+r2 etc.. admitted that he was odd jobbing for his mate and not an actual on the trades spark day in day out etc... (i can't control who the agent working on behalf of the landlord picks).
    A change that if well implemented could have led to changes has been turned into another paper filling exercise that isn't fit for purpose.

    • @petermichaelgreen
      @petermichaelgreen 2 ปีที่แล้ว +1

      On the one hand, the government took the lazy way out. Rather than building a proper specification for what exactly landlord electrical checks should consist of and who exactly should do them they just wrote a vague law and left it up to people to interpret it.
      On the other hand I do belive that it has been an overall positive for the state of electrics in rental properties. Yes there are chartalans passing stuff that should probably fail* or worse issuing outright fraudulent certificates, but there are also many properties getting their first look from someone competent in a long time.
      * Though there is no official list of fail criteria.............................

  • @shaunlewis286
    @shaunlewis286 2 ปีที่แล้ว

    fibre wall plugs aren't asbestos mate . you will be handling them. Jute cotten and glue, no damage to you

  • @Waynesworldofgaming
    @Waynesworldofgaming 2 ปีที่แล้ว

    👏🏻👏🏻👏🏻 top workmanship as always

  • @engdarfatgalalyelectrical1076
    @engdarfatgalalyelectrical1076 2 ปีที่แล้ว

    Your information is good

  • @nigelconnor2460
    @nigelconnor2460 2 ปีที่แล้ว

    excellent wee video! Thanks for this!

  • @tonyclarkthesailingspark1509
    @tonyclarkthesailingspark1509 2 ปีที่แล้ว

    I Guess the reason you don’t use a head torch is you cant show off your new short back & side’s?

  • @tommahoney7940
    @tommahoney7940 2 ปีที่แล้ว

    Great watch Cory.

  • @angryscottishidiot
    @angryscottishidiot 2 ปีที่แล้ว +8

    "If it's not educational then I might as well stop it now." :( Educational or not, the entertainment value of these videos alone should be enough to keep you going. I am not an electrician and I am addicted. Better and less bull-shitty than anything TV has to offer. Please don't speak such scary words again. Every job you do has something different - I have binged several EV installs and it never gets boring. Nothing wrong with being a performing monkey. Monkeys are fun.

  • @SproutyPottedPlant
    @SproutyPottedPlant 2 ปีที่แล้ว +1

    Unilite ❤️ much better than a phone torch and they do high CRI!!!!!

  • @davehill7398
    @davehill7398 2 ปีที่แล้ว +2

    Are you using fire rated clips for the cable run outside? Also, what are your thoughts on fitting plastic sub boards outside near the intake cabinet?

    • @jix177
      @jix177 2 ปีที่แล้ว

      Would you need them on something so close to ground level? ie there wouldn't be a risk of it falling on someone or obstructing an escape route. Not disagreeing, just interested too.

  • @paulosoares
    @paulosoares 2 ปีที่แล้ว

    Did anyone else notice put the inspection date the same as the installation date?

  • @oyleyhands1332
    @oyleyhands1332 2 ปีที่แล้ว

    Just an observation, I did not see a DP meter isolation switch in there, if you were connecting into a Henley block, or repacing it, that main fuse would have to have 'fallen' out at some point, would it not,? for you to make your connections?
    That wall plug you were hesitant to touch looked like a mushroomed head of the old wooden Rawlplug... yes, the word Rawlplug has an 'L' in it as it is the company name, all the rest are wall plugs or expansion wall plugs... it aint 'Rawplug'
    That product you mentioned that contained asbestos was also a Rawplug product and it was named 'Rawlplastic'
    Originally a British company named after John Joseph Rawlings, original plugs were a mixture of jute fibres soaked in glue and animals blood !! I only discovered that last fact when checking if the company was still British, just now.

  • @thefallenangel2
    @thefallenangel2 2 ปีที่แล้ว

    Those c50 single phase boards are lethal. Probably owner was ex nhs or water board where there are still thousands of those boards in service and nicked off a job. Breakers in the board are worth a few quid just as blanks let alone functional equipment

    • @bramcoteelectrical1088
      @bramcoteelectrical1088 2 ปีที่แล้ว

      definitely my mate had rcd version it exploded and nearly took his eye out with the explosion it was the old metal clad craptree with rcd as main switch...be warned ..

    • @rowanNClangley
      @rowanNClangley 2 ปีที่แล้ว

      Met one on an EICR, lovely un-shrouded inputs on main switch. Some consequential operation limitations on the testing side as I am not putting my fingers or tools anywhere near that. Especially after finding such a good Ze and high PSCC value.
      The BANG which that loose line tail could generate on contact with the metal does not bear too much though

  • @saschastevenson1231
    @saschastevenson1231 2 ปีที่แล้ว

    Great Video guys, good catch with that tail.

  • @johannjoubert1592
    @johannjoubert1592 ปีที่แล้ว

    Love the videos💪💪💪

  • @BakedTuber
    @BakedTuber 2 ปีที่แล้ว

    Definitely a candidate for a new CU at that property. Should of let them know it was a false economy to install yet another sub main.

  • @carlseddon2392
    @carlseddon2392 2 ปีที่แล้ว

    Excellent as normal

  • @muffinmonster8511
    @muffinmonster8511 2 ปีที่แล้ว +1

    U get a reusable Henry bags on Amazon for under 5 quid cable ties are too expensive to keep using 🤣😂

  • @jgharston
    @jgharston ปีที่แล้ว

    Yeah, unexpected circuits can be simple with a bit of thought. Some years ago a potter wanted me to wire up his electric kiln. WTF? A kiln? But a bit of research and essentially, treat it as a commercial cooker. So, max current draw with no diversity. Simple.

  • @andrewpowell6457
    @andrewpowell6457 2 ปีที่แล้ว

    Cory well explained

  • @hudatahseen3568
    @hudatahseen3568 2 ปีที่แล้ว

    Brilliant video as usual 👍

  • @jstokvis
    @jstokvis 2 ปีที่แล้ว

    Excellent

  • @Deiphobuzz
    @Deiphobuzz 2 ปีที่แล้ว

    Get yourself an easyroller dude. Cable comes off nice and straight, no loops.

  • @JasperJanssen
    @JasperJanssen 2 ปีที่แล้ว

    Holy shit, the residents are lucky their house hasn’t burned down.

  • @sanregal
    @sanregal 2 ปีที่แล้ว +1

    Hei Cory, greetings from Romania. I really appreciate your content,a lot of things to learn . Maybe in the future you can share with us how are you doing quotes and surveys for bigger jobs ? Thanks you and keep up the good job!!

  • @bobturner3645
    @bobturner3645 ปีที่แล้ว

    what manufacturer of workbench is Cory using ?

  • @cuezed
    @cuezed 2 ปีที่แล้ว

    I want that torch 🔦
    Edit. I just seen the link. Thanks

  • @AndyFletcherX31
    @AndyFletcherX31 2 ปีที่แล้ว

    As it was a rented property there must be a current EICR on the place. I'm betting there isn't because if there is how the fsck did they not see the loose incomer?

  • @Ad-gn8pl
    @Ad-gn8pl 2 ปีที่แล้ว +1

    So work have told me my next company car is a pure EV. Not ideal for the type of journeys I do but hey ho. They will fit a charger though. Which one should I be urging them to fit?

    • @peterthomas9440
      @peterthomas9440 2 ปีที่แล้ว

      Also going for company EV through octopus - only nice option is a zappy v2 from what I’ve seen that comes free install with car. Have to pay for a Anderson :-)

    • @Ad-gn8pl
      @Ad-gn8pl 2 ปีที่แล้ว

      @@peterthomas9440 Interesting, what sort of journeys do you do? Some of mine can be up to 200miles + the my list is fairly limited so probably an Audi Q4. The guy at Audi told me to get used to hanging around charging points. 😬

    • @bramcoteelectrical1088
      @bramcoteelectrical1088 2 ปีที่แล้ว

      zappy...lovely unit

  • @tomslaytor116
    @tomslaytor116 8 หลายเดือนก่อน

    “Coolio sparkys paradise” I see what you did there very punny

  • @wayneseidel3725
    @wayneseidel3725 2 ปีที่แล้ว

    What are those clips for the armoured cable called? I been looking everywhere for them.

  • @pwaelectricalltd29
    @pwaelectricalltd29 2 ปีที่แล้ว

    Another great video 👍

  • @azeemgammaryanay
    @azeemgammaryanay 2 ปีที่แล้ว

    Hi im one of ur Biggest fan been watching ur videos quite few months. But did not realise that i did not subscribe ur channel which i did now. Im from birmingham and im Domestic Electrician Big Big fan of Artisan electrics. Plz if u ever come to Birmingham Give me the opportunity to offer you a Dinner and meet u guys. Love and Support from your fan.