Vertical Ventilation Video

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 เม.ย. 2014
  • Springdale Fire Department, Springdale, AR- Helmet cam video from a truck company member, FF Johnson.

ความคิดเห็น • 322

  • @4starseniormasterspecialist
    @4starseniormasterspecialist 5 ปีที่แล้ว +143

    These boys pulled myself and my then pregnant wife out of what was left of our truck about 5 years ago when we got hit by a drunk driver. Thank you for your service and God bless you.

    • @117tj7
      @117tj7 ปีที่แล้ว

      Glad your safe

  • @nicholassturgeon5035
    @nicholassturgeon5035 7 ปีที่แล้ว +246

    A few things that as a firefighter stood out as some basic stuff, but we're key.
    1) He started the saw before he started up the ladder. Hugely important because you need to ensure it's still working right before you're already up there.
    2) He brought a halligan which shows he knows what he needs and brought it with him. Should always have a handtool.
    3) On the cuts, he cut past what he already had cut a bit just to ensure a perfect cut.
    4) I heard the radio saying that the Chief was doing a 360*. This is huge because it ensures everyones safety.

    • @Fred-it2ko
      @Fred-it2ko 5 ปีที่แล้ว +31

      Nicholas Sturgeon he also sounded the roof before he stepped on it

    • @Trowo
      @Trowo 5 ปีที่แล้ว +6

      William Hershberger Well that was too obvious so he wouldn't fell in to the fire trough the roof

    • @MrShotgunlover
      @MrShotgunlover 5 ปีที่แล้ว +28

      ...you guys realize firefighters are trained right?

    • @E6ABHnavy
      @E6ABHnavy 5 ปีที่แล้ว +1

      He made 5 cuts even though he knocked the vent off....

    • @thetruepatriot4831
      @thetruepatriot4831 5 ปีที่แล้ว +5

      Kyle he cut the holes to make a bigger vent, that little hole wouldn’t have let out enough heat to help knock out the fire

  • @stoddern
    @stoddern 6 ปีที่แล้ว +205

    At least the home owner was way over due for a new roof

    • @floodkidsgaming7430
      @floodkidsgaming7430 6 ปีที่แล้ว +1

      Noah Stoddert xD

    • @jamesluck2969
      @jamesluck2969 5 ปีที่แล้ว +5

      I saw it and all I could think was well this ones not so good anymore.

    • @christophermack11
      @christophermack11 2 ปีที่แล้ว +1

      Maybe install a couple of skylights now?

  • @johnmulinaro6044
    @johnmulinaro6044 8 ปีที่แล้ว +185

    Brace yourself, the safety police will soon be commenting. Great work and nice hustle

    • @albertaproud7855
      @albertaproud7855 8 ปีที่แล้ว +1

      LOL! No kiddin.

    • @scottallen8329
      @scottallen8329 5 ปีที่แล้ว +3

      John Mulinaro
      Yours was easily the best and most correct comment of all.

    • @messianichebrewshawnkawcak1550
      @messianichebrewshawnkawcak1550 4 ปีที่แล้ว

      Yep. There are always the critics. There is the book, and then there is real life.

    • @bobbobbington6498
      @bobbobbington6498 3 ปีที่แล้ว

      Fk safety theres a job to be done

    • @keanuchungusmode9453
      @keanuchungusmode9453 5 หลายเดือนก่อน

      ​@@bobbobbington6498Do you understand risk management?

  • @brothersofthebackrow
    @brothersofthebackrow 6 ปีที่แล้ว +21

    Holy crap that was some smooth one man stuff . Sounded the roof and everything. Love it

  • @vinnyvlogs2788
    @vinnyvlogs2788 7 ปีที่แล้ว +125

    I thought he fell when he took off his helmet

  • @xBRVTALx
    @xBRVTALx ปีที่แล้ว +3

    Yeah that roof didn't need a hole. Very little smoke pushing from it.

  • @hfdshrimp3973
    @hfdshrimp3973 6 ปีที่แล้ว +59

    Dude when I saw those trucks I was like holy shit orange trucks

    • @kattrak1738
      @kattrak1738 4 ปีที่แล้ว +1

      Ours are blue. Google them. Sugarcreek township ohio.

    • @firerescue2283
      @firerescue2283 3 ปีที่แล้ว

      My departments are yellow

    • @zackhutcheson6359
      @zackhutcheson6359 2 ปีที่แล้ว

      Chrome yellow actually

  • @FireCapt260
    @FireCapt260 8 ปีที่แล้ว +19

    Loved how the firefighter set up the ground ladder quickly and everything else. Learned a lot from this video.

  • @ccrespin34
    @ccrespin34 5 ปีที่แล้ว +12

    Not to call out or Monday morning quarterback this but something I just noticed. He walked to where he decided he wanted to vent and after barely sounding the roof after getting off the ladder he didnt sound at all upon approach to cut site. Then when done he stated to the other two that eventually joined later, "did you feel how spongy the roof was coming over here". Ist that the reason we sound in the first place, yes not being afraid and being aggressive is one thing but taking the extra few seconds to sound could make a difference in life!

  • @dangerousrobot9692
    @dangerousrobot9692 2 ปีที่แล้ว

    Loved the beginning the way he got that ladder up that was smooth. Good work and luck and blessings to ya.

  • @skatefishfla537
    @skatefishfla537 8 ปีที่แล้ว +1

    no wasted motions. Great work!

  • @truthfultruckie9639
    @truthfultruckie9639 6 ปีที่แล้ว

    Local 4016 member here, good job brothers and truck on

  • @cushman11firefighter18
    @cushman11firefighter18 6 ปีที่แล้ว +2

    Thank you for all you do brother

  • @d.chandler2651
    @d.chandler2651 ปีที่แล้ว

    Hell yeah brother, awesome job, keep up the good work!!

  • @minerran
    @minerran 4 หลายเดือนก่อน

    Very impressive the way these FFs hustle, not easy wearing all that heavy gear! Every department should be like this! I'm not a FF but I certainly get the impression that these guys know exactly what they are doing - very experienced! First time I've seen vehicles that were not red, interesting...

  • @co5bass5
    @co5bass5 6 ปีที่แล้ว +15

    But wait, they called for horizontal ventilation.

  • @southeastarkweather
    @southeastarkweather 5 ปีที่แล้ว +2

    Wow glad to see a Arkansas Firefighter on youtube. We liked your video and subscribed to your channel. We see you are on the Springdale Arkansas Fire Department. We are in Monticello Arkansas

  • @thanojon1
    @thanojon1 4 ปีที่แล้ว +29

    Horizontal ventilation, Chief?
    Goes to the roof.

    • @dangerousrobot9692
      @dangerousrobot9692 2 ปีที่แล้ว

      Well he asked whether the chief wanted horizontal or vertical and i'm imagining the Chief said "No vertical" but we just couldn't hear.

  • @bondman00794
    @bondman00794 9 ปีที่แล้ว +10

    ive learned so much just from watching this, great video! and great job!

  • @MadMax-yq9ix
    @MadMax-yq9ix 5 ปีที่แล้ว +21

    I like her just smacked the vent right off lol xD

  • @nicaln5104
    @nicaln5104 4 ปีที่แล้ว +3

    That was beautiful! I love that Haligan/NY Talon Hook that thing is amazing! Plus he got that ladder up smooth even though it’s a 14 those little tosers can fall to the side quick. Those cuts were perfect. Outside Vent kicks ass!

  • @PasqualeDigiovangiacomo90
    @PasqualeDigiovangiacomo90 2 ปีที่แล้ว

    On scene, events hole cut and complete done calmly in under 10 mins, nice job

  • @IAmThyOverlord
    @IAmThyOverlord 5 ปีที่แล้ว +19

    3:13 the firefighter- me. The vent- my wife making my sandwich wrong (just a joke so chill)

  • @67NewEngland
    @67NewEngland 6 ปีที่แล้ว +6

    Those spinning vent caps are designed to pull a draft and should be left alone as long as they are spinning.

  • @MoparGuy1625
    @MoparGuy1625 6 ปีที่แล้ว +1

    Man the roof looked shady af. Nice video!!

  • @ek6063
    @ek6063 6 ปีที่แล้ว +26

    Great job, very professional didn’t waste time. My only critique is I would have yelled “four” when I took out that vent!

    • @harrisonhart9245
      @harrisonhart9245 5 ปีที่แล้ว +2

      Eek "fore"

    • @coleyamos
      @coleyamos 4 ปีที่แล้ว

      Haha I never thought of that but it's useful to the people below. Good Comment.👍🏻

  • @skymedic48
    @skymedic48 8 ปีที่แล้ว +48

    Always been a fan of the non-traditional color scheme apparatus. Typical red/white is boring. These are sweet looking, love the yellow!

    • @Harley2010SG
      @Harley2010SG 7 ปีที่แล้ว +1

      OMG!!! You are one SICK individual! ;o)

    • @bradkretzschmar6772
      @bradkretzschmar6772 7 ปีที่แล้ว +1

      firemedic75 my department we have chartreuse

    • @josephhamler129
      @josephhamler129 7 ปีที่แล้ว +1

      We have baby blue trucks hahah

    • @mrengine9
      @mrengine9 5 ปีที่แล้ว

      @@JuszCause Not anymore. Henrico is going Red and white now

    • @thatchevydude1234
      @thatchevydude1234 5 ปีที่แล้ว

      Same in Colorado their like white I don't like it

  • @americag4241
    @americag4241 8 ปีที่แล้ว +26

    It's always interesting watching how other agencies conduct ventilation vertical operations. There is more than one way to skin a cat, and as long as it gets done in a safe and efficient manner its always a job well done.

    • @njemergencychaser5508
      @njemergencychaser5508 4 ปีที่แล้ว

      America G4 yeah. Watch lafd do vertical ventilation they have probably the safest and most effective ways of doing it.

    • @danielcruz9569
      @danielcruz9569 4 ปีที่แล้ว

      Why would you compare it to skinning a cat?

    • @edloeffler9769
      @edloeffler9769 2 ปีที่แล้ว

      @@njemergencychaser5508I thought I heard them call for HORIZONTAL ventilation, not verticle.

    • @sbdftw1702
      @sbdftw1702 3 หลายเดือนก่อน

      @@edloeffler9769Because most departments view vertical vent as a risky procedure..they don’t train on it nearly enough and it ends up becoming a foreign concept. Gas, smoke, and fire travels up…this is the easiest way to get the bad shit out while also giving the fire an exit to the outside world. Highly effective method but not taught enough. Springdale Fire Dept, Arkansas in the video did an outstanding job and shows just how simple it is. I know this is 9 years old but I’m sure it would still be done this way today if they were to encounter the same sort of structure.

  • @tkl1984jr
    @tkl1984jr 9 ปีที่แล้ว +1

    Awesome stop and vent work

  • @jakebennett3766
    @jakebennett3766 5 ปีที่แล้ว

    That is a badass truck company

  • @LT905yoc
    @LT905yoc 5 ปีที่แล้ว +1

    Very well exicuted im sure theres some comment about going on the roof alone at first but i compleatly understand ya gotta do what ya gotta do sometimes staffing is tight!

  • @davidrossman7925
    @davidrossman7925 6 ปีที่แล้ว +18

    I was browsing TH-cam for ventilation videos to incorporate into my presentation for our rookie academy and came across this video, I'll definitely be using it, it's a great video to illustrate several safety concerns. Although the ventilation hole was accomplished it was unnecessary. I'm all for going on the roof to vent if it needs to be done, but throughout the video there was only minimal smoke production at best. The sawyer went onto the roof alone and didn't sound at all after the pathetic couple hits getting off the ladder. Anyone that has taken a basic firefighter academy knows that you don't knock off attic vents, it's been proven that they are more effective in place. Did he even know where the seat of the fire was or was he simply a moth-to-the-flame since he nearly sprinted to the only spot smoke was visible? I applaud his motivation to get the job done, but this video should by no means be something used to teach people how to perform arguably one of the most dangerous jobs in the fire service. I agree with the other comments about the depth guard, those are gimmicks. They give firefighters a false sense of security and you end up with what we saw here, no rafter rolling. If there was any significant amount of fire attacking those trusses he would have greatly increased the likelihood of falling through the roof because he just ripped through the rafters because his depth guard was set. Ventilation is a skill, you need to know what your saw is doing, hold it near vertical and push it through the work as fast as it will cut, by working the saw in this manner you'll feel the positive "hit" when you reach a rafter and you can then roll it. I won't get into the cut sequence as that may very well be his departments SOP, it isn't the IFSTA way, but IFSTA isn't the only one out there.
    Ok, let the hurt feelings reports fly!

    • @thetruepatriot4831
      @thetruepatriot4831 5 ปีที่แล้ว

      David Rossman I have huge plans on going structure side, and this comment has taught me a lot more than I already knew, I already knew about sounding and the cutting but while watching I hadn’t seen that many safety concerns besides the lack of sounding on the roof until you pointed them out, thank you! I’ll be sure to remember this!

    • @JB91710
      @JB91710 5 ปีที่แล้ว

      Too bad none of you ask how Vertical Venting works. I mean, besides Heat Rises! All you care about is the macho stuff and the best way to cut holes.

    • @tylerdurden6896
      @tylerdurden6896 5 ปีที่แล้ว

      Lol, You don't want me to touch this one Dave. - Mike

    • @JB91710
      @JB91710 5 ปีที่แล้ว +1

      @@thetruepatriot4831 You don't get out much if you don't see the dangerous side of Vertical Venting. Too bad that not ONE of the TH-cam training videos tells you how it actually works without saying "Heat Rises". th-cam.com/play/PLkp0E1ao1XEy2uMomAtjWfScRFcCUmwwv.html

    • @JB91710
      @JB91710 5 ปีที่แล้ว

      @@tylerdurden6896 Go ahead. Touch it!

  • @devonc3948
    @devonc3948 7 ปีที่แล้ว

    awesome video

  • @benthomson9397
    @benthomson9397 ปีที่แล้ว +3

    On some of these home fires the majority of the damage is not from the fire itself but from that tactics used to put it out. Just about every window in the house busted out..holes cut in the roof for ventilation and ceilings pulled down to check for attic fire and last but not least, extensive water damage to the interior.

  • @MaxwellHouse.
    @MaxwellHouse. 8 หลายเดือนก่อน +1

    Fire Academy student here, but a few things I noticed
    -Shouldn’t he have had his SCBA already on?
    -Not using 3 points of contact? Could have used beam/rail instead of grabbing rungs
    -No roof ladder for stability
    -Solo on the roof at first
    -Ladder not secure (tied off or heeled)
    -Climbing with a started saw. Yes to check it before climbing, but being taught to have it OFF climbing

    • @MaxwellHouse.
      @MaxwellHouse. 8 หลายเดือนก่อน

      I understand he’s experienced, and we all cut corners. But isn’t this just unsafe?

    • @blafleur886
      @blafleur886 8 หลายเดือนก่อน

      Most of those academy rules are forgotten in the real world. I wouldn’t turn the saw off. Start it on the ground and hit the brake to climb. No reason to heel the ladder in dirt, just seat the feet good. Debatable, but for a walkable pitch like this, we rely on good sounding and skip the roof ladder. I agree on the scba, though.

    • @cjritchie9701
      @cjritchie9701 6 หลายเดือนก่อน

      Yeah your fresh out of fire 1 alright. Never heard of starting a saw on the roof, your always Gona be solo for a short time, if you’re the first one on the roof. Your not tying a 14 foot ladder to a single story of Roof, come onn. He did have his SCBA on just not his mask and that’s how it supposed to be, mask on scean. Don’t need a roof ladder for that type of pitch, and 3 points of contact? 2 feet 1 hand. That’s 3 buddy.

  • @brianjohnson5942
    @brianjohnson5942 3 ปีที่แล้ว +2

    Video was edited, my helmet cam and fire attack called for vertical prior, command stated horizontal and get to the roof. Video also doesn't show my walk around post ladder deployment

  • @scj8863
    @scj8863 5 ปีที่แล้ว +1

    From the thumbnail, I thought it was a hockey trickshot video. I was pleasantly surprised.

  • @motofireman115
    @motofireman115 7 ปีที่แล้ว +3

    Why after hearing horizontal ventilation over the radio so many times, did vertical still happen? They even said don't go on the roof please. That's the most polite IC I've ever heard. If you can stick your face over the hole after you cut, and you don't get any significant smoke production, there was no need to cut the hole right? The vent he knocked off was doing the same amount of good that his saw work did.

    • @brianjohnson5942
      @brianjohnson5942 6 ปีที่แล้ว +4

      This was my video that I didnt post, my dept posted it and if you watch the unedited version interior calls for vertcle vent, command says horizontal and to get ON the roof, he just got the term backwards. Truck crew knew what needed done. No I am not anywhere close 2 perfect for you arm chair quarterback/safety police but job was done, I had fun and earned my pay for the day. Thanks 4 the positive comments.

  • @tylerryan458
    @tylerryan458 5 ปีที่แล้ว +14

    Physically I seen nothing wrong with his work. I don’t like that he was alone on the roof but we’ve all been this guy at some point so really I can’t complain. My confusion comes with before he gets on the ladder, did I hear him trying to confirm horizontal vent? Was he mixed up? Because he most def vertically ventilated the structure lol. Other than my own confusion, I have to say strong work!

    • @southernfiremen2845
      @southernfiremen2845 5 ปีที่แล้ว +1

      Me too the title said vertical but he asked if it was horizontal and if you heard the radio chatter im pretty sur ei heard command say horizontal

    • @brianjohnson5942
      @brianjohnson5942 3 ปีที่แล้ว +1

      Video was edited, fire attack called 4 vertical, they edited command saying horizontal and get to the roof.

  • @rbliven
    @rbliven 7 ปีที่แล้ว

    Strong truck work. Good to see some people still know how to do it....

  • @Edgygazelle99
    @Edgygazelle99 4 ปีที่แล้ว

    Quick qestion great job frist but second why the trucks different colors in different areas

  • @BattleshipOrion
    @BattleshipOrion 6 ปีที่แล้ว

    Do beat up houses regularly because it looks like you practiced i might not be in rhe same state city or country but thabk you guys for your service

  • @gamerboi111
    @gamerboi111 4 หลายเดือนก่อน +1

    what tool is it that has a ny roof hook on one side and a halligan adz/pike on the other??

  • @rickyjohnson974
    @rickyjohnson974 5 ปีที่แล้ว +2

    That roof is toast 😂😂

  • @TJC4445
    @TJC4445 9 ปีที่แล้ว

    Nice hustle.

  • @pflo7795
    @pflo7795 6 ปีที่แล้ว +1

    If you can vent by popping a few Windows or ppv, go for it, but ya know what, I've been a fireman/Paramedic for 14 years. Any job you do where nothing else gets lost once we get there and all your guys go home is a job well done in my book. That's why we do a post-incident debriefing to see what we could have done differently. Good hustle, like my man said in a previous comment.

  • @charliepiggott2674
    @charliepiggott2674 4 ปีที่แล้ว +1

    You should keep making videos

  • @paser11385
    @paser11385 5 ปีที่แล้ว +5

    i Seen Backdraft once. #Fighting17NeverForget

  • @mrmrswright8250
    @mrmrswright8250 ปีที่แล้ว

    Were is your roof ladder ? 😮

  • @trickplay461
    @trickplay461 9 ปีที่แล้ว

    Is it standard SOP for your dept to climb to the roof with the saw turned on? We practice starting the saw at the foot of the ladder, then after establishing that she wills start, turn it off and restart once safely on the roof. Just curious. Good video.

    • @TJC4445
      @TJC4445 9 ปีที่แล้ว +1

      We used to have that same policy. However, we figured why turn off a perfectly running saw only to try and re-start it in a hazardous environment (i.e.. pitched roof, smoke, dark, wet, etc.) so it was changed.

    • @nycfcistrash2097
      @nycfcistrash2097 9 ปีที่แล้ว

      It's only a single story house, no need to waste time on the roof. If the saw is already started then you don't need to worry about any problems. Get on the roof cut it and get the fuck off no bullshitting.

  • @taylorjackson8681
    @taylorjackson8681 5 ปีที่แล้ว

    Nice pace

  • @chadnading7304
    @chadnading7304 หลายเดือนก่อน

    Sounding a roof doesn't work, there are videos of firefighters sounding roofs right before they fall through it. Edges, Peeks and Valley. Stay on the edges and peeks and valleys, that's where the structural support is the beefiest. Good roof work, I like that this guy knows what a 4x4 hole is and started at the roof vent. Playing golf with the vent. FOUR

  • @a-racecar-driver9668
    @a-racecar-driver9668 5 ปีที่แล้ว +1

    Love it when he whacks the vent off lol

    • @mackhomie6
      @mackhomie6 4 ปีที่แล้ว

      This guy loves anything that'll show a little whackin off

  • @JB91710
    @JB91710 3 ปีที่แล้ว

    It's interesting that you can't find ONE video on VVing that shows it actually improving conditions inside. All they show is the COOL stuff like climbing on the roof of a burning building, cutting the hole and the ever popular, Flames pouring through the hole as the gasses are ignited by the gas movement and they turn a contents fire into a structural fire.

    • @CH-fk5tk
      @CH-fk5tk 2 ปีที่แล้ว

      I’ve been inside quite a few fires and believe me when I say that it works. Visibility clears up almost instantly depending on where you are inside.

    • @JB91710
      @JB91710 2 ปีที่แล้ว

      @@CH-fk5tk Depending on a lot of things. For one thing it does right, it does a hundred things wrong. It just is not worth it. UL tells you that if you want to listen for it in their teaching.

  • @jackh577
    @jackh577 4 ปีที่แล้ว

    Nice job on the roof. I do wish more guys would wrap their hand around the rail, instead off having to take your hand off the ladder reaching for the next rung.

  • @mattreed1817
    @mattreed1817 ปีที่แล้ว +1

    that ladder should have been placed on the charlie side if it was possible and should have had a roof ladder. Also should have been sounding that roof the entire walk not just around the top of the ladder. Also should have been on air before you climbed up. kinda hard to go on air while you're falling through a roof.

    • @keanuchungusmode9453
      @keanuchungusmode9453 5 หลายเดือนก่อน

      there was alot of good and alot of bad in this video. Starting off with jumping out of a moving apparatus, being alone on the roof. not masking up before roof ops, not sounding ahead. also I believe I heard a shit ton of horizontal vent confirmation soooo did he freelance and vertical vent instead? good was that he is not afraid, has great physical stamina, great ladder throw, brought tools, started saw before climbing, cuts were overlapping, vent complete in a short time frame

  • @powersdse
    @powersdse 7 ปีที่แล้ว +18

    am ii the only person that noticed Command requested HORIZONTAL vent several times?

    • @ww2fan18
      @ww2fan18 6 ปีที่แล้ว +2

      Leave that to the OV team, hes the roof guy.

    • @No-vy4cd
      @No-vy4cd 5 ปีที่แล้ว +1

      I thought I was the only one to hear it also. Never once heard vertical ventilation from the radio just the truckie

    • @tylerryan458
      @tylerryan458 5 ปีที่แล้ว +1

      I asked this in my comment. It seemed like they had a short burst of confusing radio traffic where I heard horizontally ventilating.

    • @topangachronic9463
      @topangachronic9463 4 ปีที่แล้ว +1

      I heard it several times and also the fireman asking for confirmation. What is the difference?

  • @peewoops86
    @peewoops86 4 ปีที่แล้ว

    Now we're back with: Why was this in my Recommended?

  • @spinsterjones4987
    @spinsterjones4987 5 ปีที่แล้ว

    Didn't mask up?

  • @drob449
    @drob449 7 ปีที่แล้ว

    Just asking, why did you make an inspection cut? Or was it just out of habit?

    • @JRC1653
      @JRC1653 7 ปีที่แล้ว +1

      That cut is called the 7-9-8 cut. It's just part of the cut.

  • @nemochicky4697
    @nemochicky4697 2 ปีที่แล้ว

    I got to climb onto a training roof and do this it was a lot of fun

  • @davidrogers4051
    @davidrogers4051 4 ปีที่แล้ว +1

    Why a halligan for roof tear off when they make tear off shovels. That big square you cut wouldn't have need to be cut up 3 more times. You could have pulled the whole thing in 30 seconds

  • @paonek1
    @paonek1 7 ปีที่แล้ว +4

    I don't think a roof cut was necessary in this situation; although, I wasn't there and I have no idea what you saw. The cut only lifted a light haze of smoke. Driver stopped a little short. Great job overall

  • @justinrobles00
    @justinrobles00 9 ปีที่แล้ว +13

    Aren't you supposed to roll rafters?

    • @user-nr2nj7wx6x
      @user-nr2nj7wx6x 3 ปีที่แล้ว

      Short answer, yes. Some departments make their cuts differently however and each situation is dynamic. He did have a chain guard on his saw so he wouldn’t have blasted through them completely. It is best practice to weaken the rafters you’re walking on as little as possible though.

  • @UnrelatedNonsense
    @UnrelatedNonsense 6 ปีที่แล้ว +2

    This guy did pretty much everything textbook, great job.

    • @markdupuis879
      @markdupuis879 6 ปีที่แล้ว +1

      Beavey bullshit he did

  • @sakofinland3421
    @sakofinland3421 5 ปีที่แล้ว

    Ive got a question and please dont take offense. I asking this out of ignorance. But why does it take firefighters so long to do something. It just seems like they dont get in any hurry, stand around and talk alot and take forever just to get water going on the fire. Are they not really concerned about trying to save the structure and just more concerned about keeping it from spreading?

    • @davidhoekje7842
      @davidhoekje7842 5 ปีที่แล้ว

      Lots of ways to get hurt, heavy gear and clumsy boots, heavy tools. People are out of the building. Work steady and smart, stay aware of the overall situation.

  • @schoondogg7
    @schoondogg7 8 ปีที่แล้ว

    Did he mask up right before making the cut?

  • @sirwhitecrayon2499
    @sirwhitecrayon2499 5 ปีที่แล้ว +6

    These guys really must enjoy working harder not smarter.

  • @dwightharris7284
    @dwightharris7284 5 ปีที่แล้ว +1

    No need for ventilation. Fire conditions didn’t warrant it. The hole took too long. The could be done quicker with an inspection cut and 2 8ft cuts inside the rafters. This way you at least cut through one full sheet of osb/plywood. Always bring at least a six foot hook to clear the ceiling (may vary depending on the pitch of the roof and hole location. Just my 2 cents.

    • @CH-fk5tk
      @CH-fk5tk 2 ปีที่แล้ว

      Depending on where your at, ventilation might be a must no matter the size.

  • @atvkid0805
    @atvkid0805 6 ปีที่แล้ว +5

    Why would you cut a hole in the roof like that if the fire is already out?

    • @bryangrinius7735
      @bryangrinius7735 5 ปีที่แล้ว +1

      atvkid0805 to prevent backdraft

    • @cyclone3868
      @cyclone3868 4 ปีที่แล้ว

      and for the smoke to escape the building

    • @stephenhusak6098
      @stephenhusak6098 4 ปีที่แล้ว +1

      You must hate your engine guys. To ask that

  • @austinseigel946
    @austinseigel946 7 ปีที่แล้ว

    i have one question when you vent roof aren't you feeding the fire with oxygen

    • @nicholaswells2736
      @nicholaswells2736 7 ปีที่แล้ว +2

      Austin Seigel yes but the thing is em when you vent you're giving all that heat and smoke and steam somewhere to go other than staying in the house with the firefighters on the line. You're making there life a lot easier when you vent

    • @austinseigel946
      @austinseigel946 7 ปีที่แล้ว +1

      ok thank you i thought it would feed the fire more but i know that it makes it easy for them

    • @connortaylor8595
      @connortaylor8595 6 ปีที่แล้ว +1

      nicholas wells Yes, performing VV does remove some smoke and heat. Yet depending on the structure as the fire is given oxygen it allows the fire to spread throughout the structure making the temperature rise throughout the structure making the firefighters life harder and more dangerous.

  • @brennancrumb835
    @brennancrumb835 4 ปีที่แล้ว

    Did you mean horizontal

  • @Coooopur
    @Coooopur 7 ปีที่แล้ว +5

    Can anyone explain to me why no roof ladder was used on the roof?

    • @BAW310
      @BAW310 7 ปีที่แล้ว +2

      low pitch, good traction. If under 5/12 and dry, most dept's don't use a roofer

    • @TopGun8993
      @TopGun8993 7 ปีที่แล้ว

      1 story, low pitch.....no need

    • @tylerryan458
      @tylerryan458 5 ปีที่แล้ว

      The same reason he didn’t use an attic ladder up there, it wasn’t needed. 😂

  • @JO-jv6zn
    @JO-jv6zn 3 ปีที่แล้ว +2

    he cut away from his egress, separating himself, also no smoke or fire came out of that vent whole- ruined the roof for nothing, his cut sequence/ direction was out order, the guys punching the roof in on the interior guys was a huge mistake, you should pull the roof ( shingles and plywood) up/out and remove it, only punch in the interior ceiling after notifying nozzle crew, coordination is huge. list goes on, guy didnt turn his bottle on until after he climb top the roof thats a red flag... also i think at this fire, horizontal ventilation using the windows would have done the job... this was a smack fest.

  • @glennchampion1001
    @glennchampion1001 5 ปีที่แล้ว

    what's going on this time guys
    another house fire or something else

  • @forreststrong797
    @forreststrong797 4 ปีที่แล้ว +1

    They needed a new roof anyway

  • @theuberdriver9029
    @theuberdriver9029 5 ปีที่แล้ว +2

    At least they’re using a Stihl.

  • @claymorgan183
    @claymorgan183 8 ปีที่แล้ว

    While I'm watching this vid, there is a contractor in the next room of my house working with a blowtorch. Hmmmm.....

    • @albertaproud7855
      @albertaproud7855 8 ปีที่แล้ว

      Well? Did he burn your house down? No pun intended.

    • @claymorgan183
      @claymorgan183 8 ปีที่แล้ว

      Nope! The plumbing job was done perfectly, and no bad side effects. Thanks for asking. :)

  • @portagepete1
    @portagepete1 ปีที่แล้ว

    Cutting a hole in roof is how you vent the house so it burns down faster.

  • @mcsheag7001
    @mcsheag7001 6 ปีที่แล้ว

    Ladder 1 or Ladder 6 in the back there.

  • @jugglinB
    @jugglinB 5 ปีที่แล้ว +3

    First off great hustle! See too many FF's walking around with no sense of urgency. Not here to bash but offer some constructive criticism as a 28 yr. FF.
    1. Engine & Truck Co. need to communicate what they see and to cut or NOT cut (depending on the obvious) with light smoke showing.
    2. Should be a minimum of 2-3 man operation depending on what's showing and size of structure.
    3. Once on the roof, bouncing on your feet tells you a lot about the possible conditions under you. Sound the roof like you mean it all the way from the uninvolved to the involved where you'll cut. We use rubbish hooks.
    4. Leave any ventilators in place. They're doing their job drawing out hot air. It took you 9 cuts to cut a single hole that should've taken only 4 cutting around that ventilator (plus those FF's had a heck of a time removing the wood). We do a top cut, two parallel cuts and a bottom cut while rolling the rafters. Get rid of the chainsaw guide but be disciplined to roll the rafters and NOT CUT through them.
    5. Rubbish hooks are great pulling tools (as well as axes) and punching in ceiling. All Truckee's should have an axe on the roof. If that chainsaw fails that's your next cutting n pulling tool. Don't feel the halligan is a good roof tool IMO.
    Food for thought. If that house was well involved, would you have done the exact same thing? Anyway, that's my 2 cents. Stay safe and train like your life depends on it.

  • @gusbailey68
    @gusbailey68 6 ปีที่แล้ว

    I've watched a bunch of videos (no I'm not claiming to be an expert); but this is the first one that I've seen the roof crew knock that stupid vent cap off. I've literally watched a crew stand next to a turbine that was venting black smoke then flame while they cut a louver in the roof. Again, I'm not an expert, but if you're looking for a way to let heat and smoke out why not take the easy route like FF Johnson here did?

  • @nicaln5104
    @nicaln5104 4 ปีที่แล้ว

    That depth gauge is terrible. It always got caught on cuts. Gladly we took ours off, makes the saw a hell of a lot lighter.

  • @terrycalhoun861
    @terrycalhoun861 7 ปีที่แล้ว

    what type of hook is that

    • @1234lavaking
      @1234lavaking 5 ปีที่แล้ว

      Terry Calhoun New York Hook

  • @ethanarriola5763
    @ethanarriola5763 6 ปีที่แล้ว

    I guys should of yelled timber when the roof fell

  • @bobbobbington6498
    @bobbobbington6498 3 ปีที่แล้ว +1

    American fire engines are so long compared to the uk variant

  • @Denzel_Watchington
    @Denzel_Watchington 5 ปีที่แล้ว +1

    *Wouldn't this cause a backdraft down below?*

    • @samjohnson2575
      @samjohnson2575 5 ปีที่แล้ว

      Maybe but if not done in coordination with ic it could start a flow path

  • @nycfcistrash2097
    @nycfcistrash2097 9 ปีที่แล้ว

    I don't like how the saw was shut down so early, should always keep the saw running until you are completely done with the hole

  • @MultiMonster69
    @MultiMonster69 9 ปีที่แล้ว +6

    full time or volly?

    • @davidkissinger1757
      @davidkissinger1757  9 ปีที่แล้ว +5

      Full time, paid department

    • @modelmaker7161
      @modelmaker7161 8 ปีที่แล้ว +1

      +David Kissinger nice rigs they look better than the red and chrome ones

    • @jamesluck2969
      @jamesluck2969 5 ปีที่แล้ว

      @@modelmaker7161, I always loved the off colored ones. To much plane red, get some cool colors like blue, black, orange, or yellow, even green.

  • @Blackwolffe097
    @Blackwolffe097 5 ปีที่แล้ว +2

    Who the hell paints a fire truck Orange & Blue??
    I mean it doesn't look bad but its just weird

    • @fuhwurd
      @fuhwurd 5 ปีที่แล้ว

      Phantom67 who the hell feeds their dog Christmas wrapping ?

    • @Blackwolffe097
      @Blackwolffe097 5 ปีที่แล้ว

      @@fuhwurd
      Wow
      If you use your eyes my dog spit it out afterward.

  • @grahammoulton3374
    @grahammoulton3374 5 ปีที่แล้ว

    What's the point of ventilation in this scenario; I actually don't know

    • @lakelife1154
      @lakelife1154 5 ปีที่แล้ว

      I Think they cut too big of a hole and in wrong location.

    • @robertvanhooser4465
      @robertvanhooser4465 5 ปีที่แล้ว

      Vertical ventilation is good to change deteriorating conditions. It can be used to stop backdrafts, flashovers, and smoke explosions. Overall, the position of the cut is over the area with the most smoke and at the highest point. The cut was efficient and the right size. It was a good cut. The smoke, to me, didn’t read like conditions that needed to be changed with vertical ventilation, but I wasn’t there. I have no idea what they were seeing inside. Putting a video up is basically asking for negative comments. I commend any department that is doing it to help others train.

  • @kavalogue
    @kavalogue 5 ปีที่แล้ว

    Fire would have been out by the time the roof was cut in Ireland

  • @dantegt93
    @dantegt93 8 หลายเดือนก่อน

    Everytime i come across this video, it baffles me at how bad these guys are.

  • @joshroten3997
    @joshroten3997 3 ปีที่แล้ว

    That first truckie needs to go back to vent school.

  • @bradkretzschmar6772
    @bradkretzschmar6772 7 ปีที่แล้ว

    the only question I have is: why those helmets? I'm an explorer and we have helmets like that and I don't like them.

  • @watchthe1369
    @watchthe1369 5 ปีที่แล้ว +6

    Lol, as luck would have it, he caught the center of a rafter. Typical when you want it to go quick and routine, life shifts and inch or two to mess with ya....

  • @rfdf453
    @rfdf453 9 ปีที่แล้ว +7

    Forget to go on air?

    • @DJPacoRamirez
      @DJPacoRamirez 7 ปีที่แล้ว +2

      Chris Ingalls hmm I thought the same, but I'm guessing he didn't want to, till maybe he had to go inside.

    • @G0ldmeml3er
      @G0ldmeml3er 6 ปีที่แล้ว +6

      I know in my department, the roof man only goes an air at his discretion. If you need to go on air bc conditions dictate it, you do, if not, you don't. I could definitely see the "what if" aspect of "what if the roof collapses and he falls in without a face piece on, no air, and helmet not secured.

  • @Mattwaters1986
    @Mattwaters1986 4 ปีที่แล้ว +2

    So giving the fire a way to breath and creating a chimney helps how? Burns down quicker 🤷‍♂️

    • @nickbricks8017
      @nickbricks8017 4 ปีที่แล้ว +2

      Matt Waters verticals ventilations job is to keep firefighters safe. I draws the fire away from the firefighters and victims marking it easier to put out. Also it clears the smoke out giving a better chance to victims inside the building.

    • @tx_7134
      @tx_7134 4 ปีที่แล้ว

      Venation is to relieve the house of smoke and heat from the fire also, fire can spread more from the material it's burning on than the air being feed into it.

    • @Rescue-mt7fl
      @Rescue-mt7fl หลายเดือนก่อน

      That’s what the belief of vertical ventilation is. The science says otherwise. The reality is that the smoke doesn’t actually lift from vent holes less than half the total surface area of the roof. The smoke appears to to lift, because the available smoke (fuel) actually ignites. The illusion is that smoke has lifted and the immediate heat from the hot smoke has been relieved. For a moment, the hot smoke has relieved as it’s not down to the floor, but the radiant heat rapidly increases due to the now ignited smoke. This is why the recommendation for coordinated ventilation is made. Coordinated means water on fire with control of fire before or shortly after ventilation with ventilation done opposite the travel path of crews. Again, it’s no different than breaking out a window, in that a window itself doesn’t vent enough smoke to clear visibility in a well involved room and contents, nor would a window sized hole in the roof. All that is actually happening is opening the flue to allow a hotter cleaner burn and reducing smoke as a result of the increased heat and burn.

  • @briangale2878
    @briangale2878 2 ปีที่แล้ว

    Aggressive vertical vent….I’m not sure he got the order to go vertical rather than horizontal….
    Obviously 2 crews working together