Inverter Refrigerator Dc Compressor UVW Testing In 3 Steps

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 มี.ค. 2022
  • In this video, I have shown you how to test an Inverter refrigerator dc compressor UVW with a multimeter with overload wires in simple steps. What should be the correct values on the multimeter and its body test? The compressor test we did is of a Samsung inverter refrigerator.
    ******************************************************************************
    Products You Might Be Interested to Buy
    Multimeters
    NEOTECK Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dml...
    ANENG Q1 Digital Multimeter ➡️ s.click.aliexpress.com/e/_DeU...
    Digital Pen Multimeter ➡️s.click.aliexpress.com/e/_DkM...
    Rechargeable Smart Multimeter ➡️s.click.aliexpress.com/e/_DDm...
    UNI-T UT181A True RMS Auto Range Multimeter ➡️ s.click.aliexpress.com/e/_DFL...
    ANENG 616 Large Screen Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dln...
    TOOLTOP ET8135 True RMS Multimeter ➡️s.click.aliexpress.com/e/_DB8...
    MASTECH MS8910 Digital Multimeter ➡️ s.click.aliexpress.com/e/_Ded...
    ZOYI ZT-X Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dd9...
    ANENG Q1 Digital Multimeter 9999 Analog Tester ➡️ s.click.aliexpress.com/e/_DEz...
    Thermal Camera
    UNI-T UTI260B HD 256X192 Thermal Camera ➡️ s.click.aliexpress.com/e/_Deo...
    TOOLTOP ET692Cl Thermal Imaging Camera ➡️ s.click.aliexpress.com/e/_Dm0...
    Mileseey TR120E Infrared Thermal Imager ➡️ s.click.aliexpress.com/e/_Dej...
    Fluke TiS55+ Thermal Camera 9HZ ➡️ s.click.aliexpress.com/e/_DCO...
    Noyafa NF 522 523 Handheld Infrared Thermal ➡️ s.click.aliexpress.com/e/_DCe...
    TOOLTOP T7 256*192 Android Thermal Imager ➡️ s.click.aliexpress.com/e/_DmB...
    Soldering Wires
    10Pcs 2mm XZZ-2015 Desoldering ➡️ s.click.aliexpress.com/e/_Dkg...
    0.8mm/1.0mm 50g Lead Free Solder➡️ s.click.aliexpress.com/e/_DDn...
    0.6/0.8mm 50g/100g Lead Free Solder➡️ s.click.aliexpress.com/e/_DDC...
    200g 500g Tin Wire Soldering Wire ➡️ s.click.aliexpress.com/e/_DdQ...
    8g 50g Per Roll High Purity Soldering Wire➡️ s.click.aliexpress.com/e/_DCm...
    250m/roll 30AWG UL1423 Insulation Cable Copper➡️ s.click.aliexpress.com/e/_Deu...
    Vacuum Pump
    18V Lithium Battery Vacuum Pump ➡️ s.click.aliexpress.com/e/_DDK...
    VEVOR 2.5CFM Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkT...
    Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkH...
    VEVOR 1.8-4.8CFM Refrigerant Vacuum Pump➡️ s.click.aliexpress.com/e/_DeA...
    Mani Fold Gauge
    Digital Manifolds Refrigerant Gauge ➡️ s.click.aliexpress.com/e/_DC3...
    R410A R22 R134a R404A Manifold Gauge ➡️ s.click.aliexpress.com/e/_DeB...
    Refrigerant pressure gauge ➡️ s.click.aliexpress.com/e/_Ddg...
    500/800PSI Refrigerant Manometer ➡️ s.click.aliexpress.com/e/_Dne...
    HONGSEN HS-330 Refrigeration Vacuum ➡️ s.click.aliexpress.com/e/_DBi...
    Air Condition Gauge Manifold ➡️ s.click.aliexpress.com/e/_DFu...
    MRCARTOOL L202 Air Conditioner ➡️ s.click.aliexpress.com/e/_Dkg...
    Soldering stations
    RF4-H2 Automatic Sleep SMD ➡️ s.click.aliexpress.com/e/_DBa...
    JCD 2 in 1 Soldering Station LCD Digital Display➡️ s.click.aliexpress.com/e/_DFz...
    GVDA New Soldering Station ➡️s.click.aliexpress.com/e/_DDc...
    JCD 8586 Soldering Station 2 In 1 Digital➡️ s.click.aliexpress.com/e/_DBX...
    SUGON T21 Soldering Station ➡️ s.click.aliexpress.com/e/_Dne...
    AIFEN A5 Pro Soldering Station ➡️ s.click.aliexpress.com/e/_Dns...
    JCD 750W 2 in 1 Soldering Station LCD Digital➡️ s.click.aliexpress.com/e/_Dl1...
    UYUE T210 Soldering Station LED Digital➡️ s.click.aliexpress.com/e/_DeI...
    Soldering Stations MECHANIC➡️ s.click.aliexpress.com/e/_DmW...
    Desoldering pumps
    LUXIANZI 30w/40w Powerful Electric Desoldering ➡️ s.click.aliexpress.com/e/_DkV...
    Desoldering Pump Suction Tin Gun ➡️ s.click.aliexpress.com/e/_De1...
    110V/220V Electric Tin Suction Sucker Pen ➡️ s.click.aliexpress.com/e/_Ddu...
    Gaqqee 220v 36w Electric Solder ➡️ s.click.aliexpress.com/e/_Dkg...
    ******************************************************************************
    Subscribe to The Channel 👉 bit.ly/3vNT7s3
    Social Links
    Facebook 👉 / forevertech3
    Instagram 👉 / forever_tech1
    Twitter 👉 / forevertech3
    #invertercompressor #refrigerator #compressor #dc #testing #multimeter

ความคิดเห็น • 106

  • @selimfolksong
    @selimfolksong 8 หลายเดือนก่อน +5

    I am fridge technician I understand your video my name is Sheikh Selim Uddin. From India thank you so much

    • @thangsgo6938
      @thangsgo6938 7 หลายเดือนก่อน

      Hi brother I have doubt , recently I bought new fridge single door now I'm looking compressor it was have dent and pump,this is danger or its ok pls tell me

  • @joeabad5908
    @joeabad5908 11 หลายเดือนก่อน +5

    Nice to know how common things around us works..
    Thank you for the upload..

  • @ViegoMisterio
    @ViegoMisterio 12 วันที่ผ่านมา

    Hi, thank for the information, it really helps. Got a question, can I connect directly the two cables of the overload ? Just to see if the system is working?

  • @gurglejug627
    @gurglejug627 4 หลายเดือนก่อน

    Hi, thanks for your videos. How does one know how much refrigerant to put in a fridge when recharging after a rebuild/modification?

  • @elkunkhaliil
    @elkunkhaliil ปีที่แล้ว +3

    Thank you Sir for you efforts to make these videos, i am knew at this and it helps a lot.
    Could you please make a video explaining all parts of the PCP Board and what they do?. Thanks again

  • @acetech9237
    @acetech9237 ปีที่แล้ว +2

    You're awesome. I'm a Mercedes Benz tech but I'm always happy to learn more

  • @burhan-00
    @burhan-00 2 ปีที่แล้ว +2

    Merci beaucoup

  • @ANGIEB52
    @ANGIEB52 10 หลายเดือนก่อน +1

    This is the best video for these variable systems… now I know for sure I’m on the right track … 😁 Thank you ..

  • @rolanddejesus8685
    @rolanddejesus8685 11 หลายเดือนก่อน +2

    thanks very much sir for sharing,God bless.

  • @wasimedoo7994
    @wasimedoo7994 2 ปีที่แล้ว +1

    Very good information

  • @ravidu2309
    @ravidu2309 7 หลายเดือนก่อน

    Useful program thanks

  • @NDUGOD
    @NDUGOD 11 หลายเดือนก่อน +2

    Thanks for the simplification of daunting challenges. Excellent💯👌👌👌👌

  • @mehboobhassan2157
    @mehboobhassan2157 11 หลายเดือนก่อน

    very good information

  • @naveengopagani361
    @naveengopagani361 ปีที่แล้ว +3

    🤝Exlent Explan 👍 TQ Sir

  • @Zindagi851
    @Zindagi851 7 หลายเดือนก่อน +1

    This is really good information .thanks

  • @abcdefg8336
    @abcdefg8336 9 หลายเดือนก่อน +1

    Thanks for shsring, and how about the rest of the three wires?

  • @grahamswain7356
    @grahamswain7356 7 หลายเดือนก่อน +1

    Very useful information

    • @tbone6354
      @tbone6354 หลายเดือนก่อน

      It is cheaper to flush with water then no need to vacuum. And add 50ml of sulphuric acid to the compressor

  • @tesfahungetahunargachew4328
    @tesfahungetahunargachew4328 ปีที่แล้ว +1

    Nice explaning

  • @lapovanie
    @lapovanie 27 วันที่ผ่านมา

    I checked the winding/housing short circuit - no short circuit. I measured the winding resistances and in each case I got 0.0Ω. What could have happened? The compressor is 12V DC

  • @jaybala7493
    @jaybala7493 ปีที่แล้ว +1

    Thanks sir

  • @davidharrison6789
    @davidharrison6789 ปีที่แล้ว +4

    Hallo I have notice that compressor winding it has a problem from that measurement you have shown us

    • @davidg.9942
      @davidg.9942 4 หลายเดือนก่อน

      Hi, it is inverter compressor, it has to have identical reading in all 3 points. It is not a typical C S R with 50-60 Hz where you Identify Common Start & Run readings. Inverter compressor runs on 40- to about 180 Hz on 240v and thus to see if compressor winding is still good reading has to be identical or within 0.1-0.2 ohm on all 3 connections. Body short you check the same way as old one.

  • @patriciamateo1733
    @patriciamateo1733 ปีที่แล้ว +3

    VERY USEFUL, AWESOME

  • @AbdurRahim-ir9yz
    @AbdurRahim-ir9yz 10 หลายเดือนก่อน +1

    nice Explain ❤

  • @johnsutter1497
    @johnsutter1497 5 หลายเดือนก่อน

    We had a flood in the basement. Both fans on the refridgidaire refrigerator work. The compressor does not come on. Could it be the overload switch? Thank you

  • @innocenthumans3721
    @innocenthumans3721 ปีที่แล้ว +1

    Pcb light blinks twice. N pcb is ok technician said compressor needs replacement where as compressor showws right reading. Can u help

  • @colbinbarrita288
    @colbinbarrita288 2 หลายเดือนก่อน

    My ref standby 3 years,coz no frozen and cold,possible can I repair to function!thanks

  • @hassanyusuf7280
    @hassanyusuf7280 11 หลายเดือนก่อน +1

    thank you

  • @GodknowsSumaina
    @GodknowsSumaina 2 หลายเดือนก่อน

    What will be the problem if the compressor winding reads ok and we have 120 volts on the compressor terminal a d the compressor doesn’t want to run; the overload is fine

  • @thomasaquinas6628
    @thomasaquinas6628 8 หลายเดือนก่อน +1

    ok- i have a samsung refrigerator. The "DC" is not correct I think. The compressor is marked "240V 3 phase." That means the inverter board is putting out 3 phase voltage, that is the 3 wires will have all 3 wires have the same voltage between each pair. An inverter doesn't make DC, that would be called a rectifier. The inverter makes 3 phase so the motor doesn't have to have a starting capacitor which can fail. Three phase motors are more reliable than single phase motors. Single phase power is what you have at your house, 120/240V single phase. The inverter turns that into three phase.

  • @michaelyawkal4592
    @michaelyawkal4592 ปีที่แล้ว +1

    Nice

  • @NiceRepairGuys
    @NiceRepairGuys 2 หลายเดือนก่อน +1

    Good to know

  • @haleelah5818
    @haleelah5818 9 หลายเดือนก่อน +1

    Super

  • @GodknowsSumaina
    @GodknowsSumaina 2 หลายเดือนก่อน

    I have exactly this fridge with an inverter compressor, the overload is ok, the re is power on the compressor terminals , the winding resistance is ok but the the compressor won’t run; what should I do to get it running? Thanks

    • @forevertechenglish
      @forevertechenglish  2 หลายเดือนก่อน

      is circuit board showing any errror blinking

  • @tbone6354
    @tbone6354 3 หลายเดือนก่อน

    A good idea is to fill the compressor with water before regassing to reduce corrosion

  • @abuasfur7334
    @abuasfur7334 4 หลายเดือนก่อน

    Hello I done all the checks everything is ok but the overload is rattling when it is shaken is that normal?

  • @jonathanrobinson5348
    @jonathanrobinson5348 10 หลายเดือนก่อน

    I have a Samsung fridge family hub model rf265beaesr it was working but suddenly when you plugged it the compressor sounds like star running then shut down right away, then the touch screen have a code 84c compressor locked over RPM. Then the compressor you can hear that it's running but very slow you barely can hear it. But nothing nothing its working inside the fridge. What can I do?

    • @forevertechenglish
      @forevertechenglish  10 หลายเดือนก่อน +1

      First of all check the compressor, As I have told in the video. If the compressor is ok. Look for the any wire that's been lose connection or cut attached with the compressor. If everything is ok. If you have another compressor attach that with the motherboard to verify that the motherboard is good. If you attach that new compressor and it works. Means your old compressor is bad. And need replacement.

    • @MBihon2000
      @MBihon2000 7 หลายเดือนก่อน +1

      Buy a new replacement.

  • @user-saadmahdi
    @user-saadmahdi ปีที่แล้ว +1

    What types of motor
    Induction or BLDC

    • @forevertechenglish
      @forevertechenglish  ปีที่แล้ว +1

      Dear, I didn't saw it from the inside, maybe will do a video on it.

    • @user-saadmahdi
      @user-saadmahdi ปีที่แล้ว

      @@forevertechenglish
      Thanks

  • @halimsaid5718
    @halimsaid5718 7 หลายเดือนก่อน

    سلام ممكن تحدث عن ثلاجة lg smart inverter وشكرا وميض 8 مرات

  • @Defectordrunkzone
    @Defectordrunkzone 9 หลายเดือนก่อน +2

    How is that possible?
    The terminals should have different values.
    If so how could someone identify which terminal is which?

    • @tonyp6088
      @tonyp6088 5 หลายเดือนก่อน +1

      You are absolutely correct. There are 3 terminal pins, 2 windings within the compressor which are connected to the common terminal, (which is usually the pin at the top).
      If you measure from the bottom left pin to the top pin that will give you the resistance of the start winding.
      Bottom right pin to top pin will give you resistance of the run winding. And the bottom two pins together will give you the total resistance of both windings as they are both connected internally to the common (top pin).
      All values should be different but check manufacturers specifications to be sure.

    • @davidg.9942
      @davidg.9942 4 หลายเดือนก่อน +1

      Hi, it is inverter compressor, it has to have identical reading in all 3 points. It is not a typical C S R with 50-60 Hz where you Identify Common Start & Run readings. Inverter compressor runs on 40- to about 180 Hz on 240v and thus to see if compressor winding is still good reading has to be identical or within 0.1-0.2 ohm on all 3 connections. Body short you check the same way as old one.

  • @thangsgo6938
    @thangsgo6938 7 หลายเดือนก่อน

    Hi brother I have doubt , recently I bought new fridge single door now I'm looking compressor it was have dent and pump,this is danger or its ok pls tell me

    • @forevertechenglish
      @forevertechenglish  7 หลายเดือนก่อน

      What kind of dent the compressor has?

  • @abdulrasheed3424
    @abdulrasheed3424 8 หลายเดือนก่อน

    So inverter compressor working in dc voltage?

  • @lnglng6961
    @lnglng6961 5 หลายเดือนก่อน

    ❤❤❤

  • @crazysquirrel9425
    @crazysquirrel9425 11 หลายเดือนก่อน +4

    Just another reason to avoid any refrigerator that has electronics in it.
    Far too many points of failure. And those boards are very EXPENSIVE, IF you can even get one when you need it.

    • @MBihon2000
      @MBihon2000 7 หลายเดือนก่อน +1

      You can't find a ref with no electronics board on it. Unless you are buying a 70 year old ref.

    • @crazysquirrel9425
      @crazysquirrel9425 7 หลายเดือนก่อน

      @@MBihon2000 My refrigerator certainly is not 70 years old.
      Closer to 25-30 years old maybe.
      I have converted refrigerators from electronics to mechanical many times.
      Electronics ones lasted a year or so. Mechanical conversions are still working even today.
      If I can find a decent one with coils up the back, I would get it.
      Less moving parts and no electronics.

    • @louisdreyer7523
      @louisdreyer7523 3 หลายเดือนก่อน +1

      Agree 100%

    • @crazysquirrel9425
      @crazysquirrel9425 3 หลายเดือนก่อน

      @@MBihon2000 Some refrigerators can be converted back to non electronic.
      Ever hear of a non electric refrigerator?

  • @user-ly2zu2mx7s
    @user-ly2zu2mx7s 2 หลายเดือนก่อน

    There are always the reasons behind why electrical failures happen. Without explaining them, such as the large resistance difference in this case, your fixing skills do not get any further.

  • @LuchambeeLuchambee
    @LuchambeeLuchambee 8 หลายเดือนก่อน

    Chequeo de refrigerador

  • @ilkertokgoz2465
    @ilkertokgoz2465 ปีที่แล้ว +1

    Thanks

  • @fritzmoise178
    @fritzmoise178 8 หลายเดือนก่อน

    Can I have a price for this compressor

  • @ArtPIsMe
    @ArtPIsMe 3 วันที่ผ่านมา

    3:08 Why does it not show the sum of the resistance of the two windings?
    You explained how to check resistance in another video and there should be sum like 12.5 Om + 12.5 Om = 25 Om
    th-cam.com/video/b27m71B8J4s/w-d-xo.html

  • @BhalaneDlamini
    @BhalaneDlamini 7 หลายเดือนก่อน

    My fridge does not get cool but deepfridge section is alright

    • @forevertechenglish
      @forevertechenglish  7 หลายเดือนก่อน

      is it a deep freezer?

    • @BhalaneDlamini
      @BhalaneDlamini 7 หลายเดือนก่อน

      @@forevertechenglish no it is a fridge not a deepfridge

    • @forevertechenglish
      @forevertechenglish  7 หลายเดือนก่อน

      @@BhalaneDlamini ok

    • @forevertechenglish
      @forevertechenglish  7 หลายเดือนก่อน

      You mean freezer is ok but fridge section is not cooling

  • @sonu.labrez
    @sonu.labrez 2 ปีที่แล้ว

    Sir isko Hindi me ap batate na

    • @forevertechenglish
      @forevertechenglish  2 ปีที่แล้ว

      We have Already made a video on this topic in Hindi visit channel forever tech
      Or video link th-cam.com/video/9uM8mXaSKeU/w-d-xo.html

  • @MajidKhan-gi7my
    @MajidKhan-gi7my 2 ปีที่แล้ว +1

    Ustad g ap apna num to day Mara ap se kam hai urgent

    • @forevertechenglish
      @forevertechenglish  2 ปีที่แล้ว

      th-cam.com/video/oUV8s4q9lt8/w-d-xo.html
      Is video main mera no majood hai

  • @ramasamyramachandran5847
    @ramasamyramachandran5847 2 ปีที่แล้ว +1

    Translate in tamil pls

  • @louisdreyer7523
    @louisdreyer7523 3 หลายเดือนก่อน +1

    The best method of testing a compressor is with a Megger. Two faults occur on a compressor are : winding to winding short and winding to chassis. A normal multimeters' voltage goes up to 9 volt. Where a meggers' voltage goes up to a 1000v. When testing with a Megger you won't go higher than 500v. So a megger is much better to use.

    • @forevertechenglish
      @forevertechenglish  3 หลายเดือนก่อน +1

      I already have made a video on megger and the multimeter posted on the channel

  • @user-kj1od5ed7p
    @user-kj1od5ed7p หลายเดือนก่อน +2

    You should get somebody that's very fluent in English to make sure you get the best computer voice translation from text

    • @forevertechenglish
      @forevertechenglish  หลายเดือนก่อน

      This is an old video; you can check out some of the new ones. They have better voiceovers.

    • @nadeem5476
      @nadeem5476 หลายเดือนก่อน

      why English????
      learn Chinese or his language.
      2 H W English

    • @user-kj1od5ed7p
      @user-kj1od5ed7p หลายเดือนก่อน

      @@nadeem5476 whatever floats your boat my comment was criticizing the quality of the text to speech artificial intelligence voice system or whatever he was using

  • @user-kj1od5ed7p
    @user-kj1od5ed7p หลายเดือนก่อน

    Why do you use a crappy computer voice

  • @CFPVideoProductions
    @CFPVideoProductions 3 หลายเดือนก่อน

    Please use real people to do your voiceovers. This robot should be deleated. Your products are depending on the warmth and proper human voice and not an AI monotone presentation.

  • @kettogeerman174
    @kettogeerman174 6 หลายเดือนก่อน

    I have Never heard of a threephase D.C. motor. Stop teaching "NONSENCE" D.C. does not have frequency. A.C. has frequency. Where have you bent to school? What a"SHAME"

    • @forevertechenglish
      @forevertechenglish  6 หลายเดือนก่อน +2

      3 phase refers to the number of electrical phase windings on the motor. It is switched via a 3-phase power "bridge" from a DC voltage supply. This "bridge" consists of 6 power devices - normally IGBTs, but sometimes MOSFETs. They use pulse-width modulation to control the power, and the order in which the 3 motor phases are energized determines the direction of rotation.

    • @forevertechenglish
      @forevertechenglish  6 หลายเดือนก่อน +1

      The terms AC and DC can describe signals as well. An AC signal is a current, voltage, or numerical sequence that consistently exhibits both positive and negative values, and a DC signal exhibits only positive values or only negative values.

  • @vettalan
    @vettalan ปีที่แล้ว +2

    Bro,that is not overload.it is overload protector