Air-Cooled vs Water-Cooled Chillers and how they work with Air Handling Units
ฝัง
- เผยแพร่เมื่อ 23 ก.ค. 2022
- In this video we learn how Air-Cooled and Water-Cooled Chillers work with Air Handling Units to Cool Buildings. We learn the advantages and disadvantages of air-cooled chillers vs water-cooled chillers.
ESTIMATING SPREADSHEETS
✅ #1 HVAC & Plumbing Estimating Spreadsheet: mepacademy.gumroad.com/l/AgJDH
✅ HVAC Estimating Spreadsheet: mepacademy.gumroad.com/l/fhxei
✅ Plumbing Estimating Spreadsheet: mepacademy.gumroad.com/l/bcdah
✅ Residential Estimating Spreadsheet: mepacademy.gumroad.com/l/tdwbh
NEWSLETTER & TH-cam SUBSCRIBE
✅ Subscribe for more Videos like this: bit.ly/3J21zXL
✅ Signup for our FREE Engineering/Construction Newsletter: eepurl.com/hJGcTL
✅ Watch our most recent videos: / mepacademy
------------------- SOCIAL ------------------
⚙️ MEP Academy Website - mepacademy.com
⚙️ Twitter - / mep_academy
⚙️ Facebook: / mechanicaltrades
--------IMPORTANT VIDEOS TO WATCH---------
HVAC ENGINEERING and CALCULATIONS
💧How to Calculate Motor Break Horsepower: • How to Calculate Motor...
💧Fan Laws, Calculate CFM, SP, RPM, HP: • Fan Laws How to Calcul...
💧How to Calculate Static Pressure and CFM: • How to Calculate Stati...
💧Condensate Piping Design and Sizing: • Condensate Piping Desi...
💧How do you define a BTU or Tons of AC: • What is a BTU or Ton o...
💧Sensible Heat Transfer Equation for Water: • Sensible Heat Transfer...
💧Sensible Heat Transfer Equation for Air: • Sensible Heat Transfer...
💧Sensible and Latent Heat Transfer Formula for Air: • Sensible and Latent He...
CHILLERS and COOLING TOWERS
💧How Chillers Work, Air-Cooled & Water-Cooled: • How Air and Water Cool...
💧Chiller IPLV Calculation: • Chiller IPLV Calculation
💧Calculate Total BTU of Chiller or Coil: • How to Calculate Total...
💧Calculate GPM or TDH of Chiller or Coil: • How to calculate GPM o...
💧How Cooling Towers Work, Crossflow vs Counterflow: • How Cooling Towers Wor...
REFRIGERATION and REFRIGERANTS
💧How Electronic Expansion Valves Work: • How Electronic Expansi...
💧Refrigeration Cycle: • Refrigeration Cycle 101
💧Refrigerant Piping Insulation: • Refrigerant Piping Ins...
💧New Refrigerants, Codes and Standards: • New Refrigerants Codes...
HVAC SYSTEMS
💧How a Variable Air Volume System Works: • How a Variable Air Vol...
💧Rooftop Packaged HVAC Units Explained: • Rooftop Packaged HVAC ...
💧How Heat Pumps Work: • How Heat Pumps Work Ai...
💧How a Condensing Boiler Works: • How a Condensing Boile...
ESTIMATING
💧HVAC Piping Unit Pricing: • HVAC Piping Unit Pricing
💧HVAC Equipment Cost Database: • HVAC Equipment Cost Da...
💧MEP Estimating Spreadsheet: • HVAC and Plumbing Cons...
💧Construction Labor Rates with Burden: • How to Figure Construc...
HYDRONICS and PIPING
💧How to Read Pump Chart and Select Pump: • How to Read Pump Chart...
BUSINESS - CONSTRUCTION & CONTRACTING
💧Bid Bonds and Performance Bonds: • Construction Bid Bond ...
💧Top 3 Things to Know Before Bidding Commercial Projects: • Top 3 Things to Know B...
💧Top 12 Construction Bidding Websites: • Top 12 Construction Bi...
CONSTRUCTION BASICS
💧General Layout of Construction Drawings: • General Layout of Cons...
💧How to Read Specifications: • How to Read Constructi...
ELECTRICAL and CONTROLS
⚡How Variable Frequency Drives Work in HVAC Systems: • How Variable Frequency...
⚡How a Power Factor Works: • How a Power Factor Works
⚡Ohms Law: • Ohm's Law
⚡3Phase Electricity - How it Works: • 3 Phase Electricity Ho...
VARIABLE REFRIGERANT FLOW
💧VRF Videos: / @vrfwizard
#MEPAcademy #HVAC #Chiller - วิทยาศาสตร์และเทคโนโลยี
Excellent video! I am a Civil Engineer trying to understand Chilled Water Systems and your videos are the best.
Glad you like them! Thanks for watching.
Thank you for the content. I just passed my PE Exam, but getting more practice is always great.
Congratulations on passing the PE exam, that's a great accomplishment. Thanks for watching.
These videos are awesome!!! i dont have a background in engineering but these videos make it so easy to understand the basics of HVAC!
Thanks for watching.
Great Explanations ! Thank you !!!
Thank you
Thank you! I started working at a facility 10 months ago and they have air cooled chillers but are switching to a water cooled chiller. I really didn't understand either system until your video!
Glad we could help! Thanks for watching.
Cristal clear explanation I scanned many videos the most informative one is yours, thanks!
Glad it was helpful! Thanks for watching.
I am just learning for fun and I love these videos! 👍
Thank you
Thank you a lot for your video lessons. It helps me in English learning because I'm an HVAC engineer from not English speaking country.
That's great! Thanks for watching.
Great video with clear explanation!!
Thank you!
Really great Presentation and Explanations - THANK YOU!
You're Welcome
I am doing a school project using revit MEP This video really helps me a lot! Thank you
You're Welcome
I need this software revit mep I need the serial for 2022 version 😢😢
Thanks for explaining.
You're welcome! Thanks for watching.
Thank so much for your sharing material presentation, it is really useful
Glad it was helpful! Thanks for watching.
I'm a mechanical journeyman at a hospital with 6 giant chillers. I primarily deal with the controls and vav's, but my buddy works on the chillers. It's pretty cool to work on them.
Great job. Learn all you can.
Thank you very much for useful information
Thanks for watching.
Please make more videos. You explain things very easy to understand.
We will! Thanks for watching.
That was an amazing video.
Glad you enjoyed it Thanks for watching.
Great video !
Thanks for watching.
Best of the best always, need more and more videos like that👍👍👍🙏👌👌👌😎🇮🇳
Thank You
Very educational video, thanks Sir. Can you make also video about Fire Fighting System.
Noted. Thanks for watching.
I am a mechanical engineer and I just want to let you that your videos are amazing!
Thanks for watching.
Thank you for the adequate explanation, but you may have forgotten an important part. In the event of a variable load on cold water through several air treatment units. You need to reduce the speed of the water pump. Therefore, you must control the operation of the water shredder by placing an insulated water tank suitable for the load. It controls the capacity of the shredder through a special temperature regulator or several thermostats depending on the number of compressors in the shredder.
Thanks for the comment.
Very useful thanks, please make more vedioes.
Thank you, I will
very good 😊
Thank you 😊
THANK YOU
You're welcome. Thanks for watching.
good video
Thanks for watching.
love it.
Thank you
Thanks for this explanation. Had a question regarding the check valve screen filter installed at the FCU. My check valve screen filter is installed on the return line (after the coils)? Is this right? It seems sensible to have this screen filter to be installed after the shut off valve and before the chilled water enters the FCU. Can you confirm?
If the valve is also used for filtration, then having it on the supply side before any coil or control valve would better serve its purpose of preventing debris from collecting in sensitive control valves or clogging heat exchangers.
@@MEPAcademy Thank you first and foremost for replying. That's what I figured. Also, all the piping that carries the chilled water and hot water to our FCUs are ALL Black pipe (same pipe used in gas piping applications). Not sure if you know NYC code but this doesn't seem to be code unless I'm missing something here. Building was built in 2018. It's a newer building
@@JtotheRizzo Not sure about New York, but its common for engineers to specify copper for all small piping up to 2" or 2-1/2", somewhere around there, and everything above that to be installed using carbon steel piping.
@@MEPAcademy The Risers are 1-1/2" (maybe 2") black pipe (looks to be iron and not steel) and branches are 3/4" black pipe then transitions to copper at the shut-off valve to the appliance (FCU). I'm thinking this is the cause of my cooling issues because my HVAC guy found a lot black sediment in the chilled waters. He thinks it's coming from the Riser and Branch piping that is running throughout my building and causing inefficient cooling with some of the apartment's FCUs. Would love to hear your thoughts on this.
@@JtotheRizzo Black sediment could be many things. what kind of chemical treatment is the chilled water system receiving? Are there dielectric unions or nipples between the black pipe and copper? Sounds like the system needs to be flushed. Have you cleaned the tubes of the chiller?
hi...sorry for personal question...but a kelvion gas cooler with 8 total fans in two rows is being installed at the roof of a supermarket next to my bedroom but 3 metre below. in terms of height..do you think this will make too much noise and the heat from the fans will be damaging...would there be any difference during summer and winter noise and heat levels...thx a lot
We would need to see the submittals for the unit being installed. The submittals or engineering manual should show the NC (Noise) levels that will be experienced at different distances from the unit. You state your 3 meters above, but how far horizontally are you from the unit? Sound will reverberate off the walls surrounding the unit if in proximity to walls. Wind direction will affect the discharge air coming off the top of the unit if in a windy area. Heat rises, so the outdoor temperatures will have some effect, which is more important for you during hot days, when additional heat is unwanted. Your local mechanical code will dictate how close this piece of equipment is allowed to a property line. Good Luck.
Thanks a lot...horizontally we are 1 meter from the coolers....the sound pressure levels are 27 and 17 at 10m during day and night...the sound power level is 61 and 51...thanks
the unit name is Kevin GF -MC104G6
If there is a email or phone you can share, I can email you details and we can chat...I am very happy to pay for the consultation...thanks
You might want to contact a sound consultant. That is not our specialty. They can do field measurements, which we don't do. Everything else is just theory from a text book. You need field measurements to document the actual conditions as there are many factors that can play into how sound moves off surfaces.@@spssgs
Can the chiller be substituted by a heat exchanger in a water cooled system ?
In some geographical areas this may work. See our video on Waterside Economizers to get a better understanding. th-cam.com/video/JKnzhDetvjQ/w-d-xo.html
How can I access the program you are using? Would like to train our facility staff. Thanks!
No sure what program you're referencing? All our videos are made by our Engineers.
@@MEPAcademy The program you've use to build the graphics in the video
Professor, can you send a link to a simulation program for cooling and heating systems for mechanical and electrical parts and control circuits? Thank you.
We don't use those programs, but you can find them by searching Google. Here is one of them hvacsimulator.com
Is there water together with the refrigerant inside the chiller? Where is the inlet water coming from that transforms into chilled water for AHU and condenser water for cooling towers? I’m confused
The water and the refrigerant never mix, but transfer the heat between them using a heat exchanger. See our other video on Chilled Water Central Plant basics as we believe that might help you better understand. th-cam.com/video/zit6eWY2hD8/w-d-xo.html
What is the function of the boiler in the cooled water processe
Temperature and humidity levels vary per geographical area. The heating coil can be used when dehumidification is required to drive down the humidity and then bring up the temperature so that it's not too cold, and it can also be used in cold climates where additional heat is needed to supplement any terminal zone heating. The boiler would also feed any VAV reheat Coils are Fan Coils that are not shown in the image.
How I can get this software revit mep ??
It's made by Autodesk. Here is a link to the software. www.autodesk.com/products/revit/mep
Please what is the boiler function there am a bit confused
Temperature and humidity levels vary per geographical area. The heating coil can be used when dehumidification is required to drive down the humidity and then bring up the temperature so that it's not too cold, and it can also be used in cold climates where additional heat is needed to supplement any terminal zone heating. The boiler would also feed any VAV reheat Coils are Fan Coils that are not shown in the image.
Wow
Thanks for watching.
🎉🎉
Thanks.
air cooled chiller 500 tons cooling capacity. water cooled chiller 5000 ton cooling capacity.
?
Bravo
Thanks.