Eccentric Footing Design in SAFE software. Strip Footing Design, Property line column footings.

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ก.ค. 2021
  • Below is a link to Our Course
    designskill.in/courses/master...
    whats App on +919113460003
    Eccentric Footing : All you Need to know,
    design of eccentric footing,
    eccentric footing example ,
    is eccentric footing safe,
    types of eccentric footing,
    eccentric footing formula​​​, eccentric footing design as per is-456 pdf,
    eccentric footing design as per is-456, eccentric footing design example, how to design eccentric footing, eccentric wall footing design example, difference between concentric and eccentric footing, an eccentrically loaded foundation is shown in figure, footing eccentricity calculation,
    eccentric footing concrete calculation, eccentric footing calculation

ความคิดเห็น • 6

  • @design_skill
    @design_skill  3 ปีที่แล้ว +1

    Uplift could be possible in footing for many reason like hydraulic uplift pressure acts in upward direction, earthquake forces and also Larger eccentricities will also cause a portion of the footing to lift off the soil, because the soil-footing interface cannot resist tension. For a rectangular footing, this occurs when the eccentricity exceeds
    ek =𝑙/6
    ek =b/6
    This is referred to as the kern distance. Loads applied within the kern.
    There could be many solution of uplift like doing anchoring, dewatering, increasing SW etc but you can not use these solution because this uplift is not caused by hydraulic uplift or earthquake force.
    There was uplift caused eccentricity and could be controlled by giving strap beam, there are two solution you can give combined or give strap beam.

  • @imrankaragathraik
    @imrankaragathraik 3 ปีที่แล้ว

    Thank you So much.

  • @illusionarchitecturalplann7655
    @illusionarchitecturalplann7655 3 ปีที่แล้ว

    Thanks sir for guidence

  • @arunchandbala9597
    @arunchandbala9597 2 ปีที่แล้ว

    Sir,what was the price of this Course?

  • @FaizanShaikh-xd7bo
    @FaizanShaikh-xd7bo 3 ปีที่แล้ว

    there is uplift in your design which is not acceptable as EARTHQUAKE CODE and the strap beam is not the solution for this situation

    • @design_skill
      @design_skill  3 ปีที่แล้ว +1

      Uplift could be possible in footing for many reason like hydraulic uplift pressure acts in upward direction, earthquake forces and also Larger eccentricities will also cause a portion of the footing to lift off the soil, because the soil-footing interface cannot resist tension. For a rectangular footing, this occurs when the eccentricity exceeds
      ek =𝑙/6
      ek =b/6
      This is referred to as the kern distance. Loads applied within the kern.
      There could be many solution of uplift like doing anchoring, dewatering, increasing SW etc but you can not use these solution because this uplift is not caused by hydraulic uplift or earthquake force.
      There was uplift caused eccentricity and could be controlled by giving strap beam, there are two solution you can give combined or give strap beam.