Inverter Refrigerator Dc Compressor UVW Testing In 3 Steps

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ม.ค. 2025

ความคิดเห็น • 136

  • @selimfolksong
    @selimfolksong ปีที่แล้ว +12

    I am fridge technician I understand your video my name is Sheikh Selim Uddin. From India thank you so much

    • @thangsgo6938
      @thangsgo6938 ปีที่แล้ว

      Hi brother I have doubt , recently I bought new fridge single door now I'm looking compressor it was have dent and pump,this is danger or its ok pls tell me

  • @teesaeed6529
    @teesaeed6529 2 หลายเดือนก่อน +2

    Thank you very much for such a good video it is very clear to understand. I have problem with my Samsung RFG297AARS the compressor is not coming on at all the fan is running , I tried to follow the diagnostic steps from your video , everything is fine except "3:09 to 3:55" when I check the compressor's coil resistance I got only 0.84 ohm , any suggestion what it could be and how to resolve it. Thanks again for your time

    • @thecrim22
      @thecrim22 หลายเดือนก่อน

      Did you get this sorted as i have a faulty fridge and the same readings as you

    • @teesaeed6529
      @teesaeed6529 หลายเดือนก่อน +1

      @@thecrim22 Yes it was the converter board (the smaller one) I replaced it and now it is working like before. I am so happy about coz there have been two gentlemen to tell me two different "faults". One was telling the compressor is gone and it is expensive to replace it the next was telling me there "should"(what means he is not sure about) be a small leak and there is no more coolant in system so because of this compressor can't come ON . and and and . Luckily I found the board for very reasonable price and swap was a piece of cake. Good Luck

  • @thomasaquinas6628
    @thomasaquinas6628 ปีที่แล้ว +7

    ok- i have a samsung refrigerator. The "DC" is not correct I think. The compressor is marked "240V 3 phase." That means the inverter board is putting out 3 phase voltage, that is the 3 wires will have all 3 wires have the same voltage between each pair. An inverter doesn't make DC, that would be called a rectifier. The inverter makes 3 phase so the motor doesn't have to have a starting capacitor which can fail. Three phase motors are more reliable than single phase motors. Single phase power is what you have at your house, 120/240V single phase. The inverter turns that into three phase.

  • @acetech9237
    @acetech9237 ปีที่แล้ว +2

    You're awesome. I'm a Mercedes Benz tech but I'm always happy to learn more

  • @joeabad5908
    @joeabad5908 ปีที่แล้ว +6

    Nice to know how common things around us works..
    Thank you for the upload..

  • @ANGIEB52
    @ANGIEB52 ปีที่แล้ว +3

    This is the best video for these variable systems… now I know for sure I’m on the right track … 😁 Thank you ..

  • @naveengopagani361
    @naveengopagani361 ปีที่แล้ว +3

    🤝Exlent Explan 👍 TQ Sir

  • @davidharrison6789
    @davidharrison6789 ปีที่แล้ว +5

    Hallo I have notice that compressor winding it has a problem from that measurement you have shown us

    • @davidg.9942
      @davidg.9942 11 หลายเดือนก่อน +3

      Hi, it is inverter compressor, it has to have identical reading in all 3 points. It is not a typical C S R with 50-60 Hz where you Identify Common Start & Run readings. Inverter compressor runs on 40- to about 180 Hz on 240v and thus to see if compressor winding is still good reading has to be identical or within 0.1-0.2 ohm on all 3 connections. Body short you check the same way as old one.

  • @Zindagi851
    @Zindagi851 ปีที่แล้ว +1

    This is really good information .thanks

  • @elkunkhaliil
    @elkunkhaliil ปีที่แล้ว +3

    Thank you Sir for you efforts to make these videos, i am knew at this and it helps a lot.
    Could you please make a video explaining all parts of the PCP Board and what they do?. Thanks again

  • @rolanddejesus8685
    @rolanddejesus8685 ปีที่แล้ว +2

    thanks very much sir for sharing,God bless.

  • @muhammadammarraziqrosli1979
    @muhammadammarraziqrosli1979 2 หลายเดือนก่อน +1

    whats the different relay circle it same @ what?🤔

  • @NDUGOD
    @NDUGOD ปีที่แล้ว +2

    Thanks for the simplification of daunting challenges. Excellent💯👌👌👌👌

  • @grahamswain7356
    @grahamswain7356 ปีที่แล้ว +1

    Very useful information

    • @tbone6354
      @tbone6354 8 หลายเดือนก่อน

      It is cheaper to flush with water then no need to vacuum. And add 50ml of sulphuric acid to the compressor

  • @abcdefg8336
    @abcdefg8336 ปีที่แล้ว +1

    Thanks for shsring, and how about the rest of the three wires?

  • @gurglejug627
    @gurglejug627 11 หลายเดือนก่อน

    Hi, thanks for your videos. How does one know how much refrigerant to put in a fridge when recharging after a rebuild/modification?

  • @Shuris92
    @Shuris92 7 หลายเดือนก่อน

    Hi, thank for the information, it really helps. Got a question, can I connect directly the two cables of the overload ? Just to see if the system is working?

  • @AbdurRahim-ir9yz
    @AbdurRahim-ir9yz ปีที่แล้ว +1

    nice Explain ❤

  • @innocenthumans3721
    @innocenthumans3721 ปีที่แล้ว +1

    Pcb light blinks twice. N pcb is ok technician said compressor needs replacement where as compressor showws right reading. Can u help

  • @wasimedoo7994
    @wasimedoo7994 2 ปีที่แล้ว +1

    Very good information

  • @ravidu2309
    @ravidu2309 ปีที่แล้ว

    Useful program thanks

  • @lasanthabandara7455
    @lasanthabandara7455 4 หลายเดือนก่อน +1

    I need your advice i have liner compressor FMC088NAMA i need this refrigerator convert to nomal mode tell me this compressor to equal (MA72LHEG can i use this 134a gas compressor)

    • @forevertechenglish
      @forevertechenglish  4 หลายเดือนก่อน

      Well check the manuals, I could not recommand without seeing it physically, well you need to check the manuals of both the compressors and match it specifications with one another. If they are almost the same then go for the replacement.

  • @tesfahungetahunargachew4328
    @tesfahungetahunargachew4328 2 ปีที่แล้ว +1

    Nice explaning

  • @johnsutter1497
    @johnsutter1497 ปีที่แล้ว

    We had a flood in the basement. Both fans on the refridgidaire refrigerator work. The compressor does not come on. Could it be the overload switch? Thank you

  • @lapovanie
    @lapovanie 8 หลายเดือนก่อน

    I checked the winding/housing short circuit - no short circuit. I measured the winding resistances and in each case I got 0.0Ω. What could have happened? The compressor is 12V DC

  • @mehboobhassan2157
    @mehboobhassan2157 ปีที่แล้ว

    very good information

  • @tbone6354
    @tbone6354 10 หลายเดือนก่อน

    A good idea is to fill the compressor with water before regassing to reduce corrosion

  • @solomonakinwande8790
    @solomonakinwande8790 หลายเดือนก่อน

    Can you do a video from where all the wire is separated and then you join them together. Kindly explain in the video please

  • @burhan-00
    @burhan-00 2 ปีที่แล้ว +2

    Merci beaucoup

  • @GodknowsSumaina
    @GodknowsSumaina 9 หลายเดือนก่อน

    What will be the problem if the compressor winding reads ok and we have 120 volts on the compressor terminal a d the compressor doesn’t want to run; the overload is fine

  • @user-saadmahdi
    @user-saadmahdi 2 ปีที่แล้ว +1

    What types of motor
    Induction or BLDC

    • @forevertechenglish
      @forevertechenglish  2 ปีที่แล้ว +1

      Dear, I didn't saw it from the inside, maybe will do a video on it.

    • @user-saadmahdi
      @user-saadmahdi ปีที่แล้ว

      @@forevertechenglish
      Thanks

  • @GodknowsSumaina
    @GodknowsSumaina 9 หลายเดือนก่อน

    I have exactly this fridge with an inverter compressor, the overload is ok, the re is power on the compressor terminals , the winding resistance is ok but the the compressor won’t run; what should I do to get it running? Thanks

    • @forevertechenglish
      @forevertechenglish  9 หลายเดือนก่อน

      is circuit board showing any errror blinking

    • @marvinmagruder1067
      @marvinmagruder1067 6 หลายเดือนก่อน

      Make a starter box and put on the compressor. If it is good it will run. If not you have a different problem.

    • @Bizija123
      @Bizija123 6 หลายเดือนก่อน

      @@forevertechenglish I have samsung as well, compressor won't run. Both main board and inverter board blink once per few seconds. Thank you.

  • @colbinbarrita288
    @colbinbarrita288 9 หลายเดือนก่อน

    My ref standby 3 years,coz no frozen and cold,possible can I repair to function!thanks

  • @fcdelgado4043
    @fcdelgado4043 5 หลายเดือนก่อน

    Well explain not like other videos.

  • @hassanyusuf7280
    @hassanyusuf7280 ปีที่แล้ว +1

    thank you

  • @3AMRobin_bugha
    @3AMRobin_bugha 2 หลายเดือนก่อน

    Does that motor have copper in side

  • @patriciamateo1733
    @patriciamateo1733 2 ปีที่แล้ว +3

    VERY USEFUL, AWESOME

  • @Defectordrunkzone
    @Defectordrunkzone ปีที่แล้ว +2

    How is that possible?
    The terminals should have different values.
    If so how could someone identify which terminal is which?

    • @tonyp6088
      @tonyp6088 ปีที่แล้ว +3

      You are absolutely correct. There are 3 terminal pins, 2 windings within the compressor which are connected to the common terminal, (which is usually the pin at the top).
      If you measure from the bottom left pin to the top pin that will give you the resistance of the start winding.
      Bottom right pin to top pin will give you resistance of the run winding. And the bottom two pins together will give you the total resistance of both windings as they are both connected internally to the common (top pin).
      All values should be different but check manufacturers specifications to be sure.

    • @davidg.9942
      @davidg.9942 11 หลายเดือนก่อน +1

      Hi, it is inverter compressor, it has to have identical reading in all 3 points. It is not a typical C S R with 50-60 Hz where you Identify Common Start & Run readings. Inverter compressor runs on 40- to about 180 Hz on 240v and thus to see if compressor winding is still good reading has to be identical or within 0.1-0.2 ohm on all 3 connections. Body short you check the same way as old one.

    • @Defectordrunkzone
      @Defectordrunkzone 3 หลายเดือนก่อน

      @@davidg.9942 Thank you man,i appreciate it.

  • @tedthornton7791
    @tedthornton7791 6 หลายเดือนก่อน

    On the compressor
    1st pin was about 5.0
    2nd pin was about 12
    3rd pin was also about 12
    Does this indicate the compressor is good?

  • @dawitarega7677
    @dawitarega7677 21 ชั่วโมงที่ผ่านมา

    Thanks bro

  • @abuasfur7334
    @abuasfur7334 11 หลายเดือนก่อน

    Hello I done all the checks everything is ok but the overload is rattling when it is shaken is that normal?

  • @ilkertokgoz2465
    @ilkertokgoz2465 2 ปีที่แล้ว +1

    Thanks

  • @jonathanrobinson5348
    @jonathanrobinson5348 ปีที่แล้ว

    I have a Samsung fridge family hub model rf265beaesr it was working but suddenly when you plugged it the compressor sounds like star running then shut down right away, then the touch screen have a code 84c compressor locked over RPM. Then the compressor you can hear that it's running but very slow you barely can hear it. But nothing nothing its working inside the fridge. What can I do?

    • @forevertechenglish
      @forevertechenglish  ปีที่แล้ว +1

      First of all check the compressor, As I have told in the video. If the compressor is ok. Look for the any wire that's been lose connection or cut attached with the compressor. If everything is ok. If you have another compressor attach that with the motherboard to verify that the motherboard is good. If you attach that new compressor and it works. Means your old compressor is bad. And need replacement.

    • @MBihon2000
      @MBihon2000 ปีที่แล้ว +1

      Buy a new replacement.

  • @thangsgo6938
    @thangsgo6938 ปีที่แล้ว

    Hi brother I have doubt , recently I bought new fridge single door now I'm looking compressor it was have dent and pump,this is danger or its ok pls tell me

  • @janakadeepal1850
    @janakadeepal1850 5 หลายเดือนก่อน

    Thank you

  • @jaybala7493
    @jaybala7493 2 ปีที่แล้ว +1

    Thanks sir

  • @crazysquirrel9425
    @crazysquirrel9425 ปีที่แล้ว +4

    Just another reason to avoid any refrigerator that has electronics in it.
    Far too many points of failure. And those boards are very EXPENSIVE, IF you can even get one when you need it.

    • @MBihon2000
      @MBihon2000 ปีที่แล้ว +1

      You can't find a ref with no electronics board on it. Unless you are buying a 70 year old ref.

    • @crazysquirrel9425
      @crazysquirrel9425 ปีที่แล้ว

      @@MBihon2000 My refrigerator certainly is not 70 years old.
      Closer to 25-30 years old maybe.
      I have converted refrigerators from electronics to mechanical many times.
      Electronics ones lasted a year or so. Mechanical conversions are still working even today.
      If I can find a decent one with coils up the back, I would get it.
      Less moving parts and no electronics.

    • @louisdreyer7523
      @louisdreyer7523 10 หลายเดือนก่อน +1

      Agree 100%

    • @crazysquirrel9425
      @crazysquirrel9425 10 หลายเดือนก่อน

      @@MBihon2000 Some refrigerators can be converted back to non electronic.
      Ever hear of a non electric refrigerator?

  • @そしてあの時この場所で
    @そしてあの時この場所で 9 หลายเดือนก่อน

    There are always the reasons behind why electrical failures happen. Without explaining them, such as the large resistance difference in this case, your fixing skills do not get any further.

  • @michaelyawkal4592
    @michaelyawkal4592 ปีที่แล้ว +1

    Nice

  • @haleelah5818
    @haleelah5818 ปีที่แล้ว +1

    Super

  • @abdulrasheed3424
    @abdulrasheed3424 ปีที่แล้ว

    So inverter compressor working in dc voltage?

  • @NiceRepairGuys
    @NiceRepairGuys 9 หลายเดือนก่อน +1

    Good to know

  • @markdi2
    @markdi2 8 หลายเดือนก่อน +8

    You should get somebody that's very fluent in English to make sure you get the best computer voice translation from text

    • @forevertechenglish
      @forevertechenglish  8 หลายเดือนก่อน

      This is an old video; you can check out some of the new ones. They have better voiceovers.

    • @nadeem5476
      @nadeem5476 8 หลายเดือนก่อน

      why English????
      learn Chinese or his language.
      2 H W English

    • @markdi2
      @markdi2 8 หลายเดือนก่อน

      @@nadeem5476 whatever floats your boat my comment was criticizing the quality of the text to speech artificial intelligence voice system or whatever he was using

    • @jollyscaria1922
      @jollyscaria1922 6 หลายเดือนก่อน

      Unit volt moniter uvm checking power met checking rely winding teminsl ohmx conuvit testin good shorno testing realy point valve

    • @markdi2
      @markdi2 6 หลายเดือนก่อน

      @@jollyscaria1922 ok have a nice day

  • @UwemUdoibok
    @UwemUdoibok 3 หลายเดือนก่อน

    My refrigerator is bad what can I do

  • @ArtPIsMe
    @ArtPIsMe 7 หลายเดือนก่อน

    3:08 Why does it not show the sum of the resistance of the two windings?
    You explained how to check resistance in another video and there should be sum like 12.5 Om + 12.5 Om = 25 Om
    th-cam.com/video/b27m71B8J4s/w-d-xo.html

  • @halimsaid5718
    @halimsaid5718 ปีที่แล้ว

    سلام ممكن تحدث عن ثلاجة lg smart inverter وشكرا وميض 8 مرات

  • @fritzmoise178
    @fritzmoise178 ปีที่แล้ว

    Can I have a price for this compressor

  • @BhalaneDlamini
    @BhalaneDlamini ปีที่แล้ว

    My fridge does not get cool but deepfridge section is alright

  • @lnglng6961
    @lnglng6961 ปีที่แล้ว

    ❤❤❤

  • @louisdreyer7523
    @louisdreyer7523 10 หลายเดือนก่อน +1

    The best method of testing a compressor is with a Megger. Two faults occur on a compressor are : winding to winding short and winding to chassis. A normal multimeters' voltage goes up to 9 volt. Where a meggers' voltage goes up to a 1000v. When testing with a Megger you won't go higher than 500v. So a megger is much better to use.

    • @forevertechenglish
      @forevertechenglish  10 หลายเดือนก่อน +1

      I already have made a video on megger and the multimeter posted on the channel

  • @alfredtlhaka9563
    @alfredtlhaka9563 19 วันที่ผ่านมา

    My fridge is not freezer the compressor is hot

  • @Teshe-s4t
    @Teshe-s4t 3 หลายเดือนก่อน

    Wawu god

  • @LuchambeeLuchambee
    @LuchambeeLuchambee ปีที่แล้ว

    Chequeo de refrigerador

  • @malibokhar5238
    @malibokhar5238 หลายเดือนก่อน

    ❤❤❤Ok

  • @sonu.labrez
    @sonu.labrez 2 ปีที่แล้ว

    Sir isko Hindi me ap batate na

    • @forevertechenglish
      @forevertechenglish  2 ปีที่แล้ว

      We have Already made a video on this topic in Hindi visit channel forever tech
      Or video link th-cam.com/video/9uM8mXaSKeU/w-d-xo.html

  • @MajidKhan-gi7my
    @MajidKhan-gi7my 2 ปีที่แล้ว +1

    Ustad g ap apna num to day Mara ap se kam hai urgent

    • @forevertechenglish
      @forevertechenglish  2 ปีที่แล้ว

      th-cam.com/video/oUV8s4q9lt8/w-d-xo.html
      Is video main mera no majood hai

  • @SUSSY-PANTS
    @SUSSY-PANTS 5 หลายเดือนก่อน +1

    Bruh...

  • @AikoDurgaryan-s7u
    @AikoDurgaryan-s7u 6 หลายเดือนก่อน

    Привет можно вапроси

  • @ramasamyramachandran5847
    @ramasamyramachandran5847 2 ปีที่แล้ว +1

    Translate in tamil pls

  • @Ssp-sv7dp
    @Ssp-sv7dp 13 วันที่ผ่านมา

    I can tell this compressor is not healthy... readings are not that good

  • @CFPVideoProductions
    @CFPVideoProductions 10 หลายเดือนก่อน

    Please use real people to do your voiceovers. This robot should be deleated. Your products are depending on the warmth and proper human voice and not an AI monotone presentation.

  • @ScottDLR
    @ScottDLR 6 หลายเดือนก่อน

    Not an inverter compressor

    • @forevertechenglish
      @forevertechenglish  6 หลายเดือนก่อน

      It is an inverter compressor.

    • @ScottDLR
      @ScottDLR 6 หลายเดือนก่อน

      @@forevertechenglish Where is the inverter?

  • @markdi2
    @markdi2 8 หลายเดือนก่อน

    Why do you use a crappy computer voice

  • @kettogeerman174
    @kettogeerman174 ปีที่แล้ว

    I have Never heard of a threephase D.C. motor. Stop teaching "NONSENCE" D.C. does not have frequency. A.C. has frequency. Where have you bent to school? What a"SHAME"

    • @forevertechenglish
      @forevertechenglish  ปีที่แล้ว +2

      3 phase refers to the number of electrical phase windings on the motor. It is switched via a 3-phase power "bridge" from a DC voltage supply. This "bridge" consists of 6 power devices - normally IGBTs, but sometimes MOSFETs. They use pulse-width modulation to control the power, and the order in which the 3 motor phases are energized determines the direction of rotation.

    • @forevertechenglish
      @forevertechenglish  ปีที่แล้ว +1

      The terms AC and DC can describe signals as well. An AC signal is a current, voltage, or numerical sequence that consistently exhibits both positive and negative values, and a DC signal exhibits only positive values or only negative values.

  • @vettalan
    @vettalan 2 ปีที่แล้ว +2

    Bro,that is not overload.it is overload protector