Air Handling Unit Parts I AHU I Damper I Part 2

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 ก.ย. 2024
  • Damper is a very common part in each AHU, and it is illustrated in this video.
    You can check our following article, www.mechstudie....
    Here, we will learn, the basic parts of the air handling unit like,
    Damper frame
    Blades
    Rod
    Actuator
    Subscribe to the "MechStudies" Channel HERE: www.youtube.co....
    Instagram :- / mechstudies. .
    Facebook - / mechstudieso. .
    Website: www.mechstudies.com

ความคิดเห็น • 18

  • @cadguru_7
    @cadguru_7 2 ปีที่แล้ว +1

    Wow Awesome ❤️

  • @kuldeepchaurasiya8433
    @kuldeepchaurasiya8433 2 ปีที่แล้ว +1

    Thank you so much sir for Explain

  • @kuldeepchaurasiya8433
    @kuldeepchaurasiya8433 2 ปีที่แล้ว +1

    I love you Sir ❤

  • @khalidmudathir9520
    @khalidmudathir9520 2 ปีที่แล้ว

    Where to install the motorize dampers in the FAHU as per safety code ?

    • @MechStudies
      @MechStudies  2 ปีที่แล้ว

      It depends on application.
      If it FAHU, you need to put it in SUPPLY & RETURN BOTH SIDE for better control.

    • @khalidmudathir9520
      @khalidmudathir9520 2 ปีที่แล้ว

      @@MechStudies I have FAHU heat recovery wheel ,
      For RAD I agree with you to avoid smoke recirculation inside the building, but if I install the MD in Fresh air duct I will prevent the smoke / fire incase it’s from outside building.
      What do you think ?

    • @MechStudies
      @MechStudies  2 ปีที่แล้ว

      @@khalidmudathir9520 absolutely correct👌

  • @officialringtoneeditor5435
    @officialringtoneeditor5435 ปีที่แล้ว +1

    How to off daimper....?

    • @MechStudies
      @MechStudies  ปีที่แล้ว

      If it is motorized, there will be an actuator which will help to open and close it. In case of manual damper, it has to be closed or open manually. In AHU, it is automatic.

  • @bijayakrushnabehera2403
    @bijayakrushnabehera2403 2 ปีที่แล้ว +1

    Does It can control cfm

    • @MechStudies
      @MechStudies  2 ปีที่แล้ว

      It is used to adjust the air quantity but for regular control, it cannot be used,

    • @bijayakrushnabehera2403
      @bijayakrushnabehera2403 2 ปีที่แล้ว

      @@MechStudies for cfm control what should we use with hepa housing Or duct

    • @dhyandpatel132
      @dhyandpatel132 ปีที่แล้ว

      @@bijayakrushnabehera2403 usually such dampers are used for air flow control though they do not provide great control. If you want a precise and complete control, then you might want to go ahead with a radial damper and preferably with gaskets. Dampers shown in this video only provide crude control from 30% to 95% of design air flow for most installations.

  • @sajadnowruzi851
    @sajadnowruzi851 ปีที่แล้ว +1

    go to emam kh

    • @MechStudies
      @MechStudies  ปีที่แล้ว

      Not getting you, can you please elaborate if you have anything in mind, thanks for visiting.