Diagnosing Daikin U0 Error⎪2

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 มี.ค. 2023
  • HVACR⎪HVAC⎪REFRIGERATION⎪AIR CONDITIONING⎪AIR CONDITIONER VIDEOS
    In this video I attend a break down where the unit is displaying a U0 Fault Code and won't run. I found the Outdoor Printed Circuit Board to be faulty.

ความคิดเห็น • 41

  • @MentalLapse09
    @MentalLapse09 ปีที่แล้ว +3

    Yeah definitely agree that inverter air conditioning pcbs are fragile when it comes to storms/surges.
    I like to put surge diverters in my quotes as a recommended option.

    • @maracservices
      @maracservices  ปีที่แล้ว +1

      That’s a good idea. I’ll have to start doing the same thing!

  • @robalexander7348
    @robalexander7348 ปีที่แล้ว +1

    Nice vid Mitch, and good to see you on the job bright n early 08.10 👍 and luv the way that outdoor compressor is only mounted on loose bricks, also No 240v isolator 🙄

    • @maracservices
      @maracservices  ปีที่แล้ว

      Definitely wasn’t installed by me that’s for sure 😂

    • @robalexander7348
      @robalexander7348 ปีที่แล้ว

      @@maracservices Mate, it's sure not your work, we all now your quality work by now, maybe the owner would agree to wall mounting brackets being fitted as well 👍

  • @liqfx982
    @liqfx982 ปีที่แล้ว +2

    Informative video mate. I’m Keen to see the board replacement if you film it when you go back

    • @maracservices
      @maracservices  ปีที่แล้ว +1

      Thanks mate, I’ll definitely record it but I’m not sure when because according to Daikin’s Global Data Bank there are no PCB’s available in Sydney. Which normally means none in Australia. Hopefully soon though.

  • @BERESHIDA2008
    @BERESHIDA2008 ปีที่แล้ว +1

    Great videos

  • @nguyenthechung
    @nguyenthechung ปีที่แล้ว

    Thanks for your's share...!

  • @softroadingnewzealand5210
    @softroadingnewzealand5210 ปีที่แล้ว +1

    I need to ship you a proper LA Dodgers hat haha. Great video and learning a lot from your channel…

    • @maracservices
      @maracservices  ปีที่แล้ว

      Haha this hats the best mate. Been through a lot together!

  • @FreedomInMindtv
    @FreedomInMindtv ปีที่แล้ว +1

    Nice one Rodney 🤙🏻

    • @maracservices
      @maracservices  ปีที่แล้ว +1

      Out of control on a regular basis

  • @rodneycooper5474
    @rodneycooper5474 ปีที่แล้ว +2

    Hey mate just wondering why all the resistance readings the same? For single phase shouldn’t the highest be between run and start, then start and common, then run and common?

    • @maracservices
      @maracservices  ปีที่แล้ว +1

      It’s because it’s a 3 phase DC Compressor mate.
      Good question though!

    • @BERESHIDA2008
      @BERESHIDA2008 ปีที่แล้ว

      In iverter motor it should read the same reading

  • @kcomfortsystemshvac7060
    @kcomfortsystemshvac7060 ปีที่แล้ว

    Nice video 👍 let’s say if you the unit it short the gas …what the best away to add r32 ? What type tecnic are you use it ? Thank you

    • @BERESHIDA2008
      @BERESHIDA2008 ปีที่แล้ว +2

      when ever posible with a scale by weight , the unit has a label indicating how much the unit takes

    • @maracservices
      @maracservices  ปีที่แล้ว

      Find the leak, fix the leak, evacuate the system and then weigh charge the gas back in 👍🏻

  • @Rayray_unicornplayz567
    @Rayray_unicornplayz567 ปีที่แล้ว +1

    Are you going to make a part 2 for it?

    • @maracservices
      @maracservices  ปีที่แล้ว

      I am however Daikin don’t have any of those PCB’s in stock so we are currently waiting unfortunately.

  • @nettoyageplusplus4947
    @nettoyageplusplus4947 3 หลายเดือนก่อน

    Comment vous avez testez la carte électronique ? Merci

  • @marzgtp
    @marzgtp ปีที่แล้ว +1

    what is a U4 long beep? And what should I look for on my Daikin unit

    • @maracservices
      @maracservices  ปีที่แล้ว

      Communication error between indoor and outdoor unit. It could be a fault in the interconnect wiring but most likely a faulty PCB.

  • @olliebulldog951
    @olliebulldog951 ปีที่แล้ว +1

    Hi, have you ever had a u0 04 error?
    Daikin cant seem to figure it out and blaming airflow, however system was working fine for 3 years through many 40c days.
    Gas has been reclaimed and checked.
    Indoor coil thermistor replaced.

    • @maracservices
      @maracservices  ปีที่แล้ว +1

      If it’s not short on refrigerant and a technician has confirmed this. You need to test the low pressure transducer is actually working. It might think it’s low on refrigerant when it actually isn’t.

    • @bmiadmin5784
      @bmiadmin5784 6 หลายเดือนก่อน +1

      Change brand next time mate, this brand is too much problem and gives you headaches....

  • @chiller-on
    @chiller-on ปีที่แล้ว +1

    Well, at least they put it on the stones, they could just put it on the ground😁

  • @ClimateAdaptation
    @ClimateAdaptation ปีที่แล้ว +1

    If the fuses don't have continuity could you replace them to try and get the PCB working again?

    • @maracservices
      @maracservices  ปีที่แล้ว +1

      Yeah definitely however unfortunately in this case the fuses are fine and do have continuity. The issue is in the board.

    • @adrianvisintin1961
      @adrianvisintin1961 ปีที่แล้ว +1

      @@maracservices I love how air conditioning company’s don’t put replaceable fuses 😅 . Can I ask what props you use to test small components

    • @maracservices
      @maracservices  ปีที่แล้ว +1

      @@adrianvisintin1961 I know it’s so ridiculous hey.
      So my fluke meter came with prongs that I use 99% of the time but I found a really cheap no name multi meter laying around that had really sharp prongs. So basically I put the prongs in my bag to test plugs and what not. So to answer your question, I use no name Chinese leads for plugs and decent fluke leads for everything else haha.

  • @myrah_adzy
    @myrah_adzy ปีที่แล้ว +1

    hi mate ever had an e5 error?

    • @maracservices
      @maracservices  ปีที่แล้ว

      Yeah mate that’s just an error code that comes up when the compressor gets to hot. Unfortunately there’s many things that could cause that so it’s impossible to tell you the exact problem without checking stuff but I can tell you that the compressor got too hot. Error comes on when the thermal overload is tripped which is located on top of compressor.

  • @thomasmarchant4054
    @thomasmarchant4054 ปีที่แล้ว +1

    Had this error before turned out to be eev. System was pumping itself down into a vacuum.

    • @josephwhite373
      @josephwhite373 7 หลายเดือนก่อน

      Was there frost on one side of eev

  • @tarekabuhijleh5638
    @tarekabuhijleh5638 4 หลายเดือนก่อน

    U0 error REFRIGERANT SHORTAGE

    • @maracservices
      @maracservices  4 หลายเดือนก่อน +1

      lol I know but it was not short on refrigerant. It had a faulty board

    • @tarekabuhijleh5638
      @tarekabuhijleh5638 4 หลายเดือนก่อน

      @@maracservices ok