Need help, I got shells overlapping in my ETABS model. For specific, my floor slab is overlapping with the autogenerating stiff membrane over the column section. Does the overlapping affect my result? and how I'm supposed to behave?
Hi Decode BD, i model the base and 1 level and check no error, after that i followed your technique add stories to copy level 1 to top stories, then I checked in design check too many errors more than 1000 errors appeared. How to prevent such errors? Thank you
warning messages: "Roof, F4 & F14 are too close. Check at (0 7000 12600)", ........It don't shows over lapping, I checked, how can I fix it? If possible please describe different angles of solution regarding this sort of warning.
hello mr. i want ask something, Warning: Area load transfer, Check Lantai 5, A14. Total loss = 536,25. For load pattern SIDL. how to solve that problem ? thank you
بسم الله الرحمن الرحيم is the best in this vedio
thanks for your effort
Need help, I got shells overlapping in my ETABS model. For specific, my floor slab is overlapping with the autogenerating stiff membrane over the column section. Does the overlapping affect my result? and how I'm supposed to behave?
¡Muy buenos tips... gracias!
Please make a video on solving errors in an irregular shaped slab..I am having lots of trouble with irregular shaped slabs
God bless you!
Thanks
Hi Decode BD, i model the base and 1 level and check no error, after that i followed your technique add stories to copy level 1 to top stories, then I checked in design check too many errors more than 1000 errors appeared. How to prevent such errors? Thank you
Thank youuuuu soooooo muuuuuuuuuch
Muchas gracias excelente tutorial
Thanks
Walaikum Aassalam thank you
warning messages:
"Roof, F4 & F14 are too close. Check at (0 7000 12600)", ........It don't shows over lapping, I checked, how can I fix it? If possible please describe different angles of solution regarding this sort of warning.
Story 4, 6 & 6 are too close....
How to solve this type warning.
Me salvaste , gracias!!
Welcome
Thank you so much bro...
In my Etabs model, it shows error that column drop & slab are too close
hello mr. i want ask something,
Warning: Area load transfer, Check Lantai 5, A14. Total loss = 536,25. For load pattern SIDL.
how to solve that problem ?
thank you
You need to check that area connectivity at mesh joints & modify accordingly.
I'm going to share the video - Modeling of Burj Khalifa - to a Facebook group where there are 50,000 young people from Latin America.
Sir please tell me how can I get sky blue layer on floors
Sir please tell me, howcan I solve this problem in etabs (error in creating frame element hinges)
Gracias!!!
what is error in etabs 2015, " can not generate rebars, object -no' pls help
Not sure/familiar with this problem.
It give only error
It can't generate warning file ?
Any one can help ?
THANKS U SO MUCH
In my case Floors are not overlapping still I am getting warning that floors are to close..
I think it maybe a case of irregular shaped slab designs. Those are tricky to solve if they have over lapping problems
thanks bro.
how to solve " area load transfer" warning ?
I've got the same problem as yours, have you solved it?
@@梅宗敏 not yet
Having difficulty with the same problem
Thanks man
Overlapping slab not an issue
What happened sir I would like to know sir ?
About what brother?
Sky blue layer on floor sir
thanks man
Wc