FOUNDATION DESIGN WITH PROTA STRUCTURE PART1

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 พ.ย. 2024

ความคิดเห็น • 25

  • @munyaradzichitsaka95
    @munyaradzichitsaka95 6 หลายเดือนก่อน +1

    I love the way you explain things step-by-step. For the first time, I understood how Padfootings are designed properly in Protastructure. Thank you, my brother.

  • @ashleyokuke6710
    @ashleyokuke6710 10 หลายเดือนก่อน +1

    Watching from Zambia! Thank you sir. You just don't know what you've done

  • @MuhammedMuhammed-ux8vd
    @MuhammedMuhammed-ux8vd 4 หลายเดือนก่อน

    U really knows how to explain. keep it up broo

  • @kaytim6728
    @kaytim6728 ปีที่แล้ว +1

    Good work engineer Joshua from your Ede-, connect friend

  • @anjikuiyalams6417
    @anjikuiyalams6417 2 ปีที่แล้ว +1

    Ma guy ....weh done jare 👍

  • @louismeoto2126
    @louismeoto2126 2 ปีที่แล้ว +3

    Keep up bro. I like your tutorials.you are very raw with your explanation. Respecting real time issues.i have been using staad pro but your tutorial is making me to Change to prota. Thanks bro

    • @Joshua_d_designer
      @Joshua_d_designer  ปีที่แล้ว +1

      Thank you and I am glad the tutorials are helpful

  • @chinonsofrancis8897
    @chinonsofrancis8897 2 ปีที่แล้ว +1

    You're good. This actually helped alot. Thanks

    • @Joshua_d_designer
      @Joshua_d_designer  2 ปีที่แล้ว +1

      Thank you for the compliment sir...
      I'm glad you are satisfied

  • @nicksonrichard5580
    @nicksonrichard5580 2 ปีที่แล้ว

    Keep it up Broh! This is really helpful

  • @Austino-Technology-Ltd
    @Austino-Technology-Ltd 4 หลายเดือนก่อน +1

    Please can I forward a design to you for check my pad only pass at 900mm depth. And too much

    • @Joshua_d_designer
      @Joshua_d_designer  4 หลายเดือนก่อน

      @@Austino-Technology-Ltd send to me adejumo.joshua1@gmail.com

  • @Zorot99
    @Zorot99 ปีที่แล้ว

    Sir, when you use “use maximum load in all combinations” this will design the footing on the factor load.
    Shouldn’t we design the footing on service load only?

  • @ayubakenneth1529
    @ayubakenneth1529 2 ปีที่แล้ว

    Good morning joshuaddesigner, I was following ur amazing design & it's cool. I have an issue with d analysis any time I follow ur examples, and if I start it run for some few seconds & stop. Why?

    • @Joshua_d_designer
      @Joshua_d_designer  2 ปีที่แล้ว

      Does it give any response once the process aborts?

  • @kamoxradiant7743
    @kamoxradiant7743 2 ปีที่แล้ว +1

    Good day My great tutor, I'm facing a problem in this pad footing design, it is show two base instead of one base, like my dead and live load also is show two values for each. I don't know where my mistakes is

    • @Joshua_d_designer
      @Joshua_d_designer  2 ปีที่แล้ว +1

      check the boxes selected and ensure its only dead load and live load you are having there

  • @kamanziprince7002
    @kamanziprince7002 ปีที่แล้ว +1

    Hey joshua , can we have top reinforcement in foundation?? by using protastructure

    • @Joshua_d_designer
      @Joshua_d_designer  ปีที่แล้ว +1

      Yes of course, you can have top reinforcements

  • @ITANGISHAKANelson
    @ITANGISHAKANelson ปีที่แล้ว

    thanks

  • @alhussainabdullahi1541
    @alhussainabdullahi1541 ปีที่แล้ว +1

    Please help me with Prota structure activation code 2022 or 2021

  • @louismeoto2126
    @louismeoto2126 2 ปีที่แล้ว +1

    Keep up bro. I like your tutorials.you are very raw with your explanation. Respecting real time issues.i have been using staad pro but your tutorial is making me to Change to prota. Thanks bro

    • @Joshua_d_designer
      @Joshua_d_designer  2 ปีที่แล้ว

      You're welcome..
      Expect more and welcome to the world of Prota Structure...