Nameplate details of Power Transformer | Explained | TheElectricalGuy

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ส.ค. 2024
  • Nameplate details of power transformer explained in this video. Nameplate of transformer.
    Why transformers are rated in KVA? - • Transformer rated in K...
    Nameplate details of substation equipment complete playlist - • Nameplate Details of S...
    Know what is Impedance - • Resistance Vs Reactanc...
    For more interesting videos & articles about electrical engineering visit - www.theelectricalguy.in
    Find me:
    Facebook - / iamtheelectricalguy
    Instagram - / the_electricalguy
    Twitter - / delectricalguy
    TH-cam - / gauravj
    Google + - plus.google.co...

ความคิดเห็น • 93

  • @KABIRUSULEH
    @KABIRUSULEH 24 วันที่ผ่านมา +2

    Mr. Gaurav you are amazing. Kudos to you for this wonderful explanation.

    • @GauravJ
      @GauravJ  22 วันที่ผ่านมา

      thanks

  • @balasubramanig634
    @balasubramanig634 2 ปีที่แล้ว +1

    This temperature is measured in oil due to heating of windings in oil, by temperature gauge .if temperature exceeds it shutsdown tranifomer by connected to ACB or OCB. I thank super explanation . Max 70 degree C.

  • @prabhakaran20ten
    @prabhakaran20ten 4 ปีที่แล้ว +4

    Thanks for detailed explanation, Electrical Engineer rocks 👌

  • @billdavis606
    @billdavis606 5 ปีที่แล้ว +7

    The video states Lv leads Hv by 30 degrees, or Hv lags by 330, in this case both numbers should be the same. If it states Lv leads Hv, and then Hv leads Lv, the numbers would be different as indicated.

  • @sethtaylor5938
    @sethtaylor5938 ปีที่แล้ว +1

    MVA highest rating is with Fans on. Heat run is usually higher depending on the utility. Then there’s the emergency rating, higher yet. That number is not on the nameplate.

  • @md.shahjahanali4285
    @md.shahjahanali4285 4 ปีที่แล้ว +2

    at 3:03 "LV leads HV by 30 degs or HV lags LV by 330 degs" is not correct. It will be "LV leads HV by 30 degs or HV lags LV by 30 degs"

  • @manig3101
    @manig3101 4 ปีที่แล้ว +1

    You're explain very clearly and very useful .Thanks for vidos

  • @technovisionacademy
    @technovisionacademy 2 ปีที่แล้ว +1

    Your work is really appreciated...👍👍👍

    • @GauravJ
      @GauravJ  2 ปีที่แล้ว +1

      Thanks 😊 Do share and subscribe 😊

  • @eugeneleroux1842
    @eugeneleroux1842 3 ปีที่แล้ว +1

    Thank you for a very informative and use full presentation.

    • @GauravJ
      @GauravJ  3 ปีที่แล้ว

      Glad it was helpful ☺️ do also check out other videos on my channel 😊

  • @tb.casenjo2680
    @tb.casenjo2680 2 ปีที่แล้ว +1

    Hello Gaurav, I would like to see the "turning sense" to clarify tha phase shift in both cases (HV lags or LV leads) the angle is only 30º

  • @moumitagorain3492
    @moumitagorain3492 ปีที่แล้ว +1

    Amazing

  • @FULLMOON36528
    @FULLMOON36528 4 ปีที่แล้ว +1

    beautiful animation...keep it up n thnaks for the beautiful voice...

  • @gajananwakle6670
    @gajananwakle6670 3 ปีที่แล้ว +1

    thank you

  • @badshahengineeringvlogs9718
    @badshahengineeringvlogs9718 ปีที่แล้ว

    Sir please explain all test of power transformer on practical manners. 🙏 we wait

  • @pitamchettri3480
    @pitamchettri3480 5 ปีที่แล้ว +1

    sir please make a video on why electron is negatively charged and what actually is charge?

  • @healingmeditation5970
    @healingmeditation5970 หลายเดือนก่อน

    I THINK FOR Dyn11 HV winding i.e (hour end) should be at 11 and LV winding(minute end) should be at 12 then we can say HV leads LV by 30 deg

  • @Deepakranjan555
    @Deepakranjan555 3 ปีที่แล้ว +1

    Aur bhi electrical video daliye..

  • @saberkangalio9576
    @saberkangalio9576 3 ปีที่แล้ว +1

    Fantastic

    • @GauravJ
      @GauravJ  3 ปีที่แล้ว +1

      Thanks. Do share and subscribe to my channel ☺️✌🏻✌🏻

  • @sebastianbugade3521
    @sebastianbugade3521 ปีที่แล้ว

    Gaurav please reply comment of Bill Davis to clear the atmosphere

  • @kilumumahesh935
    @kilumumahesh935 5 ปีที่แล้ว +1

    Useful data bro ...

  • @rameshtripathy5978
    @rameshtripathy5978 5 ปีที่แล้ว +1

    Good explanation !

  • @surendrakverma555
    @surendrakverma555 3 ปีที่แล้ว +1

    Very good

  • @MrMadhumithan
    @MrMadhumithan 5 ปีที่แล้ว +1

    Hi bro your videos are super

  • @randomjack477
    @randomjack477 4 หลายเดือนก่อน

    Thankyou. Is the LV 1669 amps per phase or the total of 3 phase amps?

  • @muqtardm
    @muqtardm 5 ปีที่แล้ว +1

    Very helpful thanks lot.

  • @Deepakranjan555
    @Deepakranjan555 3 ปีที่แล้ว +1

    Beautiful

  • @osamazahid715
    @osamazahid715 5 ปีที่แล้ว +1

    such a great video, I like it too much.

  • @patakotisrinivas1918
    @patakotisrinivas1918 5 ปีที่แล้ว

    Thanks sir...nice explaination...

  • @amitavmondal5855
    @amitavmondal5855 ปีที่แล้ว

    Sir kindly make a video on average power

  • @rengaramanujan
    @rengaramanujan 5 ปีที่แล้ว +2

    Dyn11 is -30 deg its wrongly mentioned in nameplate

  • @hareshrajyaguru8094
    @hareshrajyaguru8094 2 ปีที่แล้ว

    You should clearly mention that the phase differance will be only between the LINE VOLTAGES of the Primary and Secondary windings. PHASE VOLTAGES of the Primary and Secondary Windings are always in Phase.

  • @jeraldabasolo376
    @jeraldabasolo376 2 ปีที่แล้ว

    nice bidyo sir

  • @sudhakarm4394
    @sudhakarm4394 5 ปีที่แล้ว

    Quality maitained bro

  • @premtours
    @premtours 3 ปีที่แล้ว +1

    Nice

  • @eng.omareyadaljorani9954
    @eng.omareyadaljorani9954 4 ปีที่แล้ว

    Thank you so much Sir,
    Why transformer name plate made of stainless steel?

  • @ruan2587
    @ruan2587 5 ปีที่แล้ว +1

    Thank you sir.

  • @ssh6943
    @ssh6943 4 ปีที่แล้ว +1

    Hi ,can you please explain how three phase AC supply is generated from Alternator and Inverter having phase difference 120°.

    • @GauravJ
      @GauravJ  4 ปีที่แล้ว

      Sure. I’ll try to post a video on it.

  • @curiousguy9544
    @curiousguy9544 5 ปีที่แล้ว

    Thanks. The maximum temperature rise at ambient 50c is given as 50/55. So in running condition the acceptable max temperature is 50/55 or 100/110?

  • @abebehaile8985
    @abebehaile8985 4 ปีที่แล้ว

    tanks for explanation

  • @asimjan438
    @asimjan438 5 ปีที่แล้ว +1

    Great...Thanks...but every one is skipping to explain the percentage impedance....

    • @substationtestingandcommis3452
      @substationtestingandcommis3452 ปีที่แล้ว

      It is % of rated primary voltage required to produce rated current when secondary winding is short circuited.

  • @jmorbasayan1901
    @jmorbasayan1901 หลายเดือนก่อน

    May I know what is the function of OLTC on power transformer?

  • @Santosh9720103812
    @Santosh9720103812 5 ปีที่แล้ว

    the last point about temperature is not ok bro(ambient temp etc)..please check and provide right info..i like your tutoring style though ...god bless you
    ..

  • @visheshgarg4642
    @visheshgarg4642 2 ปีที่แล้ว

    Sir appki clock mai fark nhi hai ,minute hand lamba hota hai or hour hand chota hota hai , or jab 11 bjte hai toh hour (small hand ) 11 pr hoga or minute hand hai (long hand wo 12 pr hoga ,pr aapne toh ulta liya hai ...confused

  • @timhumphries479
    @timhumphries479 5 ปีที่แล้ว

    One question, with % impedance for different taps, if you wanted to find the ohmic value, would you use the voltage at that specific tap as your kVbase or do you use the nominal kVbase for all? Thank you

  • @bojhporiintertenmentsong8501
    @bojhporiintertenmentsong8501 5 ปีที่แล้ว +1

    Nice
    #desielectrical

  • @pankilshingala9309
    @pankilshingala9309 5 ปีที่แล้ว

    In case of LV winding Why lightning impulse voltage is not applicable?

  • @7akm123
    @7akm123 5 ปีที่แล้ว +1

    Other transformers have 2 or 3 types of cooling mention as ( onan / onaf / ofaf ) why ? Is that for each phase or primary/secondary winding ?

    • @zaheerrao1150
      @zaheerrao1150 4 ปีที่แล้ว

      Hakem M over all transformer because all windings are dipped in the same oil tank ... where fans are provided outside the tank where hot oil move in the ducts

    • @Hitlerstopjew
      @Hitlerstopjew 4 ปีที่แล้ว +2

      It is for different stages of the cooling process. The hotter the transformer is, the more stages of cooling will be used. When the transformer is cool it will use only natural convection, then it will add forced convection through the use of cooling fans as the temperature rises.

    • @KENFEDOR22
      @KENFEDOR22 4 ปีที่แล้ว

      @@Hitlerstopjew good explanation! Further, allowing the transformer temperature to rise results in more output. Large 3 phase oil immersed XFMRs will typically be ONAN/ONAF/ONAF with corresponding three MVA stages. A good example: 30/40/50 MVA at 50C rise means at 30 MVA, no fans running, just natural cooling, at 40 MVA, 1/2 the fan bank is running (forced cooling), at 50 MVA, all fans running. A fourth MVA can be added to denote an increased MVA at 65 C (in this case, 56 MVA). The rule of thumb is each MVA step raises 33% (from 30 to 40 MVA), while the 65C jump from 50% is 12% (from 50 to 56).

    • @KhalidMehmood-cm5ri
      @KhalidMehmood-cm5ri 4 ปีที่แล้ว +2

      Brother there are 4 type of coolings systems most prevalent in power transformers.
      Onan
      Onaf
      Ofan
      Ofaf
      First is natural
      Second is air forced
      Third is oil forced
      Forth is oil forced and air forced.
      There are leading and lagging thermostates setting on different temperatures they contineous watch the temperature behaviour of power transformer in normal and peak hours and maneuver the through above mentioned four systems as required time to time.
      (Khalid Mahmood pakistani power xfmr specialist)

    • @7akm123
      @7akm123 4 ปีที่แล้ว

      Thanks to all comments you help me 🙏

  • @sudheersubairkutty1633
    @sudheersubairkutty1633 3 ปีที่แล้ว

    You mentioned cooling of transformers with oil forced water forced (OFWF), could you please specify which rating of transformers (MVA) will use these type of cooling.

  • @Anups_art_energy7
    @Anups_art_energy7 5 ปีที่แล้ว

    Brother could u explain an vector group YNaOd1

  • @praveenkp5463
    @praveenkp5463 5 ปีที่แล้ว

    Why primary winding represents 3 split rectangles?

  • @hardikrana2673
    @hardikrana2673 5 ปีที่แล้ว

    HV vtg is of 33kv then why we are using transformer of 1250KVA?
    We can use lower one?

  • @Deepak_Kumar1993_
    @Deepak_Kumar1993_ ปีที่แล้ว

    Dyn11 is power transformer?

  • @parthzalavadiya2131
    @parthzalavadiya2131 5 ปีที่แล้ว

    Sir In induction motor sometimes efficiency is not indicate why ??

  • @mdabuzafar6883
    @mdabuzafar6883 2 ปีที่แล้ว

    Pls explain nameplate details of a motor

  • @neelbanerjee3086
    @neelbanerjee3086 5 ปีที่แล้ว

    details video about transformer vector groping. please i need to understand correctly.

  • @amarnathmishra1461
    @amarnathmishra1461 4 ปีที่แล้ว

    Good video .How do you define impedance volts ?

    • @substationtestingandcommis3452
      @substationtestingandcommis3452 ปีที่แล้ว

      % of primary voltage applied that will produce rated current when secondary winding is short circuited.

    • @amarnathmishra1461
      @amarnathmishra1461 ปีที่แล้ว +1

      @@substationtestingandcommis3452 That's right.% of rated primary voltage required to establish rated current as secondary is short circuited

  • @jamilajamila3658
    @jamilajamila3658 2 ปีที่แล้ว

    What does mean by 10KVA rating of the transformer? Is it transformer input or output? Please clear me.

  • @satyarout9377
    @satyarout9377 5 ปีที่แล้ว

    Sir why transformer primary & secondary power ratting are different
    Like 30mva/35mva

    • @zaheerrao1150
      @zaheerrao1150 4 ปีที่แล้ว +1

      Satya Rout it’s not p & s winding ratings.... its actually ratings with out cooling & with cooling

  • @jitendrapatil7869
    @jitendrapatil7869 5 ปีที่แล้ว

    Why tapping are provided on HV winding? Why not on LV winding?

    • @Santosh9720103812
      @Santosh9720103812 5 ปีที่แล้ว

      some countries have tappings on LV too..it only depends on usage as mostly LV is secondary in india.

    • @anoopraj8346
      @anoopraj8346 5 ปีที่แล้ว +1

      On hv windings current is low as per transformation equation.So tap changing is preferred on hv.On lv current flow is higher and tapchangings may lead to sparkover and resulting winding destruction

  • @hasanmusanadaf9686
    @hasanmusanadaf9686 5 ปีที่แล้ว

    OLTC which side it's connected for HV side or LV side.

    • @KhalidMehmood-cm5ri
      @KhalidMehmood-cm5ri 4 ปีที่แล้ว

      If step down power tranformer then OLTC HV side if Generator xfmr then lv side but not necessary oltc may be manual.

  • @karthikreddy-hl9dd
    @karthikreddy-hl9dd 4 ปีที่แล้ว

    What does untanking mass and transportation mass means?

    • @KENFEDOR22
      @KENFEDOR22 4 ปีที่แล้ว

      For larger oil immersed transformers, "untanking" mass refers to the core and coil assembly (or the active part) weight/mass or what is actually untanked by a crane. Some larger transformers (20-200 MVA) can have the tank top plate as part of the core/coil assembly. "Transportation" mass refers to the actual weight as it is transported, the tank with the active part inside. For larger transformers, all the accessories that can be removed are to make the transport weight lower (lower cost). Bushings, radiators, fans, even control cabinets are removed for transport. On the largest transformers (think high voltage transmission systems), oil is drained prior to transport to bring transport weight down even lower. Crossing bridges and culverts gets expensive as weight goes up.

  • @alimanaal-atefi3622
    @alimanaal-atefi3622 4 หลายเดือนก่อน +1

    🙋‍♂️💟🙋‍♀️

  • @chandrashekharratnakarjosh8500
    @chandrashekharratnakarjosh8500 5 ปีที่แล้ว

    Hon.Best.

  • @Happy-cz8ft
    @Happy-cz8ft ปีที่แล้ว

    isn't 11 min 66 deg? ((11/60)*360)

  • @chebrolupavankumar899
    @chebrolupavankumar899 5 ปีที่แล้ว

    Pls explain tapping theory

  • @rsg5850
    @rsg5850 5 ปีที่แล้ว

    DYnAllavan!

  • @donberg01
    @donberg01 4 ปีที่แล้ว

    Question: why do engineers use % of Z & not Ohms?

  • @kashikhan518
    @kashikhan518 2 ปีที่แล้ว

    ⁰0

  • @horizonrohit
    @horizonrohit 4 ปีที่แล้ว +1

    Very good