Compressor Surge Analysis in Aspen HYSYS

แชร์
ฝัง

ความคิดเห็น •

  • @majidmeraj86
    @majidmeraj86 ปีที่แล้ว +3

    I am going to every tutorial and following it on Aspen. This is too early for a starter. Once I put speed and use curves, it says over specified. Secondly, it changes the curve data itself. I don't know why.
    Last but not the least, this is great contribution by you. Thanks a lot

    • @eduXinsight
      @eduXinsight  ปีที่แล้ว +1

      You have to reset all the Cv parameters at the initial setpoint before each simulation run because it's dynamic so it will change and in real plant senerio it only happens at startup and shutdown. I hope it will help

  • @majnoon_mechano
    @majnoon_mechano 3 ปีที่แล้ว +4

    Your Tutorials are very useful
    thank you very much of your effort

  • @rameshcheppali4353
    @rameshcheppali4353 9 หลายเดือนก่อน

    Very nice, topic.Well explained.Thanks for your presentation

  • @ASHISHPAWAR-f5n
    @ASHISHPAWAR-f5n ปีที่แล้ว +1

    Very informative and superbly made videos

  • @surajkarmali5742
    @surajkarmali5742 4 หลายเดือนก่อน

    Your tutorial is very helpful sir

  • @muhammadyasir9056
    @muhammadyasir9056 หลายเดือนก่อน

    Thanks for your Hysys video series, I'm watching one after the other.
    But Sir i have a question,
    In the hot bypass valve, you put value of 0.1 of conductance, why 0.1 not any other? Can you please justify?
    Your kind response would be helpful for me

  • @sw-qn1ky
    @sw-qn1ky ปีที่แล้ว

    Thanks for your kind & useful lecture~

  • @sutionojoyodiningrat3610
    @sutionojoyodiningrat3610 หลายเดือนก่อน

    Very cool sir

  • @OlusegunJ
    @OlusegunJ 3 ปีที่แล้ว +1

    Great tutorial.

  • @MageshJohn
    @MageshJohn 2 ปีที่แล้ว

    Excellent work!

  • @ivangaldi2950
    @ivangaldi2950 5 หลายเดือนก่อน

    Hi , other than the shut down, is it possible to simulate also the start-up from an equalized pressure in the system (SOP)? Is it possible to provide IDLE1, IDLE 2, MGS ramp?

  • @saiedmouloud9099
    @saiedmouloud9099 3 ปีที่แล้ว

    Very interesting. Thank's for this toturial

    • @eduXinsight
      @eduXinsight  3 ปีที่แล้ว +1

      you are welcome :)

  • @hosseinhassannia9326
    @hosseinhassannia9326 2 ปีที่แล้ว

    Great tutorial

  • @MusAbssiAbssi
    @MusAbssiAbssi 3 ปีที่แล้ว +1

    A Great video

  • @behnamhashemi3329
    @behnamhashemi3329 ปีที่แล้ว +1

    How did you know to manipulate hot bypass valve and not for example inlet or descharge valve or any other component?

    • @RajKumar-cc1se
      @RajKumar-cc1se 11 หลายเดือนก่อน

      Hot vapor bypass is provided for the system whose operating point lies close to surge line limit. In the above case v dint require hot vapor bypass as operating line is already away from surge line limit. Thats y he reduce the flow across hot vapor bypass

  • @MuzzammilH-r3w
    @MuzzammilH-r3w 9 หลายเดือนก่อน

    Hii Brother Actually it is very nicely explained........
    But when I m implementing in my Aspen It shows the error of OVERSPECIFIED
    Please help me sort out this problem
    Thanks in advance

  • @akashbajpai1139
    @akashbajpai1139 5 หลายเดือนก่อน

    but sir in the my company we are using air compressor for air separation plant where compressor has anti surge valve in the discharge line while cooler on the discharge side of commpressor , but in this video when you performed simulation there anti surge valve installed on the suction side , why ??

  • @Aydar911
    @Aydar911 3 ปีที่แล้ว +1

    Does unisim has the surge analysis function?

  • @aliasadi5833
    @aliasadi5833 ปีที่แล้ว

    Thanks

  • @istiaquerezaauyon1
    @istiaquerezaauyon1 ปีที่แล้ว +2

    "The current flow rate is less than surge Flow.
    The pressure flow solver failed to converge.
    Try using the equation viewer to see where the problem is.
    Dynamic calculations stopped.
    Integration time 1.0125: Integrator Stopped at 1.0 minutes" - What does this mean ? I did everything you did , still the results aren't the same.

    • @majidmeraj86
      @majidmeraj86 7 หลายเดือนก่อน

      I am facing the same issue of integration failed at time 0

  • @nahinzulfiker
    @nahinzulfiker ปีที่แล้ว

    Can you the curve data for practice

  • @gassxy7841
    @gassxy7841 2 ปีที่แล้ว

    hello tks for what you are given us
    just i have a slit problem
    it writes
    the pressure flow solver failed to converge
    so if its possible give us the main file of you to comprae everything inside
    or help us with that problem
    we really appreciate that

  • @saisaipech
    @saisaipech 3 ปีที่แล้ว +1

    I would like to know how you obtained the compressor curve?

    • @eduXinsight
      @eduXinsight  3 ปีที่แล้ว +1

      This data is provided by the vendor

  • @gouravchatterjee848
    @gouravchatterjee848 2 ปีที่แล้ว

    Sir thanks for the information.. But my data is not converging after certain point

  • @kokasairamprasad9256
    @kokasairamprasad9256 2 ปีที่แล้ว

    Sir, I have tried simulating but not succeeded. Kindly help me simulate

  • @mohamedal-rasheed9770
    @mohamedal-rasheed9770 3 ปีที่แล้ว

    When I run the case it says the compressor is over specified. And if I remove one of the inputs, I get a different value/result

    • @andreaservino6687
      @andreaservino6687 ปีที่แล้ว

      I have the same problem, how did you solve it?

    • @andreaservino6687
      @andreaservino6687 ปีที่แล้ว

      I tried the same, erasing the imposed pressure on compressor discharge stream, and now i get a different result. I think that what we got it's the discharge pressure that compressor can produce, for that rpm curve (imposed) and that flowrate (imposed). My opinion is that if we want 30 bar, we have to change either the flowrate or the rpm, please @eduX confirm. ( and thank you for this amazig tutorials :)) )

  • @juanperdomo1
    @juanperdomo1 2 ปีที่แล้ว

    Dear Friend,
    The flow of the first scenario must not exceed the stonewall line. The flow is throttled and should follow that line by lowering the RPM. Best regards

    • @eduXinsight
      @eduXinsight  2 ปีที่แล้ว

      Thanks for correction ☺️

    • @juanperdomo1
      @juanperdomo1 2 ปีที่แล้ว

      @@eduXinsight Hi. This is probably a weakness in the software that could be communicated to its developers.
      The Stonewall line represents the maximum possible flow because it is shocked.
      Some simulators have similar errors when sonic velocity is reached in pipes and do not report that the flow is shocked. Regards

  • @nahinzulfiker
    @nahinzulfiker 11 หลายเดือนก่อน

    Can you please give curve data in excel

  • @libraprocessengineer
    @libraprocessengineer 2 ปีที่แล้ว

    Information