Inverter Refrigerator Compressor Direct Start & UVW Testing | Embraco Fridge Board

แชร์
ฝัง
  • เผยแพร่เมื่อ 12 ม.ค. 2025

ความคิดเห็น • 89

  • @nols3726
    @nols3726 ปีที่แล้ว +2

    I have a inverter fridge 30 cubic 5 yrs ago it just stop cool. My technician said I need a compressor and Control Board. I am in Carribbean I buy it at pc Richard USA. I am learning you explain it so good I understand very well.

  • @conradogoodwin8077
    @conradogoodwin8077 ปีที่แล้ว +11

    Incredibly clear explanations, thanks!

    • @forevertechenglish
      @forevertechenglish  ปีที่แล้ว

      You're very welcome!

    • @wasimedoo7994
      @wasimedoo7994 ปีที่แล้ว

      Is there any way else to start and run the invertor compressor with out the board if the board damage

  • @troubleshooter1975
    @troubleshooter1975 ปีที่แล้ว

    Very good video. I learned a lot!
    Only mentioning some minor technical, or translation errors so that no one gets confused:
    @3:30 Just to clarify, the inverter board generates "3-phase" AC power, in the vicinity of 230VAC [not DC].
    @TheNYgolfer also posted this already - thank you.
    I'm not sure what he is showing in the drawing of a board output waveform, but there are many excellent diagrams of 3-phase power on the internet.
    As he drew that, it would represent a single phase (of the three).
    [It also slopes 'backwards in time' at one place, but it is hand drawn. I just didn't understand what aspect he is illustrating.]
    @4:45 To clarify, he is using 240VAC, not DC, to power the board. Brown is more properly referred to as 'hot' or 'live', and not 'positive', which is misleading and can be confused with DC where the term 'positive' actually means 'positive' DC polarity.
    [I also came across someone calling the live as 'phase', and the other as neutral.]
    He has 240VAC showing on his meter, but refers to it as 220V; doesn't matter -they rate them for 220V-240V input anyway.
    [What country are you in fine sir?]
    I only mention it because I have had some people get confused by voltage ratings...
    1:40
    3:09
    3:57
    Mr K L

  • @broncheemims8493
    @broncheemims8493 2 ปีที่แล้ว +5

    Sir I like the way you explain things electrically. I have a degree in electronics,so it helps troubleshoot the board more accurate.

  • @Goughk
    @Goughk 2 หลายเดือนก่อน +2

    Thank you so much.have to learn so much from you😢

  • @vadimtyutyunnik353
    @vadimtyutyunnik353 2 ปีที่แล้ว +5

    You said at 3:40 - it works on 220VDC 40-160Hz.
    Why we call it DC when it has some frequency??

    • @TheNYgolfer
      @TheNYgolfer ปีที่แล้ว +1

      He misspoke. He meant 220VAC.

  • @josecarlosmejia9632
    @josecarlosmejia9632 11 หลายเดือนก่อน

    GREAT INFORMATION FOR IMPLEMENT ON SCHOOL OF TECHNICIANS ABOUT INVERTES THANK YOU

  • @debdymilanez9418
    @debdymilanez9418 ปีที่แล้ว +2

    Parabéns pelas explicações 👏👏👏👏🇧🇷🇧🇷🇧🇷🇧🇷🇧🇷🇧🇷

  • @francoisguyot9770
    @francoisguyot9770 ปีที่แล้ว +1

    Just the info I needed.! Thx

  • @robeltsegaye1505
    @robeltsegaye1505 ปีที่แล้ว +2

    Thanks 4 the uvw tester im using it its effective if u can i would like u to explain winding of washing machine motor and how to know the truns of the burned coil and the other thing is this week i bought fixit ic programmer please make some videos how to install the fixit programmer software on pc and where to find the programs

  • @tambejohn7382
    @tambejohn7382 ปีที่แล้ว +2

    Thanks alot for the lessons

  • @tesfahungetahunargachew4328
    @tesfahungetahunargachew4328 2 ปีที่แล้ว +1

    Tnx sir for your presentation have a good new year

  • @sofroniocarranza6064
    @sofroniocarranza6064 ปีที่แล้ว +3

    Thank you for all you done I seen your mother board trouble shooting is a near place where to buy New mother board of Samsung inverter how much cost most client rush to fix.

    • @forevertechenglish
      @forevertechenglish  ปีที่แล้ว

      This A Good question But I Usually repair them, Buying a new one you could ask the samsung's service center for the motherboard

  • @SilvioTomazdeAquinoTomaz-sc2mi
    @SilvioTomazdeAquinoTomaz-sc2mi 11 หลายเดือนก่อน +1

    Know a lot, congratulations!

  • @ugochukwu-uf6iv
    @ugochukwu-uf6iv ปีที่แล้ว +2

    Thanks very rich in content sir

  • @katchutarao4313
    @katchutarao4313 ปีที่แล้ว

    This video very use full thank you sar

  • @strimearts6998
    @strimearts6998 10 หลายเดือนก่อน +1

    Hello, great video.
    I have a gn162430x - 5645512900 Inverter PCB. Is there a way to start it manually? My compressor seems to be fine, just there is no volatage output at the UVW pins. thank you

  • @uru-freemind7711
    @uru-freemind7711 7 หลายเดือนก่อน +2

    Los motores trifásicos se pueden operar como monofásicos con capacitores... Se podría operar el motor inverter con capacitores sin placa?

  • @16valve64
    @16valve64 2 ปีที่แล้ว +2

    Thanks a lot for sharing your thoughts

  • @venkateswarludantha6702
    @venkateswarludantha6702 ปีที่แล้ว +3

    Hi sir very nice video. Iam venkatesh 🇮🇳india

  • @rolanddejesus8685
    @rolanddejesus8685 2 ปีที่แล้ว +1

    thanks a lot sir for sharing...God bless.

  • @charlesnokae6987
    @charlesnokae6987 ปีที่แล้ว +1

    Your explanation is very helpful 💯👍🏾.
    Please would you please kindly help me out with a Cubigel Compressor - NUT125FSC is not working and it's PCB green led light blinking and my colleagues were assuming that the compressor is faulty due to voltage changes during startup and compressor not cut in.

    • @forevertechenglish
      @forevertechenglish  ปีที่แล้ว

      Send me its Pictures with diagram on my social media

  • @jaybala7493
    @jaybala7493 2 ปีที่แล้ว +2

    Sir thank you very much

  • @godalmighty-lm2yt
    @godalmighty-lm2yt ปีที่แล้ว +2

    Please I like the way you explain things, am a Technician in refrigeration and air conditioning and also washing machine aspects but sir I have little problem with HITACHI twin refrigerator, The compressor will start and goes off immediately please may I know the courses of this problem .
    Emmanuel.

    • @forevertechenglish
      @forevertechenglish  ปีที่แล้ว

      Well dear I could not say anything this way, But if this refrigerator has a PCB board, it could be faulty, Check for a lose wiring connections, check the compressor, the relay. If everythings ok, If it has a PCB, Then the PCB board could be bad. Let me know then.

  • @AnUnapologeticApologist
    @AnUnapologeticApologist ปีที่แล้ว +1

    If you have the inverter connected normally, except for the female connectors that connect to the compressor windings, once the unit is plugged in what voltage should you expect to see from the female connector on any lead to another? My condenser fan will power on but the compressor will not. Resistance is good on every winding, no short to ground. Power from the female connector that goes to compressor reads 14VAC applied. I believe the inverter is the issue

  • @ferozenoordeen3711
    @ferozenoordeen3711 2 ปีที่แล้ว +3

    Thanks for the training...
    Please explain the input DC voltage to the compressor in your next lesson .
    Regards...

  • @muhammadatifsafdar
    @muhammadatifsafdar 7 หลายเดือนก่อน

    Much informative!!

  • @HeartyLindo
    @HeartyLindo ปีที่แล้ว +1

    How about the single wire from speed switch it is the same?also connect in neutral the red wire from speed switch?

  • @mikefreedom5612
    @mikefreedom5612 2 ปีที่แล้ว +2

    Thank you
    How can I get that boarx?

  • @abdohajj5135
    @abdohajj5135 ปีที่แล้ว

    Nice thx to you❤❤❤

  • @ateseteknik621
    @ateseteknik621 4 หลายเดือนก่อน

    Merhaba videolarımız Çok bilgilendirici ancak size bir şey sormak istiyorum kırmızı kablonun yanındaki siyah kabloya anakarttan kaç volt geliyor acaba ya da o siyah kablo ile anakart arasındaki iletişim hakkında da bir video çekerseniz çok memnun olurum Saygılarımla

  • @thomasoconnor-cs3ee
    @thomasoconnor-cs3ee 6 หลายเดือนก่อน

    So when you join the 2 points of the optocoupler the thermostat doesnt need to be connected?

  • @nick-firstest
    @nick-firstest ปีที่แล้ว +1

    Is regular gas generator(without inverter) can run refrigerator without any harm?

    • @forevertechenglish
      @forevertechenglish  ปีที่แล้ว

      Yes it do run the refrigerator without any harm, But it is not Bill or electricity friendly.

  • @Adam90155
    @Adam90155 ปีที่แล้ว +2

    Super film 😁gdzie moge kupic taka płytke sterującą?

    • @Waldemar_Pachol_official
      @Waldemar_Pachol_official ปีที่แล้ว +1

      Fejk! Film ukradziony z indyjskiego kanału. Płytka też fejkowa - brak modułu SD30Mxxxx.

    • @Adam90155
      @Adam90155 ปีที่แล้ว

      ​@@Waldemar_Pachol_officialwitam może Pan wie gdzie mogę kupić płytke sterująca sprężarkę inwertorową na krótko? Pozdrawiam

  • @mhandrabat331
    @mhandrabat331 ปีที่แล้ว +2

    سلآم عليكم ورحمة الله وبركاته استادي الكريم هل ممكن تشغيل الضاغط انفرتر بدون كارت الكنترول

  • @SZahi-hi6ew
    @SZahi-hi6ew 2 หลายเดือนก่อน

    What type of of PCB board you are using with best regards

  • @martingates6501
    @martingates6501 ปีที่แล้ว

    One question, I'm testing an LG inverter compressor like you did in this video and the compressor start and everything's ok, but the discharge is too weak, it's because doesn't has refrigerant or the compressor is not good?

  • @zawrialangosman6804
    @zawrialangosman6804 2 ปีที่แล้ว +2

    Best video

  • @hadjnabil4811
    @hadjnabil4811 ปีที่แล้ว +1

    than you lot's😘

  • @SNBBank
    @SNBBank 4 หลายเดือนก่อน

    I have one question same way to check dc fcu fan moter also

  • @gerryyulo
    @gerryyulo 10 หลายเดือนก่อน

    The voltage on the 220v compressor reads only 150v coming from the inverter of Electrolux freezer-fridge, what do you think seems to be the problem, can it be on the inverter module or on the main module? I'm a DYI'er

  • @seshachary5580
    @seshachary5580 10 หลายเดือนก่อน +1

    very educative. Thank you

  • @muhammedaflah7920
    @muhammedaflah7920 19 วันที่ผ่านมา

    How to check linear inverter compressor.how its circuit on pcb?

  • @kumudiniwasanthi1952
    @kumudiniwasanthi1952 ปีที่แล้ว +1

    Super

  • @jgc12154631
    @jgc12154631 4 หลายเดือนก่อน

    This inverter board can't change the frequency? Just on & off?

  • @harunrashid8796
    @harunrashid8796 ปีที่แล้ว

    Thanks a lot.

  • @RecoveryAccount-k4z
    @RecoveryAccount-k4z หลายเดือนก่อน

    Nice sir

  • @odrixscaba3519
    @odrixscaba3519 หลายเดือนก่อน

    Where can i send my board to fix to you

  • @softsilver2346
    @softsilver2346 2 ปีที่แล้ว +2

    Good

  • @hugocornejo5757
    @hugocornejo5757 ปีที่แล้ว

    Cómo saber de qué lado puentear el optoaclopador?

  • @anassyria5176
    @anassyria5176 10 หลายเดือนก่อน

    Hello sir from Syria
    Is it safe to run a refrigerator with inverter-driven compressor with a square wave AC?

  • @negasheshetu5627
    @negasheshetu5627 2 หลายเดือนก่อน

    Thanks allot

  • @lasanthabandara7455
    @lasanthabandara7455 2 ปีที่แล้ว +3

    How to check the timer side to see if the timer is working properly

    • @forevertechenglish
      @forevertechenglish  2 ปีที่แล้ว

      Dear in the video we do not talk about any timer we talking about thermostat if you want to know about thermostat let me know

  • @nhiduong1040
    @nhiduong1040 3 หลายเดือนก่อน

    Thanks

  • @JaysonPagador-gd5mm
    @JaysonPagador-gd5mm 10 หลายเดือนก่อน

    How can I find the compressor wuv no sign in compressor sir

  • @EveSherman-x1j
    @EveSherman-x1j 3 หลายเดือนก่อน

    Dulce Forges

  • @sonu.labrez
    @sonu.labrez 2 ปีที่แล้ว +1

    sir ye video hindi me dalo na

  • @LibbyMarshal-r1h
    @LibbyMarshal-r1h 4 หลายเดือนก่อน

    Thomas Sandra Lee Sandra Lopez Betty

  • @wasimedoo7994
    @wasimedoo7994 ปีที่แล้ว +2

    Good information friend but I don't get any part to replace on that board but I saw a video on tube some guys run the invertor compressor with acopositor 4uf and 220 vote can it work thanks God bless 👍

    • @troubleshooter1975
      @troubleshooter1975 ปีที่แล้ว

      Yes, testing a 3-phase motor on single phase power 'can' be done, in certain circumstances (with a capacitor sized properly for the motor being tested).
      BUT, the power will be badly unbalanced, and power factor and currents will be way off from safe design ratings. (another words, the current through the windings will not match, will likely be excessive, and the timing of the current flow will be out of sync - it will be 'out-of-step' with the rotation!).
      [also, if you phase it wrong, the motor WILL run backwards... It may run fine, but not oil itself!]
      This almost always will create excess heating of the motor, quickly overloading it.
      You could possibly burn it out in minutes!
      Test it this way only long enough to determine that it is rotating and producing flow and pressure (like a few seconds to half a minute). -To confirm that the motor can run...
      Then find the other reason the motor is not getting proper power.
      Mr K L

  • @marcmondragone3452
    @marcmondragone3452 12 วันที่ผ่านมา

    The coils look like the flux capacitor.

  • @martineseddington4908
    @martineseddington4908 3 หลายเดือนก่อน

    58799 Mosciski Trail

  • @LMR5826
    @LMR5826 ปีที่แล้ว

    Quality Distributor #2 Westminster Road.kingston. all inverter Parts are there.