WHAT IS KW, KVA & KVAr IN ELECTRICAL! ACTIVE POWER, APPERENT POWER, REACTIVE POWER

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 ก.ย. 2024
  • What is kw, kva & kvar
    In this video we explain what is kw, kva, & kvar or active power, apperant power & reactive power
    Basically active power or kw is real power which our component takes its also a real power
    Apparent power or kva is total power which we provide power to a load
    Kvar is reactive power or useless power in circuit
    In this video we explain all terms of kw, kva & kvar very easily for more information learning about this topic just watch and learn
    Neutral & earth difference
    • NEUTRAL और EARTH में क...
    Why transformer neutral graund or earth
    • WHY TRANSFORMER NEUTRA...
    Siemens drive parameter setting and connection
    • SIEMENS SINAMICS V20 D...
    How to calculate kwh or electrical bill calculation
    • WHAT IS KWH(UNIT)? HOW...
    Cable testing with multimeter
    • HOW TO TEST CABLE WITH...
    Reverse forward starter power wiring connection
    • REVERSE FORWARD STARTE...
    Manual reverse forward starter with limit switch
    • How to make Reverse fo...
    Automatic reverse forward starter
    • Star Delta starter pow...
    Automatic reverse forward motor starter connection
    • Automatic reverse forw...
    3 phase rccb test on single phase supply practical
    • 3 PHASE RCCB मे SINGLE...
    3 phase ammeter connection with selector switch
    • 3 PHASE AMMETER CONNEC...
    8 pin relay testing with multimeter
    • 8 PIN RELAY TESTING WI...
    How to check ceiling fan common start run with multimeter
    • 3 WIRE CEILING FAN COM...
    How to make dol starter with relay
    • How to make dol starte...
    How to check ceiling fan common start run with series lamp
    • Video
    ammeter connection with current transformer
    • 3 PHASE AMMETER CONNEC...
    Cooler motor testing with series test lamp
    • COOLER MOTOR TESTING W...
    Street light timer setting
    • STREET LIGHT TIMER SET...
    Air compressure power & control wiring practically
    • AIR COMPRESSURE के ST...
    3 phase cable testing with megger
    • HOW TO CHECK CABLE INS...
    3 phase motor test with megger
    • Induction motor test (...
    Dol starter control from different points
    • MOTOR CONTROL FROM DIF...
    How to make reverse forward motor starter
    • How to make Reverse f...
    Manual reverse forward starter with limit switch
    • How to make Reverse fo...
    Automatic reverse forward starter
    • Star Delta starter pow...
    Automatic reverse forward motor starter connection
    • Automatic reverse forw...
    Thanks for watching

ความคิดเห็น • 21

  • @allrounder3710
    @allrounder3710 ปีที่แล้ว

    Siraa bhraa

  • @emfsurvivors7701
    @emfsurvivors7701 4 ปีที่แล้ว

    Sir ur method of teaching is awesome.
    Keep it on sir

  • @jiwanjanoti8620
    @jiwanjanoti8620 ปีที่แล้ว

    Good Technical information.❤

  • @arpitjoshi5710
    @arpitjoshi5710 3 วันที่ผ่านมา

    Sir active power ke formula me power KW me rakhna hoga aur reactive power ke formula me KVA me.. Aisa hi he na?? ya kuch aur..

  • @waseemarif1501
    @waseemarif1501 2 ปีที่แล้ว

    Nice example

  • @souravganguli6744
    @souravganguli6744 4 ปีที่แล้ว

    Smps ke upar ak video banaye plese full details ke sath..🙏🙏🙏🙏🙏s m p s

  • @IbrarTechnical1
    @IbrarTechnical1 2 ปีที่แล้ว

    Nice

  • @alpeshpardhi9572
    @alpeshpardhi9572 4 ปีที่แล้ว

    Sir house wiring me neutral ki loop kyu Kiya Jaya Dino conductor ki size alg rakhi

  • @Govi-c5p
    @Govi-c5p 4 ปีที่แล้ว

    First comment

  • @4629jay
    @4629jay 4 ปีที่แล้ว

    Sir ji input wire ki RED aur BLACK wire interchange kyu hoti freeze mein jahan pe connctor hota h input lead ka RED KA BLACK K SATH AUR BLACK KA RED K SATH KYU HOTA H CONNECTOR WALI JAGAH PE

  • @rajeshlama1119
    @rajeshlama1119 4 ปีที่แล้ว

    Sir invorter charging kitana leti hay 1500 va for 1month

  • @saurabhnarvekar4034
    @saurabhnarvekar4034 ปีที่แล้ว

    We have 3 generators on ship... When only one generator is running for the power plant kw is around 500 kw and kvar is 0.8
    But when I connect no2 generator parallel with no1 or no3 kw is shared equally 250 each but kvar is disturb no 2 takes more kvar 1.0 and other is around 0.5 kvar... What can be the problem?

    • @jiwanjanoti8620
      @jiwanjanoti8620 ปีที่แล้ว

      This is because of voltage droop and governor droop.
      Active sharing by governor and reactive by AVR.

  • @susilkumarjena6740
    @susilkumarjena6740 2 ปีที่แล้ว

    Kya bhai inductive load ko garam kiya jata he .or wo garam honepar lal hojata he.wah kya baat he agar .agar essa he to bhir Hume resistive load or capacitive load ke paribhasa jara samjhaiye.or haan apne jo bola load 3 types hotihe or wo resistive capacitance resistance. Maine kahin nehi suna essa.(load to resistive. Capacitive and inductive hotihe)kuch bhi yaar aapto .

  • @mukeshwalzade9312
    @mukeshwalzade9312 3 ปีที่แล้ว

    Kvar ka long form kya hai

  • @nirmalmishra1880
    @nirmalmishra1880 4 ปีที่แล้ว

    Sir, 650 amps load per ,kitna capacitor lagana hoga

    • @jiwanjanoti8620
      @jiwanjanoti8620 ปีที่แล้ว

      It is depend upon power factor not on load.

    • @nirmalmishra1880
      @nirmalmishra1880 ปีที่แล้ว

      @@jiwanjanoti8620 New factory hai uska load 650amps hai ,ab use PF maintain krna hai kitna KVAR K Capacitor lagane honge

    • @nirmalmishra1880
      @nirmalmishra1880 ปีที่แล้ว

      honge

  • @dranzer_1
    @dranzer_1 2 ปีที่แล้ว

    BHAI GLASS ME 5 L PAANI