Simpleng Single Phase Load Schedule Tutorial

แชร์
ฝัง

ความคิดเห็น • 33

  • @JAZZ00429
    @JAZZ00429 ปีที่แล้ว

    Galing malinaw po Sir, nireview ko lang po itong gawa mo sir, isa din po akong designer❤️❤️❤️ salamat po dito.

  • @nicocompleto5353
    @nicocompleto5353 ปีที่แล้ว

    Nice Sir!! Three Phase naman po sunod..Watching your vlogs po always..

  • @jnc5255
    @jnc5255 ปีที่แล้ว

    Sir, parequest po ng video tungkol sa formula ng feeder size at main protection computations kung paano ginawa at saan yan kinuha. Maraming salamat po

  • @EvanAlmonia
    @EvanAlmonia หลายเดือนก่อน

    Good day Engr. sa makikita ang power factor?

  • @dreamersleeper9839
    @dreamersleeper9839 ปีที่แล้ว +1

    Sir, may provision ba sa PEC kung ilang convenience outlet ang pwede sa isang branch circuit? And lighting nrin po. Thank you!

  • @JhunLagasca-f2l
    @JhunLagasca-f2l 10 หลายเดือนก่อน +1

    Sir pede po bang gamitin ung,#10 or5.5mm.sa 20 ampers,paki sagot nalang po ngayon kung pede.salamat po.

    • @therealmends
      @therealmends  10 หลายเดือนก่อน

      5.5sqmm for 30A CB
      3.5sqmm for 20A CB

  • @ALBERTLUSTADO
    @ALBERTLUSTADO 6 หลายเดือนก่อน

    Sir regarding sa Main circuit breaker anong standard na computation sa PEC? hindi 250% dapt ng load current?

  • @juvelitonavarro2079
    @juvelitonavarro2079 5 หลายเดือนก่อน

    Good day Engr. pwde po bah makahingi ng copy ng table ng wire sizes, breakers, grounding and conduit na gagamitin 🙏 para may reference... salamat po

  • @kentbaba7645
    @kentbaba7645 5 หลายเดือนก่อน

    Good Day Engr., napakalaking tulong po yan sa studies ko, pwede po ba humingi ng copy ng file nyo po. Para po sa School project ko po

  • @edralinbacalso3255
    @edralinbacalso3255 9 หลายเดือนก่อน

    Hello sir, saan po ba kinuha yung 50 Ampers ng main Breaker? Pasinsya tanong medyo hindi ko na gets😁

  • @erwinsudla2473
    @erwinsudla2473 6 หลายเดือนก่อน +2

    Sir pano nyo po nakuha yung power factor ng each point?

    • @meowmeow0_064
      @meowmeow0_064 6 หลายเดือนก่อน

      same question po

  • @Jairus-ul9kv
    @Jairus-ul9kv หลายเดือนก่อน

    Sir yung AT mo masyadong mababa kasi yung 80% ng 50 ay 40A tas yung Total Amp mo ay 44Amp. Mag overload yan sir

  • @justnouse1782
    @justnouse1782 8 หลายเดือนก่อน

    Pwede po b mgpakabit ng temporary Ng kuryente ng wla pa pong building permit?

    • @therealmends
      @therealmends  8 หลายเดือนก่อน

      Request ka sa meralco, temporary connection.

  • @jnc5255
    @jnc5255 ปีที่แล้ว +2

    Hi sir, may tanung lang po ako. Bakit po naging highest current rating ang 6.14A bakit hindi ang 13.04A? Thanks po sa sagut

    • @reyjetrodondoyano6564
      @reyjetrodondoyano6564 ปีที่แล้ว

      Highest Rating Motor po. Yung 13.04A is water heater lang po yun. Kaya ganun

    • @therealmends
      @therealmends  ปีที่แล้ว

      tama. thanks.

    • @geomelquiniones130
      @geomelquiniones130 11 หลายเดือนก่อน +1

      ​​@@therealmends7.67 po ang ACU. bakit ang 6.14 ang ginamit?

    • @fredbunyi1268
      @fredbunyi1268 3 หลายเดือนก่อน

      @@geomelquiniones130 un lang, bkt nga ba? sa pec 2017 example(sa last pages) eh kasama acu sa basehan ng highest motor load

  • @marygraceparagsa7112
    @marygraceparagsa7112 7 หลายเดือนก่อน

    Sir ano po meaning ng At sa CB Rating?

  • @meowmeow0_064
    @meowmeow0_064 6 หลายเดือนก่อน

    saan po nang gagaling yung power factor?

  • @louisezero3129
    @louisezero3129 10 หลายเดือนก่อน

    Hello po sir. Pwede makahingi ng full table mo para sa PEC 2017 table C.10

  • @catangisip
    @catangisip 2 หลายเดือนก่อน

    Is "P" number of poles or phase? It's phase as per PEC.

    • @therealmends
      @therealmends  2 หลายเดือนก่อน +1

      P "Poles"

    • @catangisip
      @catangisip 2 หลายเดือนก่อน

      No need to put AF?

  • @ryannel000
    @ryannel000 ปีที่แล้ว

    Sir pwede kaya humingi ng file ng PEC table mo. Thanks

  • @elucidationdefender
    @elucidationdefender ปีที่แล้ว

    Hi, may questions po ako. Paano po pag walang booster pump or motor yung residential? Ano pong multiplier ang gagamitin ko para makuha yung feeder size? Tsaka paano po nakapag-come up sa 50AT na main protection? Disclaimer, interesado lang po dito, hindi po ako EE student. Salamat po sa sasagot.

    • @therealmends
      @therealmends  ปีที่แล้ว

      If Wala motor loads Wala na yang + 25%. We use 50A main fit Siya for all loads, puwedi next size up 60A for future expansion.

    • @JuliusRepuesto
      @JuliusRepuesto 11 หลายเดือนก่อน

      sir diba pag sa grounding sunod na mas mababa sa size wire ng line ang gamitin..if 3.5mm² line ang grounding 2.0mm²

  • @jerwingalanza5719
    @jerwingalanza5719 7 หลายเดือนก่อน

    sir pwede po makahingi mga table na ginamit niyo dito? salamat po

  • @bootleg4870
    @bootleg4870 ปีที่แล้ว

    Good video sir, pwede po ba ako makahingi ng copy mg file nyo